| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹13.5 L+₹57,501.33 (4.45%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹13.9 L+₹92,837.46 (7.18%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹14.2 L+₹1.3 L (10.1%)Rejected-Finance BAZAR RAM SUKH DASS FEROZEPUR CITY 152002 PB | FIROZEPUR | PUNJAB | 152002 | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹14.3 L+₹1.4 L (10.5%)Rejected-Finance 36 THE MALL FEROZEPUR CANTT 152001 | FEROZEPUR CANTT | FEROZEPUR | PUNJAB | 152001 | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
8 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Ferozepur Cantt
HQ CWE Ferozepur Cantt
CWE/FZR-46/2020-21 Provn of augmentation of power supply to Saragarhi Enclave under GE (East) Ferozepur Cantt
2020_MES_390131_1
CWE/FZR-46/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ferozepur Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (East) Ferozepur
₹29,000
Yes
17 Dec 2020
12 Nov 2020
10 Dec 2020
12 Nov 2020
8 Dec 2020
3 Dec 2020
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan for laying of cable and getting out,compete all as specified.
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified.
Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately). Note- Punned down thickness shall be measured.
S&F in repair Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified. (Excavation and earth work measured separately).
Supplying, laying and testing XLPE insulated, armoured, HT 11000 volts grade, heavy duty cable of size 120 Sqmm nominal cross section, 3 core, flat or circular, insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified.
M&L air break outdoor gang operated switch, triple pole, mechanically operated, with contacts of ferrous knife and spring loaded moving contact of copper, horizontal or vertically mounted, (12 insulator type) mounted on insulator and steel frame with operating mechanism including 25mm bore medium grade GI pipe to worked from ground level for current rating up to 200 Amps HT 11 KV with locking mechanism, mild steel clamp, nuts, bolts, washers, operating handle with in both OFF and ON position of required size including two coats of aluminum paint over a coat of red oxide, complete all as specified.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm, complete all as specified and directed.
Supply, installation, testing and commissioning AC, 3 phase, 50 HZ, 315 KVA capacity transformer copper wounded step-down Outdoor type 11000/433 Volts (at no load) double wound oil immersed naturally cooled with external cooling tubes, core type delta connected on primary side(HV) and star connected on secondary side (LV) in accordance with vector symbol DY-11(Vector Group with neutral brought on secondary side (LV side) and having tapping at +/- 2.5%, +/-5.0% and +/- 7.5% to be changed by means of hand operatd off load tap chaning gear. The maximum centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be confirming to IS-1180 2014 level-2 BIS mark including first filling of fresh transformer oil conforming to relevent IS tested not less than 60 KV dielectric strenght at 2.5 mm gap and and comprising with the following standard fitting/accessories. (a) One cable box on LT side (Secondary side) consisting of four No's porcelain with copper bushing rods complete with nuts and washers with one No cable glands suitable for reception of taking out 01 No 3.5 core, LT 1100 Volts grade, PVC sheathed and PVC insulated heavy duty armoured cable including gland joint and jointing materials complete. (b) Oil conservator with filter type drain valve and oil level gauge. (c) Dehydrating breather with first fill dehydrating agant (Silica Gel). (d) Explosive vent. (e) Thermometer pocket on tank cover. (f) One cable box on HT side with cover. (g) All other standards accessories as specified in relevent IS.
M&L for plinth of transformer of size 2.1x2.1x1 mtr including excavation work, PCC 1:4:8 type D2 (using 40 mm graded stone aggreate) for foundation, Brick work with sub class 'B' bricks and rendering of 15 mm thick cement plaster on of brick/concrete work, sand filling for foundation, Moorum/red bujri filling in floor and hard core of brroken bricks of gauge n exc 63 mm depsited, spread and fiiling in layers and cement conerete type C-2, 1:3:6,150 mm thick and Cement concrete type B-1, 1:2:4, 100 mm thick, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size size 400 Sqmm 3.5 core confirming to IS 7098-1985, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size size 300Sqmm 3.5 core confirming to IS 7098-1985, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size size 70 Sqmm 3.5 core confirming to IS 7098-1985, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size size 50 Sqmm 3.5 core confirming to IS 7098-1985, complete all as specified and directed.
S&F in repair Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, concealed in wall, VTPN DB with 200 Amps rated bus bar, 6 way, 415 volts, vertical type, dust and vermin proof, Including MCCB of 125 Amps,16 KA suitable for incorporation of MCCB/MCBs duly concealed in wall, factory made including making good distrubbed surfaces with matching colour, complete all as specified.
S&F MCB, TPN, 63 Amps, 415 volts 50 Hz, 10 KA, duly ISI marked, complete all as specified.
S&F MCB, SPN, 40 Amps, 240 volts 10 KA, duly ISI marked, complete all as specified.
M&L Earthling and as specified including the following:- (i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level. (ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer). (iii) 32x6 mm dia GI earth srtrip from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc. (iv) 50 mm bore light grade, GI pipe for protection to earth-strip. (v) 20mm bore, light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed.
M&L Earthing as in repairs complete, all as shown on electrical plate No 3 of MES schedule part-I, and as specified including the following:- (i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level. (ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer). (iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc. (iv) 15 mm bore light grade, GI pipe for protection to earth-strip. (v) 20mm bore, medium grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified.
Vee Vee Enterprises
M/S Yashpaul Gulati
RAKESH KUMAR SATISH KUMAR
Harmesh Kumar Sharma and Sons
M/S Pee Kay Builders
M/s Sham and Company
Marwaha Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .