| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L1 | Accepted-AOC LOWEST BID VALUE | |
| 2 | L2₹48.6 L+₹12.2 L (33.5%)Rejected-Finance | L2 | Rejected-Finance HIGHER BID VALUE | |
| 3 | L3₹50.8 L+₹14.4 L (39.5%)Rejected-Finance 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | L3 | Rejected-Finance HIGHER BID VALUE | |
| 4 | L4₹73.0 L+₹36.6 L (100.7%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L4 | Rejected-Finance HIGHER BID VALUE | |
| 5 | L5₹75.1 L+₹38.7 L (106.3%)Rejected-Finance | L5 | Rejected-Finance HIGHER BID VALUE |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
30 Mar 2021, 6:55 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA , KALAIKUNDA AIR FIELD POST, DIST, WEST MEDINIPORE,721303
PROVN OF BUILDING INCLUDING EXTERNAL SERVICES FOR PACKAGE TYPE AIR CONDITIONER IN OT AND ICU
2021_MES_414643_2
8329(A)/KKD/04/E8
Open Tender
Civil Works
Lump-sum
150 days
AT AF STN KALAIKUNDA
Class D, category a(I)
2 documents required · 2 mandatory
₹500
Yes
GE AF KALAIKUNDA
₹77,000
Yes
4 Sept 2021
6 Mar 2021
1 Apr 2021
6 Mar 2021
30 Mar 2021
16 Mar 2021
6 Mar 2021 - 11 Mar 2021
Amount
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of room for AHU of OT with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of room for AHU of ICU with permanent specification complete all as specified and shown in drawing.
Total amount of Sch 'A' Part-II (Site clearance and earthwork) Prepriced amount B/F from Sl page No. 25
Total amount of Sch 'A' Part-III (Internal Electrification) Prepriced amount B/F from Sl page No. 27
Total amount of Sch 'A' Part-IV (Internal water supply) Prepriced amount B/F from Sl page No. 28
Total amount of Sch 'A' Part-V( External electric supply ) Prepriced amount B/F from Sl page No. 30
Total amount of Sch 'A' Part-VI( Sewage disposal) Prepriced amount B/F from Sl page No. 32
Total amount of Sch 'A' Part-VII (Road / Path) Prepriced amount B/F from Sl page No. 33
Total amount of Sch 'A' Part-VIII (Special item) Prepriced amount B/F from Sl page No. 35
Total amount of Sch 'A' Part-IX (Misc work) Prepriced amount B/F from Sl page No. 37
Sch 'A' Part-XI (Misc Items) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
S&F LED 18 Watt tube light fitting (T8 type) ,single end connection type LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj (Batten BLRB-DB-118 box type batten suitable for 18 watt retofit LED tube single side connection type). LED lamp 18 Watt complete all as specified and as directed NOTE:-Box type batten and LED tube shall be of same make
S&F LED bulkhead light of 10W with polycarbonate body and diffuser , IP-65, PF>0.95 complete all as specified and directed by Engineer in charge.
Supply and fixing lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box including supply and fixing 11 watt LED lamp. Make For holder complete all as specified and directed by Engineer in charge.
S&F LED building security light fittings of 60 Watts LED made up of die cast housing with toughed glass and individual LEDs with secondary optics and IP 66 protection , including mounting bracket of 40 mm light grade GI pipe of suitable length fixed on wall complete all as specified and as directed by Engineer-in-Charge. Note:- All LED street light shall be properly connected with earth dolly provided with fittings
S&F MCB SP 240 volts 10 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-In-Charge
S&F MCB DP 20 Amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs including taking down u/s complete all as specified and directed by Engr-In-Charge
Supply and fixing Exhaust fan 300 mm sweep, metal body, with bird screen & double ball bearing powerful and energy efficient motor , single phase , 240 volt ,50 Hz , AC complete all as specifiedand as directed.
Supply , installation , testing and commissioning of Automatic Servo controlled voltage stabilizer(Confirming to BIS 9815:Part1-1994) Three phase , 50 Hz , Naturally oil cooled , copper wound , indoor type , metallic body duly powder coated with lifting hooks two nos ,digital display type , relay free smooth and silent operation , efficiency more than 95% with over load/short circuit protection , high/low voltage cut off , by pass arrangement in case of emergency & designed for input variation between 300V to 480V with output voltage stabilizer at 415V with accuracy± 2.5% and speed of correction 8 Volts per second and of capacity 50 kVA. complete all as specifiedand as directed. NOTE:-Contractor has to be submit general arrangement drawing of stabilizer and take approval of GE before placing the order for procurement
M & L for Fly ash bricks of size 250 mm X 120 mm X 70 mm laid in trenches as in protection of under ground cables all as specified and directed.
Supply,installation,testing and commissioning LT panel board suitable for working on 3 phase,4 wire, 415 volts, AC, 50Hz, Outdoor type, cubicle, floor mounted,dust and vermin proof, with IP-64 protection fabricated out 3.15mm thick CRCA sheet duly powder coated painting,CPRI approved,front and rear opening with locking arrangement, cable alleys, bus bar (400 Amp capacity) chamber and switch gear compartments,copper bus bar duly covered with heat shrinkable sleeves color coaded fixed on DMC/SMC insulators bottom cable entry hole for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of approprite rating by cable lugs,thmbles etc.Earthing terminals,affixing danger notice plate,
Item no 21 Cont…. each compartment shall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length,control fuses/MCBs and PCC foundation(1:3:6) as per site requirement and a clear space to be kept from bottom of panel for proper termination of cable and including cable connection to MCCBs,switch gear with necessary cable glands,lugs,nut,bolts and washer etc, complete all as specified and directed including comprising of following.(Proposed Main AC Panel-P1) (a) MCCB 160Amp,Thermal magnetic release, 4 Pole, 35 kA, 415 volts, AC, 50Hz - 01 No ( I/C) (b) MCCB 63 Amp,Thermal magnetic release, 4 Pole, 25 kA, 415 volts, AC, 50Hz - 03 No ( O/G 2W+1S)
Item no 21 Cont… .(c) MCB 40Amp, 4 Pole, 18 kA, 415 volts, AC, 50Hz - 01 No (O/G) (d) MCB 10Amp, 2 Pole, 10 kA, 220 volts, AC, 50Hz - 01 No (O/G) (e) Indicating Lamp - 01 set (03Nos) (f) Ammeter 0-300 volts with CTs and slector switch - 01 No (g) On load Changeover Switch 250Amp, 4P,Conforms IS/IEC 60947-3 - 01No NOTE:- (i) Contractor has to submit the drawing of LT panel and take approval of GE before placing the order for fabrication of panel. (ii) All MCCB’s in above item shall be characteristics of thermal magnetic release type, Ics = 100% Icu, with adjustable overload and short circuit setting including providing spreader terminals and phase barriers.
Supply,installation,testing and commissioning LT panel board suitable for working on 3 phase,4 wire, 415 volts, AC, 50Hz, Indoor type, cubicle, floor mounted,dust and vermin proof, with IP-54 protection fabricated out 2 mm thick CRCA sheet duly powder coated painting,CPRI approved,Front and rear opening type with provision of cable alley on both (incoming and outgoing) side. with locking arrangement, cable alleys, bus bar (200 Amp capacity) chamber and switch gear compartments,copper bus bar duly covered with heat shrinkable sleeves color coaded fixed on DMC/SMC insulators bottom cable entry hole for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of approprite rating by cable lugs,thmbles etc.Earthing terminals,affixing danger notice plate,each
Item no 22 cont... compartmentshall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length,control fuses/MCBs and PCC foundation(1:3:6) as per site requirement and a clear space to be kept from bottom of panel for proper termination of cable and including cable connection to MCCBs,switch gear with necessary cable glands,lugs,nut,bolts and washer etc, complete all as specified and directed including comprising of following.(Proposed ICU Panel P-2) (a) MCCB 100 Amp,Thermal magnetic release, 4 Pole, 35 kA, 415 volts, AC, 50Hz - 01 No ( I/C) (b) MCCB 63 Amp,Thermal magnetic release, 4 Pole, 25 kA, 415 volts, AC, 50Hz - 02 No ( O/G 1W+1S)
Supply,installation,testing and commissioning LT panel board suitable for working on 3 phase,4 wire, 415 volts, AC, 50Hz, indoor type, cubicle, floor mounted,dust and vermin proof, with IP-63 protection fabricated out 2 mm thick CRCA sheet duly powder coated painting,CPRI approved,Front and rear opening type with provision of cable alley on both (incoming and outgoing) side with locking arrangement, cable alleys, bus bar (300 Amp capacity) chamber and switch gear compartments,copper bus bar duly covered with heat shrinkable sleeves color coaded fixed on DMC/SMC insulators bottom cable entry hole for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of approprite rating by cable lugs,thmbles etc.Earthing terminals,affixing danger notice plate,each
Item no 23 cont... compartment shall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length,control fuses/MCBs and PCC foundation(1:3:6) as per site requirement and a clear space to be kept from bottom of panel for proper termination of cable and including cable connection to MCCBs,switch gear with necessary cable glands,lugs,nut,bolts and washer etc, complete all as specified and directed including comprising of following.(Proposed OTs Panel- P3) (a) MCCB 160Amp,Thermal magnetic release, 4 Pole, 35 kA, 415 volts, AC, 50Hz - 01 No ( I/C) (b) MCCB 63 Amp,Thermal magnetic release, 4 Pole, 25 kA, 415 volts, AC, 50Hz - 03 No ( O/G 2W+1S)
Supply and fixing of MCCB 250 Amp 4 pole 415 V, 35KA, 50HZ, thermal magnetic release type, Ics = 100% Icu with adjustable overload and short circuit setting including providing spreader terminals and phase barriers. MCCB to be installed in existing panel including making all connections complete all as specified and directed by Eng-in-charge.
M & L for Earthing complete with copper earth plate 60 cm X 60 cm X 3.15 mm thick, buried directly in ground (earth pit not less than 3.25 metres deep below ground level) with top edge of the plate not less than 2.5 metres below normal ground level, connected to copper strip 20 X 3 mm as earth lead by means of bolts, nuts, check nuts and washers of brass and as shown in electrical plate No. 3 connected to earthing test point including necesary excavation any type of soil , RCC chamber cover plate , wire mesh , funnel ,test point , 50 mm dia GI pipe light grade for protection pipe and watering etc complete and testing on completion. Note:- Copper strip upto 7.5 RM will be included in the item rate and copper strip beyound 7.5 RM will be measured seperately.
M & L for manual boring of hole under road,pavement,hard standing by required T & P without disturbing the top surface of existing area for throughing the cable in GI pipe of 80-100 mm dia complete all as specified and directed.
S&F 4mm thick ACP panels fixed to walls including aluminium frame work complete all as specified and directed.
Removing of tree roots for preventing the regrowthing and making good the disturbed earth complete all as specified & directed by Engr- in -Charge.
M&L for thermal insulation of AHU Room wall and roof by providing nitrile rubber insulation of 19 mm thickness with aluminium foil face insulation with stainless steel wire mesh of 0.71 mm dia , 12 mm aperture over it complete all as specified and directed by Engr-in-charge.
S&F digital thermometer for monitoring the temperature in both OT & ICU complete all as specified and directed by Engr-in-charge.
M&L for fire stand of suitable size made out of MS angle iron/ chanel and painted with synthetic enamel paint over a coat of red oxide primer and letter writing with white paint including and providing followings, complete all as specified and directed by Engr-in-charge. (a) Galvanized MS fire buckets 14 Litr capacity -2 No (b) potable fire extinguisher abc type 3 kg capacity-2 Nos
S&F of normal wet bulb thermometer and dry bulb thermometer complete all as specified and directed by Engr-in-charge.
Ganguly Construction
STAR ENTERPRISES
Guru Charan Mahata
BHOWMICK ENTERPRISES INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .