Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC 26 2 BHASKAR CIRCLE RATANADA JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹24.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.9 LRejected-Finance 6 VANARAI SHOPPING COMPLEX W E HIGHWAY GOREGAON E MUMBAI 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | ₹27.9 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹28.4 LRejected-Finance 2 SHANTI NAGAR SECTOR NO 3 HIRAN MAGRI UDAIPUR 313 002 | UDAIPUR | RAJASTHAN | 313002 | ₹28.4 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹28.7 LRejected-Finance C 24 1ST FLOOR PATPARGANJ INDUSTRIAL AREA EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | ₹28.7 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹33.7 LRejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹33.7 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | MPC ELECTRICALS AND ENGINEERS L3 | WM Energy and Lighting Pvt Ltd. L4 | SARASWAT ENGINEERING SERVICES L2 | M J ELECTRICALS AND ELECTRONICS L7 | Awasthi Electric Works L5 | Sachin Electricals L6 | MACH ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply of high-quality integrated LED linear light (suitable for recessed mounting inside the boom arrangement including mounting accessories) with length of 8 feet and inclusive of driver with a minimum system lumen of 7000Lm and system wattage not exceeding 80W (±5%) with a nominal system efficacy of minimum 110 lumen/watt. CCT of 5700K . The housing should be made up extruded aluminium non-corrosive with pressure die-cast aluminum end caps to with stand extreme environments and suitable nos of hanging wire of suitable length with clip for recessed mounting for 8 feet luminaire fitting. It should have opal white polycarbonate diffuser in order to ensure glare free illumination at the platform level. Ambient operating temperature of the range -10 deg C to +45deg C. . The driver must have over-voltage protection, short circuit protection, over load protection. . The luminaire must be EMI EMC compliant as per EN61547. The cable entry for the luminaire must be from the back of the luminaire through suitable gland. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. Luminaire and driver must have BIS certificate and the same must be submitted for records as per technical specification of LED light fitting of the tender document. Make -Phillips BY500B LED88S-865 PSU W7L240 OD WH S2, WiproLM34-801-AI Series or equivalent. | 350 | Nos | 6,560 ₹23.0 L | 3,964.8 ₹13.9 L | 5,861 ₹20.5 L | 8,888 ₹31.1 L | 7,500 ₹26.3 L | 4,600 ₹16.1 L | 5,399 ₹18.9 L |
| 2.00 | Installation, Testing, Commissioning of all types of above light fittings mentioned in BOQ item no 1.00 inside of terminal building double height area of height upto 10 mts. Including connecting of the fittings with existing wiring and necessary arrangements such as platform ladders or telescopic ladders and adherence to all required safety precuations, complete in all respects etc as required. | 350 | Nos | 710 ₹2.5 L | 2,312.8 ₹8.1 L | 359 ₹1.3 L | 100 ₹35,000 | 800 ₹2.8 L | 2,000 ₹7 L | 539 ₹1.9 L |
| 3.00 | Dismantling of light fitting inside terminal building double height area of height upto 10 mts. Including necessary arrangements such as platform ladders or telescopic ladders, shfting of dismantled light fixtures to the Basment or MLCP building or suitable place as per instruction of EIC at a distance approx 200 mtr and adherence to all required safety precuations, complete in all respects etc as required. | 430 | Nos | 350 ₹1.5 L | 991.2 ₹4.3 L | 718 ₹3.1 L | 300 ₹1.3 L | 600 ₹2.6 L | 2,000 ₹8.6 L | 290.5 ₹1.2 L |
| 4.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed B class GI conduit with 10 amps rating, SP MCB, "C" curve of 10 KA breaking capacity and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C | 50 | Point | 1,430 ₹71,500 | 1,652 ₹82,600 | 2,177 ₹1.1 L | 1,400 ₹70,000 | 1,600 ₹80,000 | 1,500 ₹75,000 | 1,792 ₹89,600 |
| 5.00 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed GI conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C | 100 | Point | 710 ₹71,000 | 1,652 ₹1.7 L | 1,970 ₹2.0 L | 1,000 ₹1 L | 1,300 ₹1.3 L | 1,300 ₹1.3 L | 1,030 ₹1.0 L |
Tender Value
₹39.3 L
EMD Value
₹1.2 L
Closing Date
17 Dec 2025, 6:00 pmClosed
AGM (E-E), AAI, Goa Airport
AGM (E-E), AAI, Goa International Airport, Dabolim, Goa
SITC of various LED Lights at Goa Airport
2025_AAI_256400_1
AAI/GOA/EE-E/LED/NIT-09/25-26
Open Tender
Electrical Works
180 days
Goa International Airport
As per NIT
17 documents required · 17 mandatory
₹1,180
₹1.2 L
10 Mar 2026
25 Nov 2025
18 Dec 2025
26 Nov 2025
17 Dec 2025
26 Nov 2025
26 Nov 2025 - 30 Nov 2025
Supply of high-quality integrated LED linear light (suitable for recessed mounting inside the boom arrangement including mounting accessories) with length of 8 feet and inclusive of driver with a minimum system lumen of 7000Lm and system wattage not exceeding 80W (±5%) with a nominal system efficacy of minimum 110 lumen/watt. CCT of 5700K . The housing should be made up extruded aluminium non-corrosive with pressure die-cast aluminum end caps to with stand extreme environments and suitable nos of hanging wire of suitable length with clip for recessed mounting for 8 feet luminaire fitting. It should have opal white polycarbonate diffuser in order to ensure glare free illumination at the platform level. Ambient operating temperature of the range -10 deg C to +45deg C. . The driver must have over-voltage protection, short circuit protection, over load protection. . The luminaire must be EMI EMC compliant as per EN61547. The cable entry for the luminaire must be from the back of the luminaire through suitable gland. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. Luminaire and driver must have BIS certificate and the same must be submitted for records as per technical specification of LED light fitting of the tender document. Make -Phillips BY500B LED88S-865 PSU W7L240 OD WH S2, WiproLM34-801-AI Series or equivalent.
Installation, Testing, Commissioning of all types of above light fittings mentioned in BOQ item no 1.00 inside of terminal building double height area of height upto 10 mts. Including connecting of the fittings with existing wiring and necessary arrangements such as platform ladders or telescopic ladders and adherence to all required safety precuations, complete in all respects etc as required.
Dismantling of light fitting inside terminal building double height area of height upto 10 mts. Including necessary arrangements such as platform ladders or telescopic ladders, shfting of dismantled light fixtures to the Basment or MLCP building or suitable place as per instruction of EIC at a distance approx 200 mtr and adherence to all required safety precuations, complete in all respects etc as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed B class GI conduit with 10 amps rating, SP MCB, "C" curve of 10 KA breaking capacity and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed GI conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tenderdocument.pdf
Tender Documents • 11.95 MB
BOQ_295979.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid