Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.4 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹54.7 L+₹11.3 L (26.0%)Rejected-Finance 77 BHULLAR AVENUE FGC ROAD AMRITSAR 143001 | AMRITSAR | PUNJAB | 143001 | 2 | Rejected-Finance Higher |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
28 Oct 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar PIN-143001
PROVN OF STORE ROOM FOR EST BRANCH, ADDN/ALTERATION TO BLDG NO P-23 AT 15 INF DIV AND EMP COY AND OTHER SANCTIONED WORKS UNDER GE AMRITSAR
2020_MES_378526_1
GE/ASR-31/2020-21
Open Tender
Civil Works
Item Rate
335 days
GE Amritsar
Class D, Category ai
8 documents required · 8 mandatory
₹500
GE Amritsar
₹87,300
Yes
13 Nov 2020
25 Sept 2020
29 Oct 2020
25 Sept 2020
28 Oct 2020
15 Oct 2020
60 days
Amount
B/R PORTION Surface dressing n exc 15 cm deep in soft/loose soil
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in any type of soil complete all as specified and as directed.
Excavation over areas, n.exc 1.5m in depth and getting out, in any type of soil complete all as specified
Add to Item no 04 depth exc1.5 m and not exc 3m all as specified and as directed.
Add to Item no 04 depth exc 3 m and not exc 4.5m all as specified and as directed.
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed.
Removing surplus spoil to a distance exceeding 50 meter and nexc 250m depositing where directed at a level not exceeding 1.5 meter above the starting point , complete all as specified .
Filling in floors using surplus excavated soil Spreading and levelling in layers n exc. 25 cm thick and rammed including watering
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) in bed blocks for hold fast, roof kerbs, or mud stops, rounded or chamferred on edges & similar work etc complete all as specified and directed
M & L for 50 mm thick, PCC 1:3:6, Type C-2, using 40mm graded aggregate as in plinth protection etc complete all as specified and as directed.
M & L for 75mm thick, PCC 1:4:8, Type D-2, using 40mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in surface of channel,drain,benching for manholes, bands, coping, bed plate etc including slightly chamfered or rounded angles including including necessary form work, if any, and finishing exposed surface even and smooth using extra cement complete.
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in columns.
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in beams.
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in chajja and fascia
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L RCC M-25 (Design Mix) using 20 mm graded stone aggregates as in stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings complete
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Formwork to sides of fair finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Fair finished Square, rectangular or polygonal Form work to sides of pillars, posts, struts, columns and stanchions.
Fair finished flat Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc.
Fair finished flat form works to soffits of suspended slabs such as roof slabs, floor slabs, landings chajjas and similar work; not exceeding 200mm thick (Horizontal or sloping)
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work
M & L Brick work built CM 1:6 subclass B brick strength curved or plan exc 6m mean radius.
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cm 1:4
M&L brickwork with subclass 'B' bricks in one brick thick honey comb wallling, built in cement mortar 1:4
M&L rendering 15mm thick on fair face of brick or concrete surface in CM 1:4 to be finished even and fair without using extra cement complete all as specified.
M & L for 15mm rendering in cement mortar (1:6) on brick/concrete surfaces finished the surface even and smooth without using extra cement.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3 finishing even and smooth without using extra cement complete all as specified and directed
Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of alkali resistant primer all as specified and directed.
M&L for preparation of newly plstered wall surface and applying two coats of cement Base all as specified as directed by Engr-in-Charge.
M&L for applying two coats of white wash ceiling surface and all as specified as directed by Engr-in-Charge.
M&L for applying two coats of white wash wall surface and all as specified as directed by Engr-in-Charge.
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red/zinc oxide primere.
M&L two coats of synthetic enamel paint over a coat of pink primer over wooden surfaces including preparation fo surfaces complete all as specified.
M& L for Box type steel window double (glazed & gauged) emade of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame comprise glazed skelton shutter door frame of ERW tube P-section size 50 mm x 20 mm with two Nos openable leaf cnsisting of two Nos of sash bar of T-sec 20 mm x 3 mm welded to frame with one No vertcale mullion of ERW of ERW box type T-section size of 60 mm x25 mm FI 2 mm thick welded / screwed to frame for fixing of wire guage/glass including fixture and fitting like as handle, tower bolt stopper , cleat, pintal hinges, holdfast primer etc, all as shown on drg No.CEJZ/TD-06/07 and CEJZ/TD/07/07 complete.
S & F mild steel box type ventilator fixed type with glazing bar with mesh & glass as per drg No. CEJZ/TD-06/07 dt 07.06.07 primer coated complete all as specified.
S&F Framed work confirming to FE- 290 (Gde-E- 165) as in doors chowkhats, gratings, grills/guard bars iron doors ladders; framed balusters walk ways railings framework of watertanks or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete
S&F factory made 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specfied and directed.
S&F 1mm thick Plain, galvanised, mild steel sheeting, in ridges, crumple joints, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and fixed with steel screws.
S/F 35 mm thick glazed and Skelton shutters IInd class hard wood open rebated prepared to receive in SSR part-I class 8 (R) glass gage dividing in squares size of member as per specified
S & F Solid PVC door frame of size 50mmx47mm made out of 5mm colour PVC sheet, edges will be painted to match with colour sheet, reinforced with MS square tube & fixing in opening.
S & F Factory Made Solid Panel PVC door shutter 30mm thick (stiles) consisting of frame made out of MS Tubes for top & bottom rails, MS frame shall be covered with heat moulded colour PVC sheet and 5mm thick x 15mm wide PVC sheet beading used inside stiles & rails and decorative PVC beading of 10mmx10mm used instead of exposed portion of PVC sheet beading.
S&F PVC valveless , syphonic action flushing cistern 10 ltr capacity, low level, white, with inlet, ball valve , float and handle including brackets and PVC flush pipe complete all as specified.
S&F rotational moulded polythyene 500 litrs water storage tanks cylindrical vertical with closed top hoisted and fixed in position incl. 20mm dia float valve brass fitting. All as specified and directed
S & F Vitreous China Wash hand basin, white flat back size 550x400 mm including brackets(including Pillar Tap 15 mm bore Chromium plated cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts & PVC waste pipe and 600mm long PVC connector 15mm) all as specified & directed by Engineer-in-charge.
S & F Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap & Provision of concrete bedding and making good to floor all as specified & directed by Engineer-in-charge.
S&F Vitreous China urinals, halfstal type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;
S&F Stop valve of PTMT for 20 mm bore of pipe any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm92gms)
S&F Angle stop valve of PTMT for 15 mm bore of pipe any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms
S & F Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm125gms).
S&F concealed Stop valve of PTMT any colour high pressure with long shank and cup (concealed type), (Minimum weight 15mm-110gms/20mm112 gms) screwed for iron pipe and fixed.
S & F swivel Shower of PTMT any colour for fixing with 15mm pipe(min weight 40 grm) . Including shower arm
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms
S&F PVC connections 15mm size with PTMT nuts of length 600mm
M&L PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S & F Grating doom 100mm dia with wast hole of PTMT (Min weight 25 gms).
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches floors or fixed to walls
S & F 110 mm bore PVC (SWR) bends of any radius.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door.
S & F 110 mm bore PVC (SWR) Vent Cowl
Supply and Fix 15mm bore water tubing medium grade galavanised with all fittings and is fixed complete to walls and ceiling or laid in floors.
Supply and Fix 20mm bore water tubing medium grade galavanised with all fittings and is fixed complete to walls and ceiling or laid in floors.
S & F 40mm bore tubing Medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
S&F butt hinges 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised type C-21 all as specified.
S&F butt hinges medium weight cold rolled mild steel complete size 100mm
S&F 200mm long aluminum anodized barrel tower bolt of extruded section and fixed all as spd and directed.
S&F Aluminium, anodised, barrel tower bolts of extruded section all as specified of size 150mm long
S&F MS 300mm long ordinary helical mild steel stove enameled black door spring including rollers and roller plate complete
S&F extruded aluminium alloy handles, fabricated type, anodised all as specified of size 150mm long
S&F 300mm long aluminum alloy anodized sliding door bolt with hasp and staple(bolt type)and fixing clips of sheet cast or ectruded sec and fixing bolts and sliding bolts of extruded sec or cast aluminum alloy and fixed all as spd and directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exc 0.5 sqm in each pane complete all as specified and directed.
S&F 4mm thick figured glass pane ordinary quality glazing with oil putty not less than 0.5 sqm each pane complete all as specified and directed
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staples.
M & L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm at 180 degree temperature in each layer ( first layer below APP membrane and second layer above APP membrane) on 0.40 kg/sqm bitumen primer surfaces including cleaning surfaces etc complete all as specified and directed
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on bitumen surfaces by forced application complete all as specified.
M & L 40mm thick brick tiles laid over15 mm thick cement plaster(1:4) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement
M & L for hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface in broken boulder complete all as specified and as directed.
M&L for ATT, Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M & L for providing Machine pressed pre-cast concrete interlocking paver blocks any shape and size conforming to IS-15658-2006 of thickness 60 mm over incl 25 mm sand filling including watering and consolidation etc complete all as specified
S&F drain pipes of 150mm bore RCC NP3 laid in trenches and jonted and tested complete all as specified
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as concrete bed, laid to falls in trenches in any depth including packing under, and haunching against the sides of pipes 150mm bore, after the pipes have been laid and tested including complete all as specified and directed
M&L for precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as cover slab for manhole and similar work etc complete all as specified and directed.
Cutting into exisiting manholes for connecting new drains, making good to pipe and rendering ,cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished , and reforming benching as required for 150mm/200mm/300mm bore of pipe.
M&L for 75mm dia Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors
M&L for 75mm dia Cast iron cowls
M&L Loose filling with brick aggregates of gauge 80 to 150 mm in soakage pits, soakage wells
M&L for glazed ceramic coloured tiles 450x300x7mm thick as in dado/skirting set and jointed in neat cement slury and pointed in coloured cement to match over and including 10mm thick backing coat in cement mortar 1:4, complete all as specified and as directed.
M/L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15 mm thick in CM (1:6) all as specified.
M & L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick cement screed in CM(1:6) set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the colour of tiles complete.
M&L for Machine cut Kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20mm thick screed bed in CM 1:6.
All as per item No 96 above but CM 1:4, 10 mm thick on skirting all as specified and directed
M & L for laying of LT cable of 1100 volt XLPE insulated and PVC sheathed of size 10 sqmm 2 core with cable gland including taking down old unserviceble cable complete all as specified and directed by Engineer-in-Charge.Make Havells, Glostar & polycab or equivlant make available in Mkt.
M & L for brick protection to cable using old size sub class 'B' bricks, laidflat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified & directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of calbe in trenches complete all as specified & directed.
Supply and fixing /laying galvanised pipe 25 mm bore medium grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
S & F PP-R Gate valves (brass insert) OF SIZE 20 mm dia including connection complete all as specified and directed.
S & F PP-R Gate valves (brass insert) OF SIZE 40 mm dia including connection complete all as specified and directed.
M&L for valve pit of brick machiery of internal diamention 600x600x700 mm (bottom PCC of the pit should be minumum 30 cm as below the bottom surface of gate valve flange to provide suficient working space bottom floor of the pit constructed in PCC ( 1:3:6 ) 15 cm thick with 20 mm stone aggregate inner and expost surface and bottom floor of the pit should be plastered in cm ( 1:4) 15 mm thick all brick work shall be sub class B bricks old size in cm 1 : 4. The gate valve and other fitting should in night angle and chamber . The top cover of the pit will be made of MS Sheet minimum 2 mm thick with angle iron frame made out of MS angle 15 mm x 15 mm in 6 mm with galvanized steel hinges 2 Nos and locking arrangement duly painted to 2 coat of water resistant synthetic anemal over one coat red oxide all as specified and directed.
E/M PORTION M & L Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to IS specifications, drawn through and including conceled conduit concealed/ fixed on wall / ceiling with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified and as directed :-Make of wire :- Finolex /Polycab/RR Kabel (a) One light point/Bell/Fan point controlled by one switch.
All as per item No 105 above but one 3 pin 5 amps switch socket on independent board.
All as per item No 105 above but one 3 pin 5 amps switch socket on same board.
All as per item No 105 herein before but with cable 2.5 sqmm (nominal area) multistranded copper wire unsheathed FR Cable for one 3 pin socket outlet 15 amps on independent board including continous earth wirte PVC insulated 2.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete all as specified and directed Note for items Nos 2&3 :- (a) The wiring shall be done in proper colour coding using red,yellow and blue for phase,black for neutral and green for earth leads.
Supply and fix switch piano one way 5 A, SP, 230 Volts.Make Anchor/SSK/Plaza
Supply and fix Socket outlet 2 in 1, 3 pin 5 Amps Flush type. Make Anchor/SSK/Plaza
Supply and fix Switch outlet 2 in 1, 3 pin15 Amps Flush type. Make Anchor/SSK/Plaza
Supply and fixing ceiling rose surface bakelite 3 terminals 65x32mm complete all as specified Make Anchor/SSK/Plaza
Supply and fix stepped type electronic fan regulator flush type all as specified and directed. Make Anchor/SSK/Plaza
S&F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant/batten fittings complete all as specified and directedMake Anchor/Plaza/SSK
Supply and fix wall/ceing mounting LED 18 Watt PC Diffuser tube light fitting complet with all aceesories 1x18W LED suitable for domestic application 240Volts 50HZ including one tube rode and internally pre-wired with 1.5 sqmm twin twisted flexible copper conductor and complete . Make Havells/ Wipro /Philips
S&F energy saving new generation 10 watt LED, 6000k bulk head luminaire with opal diffuser light fitting complete with all acessories and connection complete. Make Philips/Wipro/CG
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. Make Schneider/Siemens/Legrand
S & F in repair MCB double pole, 240 volts, 32 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make Schneider/Legrand/Siemens
S & F in repair MCB double pole, 240 volts, 16 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make Schneider/Siemens/Legrand
S & F in repair MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make :Legrand/Hager /Schneider Elect
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed. Make Anchor/SSK/Plaza
S&F Exhaust fan 300 mm sweep including cutting of walls , louvers nut and bolts etc including connection complete all as specified and directed.Make Havells/CG/Bajaj
S & F Ceiling fan star rated 1200 mm sweep inlcuding fan hook and all accessories complete with including fitting and fixtures as per site requirement and complete accessories 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor all as specified and directed. Make: Havells /Orient/CG/Bajaj
Supply and fix in replacement of security light fitting LED 25 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed. Make Philips/Wipro/CG
Supply and fix in replacement of security light fitting LED 36 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed of Make Jaguar /Philips/Havells or equivalent
S& F GI bracket light grade GI Pipe 1.2 mtr Length for fixing of street light fitting 36/40 Watt including connection all as specified and directed.
S & F point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point controlled by one, one way switch with 1.5 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated 1.50 sqmm size copper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed, are as follows :-Make RR Kabel/Polycab/Havells (a) One light point controlled by two Nos of two way switch
Supply and fixing of switch piano flush button single pole two-ways 5 Ampere complete all as specified and directed. Make Anchor/Plaza/SSK
Supply and Fixing Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size ,complete ,all as specified. Make Anchor/Plaza/SSK
M & L for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 2.5 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed. Including taking down old unserviceable sub main wiring .NOTE: 3 single core 2.5 sqmm and PVC conduit shall be measured as one RM. Make RR Kabel/Polycab/Havells
M & L for sub main wiring conforming to IS specifications, 2 runs of 4 sqmm including 1 run of 4 sq mm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Make of FR wire; Polycab/Havells/RR Cable,Make of PVC Pipe - Polycab/FInolex/Kalinga premium. Note : 2 Run of 4 sqmm, 1 Run of 4 sq mm and 1 run of PVC conduit will be mesuared as 1 unit.
NU DOLPHIN ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .