Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC EAST LANE GALI NO 01 ABROL NAGAR PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹7.7 Cr Quoted ₹7.8 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹7.8 Cr+₹2.9 L (0.37%)Rejected-Finance | ₹7.8 Cr+₹2.9 L (0.37%) | L2 | Rejected-Finance Rejected being other than lowest |
| 3 | L3₹8.1 Cr+₹32.4 L (4.14%)Rejected-Finance | ₹8.1 Cr+₹32.4 L (4.14%) | L3 | Rejected-Finance Rejected being other than lowest |
| 4 | L4₹8.4 Cr+₹62.2 L (7.96%)Rejected-Finance 2ND FLOOR 15 BHULLAR AVENUE ADJOINING SBI FATEHGARH CHURIAN ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹8.4 Cr+₹62.2 L (7.96%) | L4 | Rejected-Finance Rejected being other than lowest |
| 5 | L5₹9.2 Cr+₹1.3 Cr (17.2%)Rejected-Finance | ₹9.2 Cr+₹1.3 Cr (17.2%) | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹9.0 Cr
EMD Value
₹7.8 L
Closing Date
24 Sept 2022, 6:00 pmClosed
Chief Engineer Pathankot Zone
HQ Chief Engineer Pathankot Zone
ADDN ALTN INCLUDING REPAIR TO QTRS OF JACOB ENCLAVE CANDETH ENCLAVE BHATTACHARJEE ENCLAVE AND BHASKER ENCLAVE UNDER GE N MAMUN
2022_MES_530688_1
CA NO CEPZ-11/2022-23
Open Tender
Civil Works
Item Rate
455 days
Mamun Pathankot
Class S Category a(i)
7 documents required · 7 mandatory
₹3,000
Yes
GE (N) Mamun
₹7.8 L
Yes
10 Nov 2022
14 Jun 2022
1 Oct 2022
14 Jun 2022
24 Sept 2022
6 Sept 2022
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each work complete all as specified and as directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site of work complete all as specified and as directed by Engr-in-Charge.
Taking down shutters of any description exc 1 Sqm and n exc 2 Sqm each including refixing in same opening after easing and adjusting complete all as specified and as directed by Engr-in-Charge.
Taking down shutters of any description exc 1 Sqm and n exc 2 Sqm each complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work built in cement mortar including all quoins arches pillars etc but excluding ashlar facing dressed stone work & precast concrete article and removing rubbish to ouside the MoD land complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and paving (un reinforced) not exceeding 15 cm, thickness, below or above ground level and removing rubbish to outside the MoD land complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (Unreinforced) of any description and in any position not othewise specifically provided for and removing rubbish to outside the MoD land complete all as specified and as directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality, or description) from metal frame glazed with putty or fixed with beads/ clips complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster on brick walls or stone walls any description etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed by Engr-in-Charge.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 15mm dia all as specified and as directed by Engr-in-Charge.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 20mm dia all as specified and as directed by Engr-in-Charge.
Taking down eaves gutters and rainwater pipes 100 mm dia (any size or pattern) including all fitting, head, shoes, bend, swan-nacks etc., including cleaning or refixing or removal to store complete all as specified and as directed by Engr-in-Charge.
Taking down brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar complete all as specified and as directed by Engr-in-Charge.
Material and labour for factory made Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc complete all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer after preparation of steel surface complete all as specified and as directed by Engr-in-Charge.
Repair to old steel window shutter of area not exceeding 1 sqm each including replacement of hinges, handle and necessary welding to shutter and chowkhat for making window in serviceable condition, including two coats of synthatic enamal paint complete all as specified and as directed by Engr-in-Charge.
Repair to old steel window shutter of area exceeding 1.00 sqm but not exceeding 2 sqm each including replacement of hinges, handle and necessary welding to shutter and chowkhat for making window in serviceable condition, , including two coats of synthatic enamal paint complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of pressed steel frame made out of MS sheet 1.25mm thick of size 125mmx60mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of plain cement concrete grade (1:3:6) type C-0 (using 12.5 mm graded crushed stone aggregate) as in back of chowkhats and including two coats of synthentic enamel paint over one coat of red oxide primer after preparation of steel surface complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of pressed steel frame made out of MS sheet 1.25mm thick of size 105mmx60 mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of plain cement concrete grade (1:3:6) type C-0 (using 12.5 mm graded crushed stone aggregate) as in back of chowkhats and including two coats of synthentic enamel paint over a coat of Red oxide primer after preparation of steel surface complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of pressed steel frame made out of MS sheet 1.25mm thick of size 75mmx50mm for doors/windows/cupboard with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of plain cement concrete grade (1:3:6) type C-0 (using 12.5 mm graded crushed stone aggregate) as in back of chowkhats and including two coats of synthentic enamel paint over a coat of Red oxide primer after preparation of steel surface complete all as specified and as directed by Engr-in-Charge
Supply and fixing of 35mm thick 2nd class Hard wood factory made Plain framed, panelled door shutter with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated and fitted to chowkats including two coats of synthetic enamel paint over a coat of pink primer after preparation of wooden surface complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of 35mm thick 2nd class hard wood Glazed and skeleton door shutters (factory made), open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.20 (a) of SSR Part-I 1991 (Larger size to be provided) including two coats of synthetic enamel paint over a coat of pink primer after preparation of wooden surface complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of Solid PVC door frame of size 50mm x 47 mm made out of 5mm thick wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet and reinforced with MS square tube, supplying and fixing in opening as per specifications and drawing complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded Wood grain printed PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of wood grain printed PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rail with 5mm thick x 15 mm wide PVC sheet & beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90 degree) and jointed together with solvent cement, supplying and fixing in the frame at site as per specification and drawing complete all as specified and as directed by Engr-in-Charge.
Material and labour for 18mm to 20mm thick PVC prelaminated solid board with one side decorative choice laminates and other side balancing white (with weight of sheet not less than 9 kg per sqm) as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples and beads to frame complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair for stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples and beads to frame complete all as specified & directed by Engr-in-Charge.
Material and labour for 3 mm thick sheet glass ordinary quality fixed in glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Material and labour for 3 mm thick Figured glass, pin head type & glazing with oil putty in squares of size not exceeding 0.5 sq.m in each pane complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of size 300mm long Aluminium alloy, anodised, sliding door bolt with haspe and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of size 200mm long aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of size 150 mm long aluminium alloy handles, fabricated type anodised extruded section (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of 300mm long Mild steel stove enameled door spring ordinary rat tail rod pattern spring fixed to pressed steel frame / MS frame / wooden chowkhats and necessary welding work etc (if required), including roller and rolling plate complete all as specified and as directed by Engr-in-Charge
Supply and fixing of 100 mm long hasp and staple, mild steel, wire type stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair curtain rod of 25 mm dia bore size made out of anodised aluminium alloy with fixing brackets fancy type, stops, end bulbs etc. , The drapery rod shall be projecting 150mm outer side from the clear opening of doors/windows including necessary fittings complete all as specified and as directed by Engr-in-Charge.
Material and Labour for Brickwork with Fly Ash Bricks (old size bricks) having crushing strength not less than 75kg/Sqm straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed by Engr-in-Charge
Material and Labour for Brickwork with Fly Ash Bricks (old size bricks) having crushing strength not less than 75kg/Sqm straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed by Engr-in-Charge
Material and labour for Rendering 10mm thick in cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge
Material and labour for Rendering 05 mm thick in cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling finished even and fair without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material and labour for Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) in two layers i.e. first layer 10mm thick and second layer of 5mm thick shall be mixed with liquid water proofing admixture as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge Note : Water proofing compound shall be measured and paid for separately under respctive item.
Material and labour for rendering 10mm thick in cement mortar 1:3 on edging / ceiling of Chajjas, roof projections etc, including taking out peeled off plaster / concrete and making the line in true shape and finishing the surface without using extra cement complete all as specified and as directed by Engr-in-Charge
Material and labour for 75mm thick Plain Cement concrete (1:3:6), type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving and laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen of grade 85/25 and sand in ratio 1:2 by weight including use & waste of necessary form work complete all as specified and as directed by Engr-in-Charge
Material and labour for 25 mm thick PCC (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) in as in sub base of floor complete all as specified and as directed by Engr-in-Charge
Material and labour for 15mm thick screed bed or bedding layers of mortar in Cement motar 1:4 for laying floor finishes complete all as specified and as directed by Engr-in-Charge
Material and labour for joint free non skid ceramic coloured tiles 7 to 8 mm thick and area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the finish including dismantling existing floor tiles of any type & pattern including cement mortar bedding & removing debries/tiles out of the premises etc complete all as specified and as directed by Engr-in-Charge
Material and labour for Non-skid ceramic coloured rectified edges tiles (joint free) of 8mm thick and area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match the finish, including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and as directed by Engr-in-Charge
Material and labour for Non-skid ceramic coloured rectified edges tiles (joint free) of 8mm thick and area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in skirting/dado/riser of steps etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 10mm thick screed bed or bedding layer of cement mortar (1:4), including dismantling existing wall tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and as directed by Engr-in-Charge
Material and labour for glazed ceramic coloured tiles on vertical surface of size 450mmx350mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 10mm thick in CM (1:4) finished rough including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) & removing serviceable tiles from site and rubbish off the premises complete all as specified and as directed by Engr-in-Charge
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brusing neat cement slurry with @ (at the rate of) 3.00 kg per sqm all as specified and as directed by Engr-in-Charge
Material and labour for 15mm thick green Marble work (table rubbed and polished) as in cooking plateform, window cill, steps etc and set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra including making hole for gas pipe & dismantling of existing tiles/stones including removing debris/tiles out off the premises etc complete all as specified and as directed by Engr-in-Charge
Material and labour for Round chamfering, to the edges of marble slabs complete all as specified and as directed by Engr-in-Charge
Material and labour for preparation of Old wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint on wooden surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for two coats of synthetic enamel paint on old steel surfaces of any description, n.exc 10 cm in width or girth, including preparation of surfaces, complete all as specified and as directed by Engr-in-Charge.
Preparation of new plastered surface of external wall and chajjas and making the surface smooth with sand paper and priming the surface with alkali resistance primer paint on external surface and applying two coat of cement base paint over primed surface including curing complete all as specified and as directed by Engr-in-Charge.
Preparing new wall surface including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of acrylic, antifungal emulsion exterior weather proof paint on external surface of wall complete all as specified and as directed by Engr-in-Charge.
Material and labour for Preparation of new plastered surface of wall, applying 01 mm thick wall care putty and making the surface smooth and applying two coats of distemper oil emulsion on new surfaces of walls over a coat of primer complete all as specified and as directed by Engr-in-Charge.
Material and labour for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for Preparation of old surface by complete removal of existing treatment and making the surface smooth including applying 01 mm thick wall care putty and two coats of Oil bound distemper on old surface of wall surface over a coat of primer complete all as specified and as directed by Engr-in-Charge.
Preparation of old Wall surface after complete removal of existing treatment and making the surface smooth and applying two coat of cement base paint over a coat of alkali-resistant priming paint on old surface of walls complete all as specified and as directed by Engr-in-Charge.
Material and labour for two coats of white wash on old surface of a wall including preparation of old plastered wall surface after complete removal of existing treatment complete all as specified and as directed by Engr-in-Charge.
Material and labour for two coats of white wash on old surface of ceiling including preparation of old ceiling plastered surface complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for 15mm bore Galvanised steel water tubing, medium grade with all fittings (ISI Marked), fixed complete concealed to walls, ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. (Note : Cutting chases for concealed piping shall be measured and paid for separately under respective items).
Refixing of 15mm bore old steel water tubing medium grade galvanized (ISI marked) with all fittings short pieces such as and fixed complete concealed in walls, floor etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for Cutting chases in Brick walls, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for 20mm bore GI steel water tubing surface/ concealed, medium grade galvanized with all fittings (ISI Marked) (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor complete all as specified and as directed by Engr-in-Charge. (NOTE:- Cutting chases for concealed piping shall be measured and paid separately under respective items).
Refixing of 20mm bore old steel water tubing medium grade galvanized (ISI marked) with all fittings such as short pieces and fixed complete to walls, floor etc all as specified and as directed by Engr-in-Charge.
Supply and fixing for Stop valve/ Angle valve cast copper alloy (ISI Marked) chromium plated Fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of size 15mm bore dia as fixed in reapirs complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Stop valve concealed cast copper alloy (ISI Marked) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with capstan head screwed both ends for iron pipe of size 15mm bore dia as fixed in repair complete all as specifed and as directed by Engr-in-Charge
Supply and fixing Bib tap for 15 mm bore dia pipe, cast copper alloy screwed down crutch butterfly handle with brass furrele as fixed in repairs complete all as specifed and as directed by Engr-in-Charge
Supply and fixing for Vitreous china wash hand basin, white flat back of size 550mm x 400 mm including waste pipe, brackets and cutting for and pinning in ends of brackets or errecting stand fixed including 32 mm dia bore PVC waste pipe of minimum size 600 mm long and waste coupling (PTMT) of 32mm dia bore (min weight 32mm-45gms) size full thread as in Repair complete all as specifed and as directed by Engr-in-Charge
Supply and fixing for 15mm dia bore pillar cock fancy type, chromium plated (ISI Marked) screwed down high pressure with or without letters hot or cold with long screwed shank and fly nuts screwed for iron pipe as fixed in repairs complete all as specifed and as directed by Engr-in-Charge.
Supply and fixing as in repair Brass chromium Tubular Towel rail ,20mm dia 'D' type plated of size 600 mm long between flanges fixed wih chromium plated screw & PVC cleats complete all as specifed and as directed by Engr-in-Charge
Supply and fixing as in repair Brass Chromium Plated Shower rose with or without swivel joints, 125mm long including fixing to steel pipe or union complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Vitreous China squatting pan of orissa pattern, of size 580mmx440mm white with Intergral foot rest & CI ‘P’ or ‘S’ trap, front or back inlet any pattern (including fixing of flush pipe) and making connection to trap and to flushing pipe antisyphonic pipe including demolition of existing pan and as fixed in repair complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain Cement Concrete (1:5:10) type E2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete (sunken floors etc.) complete all as specified and as directed by Engr-in-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 using liquid water proofing compound to sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement including application of 90 micron polythene film and applying bitumen coating @ 3.00 Kg/Sqm all as specified and as directed by Engr-in-Charge. Note : Water proofing compound shall be measured and paid for separately under respctive item.
Supply and fixing as in repair PVC flushing cistern of 10 litres capacity including PVC connection and integrated Ball Valve, inlet and outlet connections, brackets, PVC flush pipe with bend of size 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for PVC connections for pipe of 15mm bore dia size with PTMT nuts of length 450mm as in repair complete all as specified and as directed by Engr-in-Charge.
Supplying and fixing for Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing RCC/ PVC tank of any capacity complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed cast copper alloy, chromium plated, fancy type (ISI marked) with crutch or butter fly handles screwed down screwed for iron pipe of size 20mm dia bore complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for PVC (SWR) pipes of size 110mm bore, single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 75mm bore, single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for PVC (SWR) bend any radius for 110mm dia bore pipe complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 110mm PVC (SWR) bends any radius complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 75mm PVC (SWR) bends any radius complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair PVC (SWR) pipes of size 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 110mm PVC (SWR) reducers complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 75mm dia PVC (SWR) vent cowl complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, provided with oval access door (ISI Marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 75mm dia PVC (SWR) branch piece, double (double Y) equal or unequal, provided with oval access door (ISI Marked) complete all as specified and as directed by Engr-in-Charge.
Material and labour as in repair PVC(SWR) floor trap 75 mm dia with grating including jointing with solvent cement complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for stainless steel sink with drainage board made of stainless steel sheet of 1mm thick for kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe with overall size 915mmx460mm and bowl size 410mm x 330mm x 160mm including 32 mm dia bore PVC waste outlet pipe of minimum length 600mm complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for stainless steel kitchen plate rack of size 750mm x 900 mm of approved make fixed with mild steel screw and PVC cleats on wall surface complete all as specified and as directed by Engr-in-Charge.
Material and labour for mild steel TMT bars (Fe-500D) 10mm dia & over cut to length bend to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain Cement Concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in levelling course/padding using water proofing compound laid over existing roof, surface finished rough to receive cement mortar including necessary use and waste of formwork complete all as specified and as directed by Engr-in-Charge. Note: (WPC shall be measured and paid separately under respective items of BOQ )
Material and labour for plain cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) as in seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings up to 60 cm in height, water troughs and the like rounded or chamfered on edges including necessary use and waste of form work all as specified and as directed by Engr-in-Charge.
Material and labour for Rendering 20mm thick in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 litre in 50 Kg of cement complete all as specified and as directed by Engr-in-Charge. (Note:- Water proofing compound shall be measured and paid separately under respective items of BOQ)
Material and labour for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and as directed by Engr-in-Charge:- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under: (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.
Material and labour for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and as directed by Engr-in-Charge:- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Material and labour for 40mm thick brick tiles laid on cement mortar & joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over and including 15mm thick screed bed or bedding layer of cement mortar in CM 1:6 etc complete all as specifed and as directed by Engr-in-Charge.
Material and labour for 40mm thick serviceable brick tile (Except brick tile) as laid on cement mortar & joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over and including 15mm thick screed bed or bedding layer of cement mortar in CM 1:6 etc complete all as specifed and as directed by Engr-in-Charge. (Note:-Servicable brick tiles shall be used as retrived from serial item no-12 here-in-before. Furhter, quoted rates for this item shall include shifting of brick tiles including its lead from one block to another block. No claim whatsoever shall be admissible on this account at the later stage.)
Supply only Polymer liquid water proofing compound of approved make complete all as specified and as directed by Engr-in-Charge.
Material and labour for cleaning, breaking of loose concrete and cleaning of reinforcement and filling the same with plain cement concrete 1:1.5:3, type A0 (using 12.5mm graded crushed stone aggregate) at places as per site requirement complete all as specifed and as directed by Engr-in-Charge (Note:- The cost of scaffolding including use and waste of form work shall deemed to be included in the quoted rate for this item).
Material and labour for Providing and injecting chemical emulsion for post constructional anti-termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litre per linear meter including drilling and plugging of holes with Cement Mortar 1:2 to match the exisiting finish etc as in apron/plinth protection complete all as specified in IS-Code 6313 Part (3) : 2001 and as directed by Engr-in-Charge.
Material and Labour for Providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using chemical emulsion @ one litre per hole at a distance 300 mm apart along the junction of floor and wall, along joints in floors including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floor complete all as specified in IS code-6313 Part (3) : 2001 and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and not exc 10 Sqm on plan in any type of soil or all kind of Soil and getting out, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil or all kind of Soil complete all as specified and as directed by Engr-in-Charge.
Removal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point and disposal outside the premises complete all as specified and as directed by Engr-in-Charge.
Material and labour for plain Cement concrete (1:4:8), Type D2 (Nominal mix) (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concrete complete, all as specified and as directed by Engr-in-Charge.
Material and labour for Plain Cement Concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains complete all as specified and as directed by Engr-in-Charge.
Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain cement Concrete bed for 200mm dia bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, in Plain cement concrete (1:3:6), type C-2 (using 40mm graded crushed stone aggregates) complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain cement Concrete bed for 150mm dia bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, in plain cement concrete (1:3:6), type C-2 (using 40mm graded crushed stone aggregates) complete all as specified and as directed by Engr-in-Charge.
Material and labour for Reinforced cement concrete pipes for size 200mm dia bore of pipe (Class NP-2) confirming to IS-458-2003 as laid in trenches and jointed with collars including testing complete all as specified and as directed by Engr-in-Charge. Note:- (a)The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified. (b) The pipes shall be measured net as fixed between the fittings and specials, if any, without any allowance for cutting and waste. (c) Fittings and specials shall be measured separately. The rates include for all necessary extra joints, waste, and cutting etc. Excavation, earthwork and concrete work shall be measured & paid separately under respective item of BOQ.
Material and labour for Reinforced cement concrete pipes for size 150mm bore dia of pipe (Class NP-2) confirming to IS-458-2003 as laid in trenches and jointed with collars including testing complete all as specified and as directed by Engr-in-Charge. Note:- (a)The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified. (b) The pipes shall be measured net as fixed between the fittings and specials, if any, without any allowance for cutting and waste. (c) Fittings and specials shall be measured separately. The rates include for all necessary extra joints, waste, and cutting etc. Excavation, earthwork and concrete work shall be measured & paid separately under respective item of BOQ.
Material and labour for cuting into existing manholes for 150mm dia pipe for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) smooth finished and reforming beching as required complete all as specified and as directed by Engr-in-Charge
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil or all kind of soil complete all as specified and as directed by Engr-in-Charge
Material and labour for 75 mm thickness Plain cement concrete (1:4:8) (type D-2) (Using 40mm graded crushed stone aggregates) as in sub base for Flooring complete all as specified and complete all as specified and as directed by Engr-in-Charge
Material and labour for 60mm thick factory made machine pressed Precast Cement concrete (Rubberised coloured, Laminated) interlocking Paver block (using Vibro compaction method) (Topping thickness not less than 5mm) with Grey cement & pigment (non fadable glossy Pigment) of approved shade of any shape and size conforming to IS-15658-2006 of M-35 Grade laid over 25mm thick sand cushion under floor including watering and Consolidering complete all as specified and as directed by Engineer-in-Charge. Note:- Sand cusion shall be measured & paid separatally.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed by Engr-in-Charge
Material and labour for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable of size 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor as earth wire drawn through and including concealed PVC conduit (ISI Marked) of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box including sheet steel/GI terminal box of adequate size having thickness not less than 2.0mm thick including 3mm thick bakelite sheet cover for mounting of switch/socket etc connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible) (With proper colour code will be used for wiring as per the electrical rule), For one light point controlled by one way 5 Amp switch, 240 volts SP complete all as specified and as directed by Engr-in-Charge (Note : Switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
Description complete all as per Serial item No 124 here-in-before, but for one ceiling/Exhaust fan point controlled by one switch, Single pole, one way, 5 Amp, 240 Volts complete all as specified and as directed by Engr-in-Charge (Note : Switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
Description complete all as per Serial item No 124 here-in-before, but for One light point controlled by two 2-way switches, 240 Volts complete all as specified and as directed by Engr-in-Charge (Note : Switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
Description complete all as per Serial item No 124 here-in-before, but for One bell buzzer point controlled by one bell push, 5 Amps, 240 Volts, Single pole complete all as specified and as directed by Engr-in-Charge (Note : Switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
Description complete all as per Serial item No 124 here-in-before, but for one 5 pin, 5 Amps socket outlet point on same board controlled by one switch, Single pole, 5 Amps, 240 Volts complete all as specified and as directed by Engr-in-Charge (Note : Switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
Description complete all as per Serial item No 124 here-in-before, but for one 5 pin, 5 Amps socket outlet point on Independent board controlled by one switch, Single pole, One way, 5 Amps, 240 Volts complete all as specified and as directed by Engr-in-Charge (Note : Switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
Material and labour for point wiring using FRLS PVC insulated unsheathed/multi stranded copper conductor cable 2.5 sqmm including 2.5 sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20mm dia and 1.8 mm thick including all fittings viz tees, bends, juction box including sheet steel/GI terminal box of adequate size having thickness not less than 2.0mm thick including 3mm thick bakelite sheet cover for mounting of switch/socket etc for one 5 pin socket outlet 15 amps, Multi purpose independent point controlled by 15 Amp switch Single pole, one way, 240 volts connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles of pin/u type etc (conduit shall be fixed on surface of ceilng with necessary saddles where concealing of conduit is not feasible), complete all as specified and as directed by Engr-in-Charge .(Note : Switch/Socket etc shall be measured and paid separately under respective items.)
Material and labour for Submain wiring with 2 run of single core, 2x6 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 volts FRLS (using colour code as per IS) with and including 1 x 6 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable (using colour code as per IS) connected to common earth point and connected to earth dolly drawn through and Including concealed PVC rigid conduit of 25mm bore dia size, heavy grade (ISI marked) having thickness not less than 1.8mm with and including all accessories, complete including taking down old submain wiring (any type any size) complete all as specified and as directed by Engr-in-Charge. Note : Two runs of single core cable with one run of earth cable and conduit shall be measured as one RM.
Supply and fixing for Switch piano flush button single pole, one way, 5 Amp AC 240 volts (ISI marked) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Socket outlet 2 in 1,3 pin Flush type, 5 Amp AC 240 Volts (ISI Marked ) complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Socket outlet 2 in 1, 3 pin, 5 and 15 Amp, flush type AC 240 Volts complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Switch piano flush button single pole one way, 15 Amp, AC 240 volts complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Switch bell push flush type 5 Amp AC, 240 volts complete all as specified and as directed by Engr-in-Charge
Supply and fixing for Ding dong door bell electric suitable for AC 230 Volt, single pole complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Switch piano flush button single pole, two way, 5 Amp AC, 240 volts complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Ceiling rose polycarbonate isolated body surface bakelite not less than 65mmx50mm dia three terminals AC, 240 volts complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Ceiling fan regulator electronic type or BLDC type 5 stage (step type) speed variation not less than 100 W, socket type in size, suitable for 1200/1400mm sweep Ceiling fan hum free including necessary connections complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including 15 Watt LED lamp of approved make and Cat part No and PVC round/square block etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for SPN MCB DB 8 way, sheet metal enclosures double door 230 Volts AC, 50 Hz AC with 200 Amp rated copper bus bar and polyurethrene gasket including taking down old unserviceable DB complete as specified and as directed by Engr-in-Charge.
Supplying and fixing for MCB SPN 240 Volt, 50 Hz, 10 KA, 'B' curve of rating 32 Amp complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for MCB SP 240 Volt, 50 Hz, 10 KA, 'B' curve of rating 6 Amp to 32 Amp complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing of LED light fitting 10 Watt (IP-66 Protection) bulk head, energy efficient, wall mounted pressure die cast aluminium housing and enclosed with polycarbonate cover with all accessories and clear prismatic diffuser CCT 5700K+/-300K complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of 0.50 Sqmm size of 230 V, 50 Hz complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED building / street light fitting of capacity 1x30 watts, 230 volt, energy saving and environmental friendly long life versatile pressure die cast aluminium (IP- 65 Protection), IK-07 rating road way luminary high power LED street light with electronic driver including heat resistance toughened glass with lens as light source complete mounted on wall/pole with and including GI bracket made out of suitable dia as per light fitting bore and 0.8 mtr long light grade GI Pipe bent to shape mounted on wall with the help of 02 Nos suitable size of FI holding clamp with nuts, bolts and washers and making electrical connection with 1.5 Sqmm three single core PVC insulated unsheathed copper conductor cable multistranded cable from ceiling rose to light fittings, with all accessories internally pre wired complete all as specified and as directed by Engr-in-Charge. NOTE:- 1. LM-79 and LM-80 test report from NABL lab shall be povided. 2. CRI (Coulour Rendring Index) of fixture shall be > 80. 3. CCT (Colour Corelated temprature) of fixture shall be 5700+/-300K. 4. System Lumen Efficacy shall be > 120Lm/W. 5. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor. 6. CA No shall be written on each fitting before installation. 7. The name of manufacturer to be embossed on the fitting. 8. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
Supply and Fixing for mirror light fitting 1x7 or 10 watt 2 feet LED type with all accessories including inbuilt lamp connecting electrically to ceiling rose using cord flexible 3core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm as in repair complete all as specified and as directed by Engr-in-Charge. Notes :- 1. CCT (Colour Corelated temprature) of fixture shall be 5700+/-300K. 2. System Lumen Efficacy shall be > 100Lm/W 3. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 4. CA No shall be written on each fitting before installation.
Supply and fixing of 20W surface/wall mounted batten LED luminair comprises with 20 watt integrated tube rod, extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life, CRI=80 (Minimum), PF>0.95, luminous efficacy>100 lumens/Watt operating voltage 140V-240V, CCT (K) shall be 5700+/-300, THD<10% complete with all accessories innternally prewired and including conecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and as directed by Engr-in-Charge NOTE:- 1. The defect liability period of LED light shall be 02 years from the certified date of completion & the Contractor shall replace/repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 2. CA No shall be written on each fitting before installation. 3. The name of manufacturer to be embossed on the fitting. 4. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
Material and labour for Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to Galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore dia including 40mm thick cover of RCC (1:2:4) Type B-1 (using 20mm graded crushed stone Aggregate) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made of shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil including returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I (specificetion) and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and as directed by Engr-in-Charge
Supply and fixing of distribution board iron clad vertical TPN DB double door made out of CRCA power coated sheets with IP-43 protection and mechanical strength as IK-09 suitable for MCCB as incomer and MCB as outgoing 415V 3 Phase 50Hz 4 way complete with appropriate size of copper bus bar and neutral link complete with one MCCB 3 pole 415 V 63 Amps rating, 16 KA with adjustable thermal and fixed magnetic release of the same make as of distribution board complete all as specified and as directed by Engr-in-Charge. Note: (MCBs will be measured and paid separately under respective items)
Supply and fixing of 5 star rated BLDC ceiling fan 230 volts, single phase of 1200mm sweep double ball bearing type including down rod, canopy cover etc and connecting with 3 core flexible copper conductor of size 0.50 sqmm and including writing of MES No with black enamelled paint complete all as specified and as directed by Engr-in-Charge
Taking down carefully serviceable single phase energy meters from meter box after carefully disconnecting the electrical connections and keeping aside, dismantling old burnt/unservicable meter box including supply and fixing sheet moulded compound (SMC), fire retardant type meter box of size not less than 600mmx500mmx150mm to enclosed 04 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet and proper locking arrangment, flush mounting in wall and refixing the serviceable electric meters and making electrical connections with suitable size of FRLS PVC insulated copper cable (phase+Neutral) including cleaning of disturbed area and making good the disturbed surface and matching with existing specification of surface finishes complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of heavy duty metallic exhaust fan AC single phase 230/240 Volts of size 230mm sweep with louver's including grouting nut bolts and making the suitable hole of suitable size by breaking the existing wall and making good the disturbed surface by plastering and matching with existing specifications with suitable finishes as per site requirement complete all as specified and as directed by Engr-in-Charge
Supply and installing of the electric water storage heater ABS type 25 ltr capacity 5 Star rated of ABS body vertical type glass lined of inner tank and heating element and having the wall mounting arrangement, thermostate, indicators and thermally insulated stainless steel tank of glass lined inside the tank and heating element including stainless steel braided flexible connection with GI hexagonal adopters/nuts on both sides for pipe of size 15mm dia bore and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed by Engr-in-Charge
Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 25 Sqmm 4 core as per IS-7098 Part-I, XLPE insulated Aluminium conductor heavy duty served with an inner sheathing PVC tape galvanized steel strip or wire armoured with an overall PVC sheathing laid under ground, fixed along wall, through GI pipe under floor/Road including dismantling of existing service cable of any size from electric pole to building, complete all as specified and as directed by Engr-in-Charge.
Material and labour for Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable laid and punned down to form a bed to a minimum 18 cm thickness. The punning shall be done by hand complete all as specified and as directed by Engr-in-Charge (NOTE:- Punned thickness of 18cm shall be considered for measurement purpose only)
Material and labour for well burned bricks, laid flat (old size) sub class B designation 75 for cable protection complete all as specified and as directed by Engr-in-Charge
Material and labour for 40mm dia bore size galvanized steel water tubing pipe (light grade) for protection of cable including suitable size clamps with all fitting and fixed complete to walls and ceilings or laid in floors/fixed to poles/or passing under road crossing, complete all as specified and as directed by Engr-in-Charge
Material and labour for cutting the PCC floor/road/wall not less than 15cm in depth and 15cm in width for inserting GI pipe upto 40mm dia bore for cable protection and making good the disturbed wall/floor/road surface and matching with the existing surface specifications complete all as specified and as directed by Engr-in-Charge (Note: PCC work for road repair work to be measured and paid separately under respective item of BOQ)
Material and labour for Plain cement concrete (1:3:6) type C1 (using 20mm graded crushed stone aggregates) for road repair and levelling with existing surface of road/floor complete all as specified and as directed by Engr-in-Charge
Note: The schedule of credit in Pdf format has been attached with tender and amount of credit schedule i.e. Rs 11,90,883.00 shall be deducted from the total quoted amount of BOQ to arrive at the contract sum.
TRIVENI CONSTRUCTIONS
M/S Satpal and co.
JAGSON CONSTRUCTIONS LTD
Faith Builders
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
M/s. Lakhbir constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .