| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC C141 SUN CITY SECTOR 35 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹2.6 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.6 Cr+₹7.9 L (3.10%)Rejected-AOC NA | ₹2.6 Cr+₹7.9 L (3.10%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹2.7 Cr+₹9.8 L (3.85%)Rejected-AOC 161 VPO RAJLU GARHI GANAUR 131101 | SONIPAT | HARYANA | 131101 | ₹2.7 Cr+₹9.8 L (3.85%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹2.8 Cr+₹24.1 L (9.42%)Rejected-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | ₹2.8 Cr+₹24.1 L (9.42%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹2.9 Cr+₹32.5 L (12.7%)Rejected-AOC | ₹2.9 Cr+₹32.5 L (12.7%) | L5 | Rejected-AOC Rejected |
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
4 Sept 2023, 12:00 pmClosed
ROHIT KUMAR
EE PHE Division No. 1 Rohtak
Construction of Raw water Pump house, SETC horizontal casing Raw water Pumping set, Prov. and Installation of Transformer, DG Set, Electrical installation / cables, Suction/ delivery Special all other works as per approved DNIT.
2023_HRY_306442_1
2023DD55F0BA 6AF5 4194 BBF2 70F38C74E178576PUH
Open Tender
Civil Works
Works
365 days
Kalanaur
Enlistment Certificate of appropriate Class from PHED and Login Account on HEW Portal.
8 documents required · 8 mandatory
₹15,000
₹5.9 L
Yes
23 Oct 2023
25 Aug 2023
4 Sept 2023
25 Aug 2023
4 Sept 2023
25 Aug 2023
25 Aug 2023 - 25 Aug 2023
Amount
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : Make IVC/VAG (500 mm i/d )
H.T METER: Provision for HT metering Panel along with VCB, entire cable network and all other required electrical items complete in all respect.
Supply, erection, testing of 3.5 core aluminum cables with ISI marked for making connection with LT Bus Bar and LT Panel Board to electric motor and other electric appliance with underground system in PVC / flexible pipes/ cable tray with all required accessories like thimble etc. as directed by Engineer-in-Charge complete in all respect. 300 Sqmm 3.5 core
SITC of copper Cable 120 Sqmm Single core copper Cable for Panel to Pumps.
Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : 400 mm dia C.I. Double Flanged Pipe
Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : 600 mm dia C.I. Double Flanged Pipe
Supply, Laying, testing Commissioning for NRV at Pipeline of IVC VAG make PN 1.6 Size 300 mm
RAW WATER PUMP: - Supplying, erection, testing and commissioning of Horizontal split casing type pumping sets minimum four (4) Star rating duties coupled to AC squirrel cage induction type motor with 1440 RPM 3 phase 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame as per approved DNIT. Motor pumping set for Raw Water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked 12600 LPM X 50 M X 235.00 HP.
NS Item -Panel Board - Supply, erection, testing and commissioning of floor mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron framework and completely powder coated of suitable size having following items for Horizontal split casing pump set of suitable for 2 Nos. pumping set 12600 LPM with 50 Mtr. Head Horizontal split casing pump set and required accessories: - ` Cost of material as per market rates:- (Incomer) 1. MCCB 630A TP MCCB 50 KA Motor backup Protection Duty = 1 Nos. 2. Indicator Indicating Lamp R/Y/G 230 V = 3 Nos. 3. M/F Multifunction meter digital type = 1 Nos. 4. MCB 6Amp. control MCB = 3 Nos. 5. CT 200/5Amp. Class 1.0 10VA = 3 Nos. 6. Relay under Voltage Relay = 1 Nos. (Outgoing section) 1. MCCB 300 a TP MCCB 50 KA Motor Backup Protection Duty = 2 Nos., 2. Contactor MNX 300A TP Power contactor AC2 2NO plus 2NC = 4 Nos., 3. Contactor MNX 185A TP Power contactor AC2 2NO plus 2NC = 1 Nos., 4. Relay Microprocessor based overload relay 150-300Amp = 2 Nos., 5. Timer On delay Timer (Star Delta) = 2 Nos., 6. Push button (On, Off) = 4 Nos., 7. Indicating Lamps, LED Type (On, Off, Trip) = 6 Nos., 8. Auxilary Contactor 2NO plus 2NC 240V AC = 4 Nos., 9. Preventor Single Phasing Relay = 2 Nos., 10. Automatic Power Factor Control Panel 150 kVAR = 1 Nos., 11. Hardware/ Miscellaneous, 12. Enclosure (1800x1800x400 mm, 13. Wire, 14. Wiring / Margin/ Busbar (Al.) (Note: - All accessories should be design load of motor).
NS Item -Panel Board - Supply, erection, testing and commissioning of floor mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron framework and completely powder coated of suitable size having following items for Horizontal split casing pump set of suitable for 3 Nos. pumping set 12600 LPM with 50 Mtr. Head Horizontal split casing pump set and required accessories: - ` Cost of material as per market rates:- (Incomer) 1. MCCB 630A TP MCCB 50 KA Motor backup Protection Duty = 1 Nos. 2. Indicator Indicating Lamp R/Y/G 230 V = 3 Nos. 3. M/F Multifunction meter digital type = 1 Nos. 4. MCB 6Amp. control MCB = 3 Nos. 5. CT 200/5Amp. Class 1.0 10VA = 3 Nos. 6. Relay under Voltage Relay = 1 Nos. (Outgoing section) 1. MCCB 300Amp TP MCCB 50 KA Motor Backup Protection Duty = 3 Nos. 2. Contactor MNX 300A TP Power contactor AC2 2NO plus 2NC = 6 Nos. , 3. Contactor MNX 185A TP Power contactor AC2 2NO plus 2NC = 3 Nos, 4. Relay Microprocessor based overload relay 180-300Amp = 3 Nos. , 5. Timer On delay Timer (Star Delta) = 3 Nos. , 6. Push button (On, Off) = 6 Nos. , 7. Indicating Lamps, LED Type (On, Off, Trip) = 9 Nos. , 8. Auxilary Contactor 2NO plus 2NC 240V AC = 6 Nos. , 9. Preventor Single Phasing Relay = 3 Nos. , 10. Automatic Power Factor Control Panel 150 kVAR = 1 Nos., 11. Hardware/ Miscellaneous 12. Enclosure (1800x1800x400 mm , 13. Wire 14. Wiring / Margin/ Busbar (Al.) , (Note: - All accessories should be design load of motor).
Less Credit for old RCC NP2 pipe 800 mm i/d including cost of removing etc. complete in all respect.
Bidder Name
Amount
Lalit Kumar(GSTN-06ALGPB5309Q1ZY)
RAJKUMAR(GSTN-06BMEPK8901M1ZS)
Sunil Kumar Contractor(GSTN-06ANBPK3767E1Z5)
M/S SHREE BALAJI BUILDERS(GSTN-NA)
Mukesh Rathee contractor(GSTN-NA)
Sh. Ashok Kumar Sindhu(GSTN-NA)
M/S SHREE BALAJI BUILDERS
Sh. Ashok Kumar Sindhu
RAJKUMAR
Sunil Kumar Contractor
Mukesh Rathee contractor
Mukesh Rathee contractor
Sh. Ashok Kumar Sindhu
Sunil Kumar Contractor
Lalit Kumar
M/S SHREE BALAJI BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .