Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.0 LAdmitted-Finance | -44.99% | ₹7.0 L | L1 | Admitted-Finance |
| 2 | L2₹9.4 LAdmitted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | -26.93% | ₹9.4 L | L2 | Admitted-Finance |
| 3 | L3₹9.8 LAdmitted-Finance 21 10 SHOP NO 1 SECTOR 3 MAHABINI DELHI 110085 | NORTH WEST | DELHI | 110085 | -23.76% | ₹9.8 L | L3 | Admitted-Finance |
Tender Value
₹12.8 L
EMD Value
₹25,626
Closing Date
9 Feb 2026, 3:00 pmClosed
EE(E)
North Electrical Division, PWD, Dr. BSA Hospital, Sector -6, Rohini, Delhi - 110085
Maint. Elect. Consumption Charges of Street Lighting on PWD Roads under North Electrical Sub DivisionI. SH Upgradation of Lighting system and other allied electrical work at Vikram Batra Chowk
2026_PWD_286042_1
100/NED/PWD/M-352/2025-26
Open Tender
Electrical Works
30 days
as per nit
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹25,626
Yes
16 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
9 Feb 2026
2 Feb 2026
Supplying of one number PVC insulated and PVC sheathed / XLPE sheathed aluminium Conductor armoured power cable of 1.1 kV grade of following size etc complete as reqd. a) 4 x 16 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Fabrication, Supplying and installation of indoor cubical type wall mounted panel board of suitable size not less than 1000mm x1300mm x300mm (deep) made out of M.S. Sheet 2mm. Thick (14 SWG) duly compartmentalised having 4 strip Al. busbar of 200amp capacity double door with locking arrangement for protection from rain, dust and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminium thimbles, earthing with two nos. earth studs duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as reqd. [Note: All MCCB should have Ics=100% Icu] Note: Before fabrication Drawing should be got approved by the Engineer-in-Charge of this work. The panel should have 02 Nos central lock on front door. Areas shall be calculated length & breathe of front of panel only.
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 125 A, 36KA,FPMCCB
b) 63 A, 16 kA,TPMCCB
Fabricating, supplying and fixing of wire mesh protection frame work fabricating with 40 x 40 x 6 mm thick angle iron/Tee iron having intermediate members of size 25mm x 6 mm (GI wire should be 6SWG) flat strip welded at 30 cm in each sections & duly welded with hard drawn wire fabric mesh of size 25 mm X 75 mm having weight not less than 7.5 Kg/Sqmtr. and making main door gate provided with two nos. sliding bolt with godown locks with operating hadle welded from inside of the door i/c providing and fixing of four no. legs of same angle size of 90 cm length duly grouted in foundation (30 x 30 x 45) cm (deep) in 1:2:3 cement concrete & painting with one coat of red oxide & two coat of super synthetic luminous paint of approved colour and quality etc. complete as complete as reqd. {Area of hard drawn wire fabric with angle (Except legs) shall be measured for payment}
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 200 watt
b) 250 watt
Assorted size LED Fittings 150/180/200/ 250 watt
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
BOQ_378624.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid