| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical 441 190 A SIDDIQUI HOUSE MALAPURAM COLONY JAL NIGAM ROAD BALAGANJ LUCKNOW UTTAR PRADESH 226003 | LUCKNOW | UTTAR PRADESH | 226003 | Rejected-Technical Not meeting Prequalifying requirement |
Tender Value
Refer Docs
EMD Value
₹6,600
Closing Date
19 Dec 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer (EWCL)
Type-IV/3, Transmission Staff Colony Dewa Road, Chinhat Lucknow
Increasing Capacity of 33/11 KV S.S, Pali, EDD-Sahabad, Hardoi from 2x5 MVA to 1x5 Plus 1x8 MVA T/F
2022_MVVNL_755238_1
13/EWCL/2022-23
Open Tender
Electrical Works
Fixed-rate
90 days
33/11 KV Sub-Station Pali, EDD-Sahabad
As per Tender Documents
2 documents required · 2 mandatory
₹1,180
A/c No. 0758002100009592, IFSC PUNB0586800
₹6,600
11 Jan 2023
1 Dec 2022
19 Dec 2022
1 Dec 2022
19 Dec 2022
1 Dec 2022
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from any Electy.Store of Lucknow Zone to JE's dump store and from store to work site:
33/11 KV 8 MVA Transformer (from 33 /11 KV S/S Bastauli lakhimpur site to 33/11 KV S/S Pali Hardoi )
33 KV VCB 800 Amp., 750 MVA
33 KV CT 200/100/1 Amp.
33 KV Single T/F Control Pannel with structure.
11 KV VCB O/G CTR 200/100/5 AMP, 350 MVA
11 KV 3x300 SQ MM XLPE
11 KV 3x120 SQ MM XLPE
MS Channel 125x65x6 mm
MS Angles 75x75x8 mm
33 KV Post Insulator
33 KV Lightening Arrester
11 KV 3x300 SQ MM XLPE Cable Outdoor
11 KV 3x300 SQ MM XLPE Cable Indoor
11 KV 3x120 SQ MM XLPE Cable Outdoor
11 KV 3x120 SQ MM XLPE Cable Indoor
Dismantling of 33/11 KV 5 MVA T/f after drain out of conservator & Radiator oil and proper stacking at safe place.
Plinth of 8 MVA 33/11KV T/F: Repairing of existing 5 MVA T/F plinth for 8 MVA T/F.
Repairing of 8 MVA Transformer
Opening of radiator tank top cover and replacement of all gaskets kit set complete to avoid leakage then proper cleaning and reassembling .
Centrifuging of 8 MVA Transformer Oil by Centrifuging machine (Centrifuging machine provided by the contractor)
Repairing of Tap changer of 8 MVA Transformer
Replacement of damaged breather with silica gel & MOG
Proper cleaning , repairing / replacement of HT/LT Bushing with rod
Erection and installation of 33/11KV 8 MVA T/F
Erection and installation of 33/11KV 8 MVA T/F in a levelled position of the plinth. The work includes shifting of T/F to the site & installation within the S/S premises, assembling, fixing and fitting of all accessories and filling of T/F oil to the desired level and ensuring that there is no leakage. All jumpering & connection are included in the scope of work including commissioning & testing.
Earthing for power T/F by way of boaring and lowering of 40mm dia, 2.9 mm thick GI Pipe from ground upto the water level (minimum 60 feet deep) as per standard practice as per REC Drg.
Fabrication of 33 KV CT Structure : Fabrication of 33 KV CT Structure 3.5 mtr. in height as per Drg. digging of two no pits of size 1.075x0.9x0.3 mtr. providing stone pad at the bottom of the pit and grouting of two legs of the Structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of .3x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the structure shall be properly finished with smoothing of edges.
Installation of CT: Installation of 3 No.(1 set) CT on the CT Structure along with CT Junction Box. The work includes fabrication for proper fixing of C.T. If required and proper commissioning & testing.
Installation of P.I. & Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A. & Post insulator on the L.A & P.I. Structure/complete with making earth connections (separate) and line connections. The work includes fabrication for fixing if required.
Plinth of VCB : Construction of Plinth of size 2.0 mtr x1.5mtr x0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:3:6 (cement, find sand & brick ballast) 1st class brick work in cement mortor ratio 1:4:8 (cement, coarse sand and stone grit of 20mm gauge).
Installation of VCB: Installation of 33KV VCB complete work including commissioning & testing.
Shifting carefully & installation safely 11KV O/G switchgears from outside the switchgear room placing and fixing of switchgear on foundation providing G.I. Bolt & Nuts of proper size in proper position and alignment and checking, complete work with mounting of P.T. on incoming S/G with proper testing & commissioning of switchgears.
Fixing and making Bus Bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work as per satisfaction of site incharge.
Shifting carefully and installation of 33KV Single Transformer Control Panel in Control Room including fixing, bolting & grouting of above as per requared and testing, commisioning satisfaction of site incharge.
HT Cable Laying :
Laying & dressing of 11KV 3x300 Sq.mm U/G cable from 8 MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All the material to be provided by the contractor Except cable).
Laying & dressing of 11KV 3x120 Sq.mm U/G cable from 11KV Outgoing Switchgear to 11 KV outgoing DP by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below & above the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All the material to be provided by the contractor Except cable).
Hoisting of 11KV Cable with 100 mm dia 3 Mtr. long GI Pipe on the feeder cable before mounting the cable on the double pole, lifting, mounting and clamping of 11KV feeder cable boxes on the feeder double pole structure and making connection including supply of cable mounting clamps. The work includes the sealing of GI Pipes, lower end of the pipe is to be buried into the earth by about one foot. (All the material to be provided by the contractor Except cable).
Hoisting of 11KV Cable for 11 KV switchgears & 33/11KV T/F.
Supply and laying of following size Copper Control Cable through underground/cable trench/trenching SGR interlinking through proper connections to T/F Control panel/protection board/Battery and Battery Charger/Bunch joints, Relay 33/11KV T/F junction Box/33KV VCB, CTs etc. as per site conditions:
6x2.5 Sq.mm
4x2.5 sq.mm
2x2.5 sq.mm
Painting of all structures and equipments.
Reparing and Replacement of 33 KV existing Bus bar with the help of PG Clamp, Isolator Clamp, and CT Connector. (All the material to be provided by the contractor Except cable).
Earthing of 11 KV, 33 KV Switchgears & Equipment: Earthing of 11 KV, 33 KV Switchgears equpiment by lowering and boring of Chemical Earthing outsite of switchyard and connecting through G.I. Strip 50x6mm with indoor/outdoor equipments. (All the material provided by the contractor)
Earthing of old existing & new erected structure & Equipments through M.S. strip 50x6 mm with MS earth mat. (G.I. strip 50x6 mm etc provided by contractor)
A. A. ENGINEERING CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .