Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹22.1 L+₹53,414.91 (2.48%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹22.2 L+₹70,159.60 (3.26%)Rejected-AOC 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹22.3 L+₹71,126.20 (3.30%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹22.5 L+₹99,479.56 (4.62%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
23 Oct 2023, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO PIN - 913867
REP AND MAINT OF DG SETS, DG SET PANEL, OIL FIRE INCINERATOR MECHANICAL LOUNDRY, LIGHTNING CONDUCTOR, EM EQPT AND ALLIED WORKS AT KALIMPONG AND SHERWANI MIL STN UNDER GE 867 EWS
2023_MES_614741_2
GE/867/TOKEN/47 OF 2023-2024
Open Tender
Civil Works
Item Wise
270 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹42,000
1 Dec 2023
9 Oct 2023
25 Oct 2023
9 Oct 2023
23 Oct 2023
16 Oct 2023
9 Oct 2023 - 13 Oct 2023
Amount
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of 62.5 KVA DG Set complete of following ( i,e. Engine, alternator etc under GE 867 EWS all including consumables items like cotton waste cloth kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chare of maintenance schedule, complete all as specified and as directed. Note- Accessories / spares/ new engine oil required for replacement will be measured and paid separately under respective items of schedule ‘A’ as supply only (i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy. (iii)Changing of water filter. (iv) Making up coolant. (v) Clean alternator winding in position by forced air and internal surfaces lubricate. (vi) Tightining of all nut bolts. (vii) Greasing of all points. (viii) Checking of any leaking in fuel & oil lines
All as per item no. 1.00 but for 50 KVA DG Set
All as per item no. 1.00 but for 40 KVA DG set
All as per item no. 1.00 but for 30 KVA DG set
All as per item no. 1.00 but for 25 KVA DG set
All as per item no. 1.00 but for 10 KVA DG set
Supply only new Engine oil 15 W 20, complete all as specified and as directed. Make : HP/BP/Indian
Supply only fuel filter suitable for 62.5 KVA DG Set, complete all as specified and as directed.
Supply only fuel filter suitable for 50 KVA DG Set, complete all as specified and as directed.
Supply only fuel filter suitable for 40 KVA DG Set, complete all as specified and as directed.
Supply only fuel filter suitable for 30 KVA DG Set, complete all as specified and as directed.
Supply only fuel filter suitable for 25 KVA DG Set, complete all as specified and as directed.
Supply only fuel filter suitable for 10 KVA DG Set, complete all as specified and as directed.
Supply only lubricant oil filter suitable for 62.5 KVA DG Set, complete all as specified and as directed.
Supply only lubricant oil filter suitable for 50 KVA DG Set, complete all as specified and as directed.
Supply only lubricant oil filter suitable for 40 KVA DG Set, complete all as specified and as directed.
Supply only lubricant oil filter suitable for 30 KVA DG Set, complete all as specified and as directed.
Supply only lubricant oil filter suitable for 25 KVA DG Set, complete all as specified and as directed.
Supply only lubricant oil filter suitable for 10 KVA DG Set, complete all as specified and as directed.
Supply only air filter element suitable for 62.5 KVA DG Set, complete all as specified and as directed.
Supply only air filter element suitable for 50 KVA DG Set, complete all as specified and as directed.
Supply only air filter element suitable for 40 KVA DG Set, complete all as specified and as directed.
Supply only air filter element suitable for 30 KVA DG Set, complete all as specified and as directed.
Supply only air filter element suitable for 25 KVA DG Set, complete all as specified and as directed.
Supply only air filter element suitable for 10 KVA DG Set, complete all as specified and as directed.
Supply & top up water coolant in radiotor of DG set of any capacity any make, complete all as specified and as directed. Make : Bosch/Castrol/TVS Girling/volvo line or of equivelent make all as directed by Engr-incharge.
Cleaning of the fuel tank of DG sets of 62.5/ 50/40 KVA capacity after decaning the diesel, after through cleaning with kerosene oil including replacement of level indicator pipe, complete all as specified and as directed.
All as per item no 27 above but capacity of 30/25/10 KVA
M & L for cleaning/washing the radiator, complete all as specified and as directed.
M&L for replacement of Radiator hose Kit suitable for 50/62.5 KVA DG set, complete all as specified and as directed.
M&L for replacement of Fan belt suitable for 62.5/50 KVA Gen set, complete all as specified and as directed.
M&L for replacement of Fan belt suitable for 40/25 KVA Gen set, complete all as specified and as directed.
M&L for replacement of Fan blade suitable for 40/62.5 KVA Gen set, complete all as specified and as directed.
M&L for replacement of Dynamo 12 Volts, 35 amps as per existing in 25 KVA DG set, complete all as specified and as directed.
Supply and fix in replacement of Lid acid battery 12 volt 75 AH suitable for 50/ 40 KVA DG, complete all as specified and as directed.
Supply and fix in relacement of Power contactor 4 pole 415 Volt, 100Amps Model no L&T MCX-22 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Power contactor 4 pole 415 Volt, 160Amps Model no L&T MCX-32 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Power contactor 4 pole 415 Volt, 63Amps Model no L&T MCX-12 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Auxilary ontact unit 4 pole 415 Volt, 16A Model no L&T MNX-A2 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Auxilary ontact unit 2 pole, 415 Vot, 16A Model no L&T MCX-A1 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Auxilary ontact unit 4 pole, 415 Vot, 10A Model no L&T MCX-A2 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Auxilary ontact unit 2 pole, 415 Vot, 10A Model no L&T MCX-A6 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in relacement of Spare coil for ontact unit 2 pole, 415 Vot, 10A Model no L&T MCX-32 including all electric connections as per existing, complete all as specified and as directed.
Supply and fix in replacement of old unserviceable CT 100/5A ratio, 5 VA, CL-1 of DG set Panel /Feeder pillar box incl connecting, disconnecting and testing complete all as specified and as directed at site.
Supply and fix in replacement of old unserviceable epoxy ype CT 100/5A ratio, 5 VA, CL-1 of DG set Panel /Feeder pillar box incl connecting, disconnecting and testing complete all as directed at site.
M&L in replacement of u/s MCCB o4 pole of capacity 63 to 100 Amps 415 Volts with breking capacity 16 KA, complete all as specified and as directed at site. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB 3 pole 125 Amps adjustable type, 415 Volts, with breking capacity 36 KA, complete all as specified and as directed at site. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB 4 pole 200 Amps adjustable type, 415 Volts, with breking capacity 36 KA, complete all as specified and as directed at site. Make:- L&T/ Legrand/ Scheinder/ Siemens
Supply and fix MCB, Tripple Pole & Neutral, 40-63 Amps, 415 volts, 50 Hz, 16kA, complete all as specified and as directed at site. Make- Legrand, Siemens, Schinder, Havells.
Material and labour for Load balancing of LT panel connected in DG set in all three phases of all outgoings complete all as specified and as directed at under:- a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load. b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit. c) Take the building wise load on the panel and make the load balance at bldg end.
Material and labour for Reconditioning and reconnecting of AMF panel in Various type of DG set including removing of rust particles ad corrotion/ carbon from panel connected items likepower contactor, CTs, MCCB/ MCBs, complete all as specified and as directed.
Supply and fix in Replacement of Off load Change over switch 4 pole, 415 Volt, 100 Ams capacity including all incomming and outgoing electric connectios, complete all as specified and as directed.
M&L in repair of three phase and neutral submain wiring with four single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 10 Sqmm (nominal area) each and one single core 10 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping, complete all as specified and as directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate.
M&L in repair submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 04 Sqmm (nominal area) each and one single core 04.0 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping, complete all as specified and as directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate.
S&F Powerline Vertical TPN DB with suitable for 160A MCCB incomer, double door (IP-54-IK09), 8 Ways, built- in 250 Amps copper busbar for each phase, 2 neutral and 2 earth bar complete suitable for 415 Volts, AC, 50 Hz, complete all as specified and as directed. Make : Legrand (Cat No: 507752)
S&F TPN DB with suitable for TPN MCB incomer, double door (IP-54), 6 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, complete all as specified and as directed.
Supply and fix in repair MCB, Tripple Pole 63 Amps, 415 volts, 50 Hz, 16kA, 'C' curve, complete all as specified and as directed. Make- Legrand, Siemens, Schinder, Havells.
S&F in repair MCB, SP,240 volts, breaking capacity 10 KA, rating, 'C' curve 40 to 63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
Supply and fix in repair sheet metal enclosure double door 4 way DBs SPN, 240V with 200 Amps rated bus bars double door complete in and including of existing electric connection/ circuit, complete all as specified and as directed. Make : L&T/ Legrad/ Semens
S&F in repair sheet metal enclosure for SPN DBs, 8 Ways, Double Door, built in 200 Amps bus bar complete suitable for 240 Volts, AC, 50 Hz complete in and including of existing electric connection/ circuit, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
S&F in repair MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
S&F in repair MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
Excavation in trenches in soft/ loose soil not exc 1.5 mtr wide and not exc 1.5 mtr deep in for lying of electric cable, pole foundation and stays etc and getting out, trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engr-in-charge.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 250mm thick after cable are laid and tested, complete all as specified and as directed.
Removing excavated material (Surplus soil) to a distance not exc 50m and depositing where directed at level not exc. 1.5m above the starting point, complete all as specified and as directed.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, total 23 Cum, complete all as specified and as directed. Note - for measurement purpose punned thickeness 18 Cum shall be considered
S&L sub class B bricks having minimum compressive strength 75 Kg/Sqcm laid in trenches for cable protection etc, complete all as specified and as directed.
M&L Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site cable size of size of 95 Sqmm 3.5 Core, complete all as specified and as directed.
All as per item no 70.00 but for 50 Sqmm 3.5 Core
All as per item no 70.00 but for 35 Sqmm 3.5 Core
All as per item no 70.00 but for 25 Sqmm 4 core
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed.
Dismantiling the incinerator, cleaning completely all the parts and carrying out necessary repair.And re-assembling the incinerator and testing after re-assembling, complete all as specified and as directed.
Material and labour in replacement of burner transformer of incinerator, complete all as specified and as directed.
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of Laundry Machine 30 kg capacity set complete of following ( Dismantiling laundry machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing), complete all as specified and as directed.
All as per item no 77.00 but for Dryer 30 kg capacity
All as per item no 77.00 but for Extractor 15 kg capacity
Supply & fix in replacement of single pointed air termination Alminium rod 12mm dia and 300 mm long incl support block incl taking down u/s, complete all as specified and as directed.
Supply & fix in replacement of single pointed air termination Copper rod 12mm dia and 300 mm long incl support block incl taking down u/s, complete all as specified and as directed.
Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm GI strip incl taking down u/s strip any type, complete all as specified and as directed.
Supply & fix in replacement of aluminium strip 25mmx 3mm as a roof conductor or down conductor complete all with saddles and fixing screws for fitting the strip, complete all as specified and as directed.
M&L for straighting and alignment of existing aluminium strip connected as lightning condoctor in roof/wall in any type of building, complete all as specified and as directed.
Supply & fix in replacement of HDPE/porceiline insulator 15 BMD type T with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc to the wall / floor/pole or any indicated location etc,complete all as specified and as directed.
Supply and fixing in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm , drilled and screwed including 3 nos. 8mm dia 25 mm long hex. head screw, complete with suitable polycaronate box with locking arrangement, complete all as specified and as directed.
M&L for Reconditioning of Lightning terminal by using of required insulators and necessary screwing work in roof and refixing of air termination as per existing, complete all as specified and as directed.
M&L for Reconditioning/ recharging of existing earthing including excavation of earth work upto 1.5 mtr from ground level and removing of soil and old materials near from earthplate as a distance of 300 mm and add salt and coal in a layer of 15 mm from bottem level upto earth plate, reassembling of funnel and water pipe, returning filling of soil and fifing of eath chamber, complete all as specified and as directed.
M&L in replacement of Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron wire 4mm dia by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, complete all as specified and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
SCHEDULE OF CREDIT
GEETA CONSTRUCTION
GARGO TRADERS
SANJAY SAW MILL
SANJAY MITTAL
MS MAYA PRAKASH GOEL AND SONS
S K ENTERPRISES
DEEP CHANDRA JOSHI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .