Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-Finance | L1 | Accepted-Finance Being Lowest Tenderer | |
| 2 | L2₹49.6 L+₹91,968.75 (1.89%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹50.1 L+₹1.5 L (3.01%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹46.8 L
EMD Value
₹93,600
Closing Date
6 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8493A PROVISION OF 07 ACs AGAINST BER AT CQAE WS MUMBAI, INSTALLATION OF 03 EXPLOSION PROOF LIGHTING FOR POL STORE AND INSTALLATION OF 02 DE HUMIDIFIERS IN STORE AT INWTC MUMBAI SPECIAL REPAIR REPLACEMENT OF OLD CONVENTIONAL LIGHT FITTINGS TO ENERGY
2023_MES_580265_1
8493/A/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹93,600
Yes
10 Mar 2023
10 Feb 2023
8 Mar 2023
14 Feb 2023
6 Mar 2023
15 Feb 2023
10 Feb 2023 - 14 Feb 2023
Amount
Supply, install, Test and commissioning wall mounted inverter type Split type AC 1.5 TR capacity units indoor/outdoor complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating/ ISEER 4.5 or avove complete as directed incl making holes in wall Note : (a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted.Make : Daikin/Hitachi/LG
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240V all as directed incl taking down old existing unsv enclosure.
M&L for submain wiring with 2 runs of 4 sqmm and one run of 4 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing & caping not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up all as specified and directed.
Supply, fixing and clamping , jointing copper tubing for suction line and for liquid discharge line insulated with suitable insulation material including making hole in wall for passing through and making good disturbed surface complete.
Material and labour for point wiring 1.5 sq mm FRLS Copper cable 1100 volt grade drawn in and including stove enamelled steel ERW conduit not less than 19mm dia including spacers, saddles, screws etc & 1.5 sqmm PVC insulated copper earth wire including 2mm thick MS sheet fabricated terminal box for fixing switch with 3mm thick hylam sheet top cover all as specified.
S&F Flame Proof Switch rotary type with termination box in LM6 single pole 250 V, incl. all connected accessories all as specified.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S&F Flame Proof Junction Box with Plain cover 3/4" ET Dia 80 CAT NO- JB/OA/104 of Sudhir or it's equivalent from Baliga/Shyaam
S&F steel sheet enclosure double door type for MCB DB flame proof SPN 4 way, 240 volts AC factory made, suitable for housing MCB SPN and SP along with 200 Amps copper bus bar complete all as specified and directed alongwith all connected accessories.
MCB SP 6 - 32 Amps, 10 KA Rupturing capacity
MCB SPN 32 Amps, 10 KA Rupturing capacity
S & F Portable De-humidifiers Capacity 1.5 TR Moisture Removal capacity of 30 Deg 4.5 Ltrs, Air Quantity 600 CFM and filtration 20 Micron complete including connecting up all as specified and directed.
M&L point wiring complete with 2.5Sq. mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC moulded box/ hylem sheet ISI marked fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 2.5Sq. mm as earth continuity conductor connected to common earth dolly for 15 amp swich socket on independant board complete including modular box with cover plate frame in any module complete complete fixed on wall for fixing the switches, switch, socket all as specified. Note: (a) Colour coding shall be followed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Gloster (c) Make of PVC casing capping/Conduit :- Precision/ pesto plast / National/Plaza
S & F modular switch 1 way 16A,1 module all as specified and directed by EIC. Make: Anchor/Roma/Legrand/C&S/Goldmedal
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed by EIC. Anchor/Roma/Legrand/C&S/Goldmedal
S &F in repair Ceiling light 36 WATT-2ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel all as directed and specified Make - /Bajaj / Philips/Havells/Shakti
Supply & Fix LED Slim down light not less than 12W LED 6 white/ warm white LED Round Recess PDC Aluminium Housing Downlights,not less than 5700K light all as specified directed. Make -Bajaj / Philips/Havells/Shakti
Supply, install, Test and commissioning Floor mounted Tower type AC 3.0 TR capacity units indoor/outdoor complete with cordless remote control unit, 410-415 volt, 50Hz, three phase fitted with high quality rotary compressor and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating complete as directed. Location: 04 CONF ROOM 02 BOARD ROOM Note : (a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted.Make : Daikin/Hitachi/LG/Blue star
S & F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of 63Amps capacity
M&L for submain wiring with 4 runs of 6 sqmm and two run of 6 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing & caping not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up all as specified and directed.
Supplying installation, Testing & Commissioning of Microprocessor based 2 loop capacity , Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of intigraton with BMS System.(UL/EN Approved) as per tender specificaiton.Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode as per tender specificaiton. Make : Honeywell/Siemens/Bosch
LANDLINE FIRE ALARM AUTO DIALER WITH sms and Memory Available To Store 10 Phone Numbers dialling facility to reach the fire brigade to get the intimation about the location of the area Builtin Emergency Speech Dialer with 8 Numbers & 1/ 2 Messages,NO/NC contacts for both fire and fault, Automatic changeover arrangement to standby supply with battery charger with low battery indication,Fault/ failure indication such as MAINS FAIL, short, open, Battery FAIL etc,Micro-Controller Based System,Both Dialling Modes Can Be Used (Pulse/Tone),Recorded Message Playback Speaker Provision Available. Make : Agni/Ravel/Atss
Supply, Installation, testing and commissioning addressable Manual call point(Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwritters laboratories listed, semi flush type complete all as specified and directed. Make : Honeywell/Siemens/Bosch
Supplying installation, Testing & Commissioning of Addressable monitor modules for Sprinkler Flow Switch and Door Holders as per tender specification. Make : Honeywell/Bosch/Siemens
Supply fix and commissioning and test of addressable electronic hooter with built in amplifier unit with two tone generator of 100 meter range complete all as specified and directed. Make : Honeywell/Siemens/Bosch
Supplying installation, Testing & Commissioning of Analog addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC(Above Celling & below celling .) as per tender specificaiton all as specified and directed. Make : Honeywell/Bosch/Siemens
Supplying installation, Testing & Commissioning of Conventional Beam detector complete as required for hall & indoor open area. As per tender specificaiton. Make : Honeywell/Siemens/Siemens
Supplying installation, Testing & Commissioning of Addressable control modules for AHU, Access control Integration & stairs Pressurization Fan Hooters / Sounders / Strobes etc.as per tender specificaiton. Make : Honeywell/Siemens/Siemens
Supply and fix fault isolator module with automatic resetting arrangement complete all as specified and directed. Make : Honeywell/Edward/Bosch/Siemens
Supply & laying PVC FRLS armoured cable 1.5sq mm solid copper conductor 2 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as directed. Make of wire : Polycab/ Havells/ Gloster Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. Make; Polycab/ KEI/RR.
Supplying installation, Testing & Commissioning of Response indicator for Above celling detectors & Cabin Detectors Make : Honeywell/Bosch/Siemens
Supplying installation, Testing & Commissioning of The GUI based main network software must be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’locations. The GUI software shall be located in control room in one of the blocks and shall monitor all the blocks panel connected with each other along with workstation as per tender specificaiton.
Supply, install, Test and commissioning of casettte type AC 5 Star/ ISEER 4.5 or above inverter 04 Ton Capacity units Indoor/ outdoor complete with cordless remote control unit twin rotary compressor, single phase/ three phase Note : (a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted.Make : Daikin/Hitachi/LG/Blue star
S & F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of 63Amps caapcity .
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 35sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply , fixing, testing of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note - Back-fill compound shall not be mixed with any soil while pouring in the bore hole.
S&F of double door type vertical type TPN DB 6 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507746/Seimens/C&S. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
Supply and fix MCCB 4pole 250A, 16KA
Supply and fix MCB 4 pole , 100A
Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars, etc
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built insetting in CM (1:6)
M & L for brick work with sub class 'B' bricks (old Size) straight or curved on plan exc 6 m mean radius and built in CM (1:6)but half brick thick wall built in CM 1:4.
Taking down chowkats or frame with shutter ( without taking off shutter from frame), n exc 1.5 sqm each complete all as specified.
Taking down chowkats or frame with shutter ( without taking off shutter from frame) exc 1.5 sqm but n exc 4 Sqm each complete all as specified.
S&F powder coated aluminium of various section as required for doors, window & partion etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant etc all as specified and as directed by Engr- in- charge. Make : JINDAL/HINDALCO/INDALCO (i) The rated quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as hinges, handles, locking arrangemnt etc as required, which shall not be measured for arriving the weight. (ii) Items shall be as per weight of aluminium section. (iii) The rated shall be inclusive of complete packing with silicon gel areound contacting surfaces of aluminium work and including matching the existing surface area.
S & F in repairs for aluminium anodised Deco grill 7.5 mm size DG-102, fixed to F/H frames, 1.5mm th, bar size 6.2mm and 7.5mm thick in required sizescomplete all as specified and as directed by Engr-in-Charge.
S&F Medium density fibre board, 12 mm thick exterior grade, fixed to timber/Aluminium framework with screws. All as specified and directed.
M&L for 4 mm thick plain glass sheets ordinary quality in squares exc 0.5sqm each pane fixed with rubber beading for aluminium windows/doors etc all as specified and directed.
Taking down cement plaster on brick / surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water etc complete.
M&L for Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified.
M&L for Newly plastered ceiling surfaces and applying two coat of oil bound distemper over a coat 1 to 2 mm thick wall care putty (JK/Birla ) and primer complete all as specified and directed.
Removing building material exc. 1.50 km but n exc. 5 km and depositing where directed
S&F in false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction. (Make : Everest or equvalent as approved by GE)
M&L for POP false ceiling using 600 x 900 x 12 mm thick plaster of paris with gypsum binder sheet decorative type and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work main joist of size 50 x 25 mm spaced at 750 mm centre, secondary joist of size 75x20 mm fixed to main joists spaced t 900 mm suspended to roof members using 25 x 25 x 2 mm GI angles and fasteners @ 1.2 m C/C including decorative design/pattern all as specified and directed Engr-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .