Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC | ₹46.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹51.5 LRejected-Finance | ₹51.5 L | L2 | Rejected-Finance L2 |
| 3 | L3₹53.0 LRejected-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | ₹53.0 L | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical NIKHIL GROUP BEHIND ICC TOWERS NEAR JW MARIOTT SHRI SHIVAJI CHS P NO 65 SENAPATI BAPAT ROAD PUNE MAHARASHTRA 411016 PUNE MAHARASHTRA INDIA 411016 | PUNE | MAHARASHTRA | 411016 | - | - | Rejected-Technical Technically Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | S AND J BUILDCON PRIVATE LIMITED L2 | VIJAY AIRCONDITIONING PVT LTD L1 | Speedfrost Services Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|
| 1.01 | Supply, erecting, installation, testing and commissioning of 26 HP modular type Variable Refrigerant Flow/Variable Refrigerant Volume (VRF/VRV) air cooled outdoor unit – complies type-IV OEM standards working on R410A refrigerant or equivalent environmentally acceptable refrigerant suitable for Indian climatic conditions. Air cooled outdoor unit with vertical hot air discharge should be suitable for cooling and heating application, complete with all accessories as required. The unit shall deliver rated cooling capacity at AHRI conditions, 100 % capacity at 47 oC and shall be capable of continuous operation at ambient temperature up to 56°C without tripping. The outdoor unit shall consist of hermetically sealed inverter scroll compressor(s), microprocessor-based control system, refrigerant piping accessories, vibration isolators and weatherproof powder coated cabinet.
Modules above 14 HP shall have minimum two compressors for improved reliability and part load operation. The system shall be suitable for long refrigerant piping applications as per OEM recommendations.The COP at AHRI conditions shall not be less than 3.7 and IEER shall not be less than 6.5. The unit shall operate on 415V ±10%, 3 Phase, 50 Hz AC supply.
Air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ±10%, 3 Phase, 50 Hz AC supply. The complete unit should be suitable for high ambient conditions. Internal copper refrigerant piping, internal wiring and control panel etc. all housed in powder coated weatherproof cabinet. | 2 | Nos | 11,49,608 ₹11,49,608 | 9,25,000 ₹9,25,000 Lowest | 13,20,860 ₹13,20,860 |
| 1.02 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipefor liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. | 40 | Rmt | 1,80,000 ₹1,80,000 | 1,875 ₹1,875 Lowest | 1,17,320 ₹1,17,320 |
| 1.03 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. | 10 | Nos | 12,184 ₹12,184 | 350 ₹350 Lowest | 77,050 ₹77,050 |
| 1.04 | Providing vaccumising the airconditioner system to 200 micron and charging with R-410A/R32 refrigerant for air conditioning unit. | 40 | kgs | 42,240 ₹42,240 | 625 ₹625 Lowest | 34,520 ₹34,520 |
| 1.05 | Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. | 4 | Nos | 30,076 ₹30,076 | 2,500 ₹2,500 Lowest | 11,500 ₹11,500 |
| 1.06 | Supplying and erecting UPVC pipe for drain of 32 mm dia. with required accessories on wall / ceiling as per specification No: WG-MA/CON. | 30 | Rmt | 3,510 ₹3,510 | 180 ₹180 Lowest | 10,890 ₹10,890 |
| 1.07 | Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete. | 2 | Rmt | 5,862 ₹5,862 | 1,500 ₹1,500 Lowest | 10,810 ₹10,810 |
| 1.08 | G.S.S. S.A/ R.A. ducting complete with, support rods, angles, channels, galvanized nut bolts, gasket at joints etc. fabricated as per IS specifications. The quantities are as follows -22 Gauge | 150 | Sq.Mt | 1,89,000 ₹1,89,000 | 250 ₹250 Lowest | 2,07,150 ₹2,07,150 |
| 1.09 | G.S.S. S.A/ R.A. ducting complete with, support rods, angles, channels, galvanized nut bolts, gasket at joints etc. fabricated as per IS specifications. The quantities are as follows -24 Gauge | 450 | Sq.Mt | 5,24,250 ₹5,24,250 | 375 ₹375 Lowest | 5,43,600 ₹5,43,600 |
| 1.10 | Providing adhesive thermal insulation for supply / return air duct with 19 mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC2007. | 690 | Sq.Mt | 7,15,530 ₹7,15,530 | 225 ₹225 Lowest | 5,04,390 ₹5,04,390 |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
3 Jun 2026, 5:00 pmClosed
Registrar
Registrar COEP Technological University Pune
Supply, Erection, Installation, Testing and Commissioning of HVAC Air Conditioning System of Mini Auditorium at COEP Technological University Pune
2026_DTEDM_1304903_1
COEP TECH/RFP/Central Store/ HVAC/MiniAuditorium/2026/106
Open Tender
Electrical and Maintenance Works
Lump-sum
70 days
Mini Auditorium at COEP Technological University P
Supply, Erection, Installation, Testing and Commissioning of HVAC Air Conditioning System of Mini Auditorium at COEP Technological University Pune
2 documents required · 2 mandatory
₹590
Yes
₹44,000
Yes
Conference Room, Instrument Department, COEP Techn
2 Jul 2026
22 May 2026
4 Jun 2026
22 May 2026
3 Jun 2026
22 May 2026
27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, erecting, installation, testing and commissioning of 26 HP modular type Variable Refrigerant Flow/Variable Refrigerant Volume (VRF/VRV) air cooled outdoor unit – complies type-IV OEM standards working on R410A refrigerant or equivalent environmentally acceptable refrigerant suitable for Indian climatic conditions. Air cooled outdoor unit with vertical hot air discharge should be suitable for cooling and heating application, complete with all accessories as required. The unit shall deliver rated cooling capacity at AHRI conditions, 100 % capacity at 47 oC and shall be capable of continuous operation at ambient temperature up to 56°C without tripping. The outdoor unit shall consist of hermetically sealed inverter scroll compressor(s), microprocessor-based control system, refrigerant piping accessories, vibration isolators and weatherproof powder coated cabinet.
Modules above 14 HP shall have minimum two compressors for improved reliability and part load operation. The system shall be suitable for long refrigerant piping applications as per OEM recommendations.The COP at AHRI conditions shall not be less than 3.7 and IEER shall not be less than 6.5. The unit shall operate on 415V ±10%, 3 Phase, 50 Hz AC supply.
Air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ±10%, 3 Phase, 50 Hz AC supply. The complete unit should be suitable for high ambient conditions. Internal copper refrigerant piping, internal wiring and control panel etc. all housed in powder coated weatherproof cabinet. | 2 | Nos | - | - |
| 1.02 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipefor liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. | 40 | Rmt | - | - |
| 1.03 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. | 10 | Nos | - | - |
| 1.04 | Providing vaccumising the airconditioner system to 200 micron and charging with R-410A/R32 refrigerant for air conditioning unit. | 40 | kgs | - | - |
| 1.05 | Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. | 4 | Nos | - | - |
| 1.06 | Supplying and erecting UPVC pipe for drain of 32 mm dia. with required accessories on wall / ceiling as per specification No: WG-MA/CON. | 30 | Rmt | - | - |
| 1.07 | Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete. | 2 | Rmt | - | - |
| 1.08 | G.S.S. S.A/ R.A. ducting complete with, support rods, angles, channels, galvanized nut bolts, gasket at joints etc. fabricated as per IS specifications. The quantities are as follows -22 Gauge | 150 | Sq.Mt | - | - |
| 1.09 | G.S.S. S.A/ R.A. ducting complete with, support rods, angles, channels, galvanized nut bolts, gasket at joints etc. fabricated as per IS specifications. The quantities are as follows -24 Gauge | 450 | Sq.Mt | - | - |
| 1.1 | Providing adhesive thermal insulation for supply / return air duct with 19 mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC2007. | 690 | Sq.Mt | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
HVACRFP.pdf
Tender Documents • 0.90 MB
BOQ_2240083.xls
BOQ • 0.33 MB
HVACCorrigendumpdf.pdf
PDF • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].