| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC Ok | |
| 2 | L2₹26.5 L+₹66,500 (2.57%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹27.6 L+₹1.8 L (6.84%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹28.2 L+₹2.4 L (9.18%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹28.6 L+₹2.8 L (10.8%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹48.9 L
EMD Value
₹98,000
Closing Date
8 Dec 2021, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT OF UNSERVICEABLE POINT WIRING, FITTINGS/ FIXTURES, DB, MCBS FOR MED I, II, III, IV AND SURG I WARD AT ADM BLOCK UNDER GE (E/M) BHDC-10
2021_MES_488619_1
GE/BH-56/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹98,000
Yes
2 Apr 2022
16 Nov 2021
10 Dec 2021
16 Nov 2021
8 Dec 2021
1 Dec 2021
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc shall be measured and paid separately) and making good disturbed surfaces of wall floor etc complete all as specified and as directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn through and including Surface/concealed, rigid non-metallic PVC Conduit of minimum 25mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 2.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 2.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 2.00 here in before but for one light point controlled by two Nos, two way switches complete all as specified and as directed.
All as per item No. 2.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No.2.00 here in before but point wiring with 4 Sqmm, multistranded, copper conductor cable, for AC point on independent board with 4 Sqmm size earth conductor complete all as specified and as directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn through and including PVC Casing Caping with all fittings such as bend, tee, junction boxes, elbows etc, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 8.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 8.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 8.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No. 8.00 here in before but point wiring with 4 Sqmm, multistranded, copper conductor cable, for AC point on independent board with 4 Sqmm size earth conductor complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 1 or 2 module complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 1 or 2 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 12 modules complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular bell push, 6 Amp, 1 Module complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 16 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement Modular Fan step regulator, 120W - 2 module including connecting complete all as specified and as directed.
S&F in replacement modular switch, 2 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement Bell ding dong, AC, 230 Volts, fixed in position & connecting complete all as specified and as directed.
S&F in repair modular blanking plate, 1 Module complete all as specified and as directed.
S&F in repair PVC T-COVER complete all as specified and as directed.
S&F in replacement sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed.
S & F in repair MCCB 415 V, 100 Amps, 35 KA, 4 Pole complete all as specified and as directed.
S & F in repair MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and as directed.
S & F in repair MCB SPN, 240 Volts, 40 Amps, C Curve complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 10 Amps, C Curve complete all as specified and directed.
S & F in repair MCB SP 240 Volts, 16 Amps, C Curve complete all as specified and directed.
S & F in repair MCB SP 240 Volts, 25 Amps, C Curve complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 32 Amps, C Curve complete all as specified and directed.
S & F in repair distribution board, double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and as directed.
S & F in repair distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and as directed.
S&F in replacement sub main wiring with 2 runs of 2.5 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 2.5 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note: Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length.
S&F in replacement sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length.
S&F in replacement sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 6 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length.
S&F in replacement sub main wiring with 4 runs of 10 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 10 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Four run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length.
S&F in repair load line, distribution board, double door type, TPN, vertical, 8 way, suitable for accommodating up to 125 Amps MCCB with incoming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 47 or equivalent model of Make mentioned in PS.
S&F in repair load line, distribution board, double door type, TPN, vertical, 12 way, suitable for accommodating up to 125 Amps MCCB with incoming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 48 or equivalent model of Make mentioned in PS.
Supplying, installation, testing & Commissioning of recessed Type Full window opal Diffuser Ultra modern slim LED Panel 2x2 of not more than 36W, size 595X595mm (Nominal) suitable for Existing false ceiling with CRCA powder coated White Housing & Isolated Electronic Driver with Output Short-circuit protection, Surge Voltage protection min 3KV, safety & performance test as per IS:15885 Part 2/Sec 13. Total system Lumen not less than 4200 in Cool day Light(5700K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours. Complete with all accessories as required with connections. All above mentioned Specs will be verified through NABL Certified LM79 & LM80 Report before supply of LED Fixture onsite. Make model no :-Havells STRATO 2X2PLR36WLED857MOD + LEDDRIVER36V36WS or equivalent model of make/ Philps/CG or mentioned in PS.
Supply, fixing and connecting in replacement Surface/Wall Mounted, 20 Watt, integrated LED, 4 feet Fitting, with polycarbonate housing & opal diffuser finish, Integral electronic driver with Output short circuit protection, Surge Voltage Protection of minimum 3 KV and Safety test as per IS15885 Part 2/ Sec 13. Total system Lumen shall be 2000 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy 100 Lm/w, THD(%) < 20, LED with Average life of 50000 Burning hours. Complete with all accessories as required complete all as specified and as directed. Make - Havells Cat part No - LUMILINEBS20WLED865SPCWH or equivalent model of Make mentioned in PS.
Supply, fixing and connecting in replacement Surface/Wall Mounted, 9 Watt, integrated LED, 2 feet Fitting with Epoxy powder coated white polycarbonate channel housing. Total system Lumen of 9W LED shall be 800 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>100 Lm/w, THD(%) < 20, Complete with all accessories as required complete all as specified and as directed. Make - Havells Cat part No -LUMILINEBS9WLED865SPCWH or equivalent model of Make mentioned in PS.
S&F in repair PVC casing caping, medium grade, size 25 X 16 mm, including necessary accessories (Tee, elbow etc) & clamp, screw, rowel plug etc. complete all as specified and as directed.
S&F in repair Rigid, non-metallic, PVC conduit, medium grade, 25mm bore, including all fittings such as tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
S&F in repair recess mounting, 15 Watt, slim eco backlit LED panel, round polycarbonate housing and PS diffuser, Inbuilt driver, efficacy 100 Lm/W, CRI>80, Beam Angle 120 Degree, with all accessories as required complete all as specified and as directed. Make - Polycab, Cat Part No. LDO0120045 or equivalent Model of Make mentioned in PS.
S&F in repair recess mounting, 20 Watt, slim eco backlit LED panel, round polycarbonate housing and PS diffuser, Inbuilt driver, efficacy 100 Lm/W, CRI>80, Beam Angle 120 Degree, with all accessories as required complete all as specified and as directed. Make - Polycab with cat part no. LDO0120051 or equivalent Model of Make mentioned in PS.
S&F in repair Surface/ Wall Mounted, LED Light Fitting, 15 Watt, Round shape, slim down light, white Complete with all accessories as required complete all as specified and as directed. Make - C & S Cat Part No. LTCRSUR15HPLEDRND/W or equivalent Model of Make mentioned in PS.
S&F in repair Surface/ Wall Mounted, LED Light Fitting, 17 Watt, Cool white with all accessories as required complete all as specified and as directed. Make - Philips Cat Part No 48027 ULTRON SLIM or equivalent Model of Make mentioned in PS.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Building at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
SANJEEV ENTERPRISES
M/S Rohit Enterprises
M/s Sohanil Construction
Saini Enterprises
M/s Adhikari construction co.
POONAM ENTERPRISES
R R Associates
RUCHIKA ENGG.WORKS
Surjit and Sons
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .