RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Computer Servers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Specification Form Factor Rack Rack
RequiredTower Size (RU) 1 * Processor Make Intel Intel
RequiredAMD
RequiredSPARC
RequiredIBM Power Max. Number of sockets available on chipset 1 1 - 16 1/12 Max. Number of sockets populated with processor 1 1 - 16 Number of core per Processor 4 * Processor Configuration Intel Xeon E-2124 (4C
Required3.3 GHz
Required8MB cache
Required71W) * Chipset compatible with CPU C246 * Availability of Co- Processor No * If Yes Co-Processor Configuration NA * PCI Slots (Express Gen 3.0) 2 * Type of RAM DDR4 * RAM Size (GB) 32 16 - 16000 RAM upgradable upto (GB) 64 32 - 24000 DIMM Slots (No.) 4 * Type of Hard Disk Drive SATA SAS
RequiredNL SAS
RequiredSSD
RequiredSATA Hard disk drive Capacity (GB) 12000 300 - 12000 Hard disk drive Speed (RPM) 7200 * RAID Controller Cache (MB) 0 * RAID Type 5 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard No * Mouse No * Bays (min. 2 internal or more hot plug) 8 * USB Ports (version 2.0/3.0) 4 * Certifications Compliance support by Windows
RequiredRed Hat or Novell or Oracle Cluster Yes * 2/12 or Linux or AIX S/W DVD ROM (or better) 8x or better * Network Card Supported 1G
Required10G * FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * Redundant Power Supply No * Redundant Fan No * Total No of Ports 2x10G SFP+
Required2x1G * Declare SPEC int_rate_base 2006 ; specfp_rate_2006 for 1
Required2
Required4
Required8 prcessor as applicable NA * Server scalability to be achieved within the box without adding nodes Yes * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 350 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server No * 3/12 shall be checked for all the parameters before conditioning
RequiredAfter completion of the above environmental tests sequence
Requiredwith a recovery period of 1 to 2 hrs
Requiredthe server shall be functional Name address of Lab - * Test Report No. date - * Power Supply 230 V +/-10%
Required50 Hz * On Site OEM Warranty (years) 3 1
Required3
Required5 Or higher * Bold specifications are the golden parameters.