Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.0 L+₹1.3 L (5.44%)Rejected-Finance | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹26.8 L+₹2.2 L (9.02%)Rejected-Finance D 35 NEAR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹26.9 L+₹2.2 L (9.10%)Rejected-Finance D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L4 | Rejected-Finance Other than L1 bidder | |
| 5 | L5₹27.4 L+₹2.7 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 bidder |
| Sl No | Description | Qty | Unit | m/s rudraksh enterprises L3 | M/S SHARADA ASOCIATE L1 | Balaji Associates L2 | Shiva Enterprises L7 | M/s Navansh Engineers & Consultants L4 | M/S VIDIT ENTERPRISES L8 | S N AGARWAL L6 | Mani Control System L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 32x6 mm as earthin lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. | 20 | Each Job | 5,000 ₹1,00,000 | 4,000 ₹80,000 | 4,000 ₹80,000 | 5,000 ₹1,00,000 | 4,500 ₹90,000 | 2,500 ₹50,000 Lowest | 5,000 ₹1,00,000 | 5,000 ₹1,00,000 |
| 2.00 | S&F in replacement of board of size 2m x 1.5m, made up with 1.2 mm thick acrylic sheet, with of approved specification as per MORTH. The layout plan of sub sation from 33kv or 11 KV panel to all feeders in the substation. complete all as specified and directed.
Note- The drawing of board shall be approved by Engr-in-Charge. | 4 | Each | 85,000 ₹3,40,000 | 15,000 ₹60,000 | 7,000 ₹28,000 Lowest | 12,000 ₹48,000 | 87,000 ₹3,48,000 | 15,000 ₹60,000 | 25,000 ₹1,00,000 | 65,000 ₹2,60,000 |
| 3.00 | Surface dressing in soft/loose soil not exceeding 15 cm deep and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr and spray of herbicide chemical to stop the growth of grass and bushings complete all as specified and directed. | 4,500 | Sqm | 10 ₹45,000 | 15 ₹67,500 | 8 ₹36,000 | 20 ₹90,000 | 10 ₹45,000 | 10 ₹45,000 | 5 ₹22,500 Lowest | 15 ₹67,500 |
| 4.00 | M & L for trimming/cutting/chopping of tree branches all around LT/HT over conductor upto two meter and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr complete all as specified and directed. Note-(i) The deemed rate shall includes all T & P required for tree branch cutting. | 250 | Each Span | 150 ₹37,500 | 250 ₹62,500 | 100 ₹25,000 Lowest | 200 ₹50,000 | 150 ₹37,500 | 100 ₹25,000 Lowest | 150 ₹37,500 | 200 ₹50,000 |
| 5.00 | Supply, installation, commissioning and testing in replacement of air break switch gang operated HT 11 KV triple pole outdoor type with 12 insulator 200 Amps rating with drop out fuse assly with fuse carrier and the fuse element mounted on insulator and steel frame mechanically operated with operating mechanism consisting of operating rod of 25mm bore light grade GI pipe of suitable length operative from ground level and with locking arrangement with MS flat iron clamp 50 x 6 mm including MS channel of suitable size and length to fixing GOD including nuts, bolts and washers all as specified and directed. | 10 | Each set | 20,000 ₹2,00,000 | 7,000 ₹70,000 Lowest | 9,000 ₹90,000 | 10,000 ₹1,00,000 | 19,999 ₹1,99,990 | 10,500 ₹1,05,000 | 20,000 ₹2,00,000 | 18,000 ₹1,80,000 |
| 6.00 | M & L in repair for chain link fencing of 2.10 m height for providing boundary to HT busbar/ panels/Transformers etc and connected accessories with chain link MS galvanised fencing with 4 mm dia GI wire mattresses with mesh of size 50x50 mm including excavation in post hole, PCC work in 1:3:6 angle iron of size 50x 50x6 mm duly placed at a gap of 2m. The chain link fencing shall be supported with three numbers round bar of 12 mm equally spaced at spacing and supported on MS flat with angle iron duly tightened with nuts, bolts and washers. The fencing shall be provided with one iron gate of size 2.10 m high and 0.90 m wide made up of angle iron frame of size 50x50x6 mm and square bars. The gate shall be provided with hasp and staple made up of iron frame for locking the area complete. The corner support with 50x50x6mm MS angle iron support including fixing of chain link using 40x6 mm flat iron on all sides with nuts, bolts & washers, painting with two coats of synthetic enamel paint over a coat of primer for all surfaces gate complete all as specified and directed. | 60 | Sqm | 3,250 ₹1,95,000 | 1,500 ₹90,000 | 1,200 ₹72,000 | 3,000 ₹1,80,000 | 3,300 ₹1,98,000 | 450 ₹27,000 Lowest | 1,000 ₹60,000 | 700 ₹42,000 |
| 7.00 | S & F in repairs 11 KV Lightning Arrester of discharge capacity of 10 KA peak, transmission class 2, complete all as specified and as directed. | 8 | Set of three | 4,500 ₹36,000 | 12,000 ₹96,000 | 20,000 ₹1,60,000 | 25,000 ₹2,00,000 | 4,200 ₹33,600 | 2,500 ₹20,000 | 20,000 ₹1,60,000 | 1,500 ₹12,000 Lowest |
| 8.00 | Supply and jointing in repair of heat shrinkable end termination outdoor joint with jointing material suitable for HT 11KV XLPE cable of size 95 to 120 Sq mm 3 core complete all as specified and as directed. | 10 | Each | 5,000 ₹50,000 | 4,000 ₹40,000 Lowest | 5,500 ₹55,000 | 5,000 ₹50,000 | 4,998 ₹49,980 | 4,500 ₹45,000 | 5,500 ₹55,000 | 4,200 ₹42,000 |
| 9.00 | Supply and jointing in repair of heat shrinkable end termination indoor joint with jointing material suitable for HT 11KV XLPE cable of size 95 to 120 Sq mm 3 core complete all as specified and as directed. | 6 | Each | 5,000 ₹30,000 | 3,000 ₹18,000 Lowest | 5,000 ₹30,000 | 4,000 ₹24,000 | 4,998 ₹29,988 | 4,500 ₹27,000 | 5,000 ₹30,000 | 3,500 ₹21,000 |
| 10.00 | Supply and jointing in repair of straight through heat shrink type joint complete with jointing material suitable for cable size 120 to 185 Sq mm complete all as specified and directed. | 4 | Each | 6,000 ₹24,000 | 9,000 ₹36,000 | 13,500 ₹54,000 | 10,000 ₹40,000 | 5,800 ₹23,200 | 12,500 ₹50,000 | 8,500 ₹34,000 | 4,200 ₹16,800 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Nov 2025, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
REPAIR/ MAINT OF OUTDOOR SUB STN,FOUR POLE STRUCTURE, PATH, FENCING, GATE, GRAVELLS,PAINTING AND ALLIED WORKS AT WEST SIDE AREA UNDER GE (E) AGRA
2025_MES_738539_1
9812/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Agra Cantt
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹80,000
Yes
12 Jan 2026
6 Nov 2025
4 Dec 2025
6 Nov 2025
27 Nov 2025
20 Nov 2025
Amount
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 32x6 mm as earthin lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.
S&F in replacement of board of size 2m x 1.5m, made up with 1.2 mm thick acrylic sheet, with of approved specification as per MORTH. The layout plan of sub sation from 33kv or 11 KV panel to all feeders in the substation. complete all as specified and directed. Note- The drawing of board shall be approved by Engr-in-Charge.
Surface dressing in soft/loose soil not exceeding 15 cm deep and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr and spray of herbicide chemical to stop the growth of grass and bushings complete all as specified and directed.
M & L for trimming/cutting/chopping of tree branches all around LT/HT over conductor upto two meter and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr complete all as specified and directed. Note-(i) The deemed rate shall includes all T & P required for tree branch cutting.
Supply, installation, commissioning and testing in replacement of air break switch gang operated HT 11 KV triple pole outdoor type with 12 insulator 200 Amps rating with drop out fuse assly with fuse carrier and the fuse element mounted on insulator and steel frame mechanically operated with operating mechanism consisting of operating rod of 25mm bore light grade GI pipe of suitable length operative from ground level and with locking arrangement with MS flat iron clamp 50 x 6 mm including MS channel of suitable size and length to fixing GOD including nuts, bolts and washers all as specified and directed.
M & L in repair for chain link fencing of 2.10 m height for providing boundary to HT busbar/ panels/Transformers etc and connected accessories with chain link MS galvanised fencing with 4 mm dia GI wire mattresses with mesh of size 50x50 mm including excavation in post hole, PCC work in 1:3:6 angle iron of size 50x 50x6 mm duly placed at a gap of 2m. The chain link fencing shall be supported with three numbers round bar of 12 mm equally spaced at spacing and supported on MS flat with angle iron duly tightened with nuts, bolts and washers. The fencing shall be provided with one iron gate of size 2.10 m high and 0.90 m wide made up of angle iron frame of size 50x50x6 mm and square bars. The gate shall be provided with hasp and staple made up of iron frame for locking the area complete. The corner support with 50x50x6mm MS angle iron support including fixing of chain link using 40x6 mm flat iron on all sides with nuts, bolts & washers, painting with two coats of synthetic enamel paint over a coat of primer for all surfaces gate complete all as specified and directed.
S & F in repairs 11 KV Lightning Arrester of discharge capacity of 10 KA peak, transmission class 2, complete all as specified and as directed.
Supply and jointing in repair of heat shrinkable end termination outdoor joint with jointing material suitable for HT 11KV XLPE cable of size 95 to 120 Sq mm 3 core complete all as specified and as directed.
Supply and jointing in repair of heat shrinkable end termination indoor joint with jointing material suitable for HT 11KV XLPE cable of size 95 to 120 Sq mm 3 core complete all as specified and as directed.
Supply and jointing in repair of straight through heat shrink type joint complete with jointing material suitable for cable size 120 to 185 Sq mm complete all as specified and directed.
All as per item No 09 here in before but suitable for cable size 95 Sq mm complete all as specified and directed.
M & L for disconnecting the transformer connection from both side and lift from the existing foundation and re- connect at same location or other location after foundation repair complete all as specified and directed. Note- (i) All T & P used for lifting and relocating the transformer shall be deemed in quoted rates.
Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided , etc complete all as specified and directed.
M&L for cement concrete (1:3:6) type C2 using 40 mm gradded stone aggregate for Cement concrete in foundations , filling and mass concrete etc complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board etc complete all as specified and as directed.
M&L for brick work with sub class B bricks straight or curved on plan 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class B bricks straight or curved on plan 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of cement plaster 1:6 complete all as specified and as directed.
Supply and fixing cable route indicator made out of pcc 1:2:4 of size length 30 cm , width/thickness- 15 cm and Height -100cm reinforeced with 8 mm dia at 8 cms centre to centre on LT cable 1 mtr depth grouted in the ground with suitable PCC work with writing MES HT cable joint complete all as directed.
Dehydration and Filtration of existing transformer oil in transformers (33 KV system step down to 33/11 KV and 11 KV system step down to 11/0.433 KV) by centrifuging machine on site at different locations without disturbing the power supply system. The machine continuously run round the clock till obtaining the dielectric strength of oil 60 KV minimum 2.5 mm gap and carrying out IR test of primary and secondary of transformer including commissioning and testing of transformers after topping up with new transformer oil complete all as specified and directed. Note:- New Transformer oil for topping up shall be measured in relevant items of Sch "A".
Supply, heating and filling/topping up/replacement of transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity in transformer confirming to IS-335 of 1983 complete all as specified and directed.
S&F in repair acrylic sign board of size 2.00m x 0.75m x 0.3m fabricated with frame 25mmx25mmx3mm with front side acrylic signing sheet thickness of sheet 4mm with written letter and symbol, made out of 3mm thick film pasted from inside with required coluring and other side of board providing with sheet including inside providing LED light 20W 2feet long 2numbers with 2.5 sqmm PVC insulated copper wire 4 m long complete with fixing arrangment on wall/roof complete all as specified and directed.
M & L for fault detection through machine to detect and rectify underground HT cable fault including disconnecting the cable and rectify the fault including necessery earth work and reconnected to the existing postion complete all as specified and directed. Notes : (i) All T&P and other acceseries required for checking and finding of fault in cable shall be provided by the Contractor. (ii) Charges/rent of the fault locating mobile machine, operator, engineer, electricians etc shall be deemed to included rate quoted by Contractor.
Supply and fixing in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed.
Taking out trolley of VCB 630/800 Amps 11 KV from the cabinet and opening top cover, de-carbonizing moving and fixed contacts if required, lubricating, inspecting the wiring of Micro processor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system complete including servicing and callibration of microproccessor E/F and O/C relay of VCB with primary and secondary injection complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with main grid for proper functioning and placing back the breaker trolley in its original position all as specified and as directed. Note: (i) The various unsv items required to be replaced shall be paid seperately
Supply only of closing coil assembly 230 volts AC/ 24 volts DC, all as specified and directed by Engineer-in-Charge.
Supply only of Tripping coil with plunger assembly 230 volts AC/24V DC, all as specified and directed by Engineer-in-Charge.
Supply only of spout bushing 11 KV for VCB all as specified and directed by Engineer-in-Charge.
Supply and fix in replacment of Vaccum interruptor type WL-33379 (4 inch dia) suitable for HT VCB 630 Amps as per existing all as specified and directed.
S & F in replacement trip push button suitable for HT 11 KV VCB complete all as specified and directed.
S & F in replacement of indicator lamp LED with holder (R/Y/B in colour) complete all as specified and as directed.
S & F in replacement of CT operated digital ampere meter 0 to 200 Amps flush pattern square type suitable to mounted on existing HT panel complete all as specified & directed.
S & F in replacement Over current & earth fault relay CG14N/recommended by Eng-in-charge complete all as specified and directed.
S & F in replacement Auxiliary relay type VAA complete all as specified and directed.
S & F in replacement trip circuit supervision relay type VAX MKII complete all as specified and directed.
S & F in replacement tripping relay type VAZ complete all as specified and directed.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Material and labour for replacement of worn out breather with silica gel all as per existing sample suitable for transformers of capacity 100 to 500 KVA. Make: Jaypuri Brother /Pactil all as specified and directed.
Preparation of old surface of fencing for painting externally including removal of all rust and unwanted material and painting with one coat of superior quality aluminum paint on exposed surface all as specified and directed.
Removing of old paint by removers scrubing from HT steel poles 11 mtr, cross arms clamps etc for painting and M &L for painting with one coat of superior quality aluminum paint on exposed surface of poles including clamps and cross arms mounted on the poles and MS sections as under making black strip upto1.5 Mtr height from ground level and writing pole Nos etc. written on it with black synthetic enamel paint compete all as specified and directed.
Preparation of old surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel paint by means of spray gun at site of installation of transformer including writing SM No. & Cap of transformer complete all as specified and directed by Engineer- in- Charge suitable for transformers of capacity 100 to 400 KVA all as specified and directed.
S & F in replacement battery 130 Ah, 12 volt complete all as specified and directed.
Supply and installation of ESE lightning arrester rakshak ESE LA model R-60(maximum radius covered by LA will be 107 mtr), upto 10 meter GI mast, ESE LA counter of strikes, test link Box (MS powder coated box size of L 300mm x W120 mm x b100 mm), guy rope and accessories for support to a mast protect from wind flow complete all as specified and directed by Eng- in- Charge. The following items are also included in quoted rates- (a) 70sqmm single core copper flexible cable -20mtr (b) GI 76x3 mtr pipe in pipe chemical earthing ealectrode with each electrode 25 Kg, 2 chemical specified by manufacturer - 02 nos
M&L for gravel, hard and preferably with specific gravity not less than 1.6,free from clay,sand,loam and organic impurities of any kind,acid solubility not more than 10% for gravel size 10 mm or larger and 5 % solubility for gravel size smaller than 10 mm,particle size 20mm-30 mm complete all as specified and directed.
Supply and fixing HDPE liner sheet heavy duty black colour,min thickness 250 micron including jointing and 10 cm over lap material complete all as specified.
Balaji Associates (BID ID -3483856)
m/s rudraksh enterprises (BID ID -3482972)
M/s Navansh Engineers & Consultants (BID ID -3487034)
Mani Control System (BID ID -3482902)
S N AGARWAL (BID ID -3483701)
Shiva Enterprises (BID ID -3484182)
M/S VIDIT ENTERPRISES (BID ID -3484277)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_826955.xls
BOQ • 0.31 MB
9812Tenderdocuments.pdf
Tender Documents • 0.83 MB
9812PS.pdf
Additional Documents • 0.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .