Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAdmitted-Finance KUNWAR SADAN VEER KUNWAR SINGH COLONY AIRPORT ROAD HINOO RANCHI 834002 JHARKHAND | RANCHI | RANCHI | JHARKHAND | 834002 | ₹4.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.2 Cr+₹30,239.94 (0.07%)Admitted-Finance SERVESHWARI BHAWAN NEAR MAHADEV MANDIR KATHAL MOD PO LALGUTWA THANA NAGDI JHARKHAND 835303 | RANCHI | RANCHI | JHARKHAND | 835303 | ₹4.2 Cr+₹30,239.94 (0.07%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ARUN KUMAR L1 | M/S B D Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Providing coarse clean sand in filling in foundation trenches or in plinth including thick with all leads and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted voume). | 40.66 | cum | 414 ₹16,832.41 Lowest | 414 ₹16,832.41 Lowest |
| 2.00 | Providing designation 75B Brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. | 34.52 | cum | 5,099 ₹1,76,042.98 Lowest | 5,099 ₹1,76,042.98 Lowest |
| 3.00 | Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening, carriage of materials, raking out joints to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement) all complete as building specification and direction of E/I. | 16.2 | Sqm | 668 ₹10,821.6 Lowest | 668 ₹10,821.6 Lowest |
| 4.00 | Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/l. | 14.35 | cum | 123 ₹1,765.17 Lowest | 123 ₹1,765.17 Lowest |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 20.86 | cum | 4,492 ₹93,680.66 Lowest | 4,492 ₹93,680.66 Lowest |
| 6.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Lintel | 257.52 | cum | 6,093 ₹15,69,069.36 Lowest | 6,093 ₹15,69,069.36 Lowest |
| 7.00Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). | |||||
| 7.01 | Floor Joint of 100 mm gap | 40.24 | mtr | 4,761 ₹1,91,601.68 Lowest | 4,761 ₹1,91,601.68 Lowest |
| 7.02 | Floor Joint of 150 mm gap | 40.24 | mtr | 5,065 ₹2,03,835.86 Lowest | 5,065 ₹2,03,835.86 Lowest |
| 7.03 | Floor Joint of 200 mm gap | 40.24 | mtr | 7,516 ₹3,02,473.9 Lowest | 7,516 ₹3,02,473.9 Lowest |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
16 Nov 2021, 11:00 amClosed
Nodal Officer
e-Procurement Cell, Office of the Chief Engineer Combined office Building. Building Construction Department, Line Tank Road, Ranchi
Proposed Upliftment of Corridor ,Lobby, Common Toilet and Common Area at FFP Building , Dhurwa,Ranchi
2021_BCD_52772_1
BCD/CE/64/Ranchi Div-02/2021-22
Open Tender
Civil Works - Buildings
Item Rate
180 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE BCD Building Division No-02 Ranchi
₹4.2 L
29 Nov 2021
2 Nov 2021
17 Nov 2021
2 Nov 2021
16 Nov 2021
2 Nov 2021
Amount
Providing coarse clean sand in filling in foundation trenches or in plinth including thick with all leads and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted voume).
Providing designation 75B Brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints of screening materials, scaffolding, ranking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening, carriage of materials, raking out joints to 15mm depth curing taxes and royalty (but excluding the cost of reinforcement) all complete as building specification and direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Lintel
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063).
Floor Joint of 100 mm gap
Floor Joint of 150 mm gap
Floor Joint of 200 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063) and direction of E/l.
Wall Joint of 100 mm gap
Wall Joint of 150 mm gap
Wall Joint of 200 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement
Roof Joint of 100 mm gap
Roof Joint of 150 mm gap
Roof Joint of 200 mm gap
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l.
Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) and direction of E/l.
Providing Tor steel reinforcement of 10mm dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
Providing Toe steel reinforcement of 12mm to 32mm dia bars as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel)
Providing Toe steel reinforcement of 12mm to 32mm dia bars as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel)
Providing and laying Double Charge vitrified floor tiles in Different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS 15622/ISO 13006, of approved make , in all colour and shades laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointed with grey cement [email protected] kg /sqm including grouting the joints with white cement and matching pigment etc.Size of tiles 600x600mm and direction of E/l.
Providing 12mm thick cement plaster (1:6) -with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/l.
Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floor and taxes all complete as per building specification and direction of E/I.
Labour for scrapping old paint with paint remover and blow lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/l.
Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dust, dirt. Scales amokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (mode of measurement of area shall be multiple by the co-efficient as indicated in building specification) and direction of E/l.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling old plaster and plointing in cement or lime and raking out joints to 15mm depth watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Removal of old tarfelt and disposal of debris with all leads complete job as per direction of E/l.
Covering of treated suface with PCC :- Provtdtng 50 mm lhtck Cemenl Concrete M20 (1:1.5:3) per buildtng speethclton and dtrectrons of Ell Panels that has been left should be casted next day.There should be 6 mm gap between Panels. Brand-Sika-Piastocrate plus. MYK proof WP 1 O,Fosroc-Conplast X 4211C. Dr fixll Pidtproof LW+ or EqUivalent and direction of E/I.
Providing and filling of 6mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST).Brand:-Sika Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent and direction of E/I.
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same and direction of E/I.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration and direction of E/I.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% and direction of E/I.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. and direction of E/I.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm and direction of E/I.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade and direction of E/I.
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive and direction of E/I.
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) and direction of E/I.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot DipGalvanised with serrations and serrated washers to arrest the wind loadmovement, fasteners, SS 316 Pins and anchor bolts of approved make inSS 316, Nylon separators to prevent bi-metallic contacts all completerequired to perform as per specification and drawing The item includescost of all material & labour component, the cost of all mock ups at site,cost of all samples of the individual components for testing in an approvedlaboratory, field tests on the assembled working curtain wall with aluminiumcomposite panel cladding, cleaning and protection of the curtain wall withaluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics allcomplete , as per the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actualarea on the external face of the curtain wall with Aluminum CompositePanel Cladding (including width of groove) shall be measuredin sqm. up to two decimal places and direction of E/I.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) and direction of E/I.
Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab includung rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 25 mm thick and direction of E/I.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size,12.5 mm thick tapered edge gypsum moisture resistant board and direction of E/I.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections, 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing and direction of E/I.
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete and direction of E/I.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead as directed by Engineer-in-charge.
For thickness of tiles above 25 mm and up to 40 mm as directed by Engineer-in-charge.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): as directed by Engineer-in-charge.
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry as directed by Engineer-in-charge.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). as directed by Engineer-in-charge.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment as directed by Engineer-in-charge.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: and as directed by Engineer-in-charge.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Carriage of materials from source to site work including loading and unloading all complete job as per specification and direction of E/I.
Bricks - 8km (1k + 7p)
Sand - 10 km
Chips - 22 km
BUILDING RUBBISH
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
600mm X 450mm size
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. as directed by Engineer-in-charge.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as directed by Engineer-in-charge.
Coupler 75 mm
Coupler 110 mm
Single pushfit Coupler 75 mm
Single pushfit Coupler 110 mm
Single tee with door - 75x75x75 mm
Single tee with door - 110x110x110 mm
Single tee without door - 75x75x75 mm
Single tee without door - 110x110x110 mm
75 mm bend
110 mm bend
Shoe (Plain) 75 mm
Shoe (Plain) 110 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete as directed by Engineer-in-charge.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin- Charge. Internal Work- Exposed on wall.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing VIP Bathroom Fittings :- Supplying, Fitting and Fixing of TOWEL Rail. 24" as directed by Engineer-in-charge.
Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
Non Schedule
Waterproofing Treatment to RCC Roof Slab. a) Preparation of the surface: Oil, grease, funguses etc. by wire brush and wash with plenty of water. b) Providing and applying STARBOND BASB 30 (It is Bonding Agent) using all joint and repair honey-comb area, cracks and other coving area on terrace. c) Providing and applying three coats of STARPROOF WF MB 602 single components rubberrized elastomeric highly waterproofing coating. It is cold applied liquid waterproofing membrance, specially designed from a blend of special water repelling fillers, minerals stabilizers and gelling agent. Apply by brush on the cleaned surface as directed by Engineer-in-charge.
Supplying, fitting and fixing Various Brand split air conditioner dismantling and re-installation charges as per direction E/I.
Supplying, fitting and fixing Gas charging charges up to 2 TR air conditioner as per direction E/I.
Supplying, fitting and fixing Gas top up charges as per direction E/I.
Supplying, fitting and fixing Normal Refrigerant piping up to 2 TR air conditioner as per direction E/I.
Supplying, fitting and fixing Soft Drain PVC blended pipe as per direction E/I.
Supplying, fitting and fixing of Reddy made outdoor unit bracket in direction of E/I.
Supplying, fitting and fixing Old refrigerant pipe tubular natal insulation as per direction E/I.
Supplying, fitting and fixing Extra indoor to outdoor unit comiunication wire as per direction E/I.
Supplying, fitting and fixing and instalation of Artist Painting in the Direction of E/I.
Supply and instalation Fibre Reinforced Polymer (FRP) Planters Box made of Reinforcement 450 GSM Glass Fibre and impregnated with Unsaturated Polyster Resin Top Coat coated with Gelcoat and Painted with high finish using best quality Polyurethane Paints of desired colors as per specification and direction of E/I.
Providing and Displaying Devil's Ivy (Epipremnum aureum) well developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Aglaonema well developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Zamioculcas zamifolia well developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Bromeliadswell developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Philodendron developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Peace lily developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Dracaena developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and Displaying Sanseveria developed fresh and healthy with good foliage, multy branch 30 to 45 cm height in 20 cm cement / plastic pot as per the Direction of E/I.
Providing and fixing 6 mm thick Green Ply/ Green Panel on existing door shutter Pasting with 4 mm Veneer of Green Decor Make at both side with all material and labour all complete (Excluding all fancy type fitting) as per building specification and direction of E/I.
Providing and fixing 30 mm thick Green Ply/ Green Panel on Flush door shutter and Pasting with 4 mm Veneer of Green Decor Make at both side with all material and labour all complete (including all fancy type fitting) as per building specification and direction of E/I..
Providing and fixing 12 mm thick plywood (Green Ply/ Green Panel) on existing door Frame and Pasting with 4 mm Veneer (Green Decor) with material and labour all complete (including all fancy type fitting) as per building specification and direction of E/I.
Supplying and installation of 8 mm thick Synthetic ribbed triple foot mat in 1 m width, with rubber backing, as per specification and direction of E/I.
Supplying of 3 Seater Chair Specification (Size 1750 x 605 mm) 1. Seat/Back – Plastic injection moulded seats back with good textured finish and good balance of stiffness and impact resistance incorporated virgin material. 2. Armrest/legs – Plastic injection moulded with textured finish high rigidity polyamide material to bear the desirable loads. 3. Centre beam – Ms square tube of 1.6 mm thickness processed furnished with powder coating. as per specification and direction of E/I. (Make :- Spacewood or Equivalent)
Modular Aluminium extrusions (Alloy 6060 as per European standards EN 755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet with Premium grade Anodizing (Thickness 15-20 microns, as per International standards), with Lifetime warranty under normal working conditions. Size 8 inches x 16 inches as per direction E/I.
S/F/F all height wall paneling of 19 mm thick water proof ply (centure panic Pine wood, ISI Mark,Termites) over 2"x1" aluminium section, 4 mm thick water proof veneer (green decor wood) finishing with malamine polished all complete including all taxes and royalty all complete as per building specification and direction E/I
S/F/F all height wall paneling of 19 mm thick water proof ply (Green / Green) 4 mm thick water proof veneer (green decor wood) finishing with malamine polished all complete including all taxes and royalty all complete as per building specification and as per direction E/I.
Supplying and installation of Sculpture in the Direction of E/I. (Medium :- Wood, Size 4' to 5') .
Supplying and Fixing of Following Antique Finished items (Make:- AKS, Godrej or Equivalent) as per direction E/I.
Mortice Lock 8"
Mortice Lock 6"
Hinge 5"
Aldrope 12"
Aldrope 10"
Handle 8"
Door Closer
Door Silencer
Door Stopper
Tower Bolt 8"
Tower Bolt 6"
Supply and installation of Metallic Perforated Dustbin. as per building specification and direction of E/l
Providing and fixing of 8 mm wooden laminate floor with 2 mm thick Kini Foam under layer (Make :- Action, Green, Deco foot or Equivalent.) as per direction E/I.
Providing and fixing of Door profile and Skirting (75 mm Height) as per direction E/I.
Supplying, fitting and fixing of Window Blinds in the direction of E/I.
Providing and laying Glazed Vitrified Tiles (Full Body Vitrified Tiles) floor tiles of size 600 x 600 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete as per direction E/I.
Providing and fixing Glazed Vitrified Tiles (Full Body Vitrified Tiles) wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Supplying, Fitting and Fixing of TABLE TOP BASIN (SIZE-525 X 415 MM) (FLSWHT- 5601) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of ANGULAR STOP COCK (FLS-CHR-5053N) in the Direction of E/I. (Make :- JAQUAR or Equivalent) as per direction E/I.
Supplying, Fitting and Fixing of PILLAR COCK WITH EXTENTION BODY (FUSCHR- 29021N) in the Direction of E/I. (Make :- JAQUAR or Equivalent) as per direction E/I.
Supplying, Fitting and Fixing of ORISSA PAN (SIZE-580 X 445 MM) (CNS-WHT- 451) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of CONCEALED CISTERN (JCS-WHT-2400) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of CONTROL PLATE (JCP-CHR-292415) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of 2 WAY BIB COCK (FUS-CHR-5041N1) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of HEALTH FAUCET (ALD-CHR-573) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of TOILET PAPER HOLDER (ACH-CHR-1153S) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of URINAL (SIZE-355 X 340 X 535 MM) (URSWHT-13263) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying,Fitting and Fixing of SENSOR MINI CONCEALED TYPE FLUSH URINAL(SNR-DTL-51083)in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of SOAP DISPENSOR(CAN-CHR- 1135N) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of BOTTLE TRAP(ALD-CHR-769L300X190) in the Direction of E/I.(Make :- JAQUAR or Equivalent)
Supplying, Fitting and Fixing of BOWL FOR COUPLE CLOSET WC(CNS-WHT-755S220NPPZ) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying,Fitting and Fixing of WALL HANG CISTERN FOR IWC (WHC-WHT-184NL) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Supplying,Fitting and Fixing of HAND DRYER(HDR-SAP-M99ACS) in the Direction of E/I.(Make:-JAQUAR or Equivalent)
Supplying, Fitting and Fixing of WALL HUNG WC WITH SEAT COVER(CNS-WHT-963SPP) in the Direction of E/I. (Make :- JAQUAR or Equivalent)
Providing and fixing on wall face unplasticised Rigid PVC 6" ( 150 mm ) rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, with all fitting ( band , tee, socket, ect )
Providing one coat of Zinc Primer with 2 coats of synthetic enamel paint with machine over old steel/ G.I. surface including preparing the surface after cleaning, removing dust, dirt, scales, smokes, grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specifications and direction of E/I
Add 12 % GST
Add 1% Labour Cess
M/S B D Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .