Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC 06 GOVIND NAGAR PANCHAYAT USR TRANSPORT CAMPBELL BAY OLD FISHERMAN COLONY CAMPBELL BAY GREAT NICOBAR ISLANDS | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.4 L+₹1.6 L (10.6%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Not included in category | |
| 4 | Rejected-Technical | - | Rejected-Technical Not included in category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not included in category |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
14 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) CAMPBELL BAY
GE (I) CAMPBELL BAY, ARMY LAND, CAMPBELL BAY, GREAT NICOBAR
COMPREHENSIVE MAINTENANCE AND SERVICING OF STANDBY DIESEL GEN SETS INCLUDING REPLACEMENT OF ITS SPARES AT VARIOUS LOCATIONS OF INS BAAZ, ARMY LAND, CGDHQ-10 AND 3U DET UNDER GE(I) CAMPBELL BAY
2021_MES_489672_1
8783/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
CAMPBELL BAY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) CAMPBELL BAY
₹27,000
Yes
19 Feb 2022
22 Nov 2021
16 Dec 2021
23 Nov 2021
14 Dec 2021
8 Dec 2021
60 days
Amount
Maintenance and servicing, overhauling to DG set including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery tereminals, adding distilled water checking the oil, coolent levels of capacity 63 KVA to 320 KVA DG set installed at various locations complete all as specified and as directed by Engr- in- Charge Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii) Proper record & test results of the same shall be maintained as directed (iv) Work shall be carried out at site at different location Details of Plants :- (a) 320 KVA DG Set -01 No (3U Det Sub-Station) (b) 125 KVA DG Set - 02 Nos (01 No at DHQCG-10 S/S + 01 No INS Baaz S/S) (c) 62.5 KVA DG Set-01 No (d) 50 KVA DG Set-01 No
Supply only the following Items of DG Sets of capacity from 63 KVA to 320 KVA to incorporate against each Item of Schedule 'A' here-in-above (a) Engine oil 20W 40 multi grade of make SERVO/KIRLOSKAR
(b) Diesel filter element with 'O' ring suitable for existing DG set
(c) Spin- on filter element for luricanting oil with 'O' ring suitable for existing DG set
(d) By pass filter element with 'O' ring suitable for existing DG set
(e) Air filter element suitable for existing DG set
(f) Fan Belt complete suitable for capacity existing DG set
Supply and applying Petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make :- Indian oil/ Hindustan Petrolium/ Castrol/ BPCL
Supply and fill distilled water for topping up in lead acid batteries complete all as specified and as directed.
Supply and fill electrolyte of suitable specific gravity for lead acid batteries in sealed container complete all as specified and as directed.
M & L for Battery leads of PVC insulated, multistranded, copper conductor of size 70 sqmm of 1.25 mtr long ach duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations complete including removal of extg unserviceable one complete all as specified and as directed.
M & L for battery teriminal brass clamps including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
S & F for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge. Make:- Exide/ AMCO/ Amaron
M & L for dismantaling the radiator taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for following capacities of DG set complete all as specified and directed
M & L for AVR (automatic voltage regulator) control unit assembly suitable for up to 125 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for AVR (automatic voltage regulator) control unit assembly suitable for up to 125 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for repair and calibration of FIP and injectors from authorised dealer for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for following capacities of DG set complete all as specified and as directed. (a) upto 125 KVA DG set
(b) 125 KVA to 320 KVA DG set
M & L for disconnecting all electrical connections from DG set alternator of capacity upto 320 KVA from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out to work shop for Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing & commissioning complete all as specified and directed. Note:- (i) Transporting alternator to workshop at Port Blair and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed is deemed to be inclusive in quoted rates.
M & L for Repair/ overhauling of self starting system of DG set including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
S & F for Time delay relay suitable for 100.00 KVA DG set to 380.00 KVA DG set including removal of extg unserviceable one compete all as specified and as directed. Make:- Simens/ L&T/ ABB/ C & S
M & L for solinoid switch assembly 24 volts suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for DC alternator assembly 24 volts suitable for 100 KVA DG set to 380 KVA DG set including removal of extg unserviceable one compete all as specified and as directed by Engr-in charge.
M & L for chart/ diagram/ name plates/ details of DG sets made out of bakeite hylem sheet, ISI marked, 3 mm thick , cutting to shape /size including fixing of adhesive transperent filament of red/ blue colour including cutting of filament of letters/ figures/ diagrames/ details of suitable size/ type all as directed inclluding fixing to the wall by wooden screw and PVC hold fast etc complete all as directed and specified. Note :- Matter/ figure/ chart/ diagrames/ letter shall be give by the Engineer- in- Charge
Supply and fill genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and as directed.
M & L for self starter assembly 12 volts complete suitable for 320 KVA DG setincluding removal of extg unserviceable one complete all as specified and as directed. Make:- Lucas/ TVS
M & L DG set of capacity 125 KVA testing, including disassembling alternator from gen set,opening of acoustic enclosure,shifting to a suitable place reassembling,overhauling complete &testing ,connecting of earthing & LT panel with suitable size of lugs as directed by Engineer - in - Charge DG set including removal of extg unserviceable one compete all as specified .
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip of 32x6mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 5 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel 15mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
Ashini Sikder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .