Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.7 L+₹54,778.59 (1.95%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹29.9 L+₹1.7 L (6.20%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹33.7 L+₹5.6 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹64,800
Closing Date
6 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NARANGI
GE Narangi C/O 99 APO Guwahati
PRON OF CERTAIN MW, RW AND LBW WORKS UNDER GE NARANGI.
2021_MES_435196_1
8612/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NARANGI
₹64,800
Yes
18 May 2021
8 Apr 2021
10 May 2021
8 Apr 2021
6 May 2021
22 Apr 2021
60 days
Amount
SCHEDULE 'A' PART-I
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in soft/loose soil complete all as specified and as directed.
All as per item No.1 here in before but depth exceeding 1.5 m but not exceeding 3m.
Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed.
Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
Material and labour for for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, punning completed all as specified and as directed. Note:Punned thickness will be measured and paid.
M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable for protection of LT cable complete all as specified and as directed.
M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1: 3 : 6 type C-1 (using 20 mm graded stone aggregate) as in coping for the new/existing Steel Poles, cills, including necessary formwork (straight or curved) complete all as specified and as directed.
Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
All as per Item No 9 here-in-before but size of cable 10 sqmm 2 core, complete all as specified and as directed.
M&L for manual boring of holes under road,pavement, hard standing where ordered for inserting GI pipe 40 mm dia complete all as specified and as directed (Note : - GI pipe 40 mm dia will be measured & paid seperately.)
S&F GI tube light grade of size 40 mm bore dia conforming to IS 1239 of 1990 for for protection of LT cable laid in trenches/under road,pavement, hard standing or fixing on wall/pole etc. complete all as specified and as directed
Supply, errecting & fixing in true vertical position, steel tubular swaged poles type 410 SP 31 (9.00 meters long) conforming to IS-2713 complete with cast iron base plates, finial taper plug, bolts, nuts & screws and painted with two coat of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminuum paint over a coat of red oxide primer complete all as specified and as directed.
S&F street light bracket made of GI pipe 40 mm bore light grade(bend to shape) , 1.5 meter long and fixed with mild steel flat iron clamp(clamp shall be 50 X 6mm ), nuts, bolts and washers on pole, wall etc for fixing LED street light fitting complete duly painted with two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed.
S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening separate driver compartment ,should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 10kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage complete all as specified and as directed. Make :- Magic Cat Part No. SPOR060C0805 or equivalent in crompton & Philips
S &F street light fitting of 90 Watt LED made of pressure die cast aluminium housing with toughened glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening separate driver compartment ,should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 10kV complete also tested for 440 Volt for 48 hour Phase to phase without any damage complete all as specified and as directed. Make :- Magic Cat Part No. SPOR090C0809 or equivalent in crompton & Philips Note: For Item No. 16 & 17 (i) PVC insulated PVC sheathed, multi stranded aluminium or aluminium/copper conductor cable of size 1.5 sqmm X 3 core from light fitting to Street light feeder (max 3 meter ) deemed to be included in quoted rate. (ii) The Contractor shall mark his firm’s name and CA No. on the LEDs light fittings in good handwriting with permanent marker.
S&F for thermoplastic(polycarbonate)circuit breaker boxes where MCB to be fix with PE+N terminals 1 row 4 module of size 126X228X111 mm IP 65 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation with four pole MCB , C - curve .breaking capacity 10kA with rating 16 Amp all as specified and as directed. Make :- Hensel Cat Part No. KV 7104 or equivalent in syntex
S&F factory made, sheet steel distribution boards, IP-43 of double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt including 63 Amp, 25 KA,FP MCCB as incomer, grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed. Make-Legrand Cat Part No. 5077 45 or equivalent make of Schnieder / L & T
S & F sheet metal enclosures IP-44 triple pole and earth plug with socket complete with one four pole MCB of capacity 32 A , 415 V complete all as specified and as directed.
S&F Sheet metal enclosure with two pin and earth plug and socket complete with one MCB DP upto 32 Amps, having `C` charactristic, breaking cap 10 KA, 240 Volts capacity complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Cat No 4085 87 to 4085 95 or equivalent model of make Hager/ Siemens/ ABB/ Schneider/GE/C&S Electricals Ltd.
S&F street light junction box of size 155 x210x92mm made of high quality polycarbonate with IP-66 protection (Dust and vermin proof according to IEC-60529) Totally insulated made of halogen and silica free recyclable material having high quality gasket made out of polyurethane with MCB, DP, 10KA, 6 Amps to be fixed on Din rail , with locking arrangement with cable gland suitable upto 10 sqmm cable and necessary fixing arrangements such as clamps, nuts, bolts etc complete all as specified and as directed. Make : Hensel Cat No -KF-1610B equivalent in syntex.
M&L for connection of junction box to street light luminaries using wiring with two runs (P-N) of single core 1.5 Sqmm (nominal area) FR PVC insulated and unsheathed multi-stranded copper conductor cable 1100 volts grade and one run of FR PVC insulated and unsheathed multi-stranded copper conductor of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit(Heavy grade) and tiding the same by aluminium strip with the pole complete all as specified and as directed. (Two single core 1.5 Sqmm cable and one single core 1.5 Sqmm earth conductor cable and one run of PVC conduit shall be measured as one run).
M&L for sub main wiring with two runs (P-N) of single core 4.0 Sqmm (nominal area) FRLSH PVC insulated and unsheathed copper conductor cable 1100 volts grade having multi-stranded copper conductor with earthing cable of FRLSH PVC insulated and unsheathed multi-stranded copper conductor green colour of size 4.0 sqmm single core as earth continuity wire drawn through adequate size PVC non-metallic conduit complete all as specified and as directed. Note : Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth continuity conductor and one run of PVC conduit shall be measured as one run length.
M & L for Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as required along with one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and as directed.
Supply, Installation , testing and commissioning of Air conditioner unit, inverter type (variable speed) of 1.5 TR capacity (Split type unit comprising of indoor and outdoor unit) electrically driven (single phase 230 Volt, 50 Hz) and with inbuilt air ionizer and plasma filter for better indoor air quality with BEE 5 star rating , super energy efficient having ISEER rating at least 5.41, precision cooling technology, shall have cooling capacity of 18000 BTU/Hr including necessary fixing arrangement complete (indoor unit at suitable place and height inside the room and outdoor unit at suitable place ) including refrigerant copper pipe, bracket fabricated using MS angle iron not less than size 50x50x6 cm including necessary nuts, bolts washer etc as required at site for mounting outdoor unit of AC on wall complete all as specified and as directed. Make: Bluestar Model: IC718DCTU or equivalent make in voltas/LG/Hitachi.
Supply, installation, testing and commissioning of Air Conditioner inverter type (Variable speed) unit of 2 TR capacity (Split type unit comprising of indoor and outdoor unit) electric driven (start single phase 230V, 50Hz), with minimum cooling capacity 21599 BTU/Hr and with inbuilt air ionizer and plasma filter for better indoor air quality and eco friendly refrigerant with BEE 5 star rating, ISEER 4.56 rating cordless remote control for operation, including necessary fixing arrangement i.e bracket of suitable size for complete fixing , indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) including refrigerant copper pipe, bracket fabricated using MS angle iron not less than size 50x50x6 cm including necessary nuts, bolts washer etc as required at site for mounting outdoor unit of AC on wall complete all as specified and as directed. Make:- Bluestar Model: IC524DBTU or equivalent in Voltas/LG/Hitachi.
S&F Voltage stablizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stablized at 200 V to 240 V with accuracy of 2% and of current carrying capacity 5 KVA complete all as specified and as directed. Make: V-Guard VG500 or equivalent make of Vertex/Volin
M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 25 X 4mm dia GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal, salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
M&L for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to copper strip 20 X 3 mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, watering pipe of 40 mm bore, light grade GI pipe, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, disposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and as directed. NOTES 1). The unit rate include copper strip from top of earth plate upto 7.5 meter above ground level.
M&L for Advance encapsulated compound based Chemical earthing CPRI tested maintenance free , pipe in -pipe technology upgraded (Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2mm and 41.9mm dia respectively of 3 meters long zinc coated with additional special alloy coating 300mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compact fill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity .The job includes digging the pits ,lowering the pipe in pipe earth electrode, filling of pure conductolite back filling compound (BFC Conductolite ) having excellent moisture retaining capacity in 250 mm around the electrode min 4 bags of 25 KG per pit per unit. The BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colour complete all as specified and directed. Make : ASHLOK ( Model ASEEL-39 AC 3 miter length 76.3 mm dia Note :- (i) Design of earth electrode should be of pipe in-pipe technology . (ii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current. (iii) Contractor has to fill pure back fill compound 250 mm all around the earth electrode up to full depth of pit. (iv) Contactor shall submit the test report of earthing after satisfactorily completion
M & L for fabrication of MS board for display earth pit nos, location and periodical test results for lightening arrester earthing, made of MS sheet 4.0 mm thick, rectangular in shape welded on 12 mm dia rod of height from ground level 30 cm including fixing in PCC 1:2:4 of dimension 20 cm X 20 cm X 20 cm (below ground level)with 20mm grade aggregate . Dimension of board shall be 30 cm X 25 cm. complete all as specified and as directed. Note : (a) All necessary MS sheet, aluminium screws and PCC works etc are deemed to the rate quoted by the contractor
M & L for Air termination, single pointed, aluminium rod 12mm dia and 300mm long to be fixed on horizontal lightning conductor with suitable fixing arrangement including taking down old one complete all as specified and as directed.
M&L for copper strip 30 x 3 mm with DMC /porcelain saddle at the distance of 0.5 RM to support copper strip and fixing screws etc. for earth continuity conductor in ground / wall or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and as directed.
M & L for copper strip 20 x 3.15mm with "V" type porcelain insulator or DMC insulator of suitabe size and fixing with GI screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F for thermoplastic(polycarbonate) junction box for test point without terminal block of dimension 130x180x77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block to test point junction box complete all as specified and as directed.
PURBANCHAL BUILDERS
M/S SEWAK SINGH
M/S RAJ RANI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .