Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC D 154 ADARSH NAGAR NARMADA ROAD JABALPUR 482001 M P | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹23.1 L+₹90,034.50 (4.06%)Rejected-Finance PLOT NO 12 SAKAR GRAH NIRMAN SOCIETY TILHARI MANDLA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹23.6 L+₹1.4 L (6.45%)Rejected-Finance 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹24.5 L+₹2.3 L (10.3%)Rejected-Finance 114 BARH CHONDI BARH PATNA BIHAR 803213 | PATNA | PATNA | BIHAR | 803213 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹25.0 L+₹2.8 L (12.7%)Rejected-Finance NO 403 BENGALI COLONY RANJHI JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
7 Sept 2024, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
PROVN OF 01 X TRG SHED WITH ELECTRIFICATION AT FIRING RANGE FOR AGNIVEER IN 1 STC UNDER GE (WEST) JABALPUR
2024_MES_663210_1
81055/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
₹58,000
Yes
10 Oct 2024
1 Jul 2024
9 Sept 2024
1 Jul 2024
7 Sept 2024
15 Jul 2024
1 Jul 2024 - 13 Jul 2024
Amount
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete (1:4:8) Type D-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete complete all as specified and as directed.
M&L for RCC -M-25 ( Design mix) using 20mm graded stone aggregate as in foundation including raft footings, foundation beams, plinth beams, bases of columns and the like complete all as specified and as directed.
M&L for RCC -M-25 ( Design mix) using 20mm graded stone aggregate as in Columns, pillars, piers,posts and struts complete all as specified and as directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar works; vertical or to batter, rough finished surface of concrete, complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions, fair finished surface of concrete, complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia as in stirrups, spacers and binders for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed.
M & L rendering 15mm thick on brick wall or concrete surface consisting two layers, under layer of 10mm thick in CM (1:6) & top layer of 5mm thick in cement mortar (1:4) mixed with liquid water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid separately as " Supply only".)
Supply only liquid water proofing compound ISI Marked, of make as approved by GE complete all as specified & directed.
M&L for prepration of new plastered surfaces of walls and applying two coats of cement base paint over & including a coat of cement base primer complete all as specified & directed.
M&L for preparing new plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L Moorum / red bajari filling in floor or pavings, laid in layers n. exc 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed.
M&L for Hardcore of guage n exc 63mm of broken stone aggregate, deposited,spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M & L Damp proof course 40 mm thick in PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate, to horizontal or vertical surface complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150) plain steel sheet of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length & girth as fixed) fixed with self tapping screws complete all as specified & directed.
S&F of pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150) plain steel sheet of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length & girth as fixed) fixed with self tapping screws complete all as specified & directed.
Supply and fix rolled mild steel sections conforming to Fe- 410-W (Gde E-250) quality-A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates etc complete all as specified & directed.
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe- 290 (Gde E-165) complete all as specified and directed.
M&L for 20 to 25 mm dia mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 30 cm long complete all as specified & directed.
M&L for mild steel work conforming to Fe-290 Gde E-165 as in hand rail, holdfast, half round or other steel section or core for wooden hand rail strait portion, drilled and countersunk for balusters running bars for doors, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
M&L for preparation of new surfaces of iron/ steel of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer as approved by GE complete all as specified & directed.
M&L for preparation of new surfaces of iron/ steel of any description n exc 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer as approved by GE complete all as specified & directed.
M&L for machine cut kota stone slab as in flooring, 20-25mm thick laid over & including 15mm thick cement screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L for machine cut kota stone slab as in skirting/ vertical surface, 15-18mm thick laid over & including 10mm thick rendering in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L for 25 mm thick cement concrete (1:2:4) Type B-1, using 20mm graded crushed stone aggregate as in base course complete all as specified and as directed.
M&L for 100 mm thick cement concrete (1:4:8) Type D-2, using 40mm graded crushed stone aggregate as in sub-base complete all as specified and as directed.
S&F framed work as in iron enclosure, doors or gate of angle iron or other section with gussets plate, rails, braces etc drilled for fixing of steel seating other covering, door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel handing door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-290 (Gde-E-165) complete all as specified and as directed. Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
One light point/Bell point controlled by one switch 5/6 Amp.
One socket point controlled by one switch on same board 5/6 Amp.
One socket point controlled by one switch on Independent board 5/6 Amp.
Description all as per item No 36 here-in-before but with 1100 volts grade copper stranded conductor cable of size 2.5 Sqmm with 2.5 Sqmm solid copper conductor PVC for 3 pin switch socket outlet 15 Amp on independent board complete all as specified and directed.
S & F in repair for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed.
S & F for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed.
S & F for switch socket combination 3 pin 5 and 16 Amps AC 230 volts flush type complete all as specified and directed.
S & F for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed .
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt 110 Lumens/watt with diffuser which ensures uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminium housing, Energy efficient, Flicker free start Inbuilt driver unit, Suitable for wall and ceiling mounting using brackets with and including the luminaire testing on completion as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), complete all as specified and directed .
Supply & fix LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with two coat of aluminium paint over a coat of primer complete all as specified and as directed.
S & F Sheet metal enclosure DBs Tripple Pole and Neutral 4 way with 200 Amps rated bus bar 240 volts single pole and neutral, double door, complete all as specified and directed .
S & F MCB TPN 415 volts 63 Amps, C Series complete all as specified and directed .
S & F Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral, double door complete all as specified and directed.
Supply and fixing MCB single pole and neutral 240 volts 40 Amps, 'B' Series complete all as specified and directed.
Supply and fixing MCB single pole 240 volts upto 40 Amps, 'B' Series complete all as specified and directed.
M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron wire 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 35 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc Complete all as directed.
Supply and fixing Single phase ceiling fan 1200 mm permanent magnet brushless DC(BLDC) Motor, 230 Volt, 50 Hz, single phase, 26-30 Watt rated current 0.16 amp,pf 0.98, 370/360 rpm, air delivery 220m3, rated service value 629m3/min/watt, no of blades three, type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire complete with all as required and directed at site
Supply & fixing ceiling fan regulator electronic ROTARY/Step type 120/ 280 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed
Supply,laying & fixing Double Wall Corrugated (DWC) pipes made of High Density Polyethylene (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. complete all as specified and as directed , outer dia 50 mm and inner dia 38 mm complete all as specified & directed
upadhyay Builders (BID ID -3081929)
TRISHLA CONSTRUCTIONS (BID ID -3082796)
MAA SHARDA CONSTRUCTION (BID ID -3086808)
J.P ENTERPRISES (BID ID -3071006)
B G PANDEY AND BROTHERS (BID ID -3070173)
M/S Modern builders (BID ID -3066796)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .