Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 LAccepted-Finance | 1 | Accepted-Finance Single Fin Bid found in order |
Tender Value
₹1.6 L
EMD Value
₹3,210
Closing Date
16 Jan 2023, 6:00 pmClosed
Executive Engineer Civil
BSNL Civil Division,BSNL Bhawan, PanBazar Guwahati
-Misc. civil Repair works in Staff Qtrs. Compound at Rangia under Kamrup BA,Guwahati.
2023_BSNL_140962_1
e-NIT No.66/BSNL/CDGH/2022-23
Open Tender
Civil Works - Buildings
Item Rate
60 days
Rangia BSNL Campus
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO Cash O/o GMTD, BSNL Kamrup SSA, Guwahati
₹3,210
18 Jan 2023
9 Jan 2023
18 Jan 2023
9 Jan 2023
16 Jan 2023
9 Jan 2023
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3coarse sand), cost of required centering complete.
1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5°
110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1cement: 4 coarse sand).
Renewing glass panes and refixing existing wooden fillets:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge.
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe
32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia. Pipes.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
40 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length
15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
100 mm diameter
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
25 mm nominal bore.
40 mm nominal bore.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and fixing PTMT grating of approved quality and colour. Circular type.
100 mm nominal dia.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
25 mm nominal bore, 152 mm long. Weighing not less than 440 gms.
Cleaning of Septic tank & Removal of Sewage by Mechanical suction pump and desludging of all sludge, solid waste, dirt, night soil etc. manually including cleaning of Inlet & outlet Chambers & Invert pipes including disposal of all removed materials to the dumping ground out of municiple limits et. Complete all as directed by Engineer-in-charge.
Cleaning of Manhole chambers of any size by removing sludge , dirt, malba & flushing with water including disposal of waste to Municipal corporation dumping places etc.complete as directed by Engineer in charge.
Cleaning of surface drain of sizes specified below including removal of debris and staching it along the length ( disposal of dried debris will be paid in relevent head) and replacing the covers if any after completion of the work properly & spraying beaching & lime powder to make the area hygenic upto the satisfaction of the Engineer-in -charge
Drain cross section @ 250X300 mm
Easining of door windows shutter by by taking it out if necessary and oiling the hinges and plaining the edges as necessary including minor repairs by use of cleat angle etc to make doors and window shutters easily operable complete as per direction of Engineer-in-charge. ( payment will be made on shutter basis)
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Providing & erecting single scaffolding system on the external side of building upto three storey height made of best quality bamboo ballies @ 1.5 m centre to centre in both directions including bracing & stiffening as required.
shifting & refixing available scaffolding materials to other locations along external side of the building inside the same compound for height upto three storeys & for facilitating execution of other maintenance operations as per direction of E.I.C.
Supplying & engaging unskilled labour along with T&P for cleaning of roof, chajja, rain water pipe mouth, drains & removing trees & plants etc as & when directed by Engineer-in-Charge.
Chipping of Roof surface i/c removal of Loose concrete and sisposal of the same outside the compound and making the roof readdy for laying concrete all complete as directed by Engineer-in-Charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .