Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC 10 SHANTI VIHAR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | ₹2.4 Cr Quoted ₹2.5 Cr | L1 | Accepted-AOC Lowest Bid L1 rank is competitive and reasonable during Scrutiny amongst bidders |
| 2 | L2₹2.6 Cr+₹12.9 L (5.18%)Rejected-AOC | ₹2.6 Cr+₹12.9 L (5.18%) | L2 | Rejected-AOC Being not lowest |
| 3 | L3₹2.8 Cr+₹28.1 L (11.3%)Rejected-AOC 245A 7A 1 JAYANTIPUR GOKUL AWAS YOJNA SULEM SARAI PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹2.8 Cr+₹28.1 L (11.3%) | L3 | Rejected-AOC Being not lowest |
| 4 | L4₹2.9 Cr+₹41.4 L (16.6%)Rejected-AOC | ₹2.9 Cr+₹41.4 L (16.6%) | L4 | Rejected-AOC Being not lowest |
| 5 | L5₹3.2 Cr+₹67.3 L (27.0%)Rejected-AOC | ₹3.2 Cr+₹67.3 L (27.0%) | L5 | Rejected-AOC Being not lowest |
Tender Value
₹3.6 Cr
EMD Value
₹4.3 L
Closing Date
10 Feb 2024, 6:00 pmClosed
CWE
CWE AF BAMRAULI
WORK SERVICES FOR IMPROVEMENT TO CERTAIN SMQs PHASE II AT AF STN BAMRAULI
2023_MES_634067_1
87342/E8
Open Tender
Civil Works
Item Rate
273 days
BAMRAULI PRAYAGRAJ
Class A Category a i and other criteria as per Tender Doc and NIT
8 documents required · 8 mandatory
₹2,000
GE AF BAMRAULI
₹4.3 L
Yes
19 Mar 2024
22 Dec 2023
17 Feb 2024
22 Dec 2023
10 Feb 2024
27 Jan 2024
22 Dec 2023 - 5 Jan 2024
Amount
Demolition of PCC in ground floor and pavings n.exc 15 cm thickness below or above GL complete all as specified and directed.
Demolition to reinforced cement concrete of roofs, floors ( other than ground floors )beams staircases,landing,chajjas and similar suspended work complete all as specified and directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Dismantling of wrought iron or mild steel work any discription, provided in any positions complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof , floors, channels, kerbs, aprons etc,cement concrete of any description & in any position not otherwise specifically provided for.
Dismentling of floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
Dismantling of cast iron or renforced drain pipe 100mm/75mm dia of any description complete all as specified and directed.
Dismantling tanks water tank exc 250 but n exc 500 litre complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed
Taking up or down old steel tubing 15 mm dia including removing form site complete all as specified and directed.
Taking up or down old steel tubing 20 mm dia including removing form sitecomplete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
M & L for post construction Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M & L for post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed.
M& L for 25 mm Sand filling under floor including watering and consolidation. complete all as specified and directed.
M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) as in roof kerbs, Chajja of window/ventilator or mud stops, rounded or chamfered on top of chajja & side edges of surfaces upto the height of 7.00 mtr etc complete all as specified and directed. Note:- The rate is deemed to be inclusive of scaffolding/form work .
M&L for PCC 1:2:4 Type B-1using 20mm graded aggregate as in kerb stone in sides of inerlocking tiles including slightly rounded or chamfered angles and throating as complete all as specified and directed.
M&L for PCC 1:3:6 type C-0 using 12.5 mm granted stone aggregate as hold fast/filling in pressed steel frame complete all as specified and directed
M&L for PCC 1:3:6 type B-1using 20mm graded stone aggregate for providing cement concrete as levelling and roof kerbs or mud stops, including finishing the surface with grinder to receive the acrylic based water proofing material, rounded or chamfered on edges etc complete all as specified and directed.
M&L for 75 mm thick 1:4:8 type D-2 using 20mm graded stone aggregate as in sub base. complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded aggregate for plinth protection etc complete all as specified.
M& L for cement concrete type E-2 1:5:10 using 40mm graded stone aggregate as lean concrete in filling / Mass concrete complete all as specified and directed
M&L for cutting out cracks to v-section in existing roofs or terracing, cleaning, grouting with cement and sand slurry 1:3. complete all as specified and directed.
M&L for cutting grooves in brick wall 75mm wide and 65mm deep & shaping horizontal face of groove with cement . complete all as specified and directed.
Struking of existing PCC floor surface 5 to 10 mm deep picking,sweeping, clean and washing down with water to remove dust to receive cement mortar for tiling, complete all as specified and directed.
M&L for 60mm thick rubber moulded glosy finished inter locking paver block with grey cement and pigment of any type and shape the minium compressive strenth noy less then 350 kg/sqcm as approved by GE complete all as specified .
M&L for reinforced Cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in chajjas/roof projection/RCC railing repairs as in similar wk complete all as specified and directed.
M&L formwork to soffits and suspended slabs such as roof slabs floor slabs landings and similar work not exceeding 200mm thick (horizontal or sloping ) complete all as specified and directed.
S&F Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
M&L for Brickwork with subclass "B" bricks designation 100, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement complete all as specified and directed
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC @ 3% by wt of cement surfaces finished even and fair without using extra cement complete all as specified and directed
M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceiling complete all as specified and directed
M&L for machine cut Kota stone slab 18-20 mm thick in treads, landings of stair case over cement screed bed laid and jointed wilth grey cement slurry mixed with pigment to match the shade of the slab lincluding & grinding polishing over and including screedbed 20mm thick in cm 1:6 complete all as spd & directed.
M & L for machine cut Kota stone slab as in skirting, risers 16-18 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mirror polish granite finish including backing coat 10 mm thick in cm1:3 complete all as specified and directed.
M&L for 18-20mm thick granite work table rubbed and polished incuding moulding for wall lining /kitchen platform over 12mm thick cement mortar 1:3 thick and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for 18- 20mm thick granite Granite (of any type) work including moulding (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white ement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for full body double charged glazed vitrified tiles 'light coloured' tiles 8 to 9 mm thick mm thick joint free (square/ rectagular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile and laid over and inclduing 15mm thick screed bed or bedding layer in cement mortar1:6 complete all as specified and directed.
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick joint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6) complete all as specified and directed.
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick joint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm , in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6) complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 450x 300x6-7 mm thick joint less tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade tile over and inclduing 10mm thick rendering in CM (1:4) complete etc. (1st quality/Premium Quality).complete all as specified and directed.
Supply only liquid integral water proofing compund. Make Dr Fixit/ Pidipfoor/ LW+.
M&L for sunkan portion incl demolation of existing PCC,WC,P/S Trap and removing the material out side MD land.& (a) preparation of RCC surface of sunken slab (floor) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. NOTE:- 1. continuty with cementitious water treatmentbeyond sunken portion in toilet shall be maintaned
M&L for taking down cement plaster incl tile etc and removing the material out side MD land.& (a) preparation of RCC surface of sunken slab (side) by brushing and cleaning throughly with water (b) application of two coats of poly urethane based chemical treatment (as per manufracture instruction DR FIXIT/FOSROC/CICO/STP) (c) 15 mm thick (1:4) plaster over chemical coating incl finished even & smooth without using extra cement all as directed. NOTE:- 1. continuty with cementitious water treatmentbeyond sunken portion in toilet shall be maintaned
M&L for water treatment (floor/wall ) incl demolation of existing PCC / taking down cement plaster incl tile etc and removing the material out side MD land.& Cleaning with the wire brush to dry and apply one coat of URP and cement in ratio 1:1 @ 1liter per Sqm. After the drying of this process two coat of pidifin2K @ 01 liter on each coat min 4 hour gap is required and 15 mm thick rendering in CM 1:4 complete incl finished even & smooth without using extra cement all as directed.
S&F Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S&F Pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M & L for Solid PVC frame for door,kitchen cabinet,cupboard of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Second class hardwood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed.
S&F Second class hardwood Flush shutters 35mm thick, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style)both side prelam pvc sheet of decortive choice consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed.
S & F in repair 4mm thick Figured glass, pin head type in squares in n exc 0.5 sqm in each pane complete all as specified and directed.
S&F 1.25 mm thick mild steel plain black sheet in steel gates and similar work, cut to size, holes punched, including round headed screws and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded as required. complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0. complete all as spesified and directed .
M&L for preparing new plaster surfaces of ceiling and applying two coats of oil bond distemper over a 1.5 mm wall care putty complete all as specified and directed.
M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper over 1.5 mm wall care puttyr complete all as specified and directed
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over new plaster surfaces of walls complete all as specified and directed.
M&L for complete removal of existing treatment ceiling and applying two coats of oil bond distemper over a 1.5 mm wall care putty complete all as specified and directed.
M&L for complete removing existing treatment on walls and applying two coats of oil bound distemper over 1.5 mm wall care putty complete all as specified and directed .
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over including exterior wall care putty if 1.5 mm thick and priming coat of exteriour primer applied @0.90 litre/10 sqm over old plaster surfaces of walls complete all as specified and directed.
M&L for preparing new or previously untreated surfaces of wood or wood based materials of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed.
M & L for preparation of old wooden Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation and writing letters or figures (block, Roman, Italic or Indian) n.exc 30 CM heinght on plaster/concrete wall/path over coat of ACE as matching with existing pattern complete all as specified & directed
S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21 complete all as spesified and directed .
S&F 300 mm long Aluminium alloy with dia 16mm, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as spesified and directed .
S&F 250 mm long Aluminium alloy with dia 16mm, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy.complete all as spesified and directed .
S & F 125 mm long Extruded Aluminium alloy handles, fabricated type, anodised.complete all as spesified and directed .
S & F 200 mm long Aluminium anodised barrel tower bolts of extruded section.complete all as spesified and directed .
S&F in repair 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as spesified and directed .
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as spesified and directed .
S&F for rubber beading door seal 40x 5mm strip in bottom of door complete all as specified and directed.
S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters fixed with screws, solvent cement/adhesive and parliyament hinge as requred as per manufacturer instructions complete as per specifications and as directed by the Engineer-in-Charge. Note:-(i) Quoted rates deem to be include Cup board accessories ie fittings, fancy type handles,(125 mm / 150 mm ) self closing hinges / piano hinges with magnet, and locking arrangenet fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type). (ii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only.
S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet complete as per specifications and as directed by the Engineer-in-Charge. Note:- (i) Quoted rates deem to be include Cup board accessories ie fittings, fancy type handles,(125 mm / 150 mm ) self closing hinges / piano hinges with magnet, and locking arrangenet fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type). (ii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only.
S&F in repair fancy type decorated Stainless Steel curtain hanging rods 20 mm dia,and fixed to stainless steel bracket for hanging curtain complete all as specified and directed.
S&F Stainless Steel brackets having screw for tighting of curtain rod of 20mm dia for fixing of curtain rod, complete all as specified and directed.
S & F Stainless Steel bright color decorative corner/end cap for Curtain rod complete all as secified and directed.
S&F stainless steel peg set of six with base plate and fixed to wall/door with rawal pugs/ s/s screw all as specified and directed.
S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed .
S&F in repair CP vitreous china soap dish fancy type complete all as specifed and directed.
S&F in repair Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
S&F in repair brass chromium plated shower roses with swivel joints, 125 mm size in square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed.
S&F in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvc waste pipe, CP waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair 1mm thick stainless steel kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified and as approved by GE.
S&F Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with "P" or "S" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed as in repairs complete all as specified and as directed. Note:- Flushing cistern and flush pipe as required shall be measured and paid for under supply only separately
S &F health faucet, brass, chromium plated with pipe length 1200mm, washers, connections etc. complete all as specified and as directed.
S&F in repairs PVC flushing cistern 10 litre capacity valve less syphonic action type low level with and including dual flush ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
S & F in repair Vitreous China wash basin, flat back, size 450mmx300mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets.
S&F in repair Waste coupling of PTMT (half or full threaded) . (Minimum weight 2mm45gms/40mm 60 gms waste pipe of 40mm dia suitable for WHB, kitchen sink complete all as specifed and directed
S&F in repair angle cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed.
S&F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed.
S & F in repair wash basin mixter fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S& F brass CP wall mixer ( hot and cold ) non teliphonic fixed to wall for bathroom / kitchen complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed.
S&F rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed.
S & F ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed.
S & F in repair Stop valves/Gate valves 25 mm dia cast copper alloy,screwed down, high pressure with crutch or butterfly handel, screwed both ends for iron pipe or for unions and fixed.complete all as specified and directed.
Refixing old 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
Refixing old 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
S&F 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors including cutting chases in wall or floor and making good and taking up or down old steel tubing complete all as specified and directed.
S&F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors including cutting chases in wall or floor and making good and taking up or down old steel tubing complete all as specified and directed
S&F Cast iron soil, waste and vent pipe 100 mm dia in any length with or without ear, with cement joint, laid in trenches or in wall complete all as specified.
Fixing only old serviceable/new Cast iron soil, waste and vent pipe 100 mm dia in any length with or without ear, with cement joint, laid in trenches or in wall complete all as specified.
S&F 100 mm cast iron sanitary connection socket to fit wc out let complete all as specified and directed.
S&F 100 mm cast iron sanitary connection S branch with branch 370 to 450 mm long excluding joint complete all as specified and directed.
S & F in repair of 110 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
S & F in repair of 75 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
S&F PVC SWR (110) bends any radius comlete all as specified and directed.
S&F 75 mm PVC (SWR) junction single, (singl T ) (equal or unequal ), ordinary or inverted ( spigot or socket type ) or with paralle oval access doors branches .complete all as specified and directed.
S& F 110 mm PVC (SWR) vent cowl. Complete all as specified and directed.
S&F 75mm PVC (SWR)floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified directed.
S&F stack clamps out of 50mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 100mm complet all as specified and directed.
S&F stack clamps out of 50mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 75 mm complet all as specified and directed.
M&L for rendering or bedding layer 15mm thick in cement mortar (1:3) over concrete surfaces of roof, mixed with WPC 2% wt of cement inclduing finishing surfaces even and fair without using extra cement complete all as specified and directed. (Note: WPC will be measured and paid separately).
M&L for preparation of new surface and applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed.
M&L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer.complete all as specified and directed.
M&L for rendering or bedding layer 15mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with linesed oil @ 3% wt of cement inclduing finishing surfaces even and fair without using extra cement inclusive linesed oil complete all as specified and directed.
M&L for 300mmX300mm, 8 to 9 mm thick size roof cool tile to reduce room temperature, slip risistance, white in colour, having properties like water absorption max 3.3%, breaking strength 1000N, moisture expansion maximum 3% scratch hardness 4 minimum, thermal shock reisistance 10 cycles, min impact resistance 0.55 minimum, tiles laid on cement mortar 1:6 and pointing in CM 1:3 over 15 mm screed bed complete all as specified and directed. Make:-ISI marked or conforming to relevant IS as approved by GE
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down old and u/s light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size.
Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as directed.
Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc all as directed.
Disconnecting and taking down old serviceable Energy Meters of any type / capacity after noting down the reading from meter etc. and marking the Quarter No on each meter with permanent marker pen and depositing in MES store for safe custody and writing MES No complete and re-fixing /reconnection in new meter cabinet all as specified and as directed.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with two run 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly for One light, fan, bell point controlled by one switch and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed . Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with two run of 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly for One 3 pin switch socket outlet point 5 Amps on same board with other switch and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:- Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with two run of 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly for One light point controlled by two Nos two way switch and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed. Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with two run of 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly for One 5 Amps socket outlet on independent board and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed. Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with two run of 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly for for one 3 pin socket outlet, 15 amp independent and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with two run of 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for Power socket 15 Amps on independent board.
M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge.
M&L for Modular switch, 6 Amps, one module, two way complete all as specified and directed.
Supply and fixing Modular socket outlet 2 in 1, 5 pin, 6 Amps flush type white finish complete all as specified and as directed.
M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed
M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one way, complete as specified and directed
S & F ceiling rose surface backlite 65x50mm 3 terminals complete.
Supply and fixing lamp holder PVC body with back plate complete all as specified and directed.
S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed.
M&L for Modular bell push 5 Amps 230 V, AC circuit complete all as specified and directed.
M&L for call bell ding dong 230 V AC circuit complete all as specified and directed
Supply and fixing 4 Module Gang box including Modular socket outlet 16 Amps for AC, 240 Volts flush type white finish including plug top 20 Amps with modular piano type switch 20 Amps and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply and fixing LED Light fitting 1x12 watt bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing in replacement of GI Pipe bend to shape 1.5 mtr (32/40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and directed.
Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall dimension 1200mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :- a) Four pole MCCB, 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No. b) Copper Bus Bar of size 25mm x 3mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.
c) MCB SPN 25 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters) d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights) e) Analog time switch 16 Amp-01 No f) LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos. g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos h) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up, 24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light). j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
Supply and fixing factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
Supply and fixing MCB single pole 240 volt 'B' curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one.
Supply and fixing MCB single pole & neutral 240 volt 'C' curve 10 KA 25 to 32 Amps complete all as specified and directed .
M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
M&L for taking down carefully existing ceiling fan/exhaust fan from site before B/R repair work, keeping in safe custody in store for greasing / oiling of ball bearings / bushes and making it for smooth and noise free operation and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities' and re-fixing after providing new fan clamp, nuts/bolts, washers, down rod as required and provision of 3 core copper flexible cable of size 1.0 Sqmm from ceiling rose to fan connector complete with writing of MES No. on the fan surface all as specified and directed.
Supply and fix exhaust fan steel body, heavy duty, double ball bearing, Copper wounded complete with louvers shutter, 230 volt AC, single phase, 50 Hz, 1400 RPM, 300 mm sweep with blades, steel frame complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed.
M&L for cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface complete all as directed by Engr-in charge.
Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and as directed. Note:- The rate quoted is inclusive of Remote and Remote cell.
M & L for taking down carefully existing geyser of any type and cap from site before B/R repair work, keeping in safe custody in store for servicing and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities, writing of MES No. and re-fixing with new hot and cold water connection as required incl provision of 3 core copper flexible cable of size 4 Sqmm complete with 15 Amps 3-pin plug top all as specified and directed.
Supply and fixing water heater storage vertical type, puff insulation type of 25 ltrs capacity and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement and including writing MES No complete all as specified and directed.
Material, labour jointing & testing XLPE insulated armoured heavy duty electric cable with standard aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core including making connection with suitable size of cable gland, aluminium lugs etc complete including taking down old U/S cable all as specified and directed.
Excavation in trenches in soft/loose soil n. exc 1.5 M wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected
Supplying, laying sub class 'B' bricks designation 75 old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
Supply & Fixing in replacement galvanised iron tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed
Taking out old unserviceable earthing and M&L for new earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B-1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 8 mm dia TMT bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No3 of SSR Part-I 2009 complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M/s NSA Engineering Corporation
R.K.ASSOCIATES
Perfect Enterprises
M/s DHARAM VIR GHAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .