| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | Admitted-Finance |
| 3 | Admitted-Finance 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | Admitted-Finance |
Tender Value
₹48.5 L
EMD Value
₹97,025
Closing Date
19 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (South West)
GE (South West) New Delhi-03
CONSTRUCTION OF PORTA CABIN (GUARD ROOM AND CARE TAKER ROOM WITH ANCILLARY REQUIREMENTS) AT PLOT NO. 76H, UDHYOG VIHAR, GURUGRAM AND PROVISION OF VIEW CUTTER OPPOSITE SIDE OF VIP ROOM AT ARC MAHIPALPUR AND CSAI MESS MEHRAM NAGAR (RESTRICTED AREA)
2024_MES_658833_1
GE/SW-29/2024-25
Limited
Civil Works
Item Rate
180 days
GE (South West) New Delhi
Class D Category a(i)
7 documents required · 7 mandatory
₹500
GE (South West) New Delhi
₹97,025
Yes
23 Jul 2024
28 Jun 2024
22 Jul 2024
28 Jun 2024
19 Jul 2024
12 Jul 2024
Amount
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil.
Removing excavated material (soils) to a distance exceeding 1.50Km but n.exc 5.0 Km and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5m in depth, for foundation etc and getting out in hard/ dense soil compete all as specified and directed .
Plain Cement Concrete (1:4:8) Type D2 (using 40mm graded crushed stone agg) as in foundation, filling and mass concrete (bed to drain ) complete all as specified and directed.
Removing excavated material to a distance not exceeding 1.50 Km and depositing where directed to a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for brick work with sub-class B brick straight or curved on plan built in cement mortar (1:4) complete all as specified and directed.
M&L for applying 15mm thick plastering in cement mortar 1:4 as on fair face of brick work complete all as specified and as directed.
PCC 1:2:4 Type B1 (Using 20mm graded crushed stone agg) as in coping and the like including weathering, slightly rounded / chamfered angle with and including necessary use and waste of form work for fair faces of concrete complete all as specified and directed.
Returning filling in with approved excavated soil incl spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
S&F rolled mild steel Fe 410-W (Gde?E- 250) quality?A in? framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.
M&L for two coats of synthetic enamel paint, over and including a coat of red oxide primer on new steel surfaces, width or girth exc 10cm including preparation of surfaces complete all as specified and as directed.
M&L Plain Cement Concrete 1:3:6 type C2 (Using 40mm graded crushed stone agg) as in fdn of manholes & filling. Mass concrete around the manholes complete all as specified.
M&L cement mortar concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) incl packing under and haunching against the sides of pipes after they are laid and tested in bores of pipe 200 mm dia complete all as specified and directed.
S&F Reinforced concrete pipes 200mm bore, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L Plain Cement Concrete 1:2:4 type B2 (using 40MM graded crushed stone agg) as in surface channels and drains complete all as specified
Supply only liquid water proofing admixture complete all as specified and directed.
S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers and similar articles exc 5 Kg each complete all as specified and directed.
M&L Extra for finishing fair finished drain or channel, 30cm inner girth in cement concrete using extra cement incl. forms, moulds, mitred/stopped ends etc. all as specified and directed.
M&L for on site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, RCC cover with manhole, connection, etc. complete for 10 users (as per standard drg & specifications) all as specified and directed by Engr-in-Charge.
M&L for hard core of guage not exc 63mm of broken stone deposited spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface.
M&L Plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in sub base complete as specified.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed.
M&L for providing cement concrete type B-1, 1:2:4 (using 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as specified & directed.
S&F Prefab shelter of size 11.52m x 3.70m, with 3.00 metre height from floor level to bottom of truss, inclusive of necessary foundation & platform, with following specifications including all fittings and fixtures complete all as specified & directed. Note: 03 Nos partition walls of 3.60 m length, 01 No partion wall of 1.50 m length between bathroom & WC and 01 No partion wall in kitchen of 2.40 m length with a opening of 0.90 m x 2.00 m will be provided as part of this prefab shelter. Height of partition walls shall be equal to front & rear walls. Make: M/s Porta Cabin Engineers Pvt Ltd/ Shree Porta Builders Pvt Ltd/ M/s Startrek Structures/ M/s Makeover Interiors.
(i) Foundation/platform: Prefab shelter shall be placed on PCC Platform. Dwarf wall shall be provided all-around of shelter with old size sub class 'B' bricks in Cement Mortar 1:4 over 100mm thick PCC 1:4:8 foundation concrete. Width of PCC below dwarf wall shall be 430mm & shall be 300mm below GL. Plinth band of size 230 x 300 mm shall be provided over the dwarf wall in RCC 1:2:4 type B1 (using 20mm graded aggregate) and reinforcement 2 Nos 12 mm dia tor mild steel bars at top & bottom with 8mm dia strips @ 150 mm centre to centre. . Necessary fixing arrangement (Anchor plate and Anchor bolts etc) for prefab shelter shall be provided as per manufacturer's instructions. 75 mm thick PCC 1:3:6, type C-2, using 40 mm graded stone aggregate over 100 mm thick hardcore of gauge n exc 63 mm broken stone over and including consolidated earth filling shall be provided for Platform. Overall height up to top of PCC 1:4:8 shall be 300 mm from Ground level. This includes all the earth work for porta cabin such as surface excation, excavation in trenches, returning/filling in, removal of surplus soil, etc.
(ii) 50mm Aeracon Walls: 50 mm thick pre fabricated panel made out of light weight concrete core composed of portland cement, binders, silicious & micaceous aggregate with Tongue & Groove arrangements with two fibre reinforced cement facing sheets of thickness 4 mm on either side of core. Internal facing sheet in kitchen & toilet portion will be of 6 mm thick PVC panels.
(iii) Floor: 10 mm thick Vitrified tiles of approved brand, light shade (Colour & shade of tiles shall be approved by the GE), of minimum size 600X 600 mm except kitchen & toilet where non skid 300 x 300 mm x 7mm thick tiles will be provided, over and including 20 mm thick screeding in cement mortar 1:4 and pointed in white or colour cement to match.
(iv) Roof: The Structure/shelter shall be provided with of 0.5mm thick PPGI Sheet including 50mm thick Glass wool between the roof and ceiling with self drilling Screws as per manufacturer's instructions, resting on the purlins on and including MS truss. The roof shall have a projection of 500mm beyond external face of wall. Sheets shall be fixed to MS Purlins using self-tapping screws. Prepainted galvalume steel sheets used shall be as per IS specification and shall be fixed with self tapping screw @ 100mm centre to centre, over and including mild steel Rectangular Hollow Pipes purlins made out of size 63.50mm X 38mm, 2.9 mm thick, placed @ 900mm centre to centre. 04 Nos Trusses shall be provided as per design as approved by the GE and shall be made out of mild steel Rectangular Hollow Pipes of size 80 mm X 40 mm, 3 mm thick. columns below the both ends of all trusses, shall be provided and shall be made out of mild steel Rectangular Hollow Pipes of size 100mm X 50mm, 4.05 mm thick and shall be welded or fixed together with the help clamps, washers as required complete. Roof is to be laid to a minimum slope of 1:5. Trusses, purlins and columns shall be welded/fixed together with the help of clamps, washers as required and as per manufacturer's instructions complete. Ridges shall be made of 0.50mm thickness plain pre painted GI Sheet fixed with self tapping screws @ 100mm centre to centre. Ridge shall be placed to maintain required slope.
(v) External/Internal Painting: All steel surfaces shall be painted with two coats of synthetic enamel paint over and including a coat of red oxide primer. All internal surfaces of wall shall be painted with two coats of oil bound distemper over and including a coat of cement primer. The external surfaces of walls shall be painted with two coats of weather proof exterior emulsion paint (Apex Ultima) or equivalent make as specified over and including a coat of cement primer.
(vi) Door: All Doors shall be Powder coated aluminium door shutters with frame, aluminium section weighing 0.55 kg/m including 12mm thick prelaminated (both sides) PVC boards with decorative choice veneers in panels , necessary joining cleats, clips, packing, handles 2 Nos in each door, hinges 100 mm long 03 Nos in each door, anodised aluminium snap beading, aluminium sliding bolt 300 mm in each door, Tower bolt 150 mm 02 Nos in each door, screws etc complete all as specified. Size of Door shall be 0.90 m x 2.10m (03 Nos) and 0.75 m x 2.10 m (02 Nos).
(vii) Window/Vents: All Windows shall be Powder coated aluminium sliding glazed windows with 5 mm thick tinted glass. Stainless steel mosquito proof wire netting & Aluminium Deco grill shall be provided on all windows and Vents. Size of window shall be 0.90 m x 1.10m (05 Nos) and size of vents will be 0.50m x 0.75 m (02 Nos).
(viii) False Ceiling: Gypsum tile false ceiling 6mm thick in 600X600mm (5mm variation on plus/minus side permitted) panel designer ceiling conforming to IS 14862 type B category 3 including GI frame, grid work, hold fast, suspenders, etc complete.
(ix) Toilet: Toilet will be comprising of separate bath & WC portions. Sanitary & plumbing items will be measured & paid separately.
(x) Kitchen: Kitchen will be divided in store & pantry portions. Both the portions will be provided with 0.60 m wide 18 mm thick granite platforms. One additional shelf will be provided in store portion of same granite. Sanitary & plumbing items will be measured & paid separately.
(xi) Electrical Work: Electrical Work shall be measured & paid separately.
(xii) Curtain Rails: Decorative curtain rails powder coated 25 mm dia with accessories will be provided over all doors & windows openings except in toilet.
M&L for 75 mm PCC 1:3:6 type C-1 (20mm graded stone agg) as in plinth protection/hard standing and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. fair finished surfaces complete all as specified & directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished complete all as specified.
S&F Mild steel (TMT) bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified & directed.
M&L brickwork with using sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified & directed.
M&L for providing cement concrete type B-1, 1:2:4 (using 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, dpc/plinth courses (using WPC), string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028 of SSR Part II, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as specified & directed .
S&F wall/door mount stainless steel superior quality anti rust peg sets (set of six solid pegs) highly polished including all screws and plugs required for installation of peg sets of shape & size as directed by Engr-in-Charge.
M&L for finishing new walls with two or more coat of acrylic smooth exterior emulsion weather coat first quality of required shade over a coat of exterior primer including necessary preparation of surface including a coat of 1mm thick wall care putty etc complete all as specified & directed.
S&F sink with drainage board made of 1mm thick stainless steel, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. (Make : Nirali/Joyna/Bluestar/Prayag)
S&F Salt-glazed stoneware gully traps of size 150x100mm, square or round mouthed, type 'P' include setting and jointing to drains with cement mortar 1:1. & all excavation and earthwork, concrete in beds, surrounds, kerbs, etc. and cast iron grating, etc complete.
S & F 15 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S&F 15 mm bore chromium plated fancy type stop cock with long shank and cup (concealed type)/angle cock complete all as specified.
S&F 32 mm outer dia CPVC SDR -13.5 including all fittings and fixed complete to walls/ceilings or laid in trenches. (Make- Supreme or equivalent) complete all as specified.
S&F 20 mm outer dia CPVC SDR -13.5 including all fittings and fixed complete to walls/ceilings or laid in trenches. (Make- Supreme or equivalent) complete all as specified.
S &F brass chromium plated tubular towel rail 20mm dia, D type, 60cm long between flanges all as specified.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long.
S&F Soap dish, vitreous China white, approximate size 160x 160x90 mm complete all as specified and as directed.
S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified.
S&F PVC (SWR) floor trap, plain with grating including jointing fixed in cement concrete type B1 (1:2:4) out let dia 75mm complete.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls using PVC clamp suitable for 110mm bore PVC (SWR) pipe complete.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110mm bore complete.
S&F PVC (SWR) bends 75mm bore any radius with access door including jointing with solvent cement complete all as specified.
S&F PVC (SWR) bends 110mm bore any radius with access door including jointing with solvent cement complete all as specified.
S&F PVC (SWR) Cowl 110 mm bore
M&L for first manhole 90cm deep including excavation, PCC as in foundation, brick work in CM 1:4, PCC 1:2:4 as in haunching benching, plastering in CM 1:4, cast iron manhole cover with frame of 500mm dia etc complete.
S&F Wash down water closet (Pedestal pattern) using vitreous China wash down water closet pan , white including fixing bolts, flushing cistern and flush pipe) PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern, Plastic water closet seat, white, recessed bottom pattern and cover and mild steel chromium plated or aluminised hinging device etc complete all as specified & directed.
S&F health faucet with 1 m long flexible tube in brass CP finish in cluding wall hook for EWC complete all as specified & directed.
S&F Toilet paper holder of brass, chromium plated or stainless steel fixed to walls with chromium plated (CP) brass screws.
S&F white, vitreous china, wash hand basin, flat back, size 550 x 400mm including brackets complete including making good the surface/ joints with white cement complete all as specified and as directed.
S&F white, vitreous china pedestal for wash hand basin of size 550 x 400mm including brackets complete including making good the surface/ joints with white cement complete all as specified and as directed.
S&F brass chromium plated shower rose 65 mm dia with swivel joints including fixing to steel pipe or union.
S&F Brass CP mixer for mixing hot & cold water (for shower/basin/sink) screwed down for iron pipe of 15 mm dia all as specified & directed.
S&F 450mm long PVC connection with CP brass nuts & PVC/ rubber washer suitable for 15mm bore tap/ pipes complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity including 25 mm thick brass float valve set hoisted and fixed in position all as specified.
S&F PP-R Gate valves (brass insert) in 32 mm outer dia of pipe as per requirement of the site all as specified.
S&F wall mounted stainless steel plate rack cum dish drainer of size not less than 75 cm x 90 cm x 18 cm (weight not less than 4 kg) of approved brand, glossy finish and anti rust complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces complete all as specified and directed.
Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L RCC 1:2:4 as in Beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs etc. or in similar articles complete all as specified and as directed.
S&F mild steel plate (plain or chequered) channels, square cut or notched (ordinary and counter sunk ) forming holes with welded attachment to GI pipe in base/connections etc. complete all as specified and as directed.
S&F Mild steel bolts, dia of neck exc 12mm but n.exc 20mm purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 60cm long complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 with one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and as directed.
S&F twin wall UV coated polycarbonate roof sheets 10mm thick of the colour/shade as approved including providing and fixing screws, washers/neoprene gasket, adhesive, etc as per manufacturer's instructions complete all as specified and as directed.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)over 3mm thick wall care putty including material and labour charges etc. for external walls. Make: Asian paints, Berger, Acro paints. complete all as specified and as directed.
M&L for removing excavated/ demolished soil/ material exc. 10.00 km and depositing where directed complete all as specified and directed.
S&F 75mm thick factory made SFRC manhole/ drain covers of approved shape & size complete all as specified and as directed. Make : Polycrete or equivalent.
Excavating in post holes (or similar holes) each in soft/loose soil n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L for RCC (Nominal Mix) type B1 1:2:4 Using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L in replacement of point wiring for modular switches or normal switches with 2X1.5 sqmm, single core, multi stranded copper conductor PVC insulated unsheathed cable 1100 Volts grade, drawn through concealed rigid non-metallic PVC Conduit with all fittings of suitable size of dia as required at site including cadmium plated screws as per IS and replacement of 3 mm thick phenolic laminated sheet top covers, modular cover plate on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/fan point controlled by one switch 5 Amps one way single pole complete all as specified and directed. Make of cable-Havells/ Standard/ Polycab.
All as per item No. 80 above but one three pin 5 Amps socket out let on independent board. Make of cable- Havells/ Standard/ Polycab.
All as per item No. 80 above but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sq mm PVC insulated unsheathed copper cable as earth continuity conductor.
All as per item No. 80 above but, point wiring of copper cable multi stranded 2x2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed. Make -Havells/ Standard/ Polycab.
S&F Modular switch 1 way 6 A, 240 volt, 1 module complete all as specified and directed. (Make : Anchor Roma /Legrand/Crab tree)
S&F Modular switch 1 way 16 A, 240 volt, 1 module complete all as specified and directed. (Make : Anchor Roma/ Legrand/ Crab tree)
S&F Modular socket outlet 16 A240 volt, 2/3 pin, combined 2 module complete all as specified and directed. (Make- Anchor Roma/Legrand/Crab tree)
M&L in replacement Sub main wiring complete with 4 run of 10 sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade, drawn including PVC concealed/ surface conduit along walls roofs etc including 10 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Make - Havells/ Finolex/ Polycab/Plaza/L&T/ANCHOR
Supply & Fixing in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP 25 Amp of capacity 20P+E Amps complete all as specified and directed. Make- Havells/ Legrand/ L&T/ Schneider
S&F electric driven Invertor type Split Air Conditioner 2Ton capacity,240 volts, BEE 3 star rated including rotary type compressor, high EER, copper material condenser unit, eco friendly refrigerent etc with all accessories complete in all respect all as directed. (Make : Hitachi/ LG/ Voltas/ Blue Star)
S&F ceiling rose 2 to 3 terminals 6 Amp, 240 Volt, and connection complete all as specified.
S&F distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double dooor, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCB 63/100 Amps TPN as incomer and MCB SP as out going complete and making good disturbed surface all as directed. Make : Legrand/Schneider/Hager/Siemens
Supply only in replcement MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete Make : Legrand/Schneider/Hager/Simens.
Supply only in replacement MCB DP/SPN, 240 Volts, AC of breaking capacity 10 KA, 63 Amps, 'C' curve and connections by using suitable copper lugs complete. Make : Legrand/Schneider/Hager/Simens.
Supply and fixing ceiling fans completewith blades, down rods, electronicregulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) ®
S&F modular step type fan regulator 120 watt, two module socket type, complete all as specified and directed. Make: Anchor Roma/ Crabtree/ Legrand/ Schneider/ L&T/ GE/ Capsal.
Earthing complete with Galvanised Steel earth plate of size 60x60cmx6.3mm thick electrode and 4mm GI wire as earthing lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 4mm GI wire by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
Supply fixing and testing electric operated horizontal storage type water heater (Geyser) 25 Ltr capacity 230 Volt, AC including nylon braided PVC connection pipe suitable for 96 degree tempretaure and pipe fitting complete. Make- Havells (Model - Monza dx)
S&F in repair LED Bulkhead luminaire 10 watt of polycarbonate housing and enclosed with acrylic diffuser IP-65 protection incl connection complete all as specified & directed. Make: Havells/Wipro/Philips/GE
M&L in replacement Sub main wiring complete with 2x4 sqmm, single core, multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade, drawn including PVC concealed/surface conduit along walls roofs etc including 4 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Make - Havells/ Finolex/ Polycab/ Plaza/ L&T/ ANCHOR
Supply and fixing automatic electronic voltage stabilizer,single phase, incoming voltage 170-270 volts and outgoing voltage 220/230 volts suitable for 2 Ton Split AC all as specified. Make - V Guard/Blue bird/Capri power/Microtek/Candas
S&F in replacement LED Recess mounted 2x2 ft luminaire fitting LED warm white(WW) 34/36 Watt cast aluminium housing, toughened glass, silicon gaskect, 3000K high power LED with lens for uniform istribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed. (Make - Havells Cat No:- STRATO2X2PLR36WLED830MOD or equivalent in Philips/ Wipro)
JIWAN DASS THAREJA AND SONS
Singh Associates
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .