| Sl No | Description | Qty | Unit | SARAN BUILDWELL PVT. LTD. L2 | NAV BHARAT BUILDCON PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | P and amp;F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia | 175 | Per Mtr. | 308 ₹53,900 | 305 ₹53,375 |
| 2.00 | P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Socket plug 110mm dia | 14 | Each | 89 ₹1,246 | 88 ₹1,232 |
| 3.00 | P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia | 14 | Each | 176 ₹2,464 | 174 ₹2,436 |
| 4.00 | P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Plain Tee 110mm dia | 7 | Each | 204 ₹1,428 | 202 ₹1,414 |
| 5.00 | P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: W.C. connector bent type 110mm dia | 7 | Each | 243 ₹1,701 | 241 ₹1,687 |
| 6.00 | P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Reducer 110 X 75 mm 110mm dia | 7 | Each | 106 ₹742 | 105 ₹735 |
| 7.00 | Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia 90 Cm and amp; 10 to 12 Mtr deep. | 7 | Each | 5,972 ₹41,804 | 5,917 ₹41,419 |
| 8.00 | P and amp; F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe and amp; 25 Cm. long wash out pipe with plug and amp; socket, including making connection etc., complete of approved design: 1000 litres capacity. | 7 | Nos | 8,547 ₹59,829 | 8,469 ₹59,283 |
| 9.00 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit and amp; its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Medium point (up to 6 mtr.) | 35 | Per Point | 630 ₹22,050 | 625 ₹21,875 |
| 10.00 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering and amp; ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils | 233.45 | Cum | 194 ₹45,289.30 | 250 ₹58,362.50 |
Tender Value
₹35.8 Cr
EMD Value
₹71.6 L
Closing Date
9 Oct 2023, 6:00 pmClosed
Additional Chief Engineer Water Resources Zone Uda
Office of Additional Chief Engineer Water Resources Zone Udaipur
Rehabilitation of Udai Sagar Medium Irrigation Sub Project District Udaipur
2023_WRDAS_367781_1
ACE 32 of 2023-24
Open Tender
Civil Works
1095 days
Executive Engineer WR Division Udaipur
as per Technical bid
5 documents required · 5 mandatory
₹10,000
Executive Engineer WR Division Udaipur
₹71.6 L
Udaipur
14 Dec 2023
18 Sept 2023
10 Oct 2023
18 Sept 2023
9 Oct 2023
18 Sept 2023
29 Sept 2023
Amount
P and amp;F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Socket plug 110mm dia
P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia
P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Plain Tee 110mm dia
P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: W.C. connector bent type 110mm dia
P and amp;F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Reducer 110 X 75 mm 110mm dia
Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia 90 Cm and amp; 10 to 12 Mtr deep.
P and amp; F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe and amp; 25 Cm. long wash out pipe with plug and amp; socket, including making connection etc., complete of approved design: 1000 litres capacity.
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit and amp; its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Medium point (up to 6 mtr.)
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering and amp; ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:4 ( 1-Cement : 4-Sand).
Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:4 ( 1-Cement : 4-Sand).
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course with cement concretee grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick.
Centering and amp; shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the billets to produce steel conforming to IS:1786) Hot rolled deformed bars (IS : 1139).
Providing and laying in position specified grade of cement concretee for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
P and amp; F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absorption less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit and amp; its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Short point (up to 3 mtr.)
Providing and amp; Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf 0.95 , CRI and gt;70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. - 18/20 Watt
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit and amp; its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets and amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05 and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Long point (up to 10 mtr.)
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12mm thick .
P and amp;F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 75 mm dia
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) : Flush / Ruled/ Struck or weathered pointing.
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concretee block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable)
Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 75mm dia. Pipes.
Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
Providing and laying in position cement concretee including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
P and amp; F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) and amp; MS clamps including cutting and making good the walls and floors: Exposed on wall 15 mm dia nominal bore B Class
P and amp; F Bib Cock (IS : 8931 Mark), Superior quality of approved make: Brass 400 gm,15mm nominal bore.
P and amp; F Stop Cock (IS :8931 Mark), superior quality and amp; of approved make: Brass 400 gm. 15mm nominal bore.
P and amp; F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 15mm nominal bore.
P. and amp; F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest.) Size 510 mm
P and amp; F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS : 7231 .
Supplying and drawing FR PVC insulated and amp; unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
Supplying and drawing FR PVC insulated and amp; unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 6.0 sq.mm
Providing and amp; Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A and amp; above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports and amp; All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) - 40 A rating
Providing and amp; Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A and amp; above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports and amp; All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) - 6 A to 32 A rating
Providing and amp; Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body and amp; Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; and amp; Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . - 1200 mm Sweep BEE 1 Star rated (service value and gt;=4.0 to and lt; 4.5 )
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect.Phylite and other hard rock requiring nominal blasting
Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level In hard rock (Blasting prohibited) Depth upto 1.5 m
Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level In hard rock (Blasting prohibited) Add extra for over all depth of excavation above 1.5 m and upto 3.0 m
Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicable taxes and levies etc. complete in all respect Earth / Soil
(i) Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of.at least 95% of Standard Proctor s density
Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 5.17.1 Deduct in item no 16 (a) to (d) above if Standard Proctors density to be achived is at least 95%
Watering of earth including cost of carriage of water when source of water is up to 1 Km
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect.Hard rock not requiring blasting
Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect. Soft / Disintegrated rock
Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil
Cutting and clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Ordinary
Providing and Laying in position of Cement concrete Design mix M-30 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; (For mix design Cement content considered 428 kg/ cum of concrete) 20 mm
Nominal mix of Plain Cement Concrete well mixed and laid in position using 20% max permissible limit of plums above 160 mm and up to 450mm, including curing and finishing etc including all leads of all construction materials complete in all respect with well graded crusher broken stone aggregate. The plums shall be distributed evenly and shall be not closer than 150 mm from the surface. PCC Nominal Mix 1:3:6 with Plum Max size of Aggregate 40 mm
Add extra over item No. 1 c , 1d, 2 and 3 for centering and shutterring for each additional 1 m height or part thereof above initial height of 3.0m from base/floor level.
Supply and fixing 6 mm thick PVC water seal of approved quality in construction/contraction joint as per drawing complete in all respect. 305 mm wide
Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Beyond 1.5m height
Painting of lifting beam/lifting tackles are per IS 14177, for which surface preparation by blast cleaning, as per class C or class B , primer coat (two coats) of zinc Phosphate primer, to provide dry film thickness of 40 microns per coat and finish coat (two coats) of alkyd based micaceous iron oxide paint, using airless spray, to provide minimum dry film thickness of 65 plus minus 5 microns per coat, at an interval of 24 hours. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 200 microns. This will include expenses on mobilisation and demobilisation of equipments. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.
Painting of lifting beam/lifting tackles are per IS 14177, for which surface preparation by blast cleaning, as per class C or class B , primer coat (two coats) of zinc Phosphate primer, to provide dry film thickness of 40 microns per coat and finish coat (two coats) of alkyd based micaceous iron oxide paint, using airless spray, to provide minimum dry film thickness of 65 5 microns per coat, at an interval of 24 hours. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 200 microns. This will include expenses on mobilisation and demobilisation of equipments. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.beyond 1.5m height
Oiling, Greasing work of gate parts like Headstock, Headstock parts, Roller Assembly, Operating Rod, Sealing Frame, Guide Tee with all Labor tools and tackles etc. and Material for vertical lift sliding type/ fix wheel gates excluding cardium compund and gear oil For gate size above 1 Sqm to 10 Sqm
Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn and neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3
Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn and neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm Labour Charges only
Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing and forwarding charges for all components etc. complete.Rubber seal Flat type 150mm x20mm uncladed
Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete.
Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete
Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Up to 1.5m height
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 40 cusec, 5 mm +-1mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 60 cusec, 6 mm +-1mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded Parshall Flume, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.20 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, assemble dissemble system for easy in handling / transportation including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Channel discharge in Cusec Up to 150 cusec, 7 mm +-1mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 1 cusec, 3 mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 2 cusec, 3 mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 3 cusec, 3 mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 4 cusec, 3 mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 10 cusec, 4 mm thick
Supply and fixing at site (except civil work required) for accurate measurement of flowing water through channels of calibrated pre-fabricated fibre-glass reinforced plastic (FRP) moulded cut throat flume without any joint, with a side chamber provided in U/S connecting through pipe at bottom with water flowing flume accurate in dimensions and having accuracy of + 1 mm smooth and uniform surface with 0.013 as value of rougosity, inside blue outside gray colour, with engraved gauge marking in cm and litre per second and engraved discharge table showing calculation discharge variation at every 0.10 cm and flow measured at submerged condition etc. complete in all respect. The flumes shall consist from M.S. pipe frame embaded in moulding, light in weight and easy in handling including stiffeners hold fast, sand treatment on the back side of flume etc. complete. Up to 15 cusec, 5 mm thick
Providing and laying canal lining with mechanically vibrated 300 x 150 x 50 mm PCC blocks made from concrete mix 1:2:4, A20 including all leads and lifts of material, curing, stacking, loading, unloading and transportation of blocks from manufacturing site to lining site. Single tile lining consisting of 12 mm thick cement mortar (1:6) plaster on sub-grade, 12 mm thick sandwich plaster in cement mortar (1:5) over sub grade and 50 mm thick tile lining in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing, all leads of all construction materials, curing charges and machinery charges with mixture vibration etc., complete as per technical specifications.In sides
Filling of construction joints with Bitumen based sealing compound lining in the grove as per IS made by cutter upto the 1/3 depth of concrete lining as per specification provided in IS: 3384-1986 and all leads of all construction materials including cost of sealing compound, complete in all respect.
Providing and laying under drainage below canal lining consisting of porous concrete of mix ratio 1:4 (1 cement: 4 course aggregate) 75 mm diametre, 300 mm long supported by 75 mm thick layer of coarse aggregate 12.5 mm to 40 mm size and 50 mm thick layer of sand.
Note 18.1 Add extra with the permission of Superintending Engineer, 1. Rs 260.00 per cum of concrete if computerised password protected composite weight-batching and mixing plant with suitable green concrete transportation mechanism or transit mixer is used
Distance stone well dressed of required shape and size 60 cm x 23 cm x 7 cm with exposed faces chiesel dressed.
Fixing of Distance stone in 30x30x30 cm pit excavated in all type of strata and back filling with cement concrete (1:4:8) projected 10 cm above ground level well finished and properly cured. (Excluding cost of Distance stone)
Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material
Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets, wedges, lifting rods etc., with all accessories as per relevant IS code including frame and gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing and forwarding, transportation charges for structural steel components and other materials.
Providing and Laying in position of Cement concrete Design mix M-20 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; (For mix design Cement content considered 400 kg/ cum of concrete) 20 mm
Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. In foundation rafts, beams, columns bases stilling basins, buckets, aprons etc. (non suspended horizontally laid mass concrete)
Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using. Tor or ribbed bars (IS :1786-1985)
Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc.
Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove
Dismantling cement concrete lining including disposal of material within 50 m lead, inclusive of de-watering wherever required of thickness 7.50 cm
Dismantling cement concrete lining including disposal of material within 50 m lead, inclusive of de-watering wherever required of thickness10.0 cm
Dismantling cement concrete including disposal of material within 50 m lead, inclusive of de-watering wherever required.
Demolishing of reinforced concrete including stacking of usable material and disposal of unuseable material within 50 m lead inclusive of de-watering wherever required.
Preparation and dressing the sub grade including removal of irregularities up to 7.5 cm in soil, morrum mixed with pebbles, small boulders and kankar and murrum for Bed
Preparation and dressing the sub grade including removal of irregularities up to 7.5 cm in soil, morrum mixed with pebbles, small boulders and kankar and murrum for Side slopes
Preparation of foundation of structure including removal of all loose stones, silt and final washing. By manual labour
Extra charges for water spray by nozzle on sub grade of canal including bed and side slopes before laying plain concrete for lining work.
Providing and laying cast in situ plain cement concrete design mix M-15 grade for lining, using well graded crusher broken aggregate of maximum nominal size 20 mm conforming to IS:383-1970, including proportioning of the ingredients by weigh batching and mixing by mechanical mixer including finishing of concrete lining, cutting of grooves for construction joints, complete as per specification with all leads and lifts of construction material complete for canal bed of thickness. 7.5 cm
Providing and laying cast in situ plain cement concrete design mix M-15 grade for lining, using well graded crusher broken aggregate of maximum nominal size 20 mm conforming to IS-383-1970, including proportioning of the ingredients by weigh batching and mixing by mechanical mixer including finishing of concrete lining, cutting of grooves for construction joints, complete as per specification with all leads and lifts of construction material complete for canal side of thickness. 10 cm
Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 7.8.1 Add extra over item no. 1 to 7 for Masonry work in superstructure
Dismantling old plaster or skirting, racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead, inclusive of de-watering wherever required.
Plaster in cement sand mortar 1:3 including racking of joints, smooth finishing and curing etc. complete including all leads of all construction materials of thickness: 20 mm
Plaster in cement sand mortar 1:3 including racking of joints, smooth finishing and curing etc. complete including all leads of all construction materials of thickness: 12mm
Making grooves as per design in plaster 10 mm to 20 mm wide.
Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 75 mm
Providing and Laying in position of Cement concrete Design mix M-15 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; (For mix design Cement content considered 320 kg/ cum of concrete) 20 mm
Supplying, laying and spreading of LDPE film of 250 micron on bed and sides including jointing etc. complete as per specifications including cost of LDPE film, overlapping, adhesive tape etc. with transportation charges upto work site complete.
Add extra over items of cement plaster/ cement concrete/cc.lining/cc flooring or RCC for providing and mixing Polypropylene fibres as per IS 16481:2022 or latest revision, 6/12 mm long @ 0.25% (125 gram per 50 kg of cement) or in ratio of as specified by manufacturer specification and direction of Engineer in charge with all leads and lifts.
SARAN BUILDWELL PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.31 MB
Tendernotice_2.pdf
PDF • 6.00 MB
Biddocumentudaisagar.pdf
Tender Documents • 5.99 MB
UdaisagarDrawings.pdf
Other Document • 34.53 MB
BOQ_655373.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid