Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.5 LAccepted-AOC | 1 | Accepted-AOC Due to L1 | |
| 2 | 2₹13.3 L+₹1.5 L (12.6%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹14.2 L+₹2.4 L (20.1%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹17.0 L+₹5.1 L (43.5%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹19.0 L+₹7.1 L (60.4%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Jun 2024, 6:00 pmClosed
GE (AF) ADM AREA AGRA
GE (AF) ADM AREA AGRA
MAINT REPLACEMENT OF INTERNAL ELECTRIC WIRING INCL FITTING AND OTHER CONNECTED WORKS FOR OTM/MD ACCN IN 4 AREA UNDER GE (AF) ADM AREA AT AF STN AGRA.
2024_MES_654465_1
8000-2150/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) ADM AREA AGRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE (AF) ADM AREA AGRA
₹40,000
Yes
9 Jul 2024
17 May 2024
15 Jun 2024
17 May 2024
13 Jun 2024
1 Jun 2024
Amount
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
M & L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodise press steel sunk box having thickness not less than 2 mm with 3mm thick ISI marked bakalite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in , cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per srl item No 2 above but for call bell point complete all as specified and directed.
All as per srl item No 2 above but for 5 pin 5 amps socket outlet independent board complete all as specified and directed.
All as per srl item No 2 above but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
All as per srl item No 2 above but for one 3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm cable and 2.5 sqmm cable as earth continuity conductor.. Note: (a) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
All as per srl item No 2 above but for wiring with 4.00 Sqmm for 15 Amps switch socket combination on ndependent board/two pin earth plug and socket including 4 Sqmm PVC insulated multi stranded unsheathed copper earth continuity conductor and connected to common earth dolly.
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S & F bell push flush type 5 amps SP 240 volts complete all as specified and directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S & F call bell AC , 230 VOLTS, single pole complete all as specified and directed.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
S & F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S & F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- Havells Cat part No- LUMILINE+BS20WLED865SPCSS or ORIENT Cat part No-LBLN-20-C-AL or Phlips Cat part No- BN021C LED22S PSU CW GR
S&F in replacement of old U/S tube light fitting with energy saving decorative batten type 10 watt energy efficient tube light fitting (2 Feet) highly durable surface mounted LED batten constructed of fire retardent engineering grade extruded plastic and decorative end caps with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make- ORIENT Cat part No-LBLN-10-C-SQ or Phlips cat part- BN021LED12S6500PSUGR or Havells Cat part No- LUMILINE+ BS10WLED865SPCSS
S&F in replacement of old U/S tube light fitting with energy saving decorative batten type 10 watt energy efficient tube light fitting (2 Feet) highly durable surface mounted LED batten constructed of fire retardent engineering grade extruded plastic and decorative end caps with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make- ORIENT Cat part No-LBLN-10-C-SQ or Phlips cat part- BN021LED12S6500PSUGR or Havells Cat part No- LUMILINE+ BS10WLED865SPCSS
S&F fixing 18 W LED tube with builtin driver complete all as specified and directed Make :- ORIENT Cat part No-LTXL-18-C or Phillps cat part No-MAS LEDTUBE 18W,865T8I-1800LM, or Havells Cat part No- PHOTO NULTRAE2 .01213T8 SSTL 18WLED865SPC
S&F in replacement decorative wall light fitting including LED lamp complete all as specified and directed. Make:- Phlips Stylo wall light, Havells cat part No.- LHFHANDBTN1O007, Halonix cat part No.- HLWB-01-E27 .
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Make:- Orient cat part No-LTRHD-36-C/ Phillps cat part No-RC380BLED36S-6500 G6 L60W60PSUOD /Havells Cat part No- VENUSNEOHE2X2R36WLED830PIRSENSOR
M&L for replacement of existing unsv street light fittings with LED street light fitting 36 Watts with dusk dawn sensor ,automatic switch on and switch off operation based on ambient lux lavels, ,having cast alumn housing, polycarbonate diffuser , secondary optical lance, IP 65, including making connections complete all as specified and directed. Make: Orent Cat Ref LSFT 036C -DLS or equivalent to Phillips / Wipro / Havells/ Halonix
S & F MCB single pole 240 volts, 'C' curv of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specfied and directed.
S & F MCB SPN 240 volts, 'C' curv of rating 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specfied and directed.
S & F in replacement of MCB 415 Volts, 50 Hz, 40 Amps 4 pole C curve with rupturing capacity 10 KA complete all as specfied and directed.
S & F in replacement of MCB 415 Volts, 50 Hz, 63 Amps 4 pole C curve with rupturing capacity 10 KA complete all as specfied and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing complete all as specfied and directed.
M & L for replacement of existing unsv submain wiring with two single core PVC insulated flexible copper conductor cable (FRLS)of sze 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specfied and directed.
M & L for replacement of existing unsv submain wiring with two single core PVC insulated flexible copper conductor cable (FRLS) of sze 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specfied and directed.
M & L for replacament of existing old unsv earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed. (Note: Excavation and earth work is deemed to be included in the rates quoted).
Dismantling of existing meter panel board removing existig energy meter keeping safe custody and Design ,Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 650X245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparant Door foor meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE only . DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make . The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrrangement. (a) Four pole MCCB 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incomming side - 01 No. (b) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover
S & F in replacement of MCCB 415 Volts, 50 Hz, 63 Amps 4 pole with rupturing capacity 16 KA including providing thimbles for out-going cables complete all as specfied and directed.
S & F in replacement of MCCB 415 Volts, 50 Hz, 100 Amps 4 pole with rupturing capacity 16 KA including providing thimbles for out-going cables complete all as specfied and directed.
S & F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 5"x5" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specfied and directed.
S & F in replacement of existing unsv/ broken bakellite sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specfied and directed.
S & F in replacement sheet metal single pole and neutral enclosure with socket, plug top complete with one single pole MCB of 20 Amps, 240 volts including cutting of wall complete all as specfied and directed.
Supply and fixing inreplacement two way terminal block 63 Amps , two way, screw clamp including nut bolt ,washer suitable for mounting in existing din rail complete all as specfied and directed.
Disconnecting and taking down old energy meter and Supply, installing, testing & commissioning of smart RF single Phase meter with AC single phase two wire, tamper proof static meter of class 1.0, 240 V, 50 Hz, 10 A to 60 A confirming to IS-16444 and relevant IEC standards within built 865-867 MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti temper features, Microprocessor and LED/LCD based circuitry. Meter should support sending the 15/30 mint instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for cumulative energy and Max demand to software data. Meter should have connect/disconnect functionality operable from MDM/billing software and prepaid features should be MDM/billing end as per IS-15959 part 2. The meter should support open DLMS with the software complete all as directed. Make:- L&T cat part No. WM101BC7DLPR6INN or equivalent in Secure/Havells/HPL Note:- Old Electric meter shall be deposited at E/M store yard.
S & F in replacement existing U/S light fitting with energy saving decorative LED batten 36 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less thtn 0.95) complete all as specified and directed. Make- Havells Cat part No- LUMILINESMART36WLED865PCWH , ORIENT Cat part No-LBLN-36-C-AL /Phlips Cat part No- BN170C LED40S-6500 PSU L120
Dismantling of existing and Supply and fixing PVC sunken box with PVC top cover , 01 switch piano and 01 socket , 2 in 1 of 5 Amps , ISI Marked including cutting of existing wall making good as per exiting surface complete all as specfied and directed.
S & F in replacement of existing unsv/ broken mild steel pressed sheet 1.6mm thick sunken box of size 4" x 4 " all as required at site including cutting of wall and making good complete all as specfied and directed.
All as per item no- 42 but of size 7"x 4" complete all as specfied and directed.
S & F in replacement existing U/S light fitting with energy saving decorative 36 Watt downlight , IP-20, colour tempreture - 4000K , CRI -80, IK03, approximate size (113.6 X 16.3 X 4.6) cm and including adjustable suspended kit , Up-Down End Cap, ceiling clamp and making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less thtn 0.95) complete all as specified and directed. Make- Havells Cat part No- SABERLP36WLED857SPMM , ORIENT Cat part No-LCPDL-36-C-75 /Phlips Cat part No- SP571P LED33S 6500 PSU W12L120 OD SI
S & F in replacement of switch piano flush type single pole one way. 5 amps 240 volts ISI Marked in existing position complete all as specfied and directed.
S & F in replacement of energy efficient , intant on , high efficiency rechageable emergency inverter LED bulb 8.5 W in existing position. Make :- BAJAJ /Wipro/ Havells/ Philips
Supply and fixing in replacement mild steel anti suicide fan hanging road 1.5" feet long poder coated as approved by Engr-in charge complete all as specfied and directed.
S & F in replacement of socket outlet 2 in 1, 5 Amps flush type, 240 Volts ISI Marked in existing position complete all as specfied and directed.
MUKTA AND COMPANY
M/s Sumer Associates
Balaji Associate
jmd engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .