| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 701 HEADQUARTERS SANT DNYANESHWAR MARG CHETANA COLLEGE ADJUNCT BANDRA EAST MUMBAI 400051 | MUMBAI SUBURBAN | MAHARASHTRA | 400051 | ₹1.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹5.2 L (2.99%)Rejected-Finance | ₹1.8 Cr+₹5.2 L (2.99%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.8 Cr+₹6.8 L (3.88%)Rejected-Finance | ₹1.8 Cr+₹6.8 L (3.88%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹1.8 Cr+₹8.8 L (5.06%)Rejected-Finance | ₹1.8 Cr+₹8.8 L (5.06%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹1.9 Cr+₹14.7 L (8.43%)Rejected-Finance | ₹1.9 Cr+₹14.7 L (8.43%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
13 Mar 2021, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
PROVN OF DEFI BAGGAGE ROOM AND GUARD HOUSE AT MIRC AHMEDNAGAR
2020_MES_407082_1
84489E8
Open Tender
Civil Works
Lump-sum
365 days
GE SOUTH AHMEDNAGAR
AS PER NIT
5 documents required · 5 mandatory
₹1,000
GE ( South) Ahmed Nagar
₹2.6 L
31 Mar 2021
26 Dec 2020
16 Mar 2021
27 Dec 2020
13 Mar 2021
27 Feb 2021
27 Dec 2020 - 20 Jan 2021
Amount
NOTE: Schedule ‘A’ Part I to VIII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I (Building Works)
Total amount of Sch 'A' Part-II (Internal water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electric Supply)
Total amount of Sch 'A' Part-VI (Sewage Disposal)
Total amount of Sch ‘A’ Part VII (Area drainage)
Total amount of Sch ‘A’ Part VIII (Excavation & Earthwork)
SCH 'A PART IX (Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Supply and fix telephone socket 2G complete all as specified and as directed.
S & F LED maximum 20 Watt LED IP 20 Batten with extruded aluminium housing i anodised finish, minimum system Lumen output 2000 lumen with 6500 K CCT with PF>0.95 CRI>=80 and with <=20 % THD, with high Surge protection 3.5 KV and operating temperature 0°C to 45°C , integrated LED driver offers comfortable softlight, high durability, Driver safety requirement standard: IS 15885-2-13, The report to be submitted Photo Biological safety norms. IS 16108, The certificate to be submitted ; Certification LM 79 for Luminaire LM 80 for LED Source. Make as per Appendix 'C'.
S & F 10 Watt LED Bulk head fitting including LED lamp, pressure die cast aluminium housing with IP 65 rating , LED fixture system wattage of 10W, 140V-260 V AC, System Lumen Output min 950 Lumen with 5700 -6500 K CCT with PF >0.95 CRI >=80 and with <=15 % THD, with min 2.5 KV Surge protection in built and complete LED fixture with BIS R mark and R Registration no. all as specified and directed. Make as given in Appx 'C'.
S & F of LED light fitting out door type Building security light 25W to 30W fixture consist of Extruded Aluminium Extrusion housing with PC Diffuser, LED Fixture System wattage of 36W /40W, 140V - 260V AC, System Lumen Output min 3960 Lumen in 36W or 4400 lumen in 40W with 5700 - 6500 K CCT with pf > 0.95, CRI >=80 and with < = 10% THD, with min 2.5 KV Surge protection in Built and complete LED fixture with BIS R mark and R Registration no. alll as specified and as directed. Make as given in Appx 'C'.
M &L for submain wiring with 2 single core FRLS PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed. Note: 3 runs (2+1) of FRLS PVC insulated unsheathed multistranded flexible copper conductor and one run of PVC conduit heavy grade shall be measured as one unit.
S&F MCB Single pole 240 volts 6 Amps to 32 Amps 10 KA , 'C' series, complete all as specified and directed.
S&F MCB Single pole and neutral 240 volts 40 Amps 16 KA complete all as specified and directed.
S&F MCB TPN, 415 volts, 63 Amps 10 KA complete all as specified and directed.
Supply & fix PVC body exhaust fan 225mm sweep, 1400RPM, single phase, light weight, white/ivory plastic rust proof body & blades, self opening louvers for protection from birds and rain water, fixing by means of rugged bolts, nuts and washers etc on the round hole cut in wall, including three core copper conductor flexible cord of 0.5sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply. Make as listed in Appendix 'C', complete all as specified and as directed.
Supply & fix ceiling fan, 1200 mm (48") sweep with BLDC motor, 5 star rating BEE mark (after assembling the same with the fan hook/box) with the fan hook/box and connecitng up complete with and including electronic fan regulator stepped type, modular type, 2 module flush and with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan. Make : Bajaj Cat No KASSEL STAR or equivalent in makes listed in Appendix 'C', complete all as specified and as directed.
M & L for cutting /drilling exisitng pipe line and taking branch connection complete includig all necessary GI fittings, jointing materials , earth work etc complete all as specifed and as directed.
Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete of following sizes :-
(a) 25 sqmm x 3.5 core
(b) 6 sqmm x 2 core
S & F factory made PVC weather proof , hinged door, Junction boxes of size 250x200x80mm for street light fittings, weather proof IP-54 protection, hinged door, with Bakalite connector 100 Amps capacity, 4 way and 01 No MCB SP of 6Amp, necessary fixing arrangement such as clamps, nuts, bolts, with and including 2 Nos GI pipe 1m long each for cable entry and exit all as specified and as directed.
S & F LED street light fittings in aluminium housing, with heat resistance toughened glass & IP 65 protection, 60W, as in road light luminaire with high power LED and Including bracket made out of 40 mm dia GI pipe light grade of length 1.5 Mtrs with necessary clamps , nuts bolts and washers etc necessary fixing arrangements and including connecting flexible copper conductor wire PVC insulated of 2x2.5Sqmm and 1x2.5Sqmm as in earth conductor all as per Havells Cat NO ENDURAPEARLNEOSL60WLED 757PASYTOPC or equivalent of make listed in Appendix 'C', complete all as specified and as directed.
M &L for PVC insulated sheathed cable with stranded aluminium conductor of size 2.5 Sqmm single core from fitting to junction box complete all as specied and as directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing wire 4mm dia by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 32x6 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
Design, supply, installing, testing and commissioning of weather, dust and vermin proof LT distribution panel board factory made, outdoor type of suitable size so as to accomodate the following accesories, depth not less than 500mm, IP 54, and all as per IE rules, prewired and fabricated with 3.15mm thick CRCA sheet epoxy power coated double door with aprons, duly powder coated after seven tank process with fully compartmentalised / modular construction with Bus bar and cable ally, mounted on MS 50x50x6mm angle iron frame and in shape with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C-1 using 20mm graded coarse stone aggregates complete with leg 50cm grouted in ground in PCC at 40cm above ground, including connection cable with cable glands, lugs etc and consisting of the following:- . Note: PCC plinth will be measured and paid separately.
(a) Copper bus bar 200Amps-04 Nos for phases and 01 Nos for neutral duly colour sleeved mounted on epoxy insulator-01 Set
(b) Incoming
i) MCCB 100 Amps, FP, 415V, 50Hz ICU 35 KA thermal magnatic release type - 01 No
(c) Outgoing
i) MCCB 63 Amps, FP, 415V, 50Hz ICU, 25 KA thermal magnatic release type- 2 No.
ii) Street light timer switch of ccapacity 5KW-01 No
iii) Multi function meter to measure voltage, current, frequency & Power factor- 01 No
iv) LED type indicator lamp (R,Y,B) set of Three. - 01 Nos.
v) LT Danger board
vi) Panel control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
Note: Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
G.M. Construction
ganesh electricals and airconditioners
SUYOG CONSTRUCTIONS
MUDRIK ENTERPRISES
N. H. Saluji & Associates
M/s S. R. Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .