Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹11.8 L+₹1.3 L (12.7%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest bid |
Tender Value
₹12.7 L
EMD Value
₹25,400
Closing Date
7 Mar 2020, 6:00 pmClosed
GARRISON ENGINEER EAST JALANDHAR CANTT
GARRISON ENGINEER EAST JALANDHAR CANTT
MAINTENANCE AND OPERATION, COMPREHENSIVE MAINT AND REPAIR TO VARIOUS AC PLANT AT MH JRC UNDER GE (EAST) JALANDHAR CANTT.
2020_MES_314880_1
GE/JULL/ET-60/2019-20
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER EAST JALANDHAR CANTT
₹25,400
Yes
27 Apr 2020
11 Feb 2020
9 Mar 2020
11 Feb 2020
7 Mar 2020
24 Feb 2020
Amount
Servicing/Maintenance of walk-in cooler of capacity 9000 ltr with PUF panel cabin of size 7'9"x 7'9"x7'9" such as checking Gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motors, Cleaning and washing of complete indoor and outdoor unit and PUF cabin, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Material and labour for de-scaling of condenser-03 Nos for 2 x 5.5 TR (working capacity) & 1 x 5.5 TR standby AC central type with copper tubes by removing nuts & bolts, water connection and filling up of de-scaling acid HCL in condenser and manually cleaning of copper tubes with using Nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, nut & bolts of 5.5 TR condensing unit Model No SMC-2-65 complete all as specified and as directed.
All as per srl item No 2 here-in-before but for 2x 10 TR (Working capacity) and 1x10 TR stand by Ac Central type Model No SMC-3-65.(X-Ray)
All as per srl item No 2 here-in-before but for 2x15 TR (Working capacity) and 1x15 TR stand by AC Central type Model No SMC-6-65.(EME Zonal Workshop)
All as per srl item No 2 here-in-before but for 2x50TR (Working capacity) and 1x50 TR stand by water cooler chiller Ac plant(OT, MH)
M&L for disconnecting electric motor 7.5 HP and transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator duly varnishing and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC copper cable with stranded copper conductor from motor to connection plate, replacement of ball bearing, reassembling the motor, shifting to work site and connecting with the system, testing on full load complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 6 here-in-before but of 5 HP electric motor.
All as per srl item No 6 here-in-before but of 3 HP electric motor.
All as per srl item No 6 here-in-before but of 2 HP electric motor.
All as per srl item No 6 here-in-before but of 1 HP electric motor.
All as per srl item No 6 here-in-before but of 34 watt, single phase electric motor.
All as per srl item No 6 here-in-before but of 187 watt, single phase electric motor.
All as per srl item No 6 here-in-before but of 250 watt, single phase electric motor.
Material and labour for charging Nitrogen Gas in 2X15 tr working capacity+1X15tr standby AC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof complete all as specified and as directed. (EME Zonal Workshop)
All as per srl item No 14 here-in-before but of capacity 2X10TR working +1X10 TR standby.(in X-Ray AC Plant in MH)
All as per srl item No 14 here-in-before but of capacity 2x5.5 TR working +1X5.5TR standby. (in Heal stoke AC Plant in MH)
All as per srl item No 14 here-in-before but of capacity 2x50 TR working +1X50TR standby. (in OT AC Plant in MH)
Supply and charging refrigerant Gas R-22 for central AC plant of various capacities including testing of leakage, soldering and maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply and charging refrigerant Gas R-407 central AC plant of various capacities including complete labour charges for checking leakage and maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply and charging refrigerant Gas R-410 central AC plant of various capacities including complete labour charges for checking leakage and maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply and filling in fresh compressor oil N-68 for compressor of AC plant of various capacities to ensure the development of required oil pressure complete all as specified or as directed by Engineer-in-Charge. Make :- Indian oil/ Bharat Petrolium/ Servo Note :- Compressor oil shall be supplied in company sealed containers only.
Supply and replacement of discharge pressure gauge 4” dia, range 0 to 300 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and replacement of Oil pressure gauge 4” dia, range 0 to 200 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and replacement of suction pressure gauge 4” dia, range 0 to 150 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and replacement of water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and replacement of V- belt B-68 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
All as per srl item No 26 here-in-before but Size B-70
All as per srl item No 26 here-in-before but Size B-72.
All as per srl item No 26 here-in-before but Size B-94
Supply and replacement of V- belt A-31 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
Supply and replacement of V- belt A-32 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
Supply and replacement of V- belt A-34 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
Supply and replacement of V- belt A-36 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
Supply and replacement of thermostat expansion valve suitable for AC plant 50 tr capacity complete all as specified and directed. Make:- Sporlan/ Danfoss/ Renutrol or equivalent.
All as per srl item No 34 here-in-before but suitable for 20 TR capacity AC Plant.
All as per srl item No 34 here-in-before but suitable for 11 TR capacity AC plant.
Supply and fix in replacement Finned strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioning plant installed at various locations complete all as specified or as directed. Make:- Daspass/Lazer/Usha
Supply and fixing fully automatic star delta starter, 415V, 3 phase suitable for 60 HP motor. Make :- L&T/BCH/GE
Supply and fixing fully automatic star delta starter, 415V, 3 phase suitable for 12.5 HP motor. Make :- L&T/BCH/GE
Supply and fixing fully automatic star delta starter, 415V, 3 phase suitable for 20 HP motor. Make :- L&T/BCH/GE
S&F Fine filter of size 24"x12"x2" having dust filtration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
S&F Fine filter of size 24"x24"x2" having dust filtration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
S&F Fine filter of size 520mm x 460mm x 60mm having dust filteration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
S&F Fine filter of size 505mm x 420mm x 50mm having dust filteration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
S&F Hepa filter of size 24"x24"x12" having dust filtration level 0.3 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
Servicing/Maintenance of packaged type AC of capacity 5.0 TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of packaged type AC of capacity 15/11 TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of packaged type AC of capacity 22 TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Preparation of old painted surfaces of AC plant central type of capacity 3x 5.5 TR including all motors, condensers, pumps, MS Pipes of various sizes, cooling tower and LT electric panel board installed at Heat stroke plant room painting with super enameled paint of approved quality with spray gun two coats over a coat of red oxide paint complete all as specified and as directed
All as per srl item No 49 here-in-before but AC Plant of capacity 3x50 TR installed at OT.
All as per srl item No 49 here-in-before but AC Plant of working capacity 3x10 TR installed at X-Ray.
All as per srl item No 49 here-in-before but AC Plant of working capacity 3x15 TR installed at Zonal Wksp.
Supply and fixing compressor 7.5 TR performer, model 06 D / 018 for Voltas Packaged unit Model DUPA SH 1500 including gas charging and testing complete installed at ICU all as specified and as directed. Make- DANFOSS/ KIRLOSKAR/TECHMSAH
Supply and fixing connecting and testing of compressor scrolled sealed unit of capacity 5.5 TR performer, for Voltas Packaged AC plant including gas charging and testing complete installed at MRI and ECHS all as specified and as directed. Make- DANFOSS/ KIRLOSKAR/TECHMSAH
Supply and fixing of ON/OFF Push button with element complete all as directed.
Supply and fixing PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required. Model No - 22 TR PMN MPD Twin Make - Softhard Automation Pvt Ltd or in equivalent.
Supply and fixing PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required. Model No - 15 TR PMN MPD Twin Make - Softhard Automation Pvt Ltd or in equivalent.
Supply and fixing Contactor MNX, 32 amp complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing Contactor MNX, 45 amp complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing Contactor MNX, 25 amp complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing of indicator Neon lamp complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing of Ammeter analog type 0-200 Amp, 96x96mm CT Operated complete all as specified and as directed. Make- L&T/ Schiender/ Indotech
Supply and fixing of Ammeter analog type 0-100 Amp, 96x96mm complete all as specified and as directed. Make CTs 30/5. Make- L&T/ Schiender/ Indotech
Supply and fixing of Ammeter analog type 0-50 Amp, 96x96mm complete all as specified and as directed. Make CTs 30/5. Make- L&T/ Schiender/ Indotech
Supply and fixing of Voltmeter analog type 0-500 Amp, 96x96mm complete all as specified and as directed. Make- L&T/ Schiender/ Square
Supply and fixing ball bearing of size 6205. Make- SKF/NBC/TATA
Supply and fixing ball bearing of size 6306. Make- SKF/NBC/TATA
Supply and fixing ball bearing of size 6307. Make- SKF/NBC/TATA
Supply and fixing ball bearing of size 6308. Make- SKF/NBC/TATA
Supply and fixing toggle 5 Amp switch two way brass handle as per sample.
Supply and fixing LP HP cut out M15 as per sample. Make- Denfoss/indfoss
Supply and fixing compressor shaft oil seal of voltas 50 TR Model 05060S. Make-Voltas or equivalent.
Supply and fixing compressor shaft seal of make of compressor SMC Model 3/65 Make- Accel Sarbo or equivalent.
Supply and fixing compressor shaft seal of make of compressor SMC Model 6/65 Make- Accel Sarbo or equivalent.
Supply and fixing compressor shaft seal of make of compressor SMC Model 2/65 Make- Accel Sarbo or equivalent.
Overhauling of compressor 5.5 TR Model No 6/65 with replacing piston, sleeve, connecting rod, suction and discharge reads, capacity control valve, compressor shaft seal, servo 68 oil, crank shaft, etc testing complete all as per specified and directed.
Overhauling of compressor 10 TR Model No SMC 2/65 with replacing piston, sleeve, connecting rod, suction and discharge reads, capacity control valve, compressor shaft seal, servo 68 oil, crank shaft, etc testing complete all as per specified and directed.
Servicing / Repairing of cooling tower of capacity 11 TR plant by supply and fixing of nozzles, Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Servicing / Repairing of cooling tower of capacity 20 TR plant by supply and fixing of nozzles, Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Servicing / Repairing of cooling tower of capacity 100 TR plant by supply and fixing of nozzles, Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Supply and fixing automatic expansion valve for 50 TR OT plant Model No - MVE 42 CP 100.
Supply and fixing Main contactor Type 3TF 46 Make - Siemens/BCH/L&T/Schneider.
Supply and fixing Main contactor Type 3TF 34 Make - Siemens/BCH/L&T/Schneider.
Supply and fixing over load Relay 6 to 10 Amp Make -Siemens/BCH/L&T/Schneider.
S&F metallic air filter made out of galvanised iron frame and meshing of size 585mm x 630mm x 50mm having dust filtration level 30 micron 70% efficiency suitable for central AC plant complete all as specified and directed.
S&F metallic air filter made out of galvanised iron frame and meshing of size 460mm x 560mm x 150mm with non-woven synthetic media having dust filtration level 5 micron 90% efficiency suitable for central AC plant complete all as specified and directed.
Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant capacity 2x5.TR make Blue star as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant capacity 2x5.5TR make Blue star as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
Supply, fixing, connecting, and testing molecular drier cum strainer on line type of size 3/8" x 3/8" make Danfoss in AC plant capacity 2 x 5.5 TR make Blue star as per existing type and size including taking out of unserviceable drier complete all as per specified and directed.
Servicing/Maintenance of Cold store of capacity 2.5 TR such as checking Gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of Cold store of capacity 5.5 TR such as checking Gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of Cold store of capacity 8.5 TR such as checking Gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
LOVELY AIRCON SYSTEM
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .