| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.1 LAccepted-AOC | ₹62.1 L Quoted ₹63.4 L | L1 | Accepted-AOC L1 accepted |
| 2 | L2₹64.4 LRejected-Finance | ₹64.4 L | L2 | Rejected-Finance L2 Rejected |
| Sl No | Description | Qty | Unit | Hindustan Engineers & Contractors L1 | T LOBI DHAS L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead | 40 | Sqm | 280 ₹11,200 | 290 ₹11,600 |
| 2.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 6.93 | Cum | 3,731 ₹25,855.83 | 3,800 ₹26,334 |
| 3.00 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge - In cement mortar | 0.6 | Cum | 2,164 ₹1,298.40 | 2,300 ₹1,380 |
| 4.00 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. | 47 | Sqm | 138 ₹6,486 | 150 ₹7,050 |
| 5.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kind of soil | 6 | Cum | 187 ₹1,122 | 190 ₹1,140 |
| 6.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 1.5 | Cum | 2,232 ₹3,348 | 2,200 ₹3,300 |
| 7.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 3 | cum | 206 ₹618 | 202 ₹606 |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) | 5.5 | Cum | 6,848 ₹37,664 | 6,800 ₹37,400 |
| 9.00Centering and shuttering including strutting, propping etc. and removal of form for | |||||
| 9.01 | Foundations, footings, bases of columns, etc. for mass concrete | 8 | Sqm | 412 ₹3,296 | 405 ₹3,240 |
Tender Value
Refer Docs
EMD Value
₹41,100
Closing Date
8 Oct 2025, 3:00 pmClosed
Superintending Engineer PWD
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle 2, Chepauk Chennai 5
Installation of Thiruvalluvar Statue on behalf of Government of Tamil Nadu, near Convention Centre in Jawaharlal Nehru University New Delhi
2025_PWD_611191_1
TNPWD/25-3 BCM/2025-26
Open Tender
Civil Works
New Delhi
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹41,100
14 Mar 2026
4 Oct 2025
8 Oct 2025
4 Oct 2025
8 Oct 2025
4 Oct 2025
Amount
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge - In cement mortar
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kind of soil
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (Any Thickness
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Hot rolled deformed bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red ;Area of slab over 0.50 sqm
Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. For Granite
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Designing, making, supplying and erection of Full size Bronze Statue and Athara peedam for Ayyan Thiruvalluvar Statue made of Bronze metal ie., alloy of copper, Lead, Tin, Zinc Traditional Mixture suitable for making bronze sculpture size proportinate for 1.90 meters height statue and 0.45 meters height of peedam in proportion for the total tentative weight of around 1000 kg as per the Approved photo or miniature . The making process includs the Scale mesurement drawing & sculpting armature making, clay modeling, mould in POP, Model tranfering to wax, making sand mould (wax-core), De-waxing & bronze casting of model, grinding, welding, chiseling, finishing with PU gold coating et Complete complying with standard specifications.
The rate shall be inclusive of Transporting charges of the finished bronze statue from studio to the erecting site, Scaffolding and crane required for the erection etc complete and inclusive of GST @ 12%
Engraving and fixing in position granite name board of size 0.60m x 0.75m by engraving letters in and state emblem and painting the same with superior quanlity golden colour and given necessary borders and fixing the name board in slanding position including set in cement mortar 1:3 and fixing properly in ture alignment etc. complete.
Supply and Laying of 4 x 10 sqmm PVC armared LTUG Cable in 63mm diameter PVC pipe of 4 kg/cm in a trench to be excavated at suitable depth putting 0.15mt layer of sand covering cable and pipe with sand and re-filling the earth make good
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/R CCB/ Isolator) - 8 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Single pole and neutral
Supply and erection of Outdoor pedestal garden light fittings made of aluminium body hollow pipe for about 450mm height made of dust and water resistant, premium finish, acrylic top dome with 1 x 20 W LED lamp. The fitting shall be IP 65 full Waterproof, Anti rust anti dust, resistant high quality materia. The lamp pedestal shall be fixed over the base with necessary bolts and nults and the rate is inclusive of making necessary connections, brass glands etc complete Make : Philips or Equivalent
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete
in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 70 watt
T LOBI DHAS (BID ID -1481247)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.