| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAdmitted-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L1 | Admitted-Finance | |
| 2 | L2₹16.6 L+₹2.3 L (16.4%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹17.5 L+₹3.3 L (22.9%)Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L3 | Admitted-Finance | |
| 4 | L4₹17.7 L+₹3.4 L (24.2%)Admitted-Finance NO 1 4 56 Y SRI BHARATHI NAGAR OPP PARVATHI THEATER CUMBUM ROAD THENKARAI PERIYAKULAM THENI DT 625 601 | PERIYAKULAM | THENI | TAMIL NADU | 625601 | L4 | Admitted-Finance | |
| 5 | L5₹21.3 L+₹7.1 L (49.8%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GS TRADERS L1 | Vishwas Enterprises L5 | PRIYADARSHINI CONSTRUCTIONS L4 | kamadhenu Electricals L2 | SREE CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc. | 970 | Per Point | 20 ₹19,400 | 10 ₹9,700 Lowest | 15 ₹14,550 | 15 ₹14,550 | 10 ₹9,700 Lowest |
| 2.00 | M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade ISI mark with all accessories concealed in wall/ ceiling/floor / road etc, with cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and making good the distributed surfaces using cement plaster, levelling with existing surface complete all as specified and as directed for following-
One light/ fan/ bell point controlled by one switch | 30 | Per Point | 600 ₹18,000 Lowest | 800 ₹24,000 | 850 ₹25,500 | 720 ₹21,600 | 770 ₹23,100 |
| 2.01 | M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge | 50 | Per Point | 550 ₹27,500 | 800 ₹40,000 | 750 ₹37,500 | 410 ₹20,500 | 310 ₹15,500 Lowest |
| 2.02 | M & L 5 Amp socket outlet point on same board complete all as specified and directed by Engr-In-Charge | 20 | Per Point | 525 ₹10,500 | 100 ₹2,000 Lowest | 200 ₹4,000 | 140 ₹2,800 | 220 ₹4,400 |
| 2.03 | M & L 5 Amp socket outlet point independent but near switch board complete all as specified and directed by Engr-In-Charge | 30 | Per Point | 525 ₹15,750 Lowest | 800 ₹24,000 | 750 ₹22,500 | 720 ₹21,600 | 610 ₹18,300 |
| 2.04 | One light point controlled by two way switch complete all as specified and directed by Engr-In-Charge | 30 | Per Point | 700 ₹21,000 | 850 ₹25,500 | 800 ₹24,000 | 860 ₹25,800 | 685 ₹20,550 Lowest |
| 2.05 | All as per Item no 2 above here in before but with 2.5 sqmm size wire for power point concealed in wall complete all as specified and directed by Engr-In-Charge | 20 | Per Point | 800 ₹16,000 | 900 ₹18,000 | 800 ₹16,000 | 900 ₹18,000 | 750 ₹15,000 Lowest |
| 3.00 | M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for Phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade with ISI mark of appropriate size with all accessories concealed in wall/ ceiling/floor etc, with GI flush in box/terminal boxes of sutaible size, including front plate for mounting of modular switch/ socket and combined cover plate with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and flush in box and making good the distributed surfaces using cement based plaster/POP complete all as specified and as directed for following-
One light/ fan/bell/ point controlled by one switch | 70 | Per Point | 625 ₹43,750 Lowest | 800 ₹56,000 | 850 ₹59,500 | 800 ₹56,000 | 1,000 ₹70,000 |
| 3.01 | M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge | 100 | Per Point | 600 ₹60,000 | 800 ₹80,000 | 750 ₹75,000 | 410 ₹41,000 Lowest | 595 ₹59,500 |
| 3.02 | All as per Item No 3 above but for Modular type Socket 6/10 Amp of two module in independent board, 230 volts complete all as specified and directed by Engr-In-Charge. | 200 | Per Point | 600 ₹1,20,000 Lowest | 800 ₹1,60,000 | 800 ₹1,60,000 | 800 ₹1,60,000 | 910 ₹1,82,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jun 2026, 6:00 pmClosed
GE(South) Bangalore
GARRISON ENGINEER (SOUTH) NO 1 ULSOOR ROAD BANGALORE 42
REPAIR/ MAINT OF INTERNAL WIRING LIGHT FITTINGS, SWITCH SOCKETS, DBs AND CONNECTED ITEMS AT VARIOUS OFFICES UNDER DAD AND DAD RESIDENTIAL AREA UNDER GE (SOUTH) BANGALORE
2026_MES_766451_1
8128/E8
Open Tender
Civil Works
Item Rate
270 days
GE(South) Bangalore
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE(South) Bangalore
₹60,000
Yes
9 Jul 2026
20 May 2026
18 Jun 2026
20 May 2026
16 Jun 2026
3 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc. | 970 | Per Point | 100 | ₹97,000 |
| 2 | M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade ISI mark with all accessories concealed in wall/ ceiling/floor / road etc, with cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and making good the distributed surfaces using cement plaster, levelling with existing surface complete all as specified and as directed for following-
One light/ fan/ bell point controlled by one switch | 30 | Per Point | 10 | ₹300 |
| 2.01 | M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge | 50 | Per Point | 10 | ₹500 |
| 2.02 | M & L 5 Amp socket outlet point on same board complete all as specified and directed by Engr-In-Charge | 20 | Per Point | 10 | ₹200 |
| 2.03 | M & L 5 Amp socket outlet point independent but near switch board complete all as specified and directed by Engr-In-Charge | 30 | Per Point | 10 | ₹300 |
| 2.04 | One light point controlled by two way switch complete all as specified and directed by Engr-In-Charge | 30 | Per Point | 10 | ₹300 |
| 2.05 | All as per Item no 2 above here in before but with 2.5 sqmm size wire for power point concealed in wall complete all as specified and directed by Engr-In-Charge | 20 | Per Point | 10 | ₹200 |
| 3 | M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for Phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade with ISI mark of appropriate size with all accessories concealed in wall/ ceiling/floor etc, with GI flush in box/terminal boxes of sutaible size, including front plate for mounting of modular switch/ socket and combined cover plate with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and flush in box and making good the distributed surfaces using cement based plaster/POP complete all as specified and as directed for following-
One light/ fan/bell/ point controlled by one switch | 70 | Per Point | 10 | ₹700 |
| 3.01 | M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge | 100 | Per Point | 10 | ₹1,000 |
| 3.02 | All as per Item No 3 above but for Modular type Socket 6/10 Amp of two module in independent board, 230 volts complete all as specified and directed by Engr-In-Charge. | 200 | Per Point | 10 | ₹2,000 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
Tenderdocument8128.pdf
Tender Documents • 0.92 MB
BOQ_858412.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .