TECHNICAL
12 conditions · 1 needing a document upload
Tenderer must have to submit valid Electrical Contractor license as perIndian Electricity Rules for the respective category of works issued byGovernment Electrical License Board on or before the closing date oftender. Copy of the electrical contractor license should be submittedalong with the tender offer, otherwise, the tender will be summarilyrejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
51 conditions · 5 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Shifting of existing LC gate No. ST-34 SPL at CH:104/736 for 45 m towards CPK end due to construction of ROB. (Electric Portion)
EL-LM-26-27-25~NFR
EL-LM-26-27-25
Open
Works - General
60 Days
Hojai, Assam
₹0
₹4,100
10 Sept 2026
10 Sept 2026
21 Sept 2026
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,02,696.52 | ||
| — | 8.00 | — | — | ||
| Supply, fitting, fixing,connection & commissioning of 18/20 watt, 230V, 50 Hz LED indoor fitting complete set with LED tube and other accessories. The fitting shall be connected by 1.5sq mm flexible copper wire through pvc pipes/casing as required at site. | — | — | — | 2,513.6 | |
| — | 8.00 | — | — | ||
| Supply and wiring of light point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sq single core PVC insulated flexible coppercable and flush type 5/6 amp controlling switch to be providedon hard plastic moulded board.Casing shall be fixed on the wall/ ceiling by MS screw (6x40 mm)at an interval not more than 300 mm | — | — | — | 1,268.64 | |
| — | 3.00 | — | — | ||
| Supply and wiring of ceiling fan point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sqsingle core PVC insulated flexible copper cable withearth continuity by 16SWG bare copper wire andflush type 5/6 amp controlling switch to be provided on hard plastic moulded board including 300W box type stepped electronic fan regulator.Ceiling fan connection shallbe done through ceilingrose. Casing shall be fixedon the wall / ceiling by MS (6x40 mm) screw at an interval not more than300mm | — | — | — | 797.79 | |
| — | 2.00 | — | — | ||
| Supply of materials and wiring of modular type mobile charging through concealed/surface wiring with mobile keeping tray by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealedrigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch 3 no and 6/10 amp 5 pin modular socket 3 nos to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper size (i.e. thickness of mounting boxes of 3 mm and inside width of box should be 50 mm).All other accessories i.e. PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site color of the surface. | — | — | — | 1,470.26 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of ceiling fan 1200 mm with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 6.0 CM/Min/Watt(minomum), air delivery 210 CM/Min (Minimum), 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required | — | — | — | 8,085 | |
| — | 1.00 | — | — | ||
| Manufacturing, supply, erection, testing and commissioning of outdoor type feeder pillar of size 1000 mm (H) x 600 mm (W) x 350 mm (D), complete with RYB LED phase indication lamps, three-phase and neutral aluminium busbars of minimum 200 Amp capacity and minimum size 25 mm x 6 mm, provided with suitable insulation covers/shrouds for each phase and neutral, complete with supply and fixing of MCCBs as specified in the respective schedule, internal wiring and interconnections. The feeder pillar shall be securely grouted on the ground using four numbers mounting angles of size 50 mm x 50 mm x 6 mm and 500 mm length, including all necessary civil works, foundation/grouting materials and fixing hardware. The scope shall also include complete end cable termination using properly sized cable lugs, cable glands and all other necessary accessories, labour, tools and tackles required for satisfactory completion and commissioning of the work, as per the direction of the Engineer-in-Charge/Site Engineer. | — | — | — | 16,551.29 | |
| — | 1.00 | — | — | ||
| Supply, fitting, fixing, installation, testing and commissioning of 63 Amp, 4-Pole MCCB, having 25 kA short-circuit breaking capacity with Ics = 100% of Icu, adjustable thermal- magnetic trip unit with thermal adjustment from 0.8 to 1.0 In and magnetic setting fixed at 10 In, complete with adjustable earth-leakage sensitivity of 0.03/0.3/1/3 A and adjustable tripping time of 0/0.3/1/3 seconds, confirming to IEC 60947-2, including all necessary accessories, connections, hardware, labour, testing and commissioning as required for complete and satisfactory operation. | — | — | — | 13,130 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 40 Amp, 4-Pole, C-Curve MCB, complete with suitable terminals, connections, mounting accessories, hardware and all necessary materials, confirming to relevant IS/IEC standards, as required for complete and satisfactory operation. | — | — | — | 3,060 | |
| — | 2.00 | — | — | ||
| Dismantling, shifting, carrying and erection of 9.0 metre height swaged type GI Octagonal Pole including supply and fixing of the pole complete with necessary nuts, bolts and accessories, with Cement Concrete foundation in the ratio 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate of nominal size 20 mm), including earth excavation, proper alignment and plumbing of the pole, ramming, curing of concrete, muffing above ground level and restoration of the site, complete in all respects as directed by the Engineer-in-charge. | — | — | — | 7,000 | |
| — | 4.00 | — | — | ||
| Dismantling/Uprooting of existing Rail/Tubular Pole with all accessories without damage from the work site and handing over to SSE incharge office asper instruction of site Engineer in-charge of the railway. | — | — | — | 3,819.2 | |
| — | 1.00 | — | — | ||
| Shifting, fixing, installation, testing and commissioning of Automatic Changeover- cum-Distribution Panel for CLS, suitable for 60 Amp capacity, 240 Volts, 3-phase, 50 Hz supply for 10 kVA AT, complete in all respects as per latest RDSO Specification No. TI/SPC/PSI/CLS/0020 with A&C Slip No. 1 to 4, conforming to CORE-approved Drawing No. ASCOS/ORE/2025/01 Rev.02 or latest, including all necessary accessories, interconnections, mounting/fixing hardware, testing and commissioning as required for satisfactory operation. | — | — | — | 9,999 | |
| — | 4.00 | — | — | ||
| Supply and erection of earthing by made of B class GI pipe of 4000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with at apered casing at the lowerend in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil.Where soil restivity is high,earth restivity enhancing material may be used,Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg.No. : PCEE/ELG/DRG/2024/1/Rev- 1 dated 28.07.2025 & as per Technical circular no.EL/PS/2025/1 (Pipe Earthing arrangements) | — | — | — | 5,415.24 | |
| — | 4.00 | — | — | ||
| Supply and wiring of 15/16 amp, 5/6 pin plug scoket point through good quality hard PVC casing with associated accessories for surface type wiring by 4 mm sq single core PVC insulatedflexible copper cable with earth continuity by 16 SWG bare copper wire and flush type15/16 amp controlling switch(with glowing indicator type & safety fuse) to be provided on hard plastic moulded board. Casing shallbe fixed on the wall / ceiling by MS (6x40mm) screw at an interval not more than300mm . | — | — | — | 1,195.52 | |
| — | 600.00 | — | — | ||
| Supply, laying and commissioning of 2-core, 16 sq. mm PVC insulated and sheathed aluminium stranded/twisted cable, including stringing of 1 No. 6 SWG GI wire for supporting the cable, with cable securely laced/bound to the GI wire at intervals of approximately 2 metres, from the service pole to the service pipe, complete with all necessary accessories, clamps, binding materials and connections, as per the direction of the Engineer-in-Charge at site. | — | — | — | 36,354 | |
| — | 600.00 | — | — | ||
| Supply, fitting and fixing of 6 SWG GI wire for strengthening/support of the above- mentioned(Item no 14) electrical installation at different locations, complete with all necessary clamps, binding materials, supports and accessories, as required, and as per the instructions and directions of the Engineer-in-Charge at site. | — | — | — | 18,564 | |
| — | 2.00 | — | — | ||
| "Supply, installation, testing & commissioning of 45 watt, 230V, 50 Hz outdoor LED street light luminaire with heat resistantglass with connecting lead (IP protection- IP 66 class- I,System efficacy>=105 lm/w, Housing- Pressure die castaluminium powder coated, THD<10%, p.f.>0.95, Surgeprotection- 5 kV) as per instruction of Engineer inchargeat site. (Embarcking maximum light to ensure visibilityat night to persons with low visibility) | — | — | — | 7,671.66 | |
| — | 2.00 | — | — | ||
| Supply and wiring of exhaust fan point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sq single core PVC insulated flexible copper wire with earth continuity by16 SWG bare copper wire and flush type 5/6amp controlling switch to be provided on hard plastic moulded board . Exhaust fan connection shall be done through ceiling rose. Casing shall be fixed on the wall /ceiling by MS (6x40 mm) screw at an interval not more than 300mm | — | — | — | 549.32 | |
| — | 1.00 | — | — | ||
| Complete shifting, dismantling, transportation, re-erection, installation, testing and commissioning of existing 0.645 kWp solar power plant from the existing location to the new LC Gate location, including careful dismantling of all existing solar modules, mounting structures, solar inverter/controller, cables, junction boxes, earthing connections and other associated equipment, transportation and carriage to the new location, re-fixing/re-erection and alignment of the complete system with reuse of all existing serviceable components and connections. The work shall include all necessary civil and foundation works, including supply of brick, cement, sand, concrete, foundation hardware, clamps, fasteners, cable accessories and other required materials, complete with reconnection of all existing electrical connections, proper earthing, testing and commissioning of the solar plant at the new location, as per site conditions and directions of the Engineer-in-Charge. The item shall be complete in all respects for satisfactory operation of the existing 0.645 kWp solar plant at the new LC Gate location. | — | — | — | 15,000 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing, installation, testing and commissioning of 200 Amp copper busbar chamber, wall-mounted type, comprising 4 Nos. ETP-grade copper busbars of size 20 mm x 5 mm (3-phase and neutral), complete with suitable insulation covers/shrouds, busbar supports, mounting arrangements, terminal connections, hardware and all necessary accessories, ensuring proper phase identification and safe electrical clearances, complete in all respects as per relevant IS/IEC standards and as directed by the Engineer-in-Charge at site. | — | — | — | 33,880 | |
| — | 400.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPEinsulated power cables with armoured aluminum conductors of different sizes partly along the pole andpartly through ground in cable trench.Loading, unloading & carrying of cable toactual work site by contractor own arrangement as per instruction of Engineer incharge at site. | — | — | — | 16,372 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-25_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .