Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.5 L+₹1.4 L (4.98%)Rejected-Finance 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹30.8 L+₹2.7 L (9.78%)Rejected-Finance 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹32.0 L+₹3.9 L (13.9%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹32.3 L+₹4.3 L (15.3%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
31 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
PROVISION OF CERTAIN BR AND EM SANCTIONED WORKS AT AFS SITE R UNDER GE AF THANE
2022_MES_504174_1
8154/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹68,000
Yes
7 Jun 2022
28 Feb 2022
1 Apr 2022
28 Feb 2022
31 Mar 2022
15 Mar 2022
28 Feb 2022 - 15 Mar 2022
60 days
Amount
Demolition of cement concrete (un reinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) ,complete all as specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles ,complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. ,complete all as specified and as directed by Engineer-in-charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sq. m each.Complete all as specified and as directed by Engineer-In-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m n.exc 4 sqm each and remove to store ,Complete all as specified and as directed by Engineer-in-Charge.
S&F 35mm thick IInd class HW rail and style plain framed panelled factory made shutter (Two panel) with lock rail and panel of 9mm BWP,commercial ply or 12mm veneered particle beard with commercial veneering on both faces. The size of rail and stile as per IS :1003 (Part-I) kiln and chemically pressure treated ,Complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for 35mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or reounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chawkats ,Complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Bands, straps,supports or stays for rainwater pipes, hold fasts etc complete all as specified and conforming to Fe-290 Gde-E-165 etc.,Complete all as specified and as directed by Engineer-in-Charge.
M&L for Cutting holes in brick walls exc half bricks but nexc one brick built in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cm (1:3) or cement concrete (1:2:4) type B1 as required ,Complete all as specified and as directed by Engineer-in-Charge.
S & F Aluminium anodised door handles 150 mm long ,Complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 10mm thick (1:6) cement plaster on fair faces of brick work or concrete surfaces even and smooth without using extra cement ,Complete all as specified and as directed by Engineer-in-Charge.
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately)
M&L for rendering 5mm thick (1:3) cement plaster newly plastered surface on ceilling or brick work or concrete surfaces even and smooth without using extra cement complete all as specified and as directed
M&L preparation of newly plasterd surface of ceilling of concrete or brick surfaces and applying two coat of white wash complete all as specified
M&L preparation of old plasterd surface of ceilling of concrete or brick surfaces and applying two coat of white wash ,Complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of newly steel surface of any description over 10cm width or girth not otherwisw described two coat of synthetic enamel paint over a coat of red oxide primer ,complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of newly wooden surfaces surface of any description over 10cm width or girth not otherwisw described two coat of synthetic enamel paint over a coat of red oxide primer ,complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing bitumen tarfelt including coba,plaster of any description over the surface of roof, terracess including flashings and junctions of parapete/curbwalls etc and removing of the rubbish to a distance exceding 500m but nexc 1.00km and depositing where directed ,complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 B-0 using 12.5mm graded stone aggregate as in filleting and benching slightly rounded etc including necessary formwork ,complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 B-0 25mm thick using 12.5mm graded stone aggregate as in padding concrete on roof slab ,complete all as specified and as directed by Engineer-in-Charge.
Supply only Integral water proofing compound ,complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15mm thick on CM (1:3) on concrete roof top and chajjas surface finished even and smooth to get uniform level surface for laying of membrane treatement with using water proofing compound ,complete all as specified and as directed by Engineer-in-Charge. (Note : Water Proofing compound shall be measured seperately under relevent item of Sch A)
M&L for APP modified roof treatment over existing RCC roof ,complete all as specified and as directed by Engineer -in-charge and as specified here under :- (a) Applying bitumen primer @ 0.40 lit/sqm with density of 0.87 kg/lit at 25 degree C on the prepared dry roof surface. (b) Laying 3 mm thick APP membrane including aluminium layer on top, weight not less than 3.50 kg per sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be got done through an authorised applicator of manufacturer of APP membarane (c ) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer all as specified.
M&L Brushing neat cement slurry with 3kg of cement per sqm ,complete all as specified and as directed by Engineer-in-Charge.
S & F Rotational moulded polyethylene water storage tanks,triple layered, 1000 Lit Capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I ,complete all as specified and as directed by Engineer -in-charge.
S & F Rotational moulded polyethylene water storage tanks, triple layered, 500 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I ,complete all as specified and as directed by Engineer -in-charge.
S&F Gun-metal, globe or gate valves,bore dia of pipe in 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed ,complete all as specified and as directed by Engineer -in-charge.
S&F Gun-metal, globe or gate valves,bore dia of pipe in 15 mm, with iron wheel head, screwed both ends for iron pipe and fixed ,complete all as specified and as directed by Engineer -in-charge
S&F Ball valves 20 mm high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) ,complete all as specified and as directed by Engineer -in-charge
M&L for Removal of existing treatment on wall and applying 2 coats of Dr Fixit Raincoat exterior acrylic elastomeric coating (Note:- Application of coating shall be along seepage/damp portion of bldgs only)
Taking up or down steel tubing & connections 15mm, including cleaning for refixing or removal to storage / away from site suitable for following bore of pipie complete all as directed & specified by Engineer-In-charge.
S&F tubes medium grade 15mm, galvanized with all fittings and fixed complete wall and celings or laid in floors , for the following bore of tubes , complete all as specified as directed by Enginer in charge.
Taking up or down steel tubing & connections for 20mm bore dia, including cleaning for refixing or removal to storage / away from site suitable for following bore of pipie complete all as directed & specified by Engineer-In-charge
S&F tubes medium grade 20mm, galvanized with all fittings and fixed complete o wall and celings or laid in floors , for the following bore of tubes , complete all as specified as directed by enginer in charge
S&F PVC (SWR) pipes, 110 mm dia ,single socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors
Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises
M&L Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in CM 1:3 Complete all as specified and directed
M&L Non skid ceramic coloured tile 7 to 8 mm thick area of each tile exc 0.18 sqm but not exceeding 0.38 sqm in floor set and jointed in neat cement slurry and point in white or coloured cement to match colored tile over 15 mm screed in CM 1:4.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F in repair 15mm Stop valves, fancy type, chromium plated cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed by Engr in Charge.
M&L for Cutting existing 20mm steel tubing for alterations or additions in any position without taking down (Each cut measured)
S&F in repairs wash down water closet (pedestal pattern) Complete(excl flushing cistern or flush pipe) all as specified and directed by Engr in Charge.
S&F in repairs vitreous china sqautiing orrisa pattern size 580x440 mm white with integral foot rest (excl flushing cistern or flush pipe) all as specified and directed by Engr in Charge.
S&F in repairs PVC High/Low level flushing cistern 10 litrescapacity including all fittings i.e float valve, syphon, flushpipe,brackets and flush pipes to pedestal pan, including all joints all as specified and directed by Engr in Charge.
S&F in repairs viterious china wash basin white flat back size550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings all as specified and directed by Engr in Charge.
S&F PVC High/Low level flushing cistern 10 litrescapacity including all fittings i.e float valve, syphon, flushpipe,brackets and flush pipes to pedestal pan, including all joints all as specified and directed by Engr in Charge.
S&F viterious china wash basin white flat back size550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings all as specified and directed by Engr in Charge.
S & F in repairs bib taps CP Brass fancy type long shank with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed by Engr in Charge.
S & F bib taps CP Brass fancy type long shank with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed by Engr in Charge.
M&L PVC(SWR) floor trap,plain with gratings incl jointing with solvent cement 75mm dia outlet
S&F Grating doom 100 mm dia of PTMT (Minimum weight 25gms)
S & F in repairs PVC connections 15mm dia with brass nut on both ends and washers 450mm long all as specified and directed by Engr in Charge.
S&F aluminium anodized barrel tower bolt extruded section and fixed 200mm long
S&F extruded aluminium alloy handles 150mm fabricated type, anodised complete all as specifed
S&F IInd class hard wood plain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed Make-classic/Shalimar etc equivalent ISI Marked.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed chromium plate fancy type
S&F mild steel cold rolled medium weight butt hinges, of size 100mm complete all as specified
Demolition of cement concrete ( reinforced)Concrete in in roof,beams ,landing ,chajjas, lintel etc complete all as specified ground floors and pavings n exc 15 cm thickness (below or above ground level)
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for reinforced cement concrete type B0 (1:2:4) ( 12.5 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete ball as specified and as directed
Ditto as item No. 69.00 above but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces
M&L preparation of newly plasterd surface of concrete or brick surfaces of two coat of distumper oil emulsion over a coat of primer complete all as specified
M&L preparation of old plasterd surface of concrete or brick surfaces of two coat of distumper oil emulsion over a coat of primer complete all as specified
M&L powder coated aluminium Door/ window/ sliding window / Ventilator / partition frames and shutters using standard aluminium powder coated sections including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, anodised aluminium fittings suitable Nylon gasket, nylon rollers, maruthi locks, handles, concealed star lock, aluminium F channel for fixing aluminium grill and all necessary fittings and fixtures etc all as specified etc complete of standard sections and fixing to cudappa stone/granite stone with necessary bolts/screws complete directed.
S&F Anodised aluminium door shutters ,powder coating of any colour (thickness of powder coating not less than 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&F aluminium anodized grill of 4.75 x 7.75 mm, size of opening 10cm, size of mesh RG 103 (as per royal grill) with aluminium channel `F' angle 20mmx15mm fixed to aluminium frame work all as directed.
S&F stainless steel wire mesh of 0.36mm dia of wire and average width of aperture 1.40mm & fixed with tinted tacks of galvanised over staples ,complete all as specified and directed by Engr-in-charge.
S&F sheet glass 4.00mm thick, ordinary quality and glazing n.exc 0.50Sqm in each pane , complete all as specified and directed by Engr-in-charge.
S&F Figured glass 4.00 mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Aluminium anodised, barrel tower bolts of extruded section and fixed length of tower bolt 200mm complete all as specified
S& F aluminium Mortice lock, type 2 Levers vertical type, size 100 mm complete all as specified
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 150mm complete all as specified
M&L Sheet glass 5.5mm thickness , ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed
S&F in repair Door closer aluminium ( extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
M&L for Pre-cast cement concrete block masonry type C1 (1:3:6) (20 mm graded aggregate) set in 1:4 Cement mortar with solid blocks, exc. 10cm in width and setting in mortar, complete
S&F in repair Chromium plated shower roses 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed by Engr-in-charge
S&F in repair brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges
S&F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors
M&L for Removal of existing concrete along with loose damaged and cracked concrete/cover concrete at all specified locations up to beyond the corroded steel reinforcements to a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement and removal and disposal of debris. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. Depth of chipping will vary from 50mm to 150mm complete with labor, tools, scaffoldings machinery etc. as directed by Engineer-in-charge. The edges of the repair locations should be saw cut to a depth of at least 10 mm to avoid featheredging and to provide a square edge. Removal of dust, loose particles from concrete surface manually by wire brush, mechanically or any other means to obtain a sound surface over areas other than above.
M&L for The loosely bonded concrete of the R.C.C Deckslab, Beam / Girder and piles shall be chipped out using the mechanical cutter exposing the rebars.Apply FOSROC Rebakleens RR- Rust Remover using small brush and allow to react it for 16-24 hrs. Befoe applying protective coating,the surface should be wire brushed and thoroughly cleaned for for dust with dry cloth.
M&L for Providing and applying two coats of Fosroc Nitozinc Primer - two component, zinc rich epoxy, anti-corrosive protective coating. Coating shall be brush applied to the exposed and cleaned rebars with an interval of 45minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours.
M&L for Providing and applying 50 mm thk Renderoc SP 40 - Polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar. mixing of Renderoc SP 40 with recommended qty. of water using slow speed drill fitted with mixing paddle and apply the same to prepared surface. Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface, Cured Renderoc SP 40 shall exhibit compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength (BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge.
M&L for Holes of dia 16mm and depth 100 mm are drilled @ a spacing of 1mtr c/c both ways on the existing structure . The loose cementitious particles are removed using a air blower to clean the holes. Shear Keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using Fosroc’s Lokfix E55S - Vinyl Ester Resin Anchor Grout.
M&L for The concrete substrate is thoroughly cleaned once again using wire brush One liberal coat of Make Fosroc Nitobond EP- two component Epoxy bonding agent shall be brush applied to the parent concrete.
M&L for Providing and applying 50 mm thick microconcrete along with proper tight leak proof shuttering make : Fosroc Renderoc RG SPL- Polymer modified cementitious , low permeable, free flow , non shrink, self compacting microconcrete of grade M70 as per recommended w/c ratio and pouring as per the designed thickness.
M&L for Rough excavation in soft/loose soil n exc 1.5 m deep and getting out complete all as specified and directed.
Excavation over areas in soft/loose soil n exc 1.5 m deep and getting out complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth in soft/loose soil for foundation and getting out complete all as specified and directed.
M & L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregates as in foundation filling, mass concrete complete all as specified.
M & L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone agg complete all as specified.
M & L for 75 mm thick PCC 1:2:4 type B2 using 40 mm graded crushed stone agg complete all as specified.
M & L for cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregates as in foundation filling, mass concrete complete all as specified.
S & F 38 mm wide plastic deviding strips complete all as specified.
S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FR PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drwan through PVC conduit of suitable size heavy grade ISI marked including necessary conduit accessories, sunken type pressed steel terminal boxes with plastic laminated sheet of approved shade 3mm thick including 1.5 mm PVC insulated flame retardant copper conductor as in continious earth wire for:
One Light point controlled by one switch .
One ceiling / Exhaust fan point controlled by one switch
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto-All as per item No 108.00 above but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board
Supply & Fix for switch piano flush button single pole one way 5 Amps, 250 V Make: Ancor/Havells/Kinjal
Supply and Fix switch socket combination 2 in 1, 5 pin, 5 Amps flush type 220 V Make: Legrand/Ancor/Havells/Kinjal/SKN
Supply and Fix switch socket combination 2 in 1, 6 pin, 5 and 15 Amps flush type 220 V Make: Legrand/Ancor/Havells/Kinjal
Supply and Fix fan regulator Electronics step type 400 watts and connecting complete all as specified and directed by Engineer-in-Charge. Make: Legrand/Ancor/Havells/Kinjal/SKN
Supply for repairing Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals. Make: Legrand/Ancor/Havells/Kinjal/SKN
Supply for repairing lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting Make: Legrand/Ancor/Havells/Kinjal/SKN
S&F Batten type LED light fitting 1x18/20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. Make: Havells/Wipro/Bajaj/C&S/Philips
S&F Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.Make: Havells/Wipro/Bajaj/C&S/Philips
Supply, fixing and testing LED bulding security light fitting of 35 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report. Make: Crompton ,Havells, philips, C&S, Bajaj, helonix, Wipro
Supply and fixing LED bulb 9 watt, 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge.
Taking down unserviceable/Serviceable ceilling fan/exhust fan of any capacity or size, refixing the same location, and unserviceable fan deposited to mes store yard all as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers
M & L submain wiring with two single core through PVC insulated unsheathed stranded copper conductor 4 sqmm (nominal area) drawing through PVC coundit concealed and 4 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note : (i) Three lenght of wire along with conduit will be measured as one Length. Make: Kalinga/Havells/Polycab/Plaza/Anchor/Finolex
Taking down unserviceable DB/MCCB/MCB of any capacity and making good disturbed surface of wall/floor complete all as specified all as directed.
S & F LoadlineDistribution board, TP&N vertical, with Bus bars, 200A, 415V Cap Netural links, blanking plates, double door 8 way, provision for MCCB 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up complete all as specified and directed., as per Make : Havells/Benlo/Legrand/Standered/Scinider/Indo asian
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 8 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up complete all as specified and directed., as per Make : Havells/Benlo/Legrand/Standered/Scinider/Indo
S & F Distribution board, SP&N, Prewired ,Netural links,blanking plates, single door 12 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up complete all as specified and directed., as per Make : Havells/Benlo/Legrand/Standered/Scinider/Indo asian
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity SPN 40 to 63 AMP in the MCB DB complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity TPN/FP 40 to 100 AMP in the DB complete with connection testing and commissioning.
Supply and fixing MCCB TP pole with thermal Release range 100 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable, complet all as specified and directed by Engr-in-Charge Make : Havells/L&T/Legrand/ Standered/Scinider/Benlo/Indo asian
Supply and fixing rotational moulded polyethlene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSr Part I of capacity 2000 Ltrs.
Supply and fixing laying GI pipe light grade 25 mm bore with all fittings as required at site and laid in floor/trenches complete all as specified by Engineer-in-Charge
S& F Gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe of size 25 mm complete all as specified by Engineer-in-Charge
Earthing complete with galvanized earth plate electrode of size 60cmx60cmx6.30mm buried directly in ground (earthpit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to & including copper earth strip of size 20X3mm dia by means of GI bolts, nuts, washers, and connected to other end to main board duly protected by 15 mm bore GI light grade pipe from earth plate. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15 cm thick all around bottom and top. Watering pipe 20 mm bore of GI medium grade pipe and including funnel, wire mesh, CI cover & frame, PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 5 of SSR Part – I. Rate are deemed to include 7.5 Mtr 20X3mm size copper strip Note : PCC/HDPE chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii). Earth resistance of earth pit should be less than 4 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (iv) Soil reistance test if required shall be the responsbility of contractor without any extra cost.
Mahadev Enterprises
M/S KHUSHI ENTERPRISES
M/S VISHRANTA CONSTRUCTION
MSK Everlast Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .