Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹1.5 L (0.88%)Admitted-Finance D 2002 ORCHID SUBURBIA OFF NEW LINK ROAD KANDIVALI WEST MUMBAI MAHARASHTRA 400067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.7 Cr+₹1.5 L (0.88%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not Qualified |
| Sl No | Description | Qty | Unit | Enterprising Enterprise L1 | Lion Rubber Industries Pvt. Ltd. L2 |
|---|---|---|---|---|---|
| 1.00 | Fabrication, Supply and Installation of M.S. Frontal Frame of size 4900 mm x 2280 mm X355 mm suitable for 1450 H Cell Fender. Frame to be of Open type with steel to be as per IS:2062 and welding as per relevant AWS/IS standard, all the welding to be done by IRS/AWS qualified welders only, welding to be GMAW/MIG welding only-SMAW/stick welding will not be allowed. NDT Test like DP, MPI or Radiography to be carried out on all welding percentage basis, all the work to be under third party inspection of IRS. For all steel to be of SAIL, TATA, JINDAL, ESSAR make only and manufacturer's Test Certificate to be provided before starting the fabrication and if require sample will be sent for testing in NABL approved testing laboratory. The total frontal frame after fabrication should have blast cleared to SA 2 1/2 (Swedish Standard) or SSPC 10 and coated with the first coat of Zinc rich Primer min. 100 microns, top coat Coal tar epoxy of min. 150 microns, Total dry film thickness of minimum of 450 microns & all the fabrication to be done as per IS: 800 and other relevant standards. The line, straightness and level to be perfect and to be within tolerance of +/- 2 mm. The welding of S.S. Nuts with m.s. frontal frame to be done with correct welding electrode like E- 309 L or equivalent grade. The total fabrication/ supply work to be under third party inspection and certificate to be provided after supply of frontal frame. The work also includes removal of old frontal frame and installation of new frontal frame with required capacity crane at jetty with all accessories etc. Frame installation to be carried out as per berthing schedule of JNPT and tide suitability. Work may have to be carried out in night shift and on round the clock basis. Old Frontal Frame along with chains/accessories to be shifted to designated location within JNPT as directed by EIC. NOTE- Lifting points shall be provided on the both side top portion of frame to permit easy mounting. | 112 | Sqm | - | - |
| 2.00 | Fabrication, Supply and Installation of M.S. Frontal Frame of size 5300 mm x 1500 mm x355mm suitable for 1050 H Cone Fender with proper mounting arrangement with cone fender. Frame to be of Open type with steel to be as per IS:2062 and welding as per relevant AWS/IS standard, all the welding to be done by IRS/AWS qualified welders only, welding to be GMAW/MIG welding only-SMAW/stick welding will not be allowed. NDT Test like DP, MPI or Radiography to be carried out on all welding percentage basis, all the work to be under third party inspection of IRS. For all steel to be of SAIL, TATA, JINDAL, ESSAR make only and manufacturer's Test Certificate to be provided before starting the fabrication and if require sample will be sent for testing in NABL approved testing laboratory. The total frontal frame after fabrication should have blast cleared to SA 2 1/2 (Swedish Standard) or SSPC 10 and coated with the first coat of Zinc rich Primer min. 100 microns, top coat Coal tar epoxy of min. 150 microns, Total dry film thickness of minimum of 450 microns & all the fabrication to be done as per IS: 800 and other relevant standards. The line, straightness and level to be perfect and to be within tolerance of +/- 2 mm. The welding of S.S. Nuts with m.s. frontal frame to be done with correct welding electrode like E- 309 L or equivalent grade. The total fabrication/supply work to be under third party inspection and certificate to be provided after supply of frontal frame. The work also includes removal of old frontal frame and installation of new frontal frame with required capacity crane at jetty with all accessories etc. Frame installation to be carried out as per berthing schedule of JNPT and tide suitability. Work may have to be carried out in night shift and on round the clock basis. Old Frontal Frame along with chains/accessories to be shifted to designated location within JNPT as directed by EIC. NOTE- Lifting points shall be provided on the both side top portion of frame to permit easy mounting | 16 | Sqm | - | - |
| 3.00 | Supplying and fixing of UHMW-PE PAD -30mm Thk. (Black Colour) - 2 mtr X 1/2 Mtr. including S.S. AISI 304 bolts with nut and heavy duty washer. | 133 | Sqm. | - | - |
| 4.00Supplying and fixing S.S. AISi 304 bolts with bend heavy duty washer .The work also includes removing old damaged bolts assembly at site on the cell fenders with the frontal frame of the fenders ASSY including necessary flat forms etc. at site including crane if required for lifting the fender assembly. The fender assembly with all tools and tackles. The bolts with washer should be matching to existing types matching with existing sleeve on walls. M38 x 150 (FULL THREAD) ASSY. | |||||
| 4.10 | i) M-48 | 120 | Nos. | - | - |
| 4.20 | ii) M-36 | 12 | Nos. | - | - |
| 4.30 | iii) M-30 | 12 | Nos. | - | - |
| 5.00Supplying and fixing M.S. hot dip galvanized link chain on site for the cell fender assembly and coating thickness of galvanizing should be minimum 90 microns as per relevant IS Code and MANF.T.C. to be submitted. The work also includes removing old damaged / corroded chain by gas cutting and hand over old materials to JNPT, including all tools, tackles, platforms and crane if required at JNPT Jetty. | |||||
| 5.10 | a) 32mm chain | 116 | Rmt. | - | - |
| 5.20 | b) 50mm chain | 39 | Rmt. | - | - |
Tender Value
₹1.7 Cr
EMD Value
₹4.0 L
Closing Date
4 Jan 2020, 3:00 pmClosed
CM PPD
Jawaharlal Nehru Port Trust Administration Building, Sheva, Navi Mumbai
Replacement of Old Frontal Frames and Accessories at Main Container Berth, JNPT
2019_JNPT_524691_1
PPD/ M-II / Frontal Frame/ T-56 /2019
Open Tender
Civil Works
Works
180 days
JAWAHARLAL NEHRU PORT TRUST
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,800
JAWAHARLAL NEHRU PORT TRUST
₹4.0 L
Yes
13 Apr 2020
5 Dec 2019
6 Jan 2020
5 Dec 2019
4 Jan 2020
5 Dec 2019
Amount
Fabrication, Supply and Installation of M.S. Frontal Frame of size 4900 mm x 2280 mm X355 mm suitable for 1450 H Cell Fender. Frame to be of Open type with steel to be as per IS:2062 and welding as per relevant AWS/IS standard, all the welding to be done by IRS/AWS qualified welders only, welding to be GMAW/MIG welding only-SMAW/stick welding will not be allowed. NDT Test like DP, MPI or Radiography to be carried out on all welding percentage basis, all the work to be under third party inspection of IRS. For all steel to be of SAIL, TATA, JINDAL, ESSAR make only and manufacturer's Test Certificate to be provided before starting the fabrication and if require sample will be sent for testing in NABL approved testing laboratory. The total frontal frame after fabrication should have blast cleared to SA 2 1/2 (Swedish Standard) or SSPC 10 and coated with the first coat of Zinc rich Primer min. 100 microns, top coat Coal tar epoxy of min. 150 microns, Total dry film thickness of minimum of 450 microns & all the fabrication to be done as per IS: 800 and other relevant standards. The line, straightness and level to be perfect and to be within tolerance of +/- 2 mm. The welding of S.S. Nuts with m.s. frontal frame to be done with correct welding electrode like E- 309 L or equivalent grade. The total fabrication/ supply work to be under third party inspection and certificate to be provided after supply of frontal frame. The work also includes removal of old frontal frame and installation of new frontal frame with required capacity crane at jetty with all accessories etc. Frame installation to be carried out as per berthing schedule of JNPT and tide suitability. Work may have to be carried out in night shift and on round the clock basis. Old Frontal Frame along with chains/accessories to be shifted to designated location within JNPT as directed by EIC. NOTE- Lifting points shall be provided on the both side top portion of frame to permit easy mounting.
Fabrication, Supply and Installation of M.S. Frontal Frame of size 5300 mm x 1500 mm x355mm suitable for 1050 H Cone Fender with proper mounting arrangement with cone fender. Frame to be of Open type with steel to be as per IS:2062 and welding as per relevant AWS/IS standard, all the welding to be done by IRS/AWS qualified welders only, welding to be GMAW/MIG welding only-SMAW/stick welding will not be allowed. NDT Test like DP, MPI or Radiography to be carried out on all welding percentage basis, all the work to be under third party inspection of IRS. For all steel to be of SAIL, TATA, JINDAL, ESSAR make only and manufacturer's Test Certificate to be provided before starting the fabrication and if require sample will be sent for testing in NABL approved testing laboratory. The total frontal frame after fabrication should have blast cleared to SA 2 1/2 (Swedish Standard) or SSPC 10 and coated with the first coat of Zinc rich Primer min. 100 microns, top coat Coal tar epoxy of min. 150 microns, Total dry film thickness of minimum of 450 microns & all the fabrication to be done as per IS: 800 and other relevant standards. The line, straightness and level to be perfect and to be within tolerance of +/- 2 mm. The welding of S.S. Nuts with m.s. frontal frame to be done with correct welding electrode like E- 309 L or equivalent grade. The total fabrication/supply work to be under third party inspection and certificate to be provided after supply of frontal frame. The work also includes removal of old frontal frame and installation of new frontal frame with required capacity crane at jetty with all accessories etc. Frame installation to be carried out as per berthing schedule of JNPT and tide suitability. Work may have to be carried out in night shift and on round the clock basis. Old Frontal Frame along with chains/accessories to be shifted to designated location within JNPT as directed by EIC. NOTE- Lifting points shall be provided on the both side top portion of frame to permit easy mounting
Supplying and fixing of UHMW-PE PAD -30mm Thk. (Black Colour) - 2 mtr X 1/2 Mtr. including S.S. AISI 304 bolts with nut and heavy duty washer.
Supplying and fixing S.S. AISi 304 bolts with bend heavy duty washer .The work also includes removing old damaged bolts assembly at site on the cell fenders with the frontal frame of the fenders ASSY including necessary flat forms etc. at site including crane if required for lifting the fender assembly. The fender assembly with all tools and tackles. The bolts with washer should be matching to existing types matching with existing sleeve on walls. M38 x 150 (FULL THREAD) ASSY.
Supplying and fixing M.S. hot dip galvanized link chain on site for the cell fender assembly and coating thickness of galvanizing should be minimum 90 microns as per relevant IS Code and MANF.T.C. to be submitted. The work also includes removing old damaged / corroded chain by gas cutting and hand over old materials to JNPT, including all tools, tackles, platforms and crane if required at JNPT Jetty.
a) 32mm chain
b) 50mm chain
Supplying and fixing M.S. hot dip galvanized "D" shackles/tensioner on site for the chain to frontal frame assembly and coating thickness of galvanizing should be minimum 90 microns as per relevant IS Code. The work also includes removing old damaged / corroded "D" shackles by gas cutting and hand over old materials to JNPT including all tools, tackles, platforms and crane if required at JNPT jetty
a) 32mm d shackle & tensioner
b) 50mm d shackle & tensioner
Lion Rubber Industries Pvt. Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
1050_Cone_Fender.pdf
Additional Documents • 0.12 MB
1450_Cell_Fender.pdf
Additional Documents • 0.12 MB
BOQ_549338.xls
BOQ • 0.29 MB
Drawing.pdf
Additional Documents • 0.10 MB
Tender_for_FF.pdf
Tender Documents • 1.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .