| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC MAHALDANGA P O MOLIAN DIST BANKURA PIN 722136 | BANKURA | BANKURA | WEST BENGAL | 722136 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹2.0 L+₹3,158 (1.64%)Rejected-Finance BANSHBARI MALDA | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹2.0 L+₹5,648 (2.93%)Rejected-Finance 334 SCHOOLDANGA BANKURA BANKURA PIN 722101 WEST BENGAL | BANKURA | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹3,862
Closing Date
19 Jul 2024, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/BESD-I
OFFICE OF THE ASSISTANT ENGINEER Bankura Electrical Sub-Division-I, PWDte Kenduadihi PWD campus near Bhairabsthan Bankura-722102
Electrical Repairing work of Security light for Quarter Campus, besides Inspection Bungalow, PWD, in the District of Bankura.
2024_WBPWD_711949_1
WBPWDTE/AE/BESD-I/e-NIQ 02 of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Quarter Campus, besides Inspection Bungalow
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,862
Yes
29 Apr 2025
11 Jul 2024
22 Jul 2024
11 Jul 2024
19 Jul 2024
11 Jul 2024
Amount
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm / 25mm prelaid polythene pipe/PVC rigid conduit as per GS. Make - RR KABEL / Havells / KEI/Polycab or as per direction of EIC. 3 x (1.5 sqmm) [1(b) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires. a)1.5 sq mm
Supplying and fixing 415 V 25A 3P Modular Contactor on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ L&T) as per direction of EIC. NS
Supplying and fixing 415 V 16A Alalog Time Switch on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ L&T) as per direction of EIC. NS
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legran d/ L&T/ABB/ Siemens) as per direction of EIC. ] as per direction of EIC. ] 32 FP [ 7 / D- 6]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 Way [ 7 / D- 6]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Gloster/RR KABEL/Havells or as per direction of EIC] 4 Core 6 Sqmm [ NS ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [1(a)/F-2]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as per GS. 4 Core 6 Sqmm [7(c)/F4]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials as per GS. 4 Core 6 Sqmm [8(b)/F5]
Supply & Fixing of 240V LED Street light luminarie (Phillips-Cat no.BRPO62 LED 84 CW SLC S1 PSU or equivalent make of CG/Havells) as per direction of E.I.C [NS] including 10KV SPD.
Supply and fixing 14W LED bulb (/CG/Philips/ /Havells) on existing batten holder [NS]
Supply & Fixing of PVC Water proof type loop box (make : Sintex ) of size 8"x10" comprising of 4 way 100A Capacity brass stud/ terminals make AC/DC and having hinged type PVC top cover & 4mm Thick rubber gasket lining , railway type mechnical door locking arrangement, comprising of one 250V 15A Kitkat fuse unit, one NL on porcelain insulator etc. conceal in wall as per direction of EIC.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 40 mm dia [ 11(c)/F-6]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No.-4 SWG [5(a)(i)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [4(A)/G-2]
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. (i) 1st coat of aluminium paint over 1 coat of RO priming [4(a)(i)/H-2]
(ii) 2nd coat of aluminium paint over 1st coat [4(a)(i)/H-2]
M/S KUNDU CONSTRUCTION
Swarnendu Sarkar
technical_1561376.pdf
PDF • 0.43 MB
techsummary_1561376.pdf
PDF • 0.33 MB
finance_1561376.pdf
PDF • 0.33 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1561376.pdf
PDF • 0.43 MB
2024_WBPWD_711949_1.pdf
PDF • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .