| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.2 LAccepted-AOC | ₹96.2 L | L1 | Accepted-AOC Responsive |
| 2 | L2₹1.0 Cr+₹4.0 L (4.20%)Rejected-Finance | ₹1.0 Cr+₹4.0 L (4.20%) | L2 | Rejected-Finance Not Responsive |
| 3 | L3₹1.0 Cr+₹4.1 L (4.27%)Rejected-Finance | ₹1.0 Cr+₹4.1 L (4.27%) | L3 | Rejected-Finance Not Responsive |
| 4 | L4₹1.2 Cr+₹20.1 L (20.9%)Rejected-Finance | ₹1.2 Cr+₹20.1 L (20.9%) | L4 | Rejected-Finance Not Responsive |
| 5 | L5₹1.3 Cr+₹29.4 L (30.6%)Rejected-Finance | ₹1.3 Cr+₹29.4 L (30.6%) | L5 | Rejected-Finance Not Responsive |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
5 Apr 2022, 1:00 pmClosed
Executive Engineer
O/o Executive Engineer, Naharlagun PWD, AP, Naharlagun
C/o. Road, Drainage and Retaining wall from Forest Nursery to Tela Basti,C-sector, Naharlagun
2022_PWDAP_712_1
ND/ 2021-22/13
Open Tender
Civil Works
Item Rate
90 days
Naharlagun
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3.0 L
Yes
Naharlagun
24 Apr 2022
31 Mar 2022
5 Apr 2022
31 Mar 2022
5 Apr 2022
31 Mar 2022
1 Apr 2022
Amount
SH:- RCC RETAINING WALL-6mtr Height
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M20/ Using Concrete Mixer
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification (A) Granular material
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications
SH:- CC Drain
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.) I Ordinary soil A Manual Means (i) upto 3 m depth
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specificationsPCC Grade M20
SH:- Storm Water Drain
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.) I Ordinary soil A Manual Means (i) upto 3 m depth
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specificationsPCC Grade M20
RCC (M20) 1:1.5:3 ( 1 Cement ,1.5 Coarse Sand, 3: Stone Agregare 20mm nominal size) Using concrete mixer.
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications
SH:- CC Pavement Road
Preparation of Sub Grade:) Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 )
125 Micron Polythene ( Providing and fixing 125 micro polythene over sub base)
Cable Duct Across the Road (Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.) i)Single Row for Single utility services
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )
M/s Raj Steel
M/s City Tec Solutions
M/S MATE ENTERPRISES
M/. PUMIN ENTERPRISES
M/s T P Enterprises
M/S N.K. Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_793.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .