| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC 183 AMBEDKAR NAGAR BLOCK NO 330 JUHI LAL COLONY KANPUR 208014 | KANPUR NAGAR | UTTAR PRADESH | 208014 | ₹32.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹33.7 L+₹83,241 (2.53%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹33.7 L+₹83,241 (2.53%) | L2 | Rejected-Finance L2 |
| 3 | L3₹34.2 L+₹1.3 L (4.07%)Rejected-Finance | ₹34.2 L+₹1.3 L (4.07%) | L3 | Rejected-Finance L3 |
| 4 | L4₹36.4 L+₹3.5 L (10.6%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | ₹36.4 L+₹3.5 L (10.6%) | L4 | Rejected-Finance L4 |
| 5 | L5₹37.7 L+₹4.8 L (14.5%)Rejected-Finance H NO 1 BISHNU RABHA PATH OPP ZOO POINT BUS STOP R G BARUAH ROAD GUWAHATI 05 ASSAM | ₹37.7 L+₹4.8 L (14.5%) | L5 | Rejected-Finance L5 |
Tender Value
₹38.7 L
Closing Date
9 Feb 2021, 6:00 pmClosed
AGM(E-E), RHQ, NER,GHY
AGM(E-E), RHQ, NER,GHY-15
Provision of Hi wall and cassette type Split A/C,MCBDB, Cable etc.
2021_AAI_68253_1
AAI/RHQ-NER/AGM (E-E)/GHY/NIT-4
Open Tender
Electrical Works
Item Rate
90 days
AGM(E-E), RHQ, NER, GHY
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Exempted
12 Mar 2021
29 Jan 2021
11 Feb 2021
30 Jan 2021
9 Feb 2021
30 Jan 2021
30 Jan 2021 - 2 Feb 2021
Amount
SH-I : ASTI (A/C)
Supply of 5 Star ( inverter type) rated Split Type Air-conditoners 1.45-1.5 TR/17000-18000 BTU fitted with heremetically sealed compressor operating on Refrigerant R-32/R-410A (Green Gas)/Non CFC suitable for wall mounting as per manufacturer recommendation, suitable for operation on 230V, 50Hz Single phase AC supply capable of performing following functions complete as required at site:- a) Cooling. b) Dehumidifying. c) Air Circulating. d) Filtering. e) Remote Controlling including providing standard length of refrigerent Pipe, Drainage pipe and wires.
Supply of 5 Star (inverter type) rated Split Type Air-conditoners 1.8-2TR/22000-24000 BTU fitted with heremetically sealed compressor operating on Refrigerant R-32/R-410A (Green Gas)/Non CFC suitable for wall mounting as per manufacturer recommendation, suitable for operation on 230V, 50Hz Single phase AC supply capable of performing following functions complete as required at site as per AAI approved make:- a) Cooling. b) Dehumidifying. c) Air Circulating. d) Filtering.e) Remote Controlling including providing standard length of refrigerent Pipe, Drainage pipe and wires.
Supply of 3 Star (invertor type) rated Cassette Type Air-conditoners 1.45-1.5TR/17000-18000 BTU fitted with heremetically sealed compressor operating on Refrigerant R-32/R-410A (Green Gas)/Non CFC suitable for ceiling mounting as per manufacturer recommendation, suitable for operation on 230V, 50Hz Single phase AC supply capable of performing following functions complete as required at site:- a) Cooling. b) Dehumidifying. c) Air Circulating. d) Filtering.e) Remote Controlling including providing standard length of refrigerent Pipe, Drainage pipe and wires.
Supply of 3 Star (invertor type) rated Cassette Type Air-conditoners 1.8-2TR/22000-24000 BTU fitted with heremetically sealed compressor operating on Refrigerant R-32/R-410A (Green Gas)/Non CFC suitable for ceiling mounting as per manufacturer recommendation, suitable for operation on 230V, 50Hz Single phase AC supply capable of performing following functions complete as required at site:- a) Cooling. b) Dehumidifying. c) Air Circulating. d) Filtering.e) Remote Controlling including providing standard length of refrigerent Pipe, Drainage pipe and wires.
Installation, testing and commissioning of different capacity split type AC's units i/c fitting of indoor and outdoor unit, pipe, wires, L-clamp etc. at their approved locations, drilling holes with power tool in the wall and providing 80 mm dia PVC pipe sleeve acrod wall for routing pipe & wires, 19mm thick weather proof plyboard of suitable size dully laminated with minimum 0.8 mm thick laminates of approved shade/colour for fixing the indoor unit with suitable fixing hardwares, ceiling supporting arrangement, leak testing of entire system, charging refrigerant gas in the unit, making good the surface as per requirement of the site and to the satisfaction of AAI.
Installation, testing and commissioning of different capacities of Cassette type AC's units i/c fitting of indoor and outdoor unit, pipes, wires etc. at their approved locations, drilling holes in the wall using suitable power tools providing fixing hardwares, ceiling supporting arrangement, leak testing of entire system, charging refrigerant gas in the unit, making good the ceiling surface to the original shape and deisgn as per requirement of the site and to the satisfaction of AAI.
Supply and fixing of 25mm dia PVC drain pipe from the respective units, clamping on different surface like wall/floor etc. i/c sealing the joints with making of openings as per site condition.
Supply and fixing of duly approved colour painted M.S. angle iron frame and mounting of outdoor A.C. units of different capacity on stand complete as reqd. a) Out door unit stand
Supply & fixing of suitable size Copper Refrigerant piping (Supply and return) with expanded polythene foam insulation tubing covering for different rating and type of A/c units. (Measurement of 1 R.Mtr. Will include both supply & return Cu. Piping with insulation).
Supply & fixing of 4Cx2.5sqmm flexible copper wire for control wiring between indoor to outdoor unit for 2.0 TR & 1.5 TR spilt/casette type unit etc as required.
SITC of water cooler cum purifier made of Food grade stainless steel having two taps confirming to IS:1475 (part-1)/(with upto date amendments)suitable for operation on 180-260 VAC 1-phase supply having features/functions like, 2 cold water and 1 normal water faucets; minimum water flow rate 1.5 LPM; minmum 3 stage purification of SF+ ACF+ UV; purifier fault indication; control LED; SS 304 body and tank materials and having refrigerent R134-a or bettter with Capacity as mentioned below:- a)120 Ltr Storage/60 Lts cooling
SITC of table top/floor mounted online hot and cold water purifier with external prefilter and internal SF+RO+UV filtration of 08-11 lts header tank capacity, 0.6-4.0 ltrs hot tank, 1.5-3.0 Ltrs cold tank, 15lts /hr water flow rate suitable for operation on 230 VAC, 50HZ and using on Municipal Water/Corporation Water/Bore Well Water/Tube Well Water etc.
SH-I : AAI MESS INSTITUTE
Supply of 5 Star ( inverter type) rated Split Type Air-conditoners 1.45-1.5 TR/17000-18000 BTU fitted with heremetically sealed compressor operating on Refrigerant R-32/R-410A (Green Gas)/Non CFC suitable for wall mounting as per manufacturer recommendation, suitable for operation on 230V, 50Hz Single phase AC supply capable of performing following functions complete as required at site:- a) Cooling. b) Dehumidifying. c) Air Circulating. d) Filtering. e) Remote Controlling including providing standard length of refrigerent Pipe, Drainage pipe and wires.
Supply of 5 Star (inverter type) rated Split Type Air-conditoners 1.8-2TR/22000-24000 BTU fitted with heremetically sealed compressor operating on Refrigerant R-32/R-410A (Green Gas)/Non CFC suitable for wall mounting as per manufacturer recommendation, suitable for operation on 230V, 50Hz Single phase AC supply capable of performing following functions complete as required at site as per AAI approved make:- a) Cooling. b) Dehumidifying. c) Air Circulating. d) Filtering.e) Remote Controlling including providing standard length of refrigerent Pipe, Drainage pipe and wires.
Installation, testing and commissioning of different capacity split type AC's units i/c fitting of indoor and outdoor unit, pipe, wires, L-clamp etc. at their approved locations, drilling holes with power tool in the wall and providing 80 mm dia PVC pipe sleeve acrodd wall for routing pipe & wires, 19mm thick weather proof plyboard of suitable size dully laminated with minimum 0.8 mm thick laminates of approved shade/colour for fixing the indoor unit with suitable fixing hardwares, ceiling supporting arrangement, leak testing of entire system, charging refrigerant gas in the unit, making good the surface as per requirement of the site and to the satisfaction of AAI.
Supply and fixing of 25mm dia PVC drain pipe from the respective units, clamping on different surface like wall/floor etc. i/c sealing the joints with making of openings as per site condition.
Supply and fixing of duly approved colour painted M.S. angle iron frame and mounting of outdoor A.C. units of different capacity on stand complete as reqd. a) Out door unit stand
Supply & fixing of suitable size Copper Refrigerant piping (Supply and return) with expanded polythene foam insulation tubing covering for different rating and type of A/c units. (Measurement of 1 R.Mtr. Will include both supply & return Cu. Piping with insulation).
Supply & fixing of 4Cx2.5sqmm flexible copper wire for control wiring between indoor to outdoor unit for 2.0 TR & 1.5 TR spilt/casette type unit etc as required.
SITC of water cooler cum purifier made of Food grade stainless steel having two taps confirming to IS:1475 (part-1)/(with upto date amendments)suitable for operation on 180-260 VAC 1-phase supply having features/functions like, 2 cold water and 1 normal water faucets; minimum water flow rate 1.5 LPM; minmum 3 stage purification of SF+ ACF+ UV; purifier fault indication; control LED; SS 304 body and tank materials and having refrigerent R134-a or bettter with Capacity as mentioned below:- a)120 Ltr Storage/60 Lts cooling
SITC of table top/floor mounted online hot and cold water purifier with external prefilter and internal SF+RO+UV filtration of 08-11 lts header tank capacity, 0.6-4.0 ltrs hot tank, 1.5-3.0 Ltrs cold tank, 15lts /hr water flow rate suitable for operation on 230 VAC, 50HZ and using on Municipal Water/Corporation Water/Bore Well Water/Tube Well Water etc.
SH-II : Power supply
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. A. 3.5C x 120 sqmm ( Service Connection)
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. A. 3.5C x 70 sqmm ( Service Connection)
Supply of following size of 1.1 KV grade, Armoured XLPE insulated PVC sheathed Aluminium conductor cable confirming to IS: 7098 part -I amended upto date. b. 4C x 16 sqmm (periphery Lighting)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a. 50mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. b. 110mm dia
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. a. Upto 35 sq.mm.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. b. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. c. Above 95 sq. mm and upto 185 sq. mm
Laying & fixing of one No XLPE insulated & PVC sheathed Aluminium/Copper Cable of 1.1 KV grade of following sizes on surface/ cable tray etc. as required. a. Upto 35 sqmm
Laying & fixing of one No XLPE insulated & PVC sheathed Aluminium/Copper Cable of 1.1 KV grade of following sizes on surface/ cable tray etc. as required. b. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying & fixing of one No XLPE insulated & PVC sheathed Aluminium/Copper Cable of 1.1 KV grade of following sizes on surface/ cable tray etc. as required. c. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. a. Upto 35 sqmm
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. b. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. c. Above 95 sq. mm and upto 185 sq. mm
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. a. 3.5 x 120 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. b. 3.5 x 70 sqmm
Supplying and making end termination with heavy duty type brass single compression gland and aluminium lugs for following size of XLPE insulated aluminium conductor cable of 1.1 kV grade as required. c. 4 x 16 sqmm
Supplying and fixing of 4 way, 4 pole 250A MCCB panel board i/c cable alley, VAF meter, indication lamp, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. a. 160A 4P, 35kA, Ics=100%Icu MCCB-1 nos (incomer) b. 63A 4P, 35kA, Ics=100%Icu MCCB- 4 nos (outgoing)
Supplying and fixing of VTPN MCCB TPN cable end box ( horizontal type ), suitable for 240 and 415 volts, on surface/ recess, completed as per site required.
SH-III: Miscellenous Works
Supply of 400mm sweep wall fan suitable for operation at 230±10% Volts, 50 Hz.
Supply of 45 W ±5 %, 5400K, energy efficient LED street light / roadway light luminaire suitable for pole mount applications with minimum system efficient lumen output of 110 lm/W, IP 65/66 protected single piece pressure die-cast aluminium alloy housing with corrosion resistance powder coating suitable to operate on 230 V, 50 Hz AC complete as specified in Technical specification complete as required.
Supply and installation of 8 meter octagonal GI Pole of 3 mm thickness, including 1.5 meter single arm bracket of 40 mm dia B -class, civil RCC foundation, foundation nut bolts of appropiate length & size i/c interconnection between MCB to light fitting with 3 x 1.5sqmm single core FRLS copper wire, i/c supply & fixing of B-0.5A 10kA SP MCB with rail & 25A 4 way cable termination block, suitable to operate on 230V,50Hz AC supply etc. complete i/c interconnection, earthing, end termination with lugs/thimble etc. as required.
Supply of 253- 260 ltrs,3 star rated,inverter type, stabilizer free operation Energy efficient Refrigerator, double door,Frost free,MOC-Stainless steel suitable for operation at 230+10% volts, 50 Hz.
SITC of 4/5 star rated 10 ltrs Geyser, 2000 Watts complete with AC power cord, incoming & outgoing pipings with stainless steel 304 grade pipe of chrome finish or better and having visual triped & power ON indication suitable for operation at 230+10% volts, 50 Hz.
Supply and fixing DLP PVC trunking of size 105x50mm on the wall using suitable screws/fastener on the horizontal formation along the refrigerant copper piping of indoor AC unit to Outdoor AC Unit.
VOLKS ENERGIE PVT LTD
M/S Saturn Electricals
jaydeep agency corporation
Ace Alliance (P) Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .