| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹194.6 CrAdmitted-Finance 3 6 213 SRIDHAR VELAGAPUDI PLOT NO 169 ROAD NO 11 94904 HYDERABAD TELANGANA 500096 | HYDERABAD | TELANGANA | 500096 | L1 | Admitted-Finance | |
| 2 | L2₹211.7 Cr+₹17.0 Cr (8.76%)Admitted-Finance 20 IT PARK | L2 | Admitted-Finance | |
| 3 | L3₹215.7 Cr+₹21.0 Cr (10.8%)Admitted-Finance LB SHILPANGAN CF BUILDING SALT LAKE NORTH 24 PARGANAS WEST BENGAL 700098 | 24 PARAGANAS NORTH | WEST BENGAL | 700098 | L3 | Admitted-Finance | |
| 4 | L4₹226.4 Cr+₹31.8 Cr (16.4%)Admitted-Finance NAVKAAR PARISAR PULGAON NAKA DURG CHHATTISGARH 491001 | DURG | DURG | CHHATTISGARH | 491001 | L4 | Admitted-Finance | |
| 5 | L5₹315.8 Cr+₹121.2 Cr (62.3%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Maheshwari Mining Pvt. Ltd. L3 | DCS Limited L1 | R K TRANSPORT COMPANY L4 | S K KHETAN INFRAPROJECTS PRIVATE LIMITED L5 | ACC MINING PRIVATE LIMITED L6 | SMS LIMITED L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation of drives/cross cut of size 5.5m wide x 4.0m high at various levels including drilling, blasting, muck removal, dewatering to any extent and disposal at surface within a distance of 2.5 km radius from portal/shaft top, ventilation, scaling down of loose rocks, RCC M 20 nominal drain of 300 mm x 300 mm (width x depth) for full length of drive, water line (2" GI] with 1 inch audco plug valve at an interval of 200m distance, hanger above 3.0 m height to avoid any accidental damage for laying pipes and cables opposite to cross-cut, light fittings of LED bulb of suitable wattage to ensure minimum lux as per the statute at every 6 m interval and manholes as per MMR 1961 and ground support by resin grouted rock bolts of 2.4m long 1.2m grid of 22mm tor steel with 150x150x6 mm bearing plate and 150 mm threaded tightened with nut in rows as per SSR and design approved by the engineer in charge. | 400 | Metre | 1,38,160 ₹5,52,64,000 | 1,17,000 ₹4,68,00,000 | 1,30,000 ₹5,20,00,000 | 1,87,114 ₹7,48,45,600 | 2,09,000 ₹8,36,00,000 | 1,10,000 ₹4,40,00,000 Lowest |
| 2.10 | Drives/Crosscuts / Draw points: Excavation of extraction drives, crosscuts and draw points of following sizes at different levels including drilling, blasting, muck removal, dewatering at any extent and disposal at surface within a distance of 2.5 km radius from portal/shaft top, ventilation, scaling down of loose rocks, proper drain (kachha Drain) for full length of drive, manholes as per MMR 1961 and ground support by resin grouted rock bolts of 2.4m long 1.2m spacing in a row and 1.2m spacing within two rows of rock bolts of 22mm tor steel with 150x150x6 mm bearing plate and 150 mm threaded tightened with nut as per SSR and design approved by the engineer in charge for 4.5m wide X 4.0m high | 5,900 | Metre | 1,13,040 ₹66,69,36,000 | 98,100 ₹57,87,90,000 Lowest | 1,15,000 ₹67,85,00,000 | 1,51,619 ₹89,45,52,100 | 1,71,000 ₹1,00,89,00,000 | 1,01,000 ₹59,59,00,000 |
| 2.20 | Drives/Crosscuts / Draw points: Excavation of extraction drives, crosscuts and draw points of following sizes at different levels including drilling, blasting, muck removal, dewatering at any extent and disposal at surface within a distance of 2.5 km radius from portal/shaft top, ventilation, scaling down of loose rocks, proper drain (kachha Drain) for full length of drive, manholes as per MMR 1961 and ground support by resin grouted rock bolts of 2.4m long 1.2m spacing in a row and 1.2m spacing within two rows of rock bolts of 22mm tor steel with 150x150x6 mm bearing plate and 150 mm threaded tightened with nut as per SSR and design approved by the engineer in charge for 4.2m wide X 4.0m high | 12,200 | Metre | 1,05,504 ₹1,28,71,48,800 | 94,500 ₹1,15,29,00,000 Lowest | 1,10,000 ₹1,34,20,00,000 | 1,40,970 ₹1,71,98,34,000 | 1,59,600 ₹1,94,71,20,000 | 99,000 ₹1,20,78,00,000 |
| 3.00 | Procurement and installation of rigid wire-mesh of 10 cm * 10 cm mesh size of 5-6 mm dia. wire including Fibre reinforced Shotcrete 100 mm thickness (underground) with all material as per SSR and design approved by the engineer in charge. | 64,000 | Sq. Metre | 2,300 ₹14,72,00,000 Lowest | 2,619 ₹16,76,16,000 | 3,000 ₹19,20,00,000 | 7,319 ₹46,84,16,000 | 5,800 ₹37,12,00,000 | 4,200 ₹26,88,00,000 |
Tender Value
Refer Docs
EMD Value
₹50 L
Closing Date
1 Nov 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER (COMMERCIAL)
TAMRA BHAVAN, 1 ASHUTOSH CHOWDHURY ABVENUE, KOLKATA - 700019
MINE DEVELOPMENT OF SOUTH SECTION OF MALANJKHAND COPPER MINE, MADHYA PRADESH, INDIA
2023_HCL_168060_1
HCL/M AND C/CO/MCP-UG/DEV/SOUTH
Open Tender
Mining
Works
1460 days
MALANJKHAND
AS PER TENDER
4 documents required · 4 mandatory
₹0
₹50 L
Yes
KOLKATA
4 Dec 2023
18 Sept 2023
2 Nov 2023
18 Sept 2023
1 Nov 2023
19 Sept 2023
3 Oct 2023
Amount
Excavation of drives/cross cut of size 5.5m wide x 4.0m high at various levels including drilling, blasting, muck removal, dewatering to any extent and disposal at surface within a distance of 2.5 km radius from portal/shaft top, ventilation, scaling down of loose rocks, RCC M 20 nominal drain of 300 mm x 300 mm (width x depth) for full length of drive, water line (2" GI] with 1 inch audco plug valve at an interval of 200m distance, hanger above 3.0 m height to avoid any accidental damage for laying pipes and cables opposite to cross-cut, light fittings of LED bulb of suitable wattage to ensure minimum lux as per the statute at every 6 m interval and manholes as per MMR 1961 and ground support by resin grouted rock bolts of 2.4m long 1.2m grid of 22mm tor steel with 150x150x6 mm bearing plate and 150 mm threaded tightened with nut in rows as per SSR and design approved by the engineer in charge.
Drives/Crosscuts / Draw points: Excavation of extraction drives, crosscuts and draw points of following sizes at different levels including drilling, blasting, muck removal, dewatering at any extent and disposal at surface within a distance of 2.5 km radius from portal/shaft top, ventilation, scaling down of loose rocks, proper drain (kachha Drain) for full length of drive, manholes as per MMR 1961 and ground support by resin grouted rock bolts of 2.4m long 1.2m spacing in a row and 1.2m spacing within two rows of rock bolts of 22mm tor steel with 150x150x6 mm bearing plate and 150 mm threaded tightened with nut as per SSR and design approved by the engineer in charge for 4.5m wide X 4.0m high
Drives/Crosscuts / Draw points: Excavation of extraction drives, crosscuts and draw points of following sizes at different levels including drilling, blasting, muck removal, dewatering at any extent and disposal at surface within a distance of 2.5 km radius from portal/shaft top, ventilation, scaling down of loose rocks, proper drain (kachha Drain) for full length of drive, manholes as per MMR 1961 and ground support by resin grouted rock bolts of 2.4m long 1.2m spacing in a row and 1.2m spacing within two rows of rock bolts of 22mm tor steel with 150x150x6 mm bearing plate and 150 mm threaded tightened with nut as per SSR and design approved by the engineer in charge for 4.2m wide X 4.0m high
Procurement and installation of rigid wire-mesh of 10 cm * 10 cm mesh size of 5-6 mm dia. wire including Fibre reinforced Shotcrete 100 mm thickness (underground) with all material as per SSR and design approved by the engineer in charge.
SMS LIMITED
Maheshwari Mining Pvt. Ltd.
R K TRANSPORT COMPANY
S K KHETAN INFRAPROJECTS PRIVATE LIMITED
ACC MINING PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .