Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹77.2 L
EMD Value
₹1.5 L
Closing Date
15 Jan 2025, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
3 phase 3 wire to 3 phase 4 wire conversion and LT up gradation of old Finishing Hanger at Overhaul Division HAL BC
18349
FM/NE-P/Advt./21/24-25 Dt: 17.12.2024
Works
Electrical Planning and Contract Section-E and M Dept-FMD-Bangalore
₹0
₹1.5 L
15 Jan 2025
21 Dec 2024
21 Dec 2024
15 Jan 2025
HINDUSTAN AERONAUTICS LIMITED FACILITIES MANAGEMENT DIVISION
NAME OF THE WORK: "3 phase 3 wire to 3 phase 4 wire conversion and LT up gradation of Old Finishing Hangar at Overhaul Division, HAL(BC). " Cont.No: HAL/FMD/EC-2949/24-25
Name of the Contractor :
BILL OF QUANTITIES WITH SPECIFICATIONS
The tenderers are requested to read the following before quoting:
1 Subject tender has been called on item rate basis. Basic Rate to be quoted for each item.
2 Subject work is a Works contract and prevailing GST of 18% has been added in the BOQ on overall total. Any revision on this GST rate is to HAL account.
3 Sucessful offer that is L-1 (Lowest offer) will be determined including GST.
4 The payment terms shall be governed as per the terms indicated in General conditions of contract.
5 Amount towards GST will be paid along with RAR payment against invoice.
6 The tenderers are requested to abide by the rules of prevailing GST act.
7 This BOQ specification has to be read in conjunction with technical specifications and tender drawings. Any ambiguty in these have to be brought to the knowledge of contract section before submission of tender to avoid future claims/dispute.
Sl. No Specification of item Quantity Unit Rate in Figs excluding GST Rate excluding GST in words Amount Excluding GST in Figs (E=C*A)
Electrical Works
1 Supply, Installation, Testing & commissioning of Main LT Panel(IEC 61439 Standards) 1 Set 0.00
Design, fabrication, supply, installation, testing and commissioning of cubicle type Indoor LT Panel with front lockable door arrangement, suitable to be mounted on the floor/existing brick pedestal/cable duct using M.S channel(to be included) frame work, with cable entry from bottom/top with removable gland plates with required knock-outs, panel fabricated out of CRCA sheet steel folded and braced as necessary to provide a rigid support for all components, totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-54, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasketed using good quality EPDM gasket and/or rubber strips and ensure good lockable, durable door opening & closing mechanism, suitable meshed ventilator louvers with suitable cover,canopy type covering and Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, comprising of following switchgear and accessories complete in all respects and as directed by Engineer-in-charge.
Note:-1) Current density shall not exceed 0.8A/sq.mm for Aluminium bus bars in LT Panel
2)All MCCBs in the LT panels shall be adjustable with thermal settings(80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED module etc. complete in all respects.
3)The operating height of the Panel shall not exceed 2.1 mtr. from FFL.
i) 1No- 800A, 415V gr. 50KA 4P MCCB. Microprocessor based including MODBUS TCP/IP communication interface module.
ii) Lot - 1000A TP + 500A N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iii) 1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
iv) 1 Set-800/5A current transformers of suitable class and VA burden for metering.
v) 1no-(0-500V) range digital type Voltmeter with a push button option for selecting the phases.
vi) 1No 32 A 415V gr TP 50KA MPCB of for tapping power for metering and control circuit
vii) 1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
viii) 1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
i) 1No - 630A, 415V gr. 50KA, breaking capacity TPN MCCB Microprocessor based
ii) 2Nos - 100A, 415V gr. 36KA breaking capacity, TPN MCCB
iii) 5Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
iv) 1No - 40A, 415V gr. 10KA breaking capacity, TPN MCB
v) 1No - 32A, 415V gr. 10KA breaking capacity, TPN MCB
2 Supply, Installation, Testing & commissioning of Sub LT Panel(IEC 61439 Standards) 1 Set 0.00
i) 1No- 630A, 415V gr. 50KA 4P MCCB. Microprocessor based including MODBUS TCP/IP communication interface module.
ii) Lot - 630A , 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
iii) 1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
iv) 1 Set-630/5A current transformers of suitable class and VA burden for metering.
v) 1no-(0-500V) range digital type Voltmeter with a push button option for selecting the phases.
vi) 1No 32 A 415V gr TP 50KA MPCB of for tapping power for metering and control circuit
vii) 1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
viii) 1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
i) 1No - 125A, 415V gr. 36KA breaking capacity, TPN MCCB with panel mounted socket of model no: 81295 of Schneider make
ii) 6Nos - 80A, 415V gr. 36KA breaking capacity, TPN MCCB including star delta starter suitable for 18.5kW rated blower motor
iii) 2Nos - 100A, 415V gr. 36KA breaking capacity, TPN MCCB including star delta starter suitable for 22kW rated blower motor
iv) 1No - 63A, 415V gr. 10KA breaking capacity, TPN MCB
v) 3Nos - 32A, 415V gr. 10KA breaking capacity, TPN MCB including star delta starter suitable for 7.5HP rated water pump
vi) 1No - 32A, 415V gr. 10KA breaking capacity, TPN MCB
vii) 3Nos - 20A, 415V gr. 10KA breaking capacity, DP MCB
3 Supply, installation, testing and commissioning of 630A 4P MCCB and 400A 4P MCCB as outgoings in the existing schnieder (block set) LT TTA panel including aluminium busbar, LED indications(ON, OFF & TRIP), and necessary control & power wiring required, accessories etc., as per IEC 61439 standards.Scope of work includes making necessary cutouts in the front door for indication lamps and breaker handles etc, extending the main busbar upto breakers and breakers to cable alley for connecting outgoing cables including all other works required for fixing and commissioning of both breakers complete in all respect as required at the prevailing site requirement.(Note: While carrying the work, agency has to ensure that, no damage will be made to the existing panel and if any damage happens panel has to be brought to the original condition without any extra claims.) 1 job 0.00
4 Supply, fixing on MS truss/Perlin at approx. 10-14 mtr. height using existing angle iron frame work, required fixing hardwares etc., as per site requirement,, testing & commissioning of LED Flame proof High bay light fixture of wattage not exceeding 120 W. The technical parameters of Flame proof High bay lighting fixtures are as below: The lumiare should be Flameproof cum Waterproof, LED Well glass fitting ideal for Industrial applications with lumen output not less than 11000 lumens with symmetric beam to be achieved using suitable optics, PF >0.9 and Colour temperature shall be >5700K, IP65 rated operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures, cast Alluminium Alloy LM-6 Construction suitable for 120 W LED, 1no Stopping plug & 02 Nos PVC Shrouds as suitable and certified for gas/vapour group IIA and IIB for zone I & II and other standard accessories complete in all respects and as directed by Engineer in-charge. The Flame proof High bay Light fitting shall be of model no BIFPWG 120W CLED SD of bajaj make or Equivalent model in other approved makes luminaries which meets the above technical specification complete in all respects and as directed by Engineer-in-charge. LED used in the luminaire should be one of approved make as per approved make list of HAL. 89 Each 0.00
5 Supply, fixing, testing and commissioning of FLAMEPROOF 1x18W LED suspended type/ceiling mounted type luminaire Made of Die cast Aluminum alloy with corrosion resistant powder coated, with high efficiency acrylic wide diffuser, with wide operating voltage range,Power factor > 0.9, The lumens efficacy >90lm/watt. Operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections and other standard accessories complete in all respects and as directed by Engineer incharge. The lighting fixture shall be of Bajaj BJEXFTL 118 LED + BLRB 18W CW LED /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL. 8 Each 0.00
6 Supply and fixing on existing wall / ceiling, testing & commissioning of surface mounting, Batten type 2X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output Efficacy of minimum 100 lm/W., comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 2 Nos of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten shall be of CROMPTON-IGP161LT8-16.2XT8+LT8-20-865-(2) /Equivalent model of approved make luminaries which meets the above technical specification. complete in all respect and as directed by Engineer-in-charge. 21 Each 0.00
7 Supply and fixing on existing wall / ceiling, testing & commissioning of surface mounting, Batten type 1X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output Efficacy of minimum100 lm/W., comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 1 No of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten shall be of CROMPTON-IGP161LT8-16-1XT8+LT8-20-865/Equivalent model of approved make luminaries which meets the above technical specification. complete in all respect and as directed by Engineer-in-charge. 2 Each 0.00
8 Supply & fixing on existing MS hook 1200mm sweep,Five star rated with brushless direct current motor(BLDC) Ceiling fans complete with blades, down rods, and accessories, 230V single phase 50Hz AC supply. Minimum air delivery 210cu.m/min with service value 6.00 BEE , erected in position with necessary flexible copper leads of required colour and with canopy, down rod 300mm to 600mm length as per site requirement , necessary rubber bushings, clamps nuts,bolts etc., complete in all respects and as directed by Engineer-in-charge. 14 Each 0.00
9 Supply, installation, testing & commissioning of 300mm dia 900 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge. 2 Each 0.00
10 Supply, installation, testing & commissioning of 450mm dia 1400 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge. 12 each 0.00
11 Supply, installation, testing & commissioning of 750 mm dia Air Circulator Fan along with three speed regulator of any approved make connecting cord with 6A, 3 pin plug top and with all necessary accessories, etc., complete in all respects and as directed by Engineer-in-charge. 4 each 0.00
12 Distribution Boards
12.A Supply, fixing, testing & commissioning of the following factory built flame proof powder coated MCCB/MCB DB(flameproof protection of IIA/IIB, temperature class T6 and ingress protection of IP66) of any approved make fabricated out of die cast aluminium alloy with incoming & outgoing outgoing terminal chambers, necessary rotary switches for operating the MCCB/MCB knobs, connectors & comprising of suitable rating tinned copper busbars & earthing with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips, neoprene gasket etc., & fixing the DB on wall with necessary M.S. angle supports etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
a) 4 Way Vertical Type 4P Flame Proof MCB DB 1 Each 0.00
b) 6 Way Horizontal Type 4P Flame Proof MCB DB 2 Each 0.00
12.B Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
a) 6 way (4 + 18), Horizontal Double door MCB DB 1 Each 0.00
b) 4 way (4 + 12), Horizontal Double door MCB DB 1 Each 0.00
Supply, fixing, testing & commisisoning of following rating MCBs in the existing Distribution board/powder coated enclosure/flame proof DB as directed by Engineer-in-Charge.
a) 40-63 amps. ratings , 4P MCB, "C" curve, 10 KA breaking capacity. 5 each 0.00
b) 6-32 amps. ratings , SP MCB, "C" curve, 10 KA breaking capacity. 60 Each 0.00
c) 6-32 amps. ratings , TP MCB, "C" curve, 10 KA breaking capacity. 1 Each 0.00
14 Supply, laying, testing & commissioning of following size LT armoured power cables.
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Aluminium (Al) /Copper (cu) conductor 1.1 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment earthed Armoured (Arm) U.G cables and as per technical specification including stacking at site, proper storage complete etc. as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
a) 3.5 CX 300 Sqmm Aluminium armoured conductor. 350 Meter 0.00
b) 3.5CX 185 Sqmm Aluminium armoured conductor 100 Meter 0.00
c) 3.5 CX 25 Sqmm Aluminium armoured conductor. 250 Meter 0.00
d) 4 CX 16 Sqmm Aluminium armoured conductor. 70 Meter 0.00
e) 4C X 6 Sqmm Copper armoured conductor 50 Meter 0.00
f) 3C X 10 Sqmm Copper armoured conductor 800 Meter 0.00
g) 3C X 6 Sqmm Copper armoured conductor 220 Meter 0.00
h) 3CX 4 Sqmm Copper Armoured conductor. 350 Meter 0.00
i) 3C X 2.5 Sqmm Copper armoured conductor 850 Meter 0.00
15 Supply and connecting indoor type cable end joints for the following size 1.1 KV gr., PVC insulated and PVC sheathed / XLPE Aluminium(Al)/ Copper(Cu) conductor armoured (Arm) LT UG cables by employing necessary glands, terminals(Al/Cu), bolts & nuts etc., complete in all respects and as detailed below:
a) 3.5C X 300 sq. mm Al arm cable 4 Each 0.00
b) 3.5C X 185 sq. mm Al arm cable 4 Each 0.00
c) 3.5C X 25 sq. mm Al arm cable 8 Each 0.00
d) 4C X 16 sq. mm Al arm cable 2 Each 0.00
e) 4C X 6 Sqmm Copper Armoured LT Cable End Joint 4 Each 0.00
f) 3Cx10-16Sqmm armoured Copper cable end termination 32 Each 0.00
g) 3Cx6Sqmm armoured Copper cable end termination 12 Each 0.00
h) 3C X 4 Sqmm Copper Armoured LT Cable End Joint 82 Each 0.00
i) 3C X 2.5 Sqmm Copper Armoured LT Cable End Joint 108 Each 0.00
16 Wiring for light point / fan point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC/GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
a) Wiring to single light/fan point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects. 20 Pts 0.00
b) Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects. 13 Pts 0.00
c) Wiring to exhaust fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box(MS/PVC) if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects. 2 Pts 0.00
d) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 14 Pts 0.00
e) Supplying and fixing suitable size PVC/GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.(For 5/15A powerpoints, Air circulators & Exhaust fans) Note: 3/5 pin 16A, 250V gr. modular type socket to be housed near the exhaust fan/Aircirculator complete and Switch at reachable height in all respects. 60 Each 0.00
17 Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 3 x 2.5 sq. mm (For lighting ckt from DB to Switch box) 200 Mtr 0.00
b) 3 x 4 sq. mm(For 16A power points, Air circulators & Exhaust fans in hangar) 700 Mtr 0.00
18 Supplying and fixing of Hot dip galvanised Perforated type cable tray of following sizes, steel: As per IS:2062 / 1079, Galvanising : As per IS: 2629 / 4759 including all accessories like base slotted angle, horizontal elbow, horizontal tee, horizontal cross, horizontal reducer, vertical elbow up, inside, vertical elbow down, outside, coupler plate, fasteners etc., and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures upto a height of 10-12 mtrs from FFL., complete in all respects and as directed by Engineer in charge
a) Supplying and fixing of 150 x 50 x 1.6mm size Hot dip galvanised Perforated type cable tray 250 Meter 0.00
b) Supplying and fixing of 300 x 50 x 1.6mm size Hot dip galvanised Perforated type cable tray 50 Meter 0.00
19 Supply and fixing of weather proof cable junction box with terminals of size 104 mm x 104 mm x 70 mm Hensel Cat. No. DK 0404G or equivalent in Legrand/ Schneider/ Hagar make only. The Box shall be mounted at suitable height on the MS truss/wall/pole/L-angle using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge. 89 Each 0.00
a) Supply & providing GI earth stations using 600 x 600x 6.3 mm thick G.I plate electrode at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2 runs of 50x6 mm G.I strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender & as per IS 3043 complete in all respects. 4 set 0.00
b) Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and the LT panels earthing as directed by Engineer-in-charge. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm) Note:- Excavation, concrete cutting & re concreting will be measured separately. 70 Mtr 0.00
c) Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm) 250 Meter 0.00
d) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 50 Meter 0.00
21 Supply & spreading 75mm thick sand cushioning on top & bottom of the two runs of cable and covering the cable by well burnt bricks on sides and top of the cables as per technical specifications enclosed and as directed by the Engineer-in-charge. 30 mtr 0.00
22 Carrying out Mechanized Horizontal directional drilling of soil under the existing road/gate way for laying 1run of HDPE pipe including supply and laying 2 run of 125 mm dia PE100 PN08 HDPE pipes with ISI mark and conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 2Rx125mm"complete as directed by Engineer in charge. 130 mtr 0.00
23 Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge. 10 CUM 0.00
24 Concrete cutting/Chipping the existing 1:2:4 cement concrete road /pavements/Bitumen Road / flooring including removing debris from the work site as directed by the Engineer-in-charge. 10 CUM 0.00
25 Re-concreting the cut portion with 1:2:4 cement concrete by employing 20mm graded aggregate granite, smooth finish including curing, complete in all respects and as directed. 8 CUM 0.00
26 Design, Fabrication, Supply and fixing/grouting in wall/ceiling of suitable size MS angle iron supports/ flat/ brackets for cable tray supports, high bay light fixture supports, high bay cabling and etc., as per site requirement and painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer complete in all respects and as directed by EIC/OIC. 500 Kg 0.00
27 Supplying and laying of 160 mm dia (OD-160 mm & ID-135 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 50 mtr 0.00
28 Disconnecting/dismantling & removal of the following items as-is-basis without any damage and handing over the same to the place as shown by Engineer-in-charge/Plant Maintenance department of Overhaul Division ( not more than 2KM ) including loading, transportation, unloading etc., complete in all respects and as directed by the engineer-in-charge. 1 Lot 0.00
Industrial type LT Panels-5nos
Lighting saver Panels-2nos
DB’s/Meter Boards- 8nos approx
LT Cables(beyond 16Sqmm to 150Sqmm): 150Mtr approx
Lighting/power Cable(2.5sqmm upto 16sqmm) on wall and truss: 3200Mtrs approx
MCB DB/MCB with socket/Industrial plug & socket: 25sets approx
5A/15A plug & Socket/Switch socket/wooden switch board/flame proof switches: 100sets approx
High Bay/Flameproof Lights on truss@10mtr height approx: 70nos approx
Igniters on wall@8mtr height approx: 70nos approx
Exhaust Fans/air circulators/ceiling fans: 25nos approx
PVC/MS Conduit with wire/cable: 800mtrs approx
Tube lights: 35nos approx
Not withstanding to above, any other electrical items required to complete the work in all respects like Switches/switchgear/cables/ conduits/wires/ lights/switch boards and etc., shall be removed and handed over to Plant maintenance dept as per the direction of Engineer-in-charge.
Note: Agency may visit the site before quoting to access the above item. No additional claims will be entertained for removal of items at the later stage.
a) Supply, Fixing, in flush with wall as per site condition, suitable size modular GI box/PVC box as per site requirement with base plate, glossy front cover for supply and housing of 1 No. of Twin RJ-11 telephone socket outlets with shutter including necessary interconnections, chipping the wall and replastering to smooth finish to match the existing wall wherever necessary as per site condition. Complete in all respects and as directed by Engineer-in-charge. 5 Each 0.00
b) Supply & drawing of 0.5 mm dia copper conductor PVC insulated 5 pair colour coded and unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations. 200 Mtr 0.00
30 Supplying and fixing of 20mm dia ISI marked PVC conduit pipe of medium class along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 120 Mtr 0.00
Total Amount Excluding GST 0.00
Add 18% GST 0.00
Total Amount Including GST 0.00
Total Amount inclusive of GST In Words
HINDUSTAN AERONAUTICS LIMITED
Facilities Management Division
Pre-Qualification Profile (To Be uploaded along with Part A)
Tender Ref No. or Contract No.: HAL/FMD/EC-2949/24-25
Name of Work: 3 phase 3 wire to 3 phase 4 wire conversion and LT up gradation of Old Finishing Hangar at Overhaul Division, HAL(BC).
Estimated Amount in Rs.: 7717000
Tender Notice Date: [DD/MM/YYYY] Tuesday, December 17, 2024
GST ID NO. for HAL 29AAACH3641R1Z3
Sl.No Description Details Enclosed / Not Enclosed Remarks
1 Name of the Individual / Firm / Company: * Mandatory Please Enter Name of the Individual /firm /company
2 Type of ownership PleaseEnter Type of Ownership
If Other, please specify
3 Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc., Please enter Details of Constitution
4 Address for correspondence: Please Enter Address
5 Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No. Related Document to be Uploaded to eProcurement Portal (Note Cancelled cheque leaf to be uploaded)
Name of the Bank
Type of Account
6 PAN No.: Please Enter Pan NO
7 Average annual financial turn over during the last 3 years, ending 31st March of the previous financial year [ should not be less than 30% of Amount put to tender] 4999999 3
YEAR TURN OVER IN Rs: Enclosed / Not Enclosed REMARKS 5000000 2
2023 – 2024 Rs: Please Enter Turn over in Rupees for all the 3 years 7499999 2
Average annual Financial turn over 0.00 2315100.00
Avg Annual Turnover criteria is not met 10000000 1
8 PF No.: Please Enter PF NO
9 ESI No.: Please Enter ESI NO
Location of Agency/organisation: Please Enter GST Details
Any Special Status of the Unit i.e. DTA, EOU, SEZ, FTWZ
Registered under regular scheme or Composition Scheme or Not Registered Related Document to be uploaded in ePortal
11 Contact details
Contact person name Please Enter Contact person Name
Mobile No. Please Enter Mobile No
Ph. No. with STD code
FAX No. with STD code #N/A #REF!
12 Valid Electrical contractor license of appropriate voltage (Minimum 650V) issued by any state Govt. under clause 45 of Indian Electricity Rules 1956 or as amended from time to time Please SELECT YES OR NO
13 I.T Returns for past 03 years 999999 5 J 6
Assessment year 2024-25 Please Select 'Yes' ' No' for IT Return for All Three years 1000000 4 K 7
Assessment year 2023-24 2499999 4
Assessment year 2022-23 2500000 3
14 Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued within a period 12 months from the final date of submission of tender. solvency cal
Name of Bank & Branch: Please Enter Details to 'Name of the Bank' , 'Date of Issue','Value in C89``Rs. in Lakhs 12-17-24 28-Jun 0 40000
Date of Issue[DD/MM/YYYY]: 200000 40000
Value of Rs. In Rupees: 200001 150000
Solvency value is NOT as per NIT
15 Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender should be either of the following: [Work completion certificates along with LOA/PO/WO should be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated amount put to tender. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated amount put to tender. (iii) ONE similar completed work costing not less than the amount equal to 80% of the estimated amount put to tender. 3086800 500001 250000
Completed similar works during last 7 years Please Select %of similar works completed during last 7 years 1000000 250000
Work No I Type of Work: [Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 1000001 500000
Brief Description of Work: 2000000 500000
Completed value of Work in Rs. Lakhs: 2000001 1000000
Date of Commencement of Work [DD/MM/YYYY] 4000000 1000000
Date of Actual Completion of Work[DD/MM/YYYY]: 4000001 2000000
Work No II Type of Work: [Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 10000000 2000000
Brief Description of Work: Please Enter Details for Work No II
Completed value of Work in Rs. Lakhs:
Date of Commencement of Work[DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]: work done
Work No III Type of Work: [Incase of private works the same shall be supported with TDS certificate] Related Document to be Uploaded to eProcurement Portal 12-17-24 2555
Brief Description of Work: Please Enter Details for Work No III 12-19-17
Completed value of Work in Rs. Lakhs:
Date of Commencement of Work[DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]:
16 Details of person holding the power of Attorney :
Name Related Document to be Uploaded to eProcurement Portal
Mobile No. Please Enter Details for Person holding Power of Attorney
Ph. No. with STD code
FAX No. with STD code
17 DECLARATION I
The document being viewed / downloaded from the website and having read & understood all the contents of the tender document mentioned under Pre-qualification criteria, technical bid ( Page 1 to 164) and price bid do hereby accept all the terms and conditions laid down in the said Tender document and will abide by the same on acceptance and award of work. Please Accept the Declaration I
18 DECLARATION II
I/We declare and confirm that - 1. All information and attachments submitted along with this offer are true and correct. 2. I/We are aware that any false information provided herein will result in the rejection of my offer . 3. I/We shall not make refund claims of expenditure incurred in processing this offer. 4. I//We are aware that document sought only be uploaded for evaluation of offer. 5.I/We shall not associate nor has been associated in the past, directly or indirectly with consultant or any other entity that would prepare the design, specification and other documents of the project. Please Accept the Declaration II
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
Tender_Drawing_No_1.pdf
TENDER_DOCUMENT • 0.06 MB
Tender_Drawing_No_3.pdf
TENDER_DOCUMENT • 0.16 MB
Tender_Drawing_No_4.pdf
TENDER_DOCUMENT • 0.07 MB
tender_Notice.pdf
TENDER_DOCUMENT • 0.46 MB
Tender_Drawing_No_2.pdf
TENDER_DOCUMENT • 0.08 MB
Price_Bid_2949.pdf
TENDER_DOCUMENT • 0.36 MB
technical_Bid.pdf
TENDER_DOCUMENT • 4.62 MB
PQ_Freeview.pdf
TENDER_DOCUMENT • 0.21 MB
AmendmentNoIEC2949.pdf
TENDER_DOCUMENT • 0.23 MB
CLARIFICATION_NO_1_2949.pdf
TENDER_DOCUMENT • 0.23 MB
Price_Bid.xlsm
TENDER_DOCUMENT • 0.05 MB
Pre_Qualification.xlsm
TENDER_DOCUMENT • 0.03 MB
ECS_Formet.pdf
TENDER_DOCUMENT • 0.19 MB
Check_List.pdf
TENDER_DOCUMENT • 0.11 MB
Undertaking_Letter.pdf
TENDER_DOCUMENT • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .