Driller-in-Charge. BMSD(D)
Office of the Driller-in-Charge. Bankura Mechanical Sub-Division (Drilling). P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102
Repairing works for LT panel, Incomer panel, with supply of valve and others allied works at WTP of MKT New under Khatra, Hirbandh, Ranibandh surface Water Based Piped Water Supply Scheme under Khatra Block, Dist-Bankura under BMD,PHE Dte.
2026_PHED_5073822_7
WBPHED/BMSD(D)/NIeT- 01 OF 2026-2027
Open Tender
Electrical Work/ Equipment
Item Rate
20 days
Ailakundi
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,000
Yes
24 Sept 2026
24 Sept 2026
7 Oct 2026
24 Sept 2026
5 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fault finding and checking of all the switch gear items by dismantling required switch gear items along with all of the electrical power circuit (from busbar to all the contractors) and control circuit (for required switch gear items) routing making necessary cleaning of the all the different soft starter feeder for Centrifugal Pump (4 nos 300 HP , 4 Nos 350 HP ) , LT MCC Panel with for operation, by dismantling the existing fixd board (on which the switch gears were fixed) and checking faults of the above said items by prident electrician by proper elecrtical & electronics instruments as needed to complete the work by panel manufracturer as per direction of EIC. | 1 | LS | -148 | - |
| 2Supply delivery of the following items for 300 HP & 350 HP Feeder | |||||
| 2.1 | Supply delivery at site of Air Break Power AC3 duty 140 Amp at 415 volt, AC 50 Hz coil for suitable voltage with 2 NO + 2 NC (Model - 3TF5102 or equivalent ) (Make- Simens or equivalent ) | 1 | Each | -146 | - |
| 2.2 | Supply delivery at site of Magnetic only and Microprocessor based short circuit protection MCCBs 50 kA, Ics(Icu)-100 % , 3 pole 630 amp with Ekip Dip, Ekip Touch/Hi-Touch, MA - Magnetic only trip unit with adjustable magnetic thresholds for motor protection TMF - Fixed thermal and fixed magnetic for power distribution, TMD - Adjustable thermal (70-100%of In) and fixed magnetic (10 x In) for power distribution TMA - Adjustable thermal (70-100% of In) and adjustable magnetic (5-10 of In) for power distribution, TMG - Adjustable thermal (70-100% of In) and low fixed magnetic (3 x In) for generator protection With selector in ON position, circuit breaker trips if at least one current phase is lower than 0.1xIn and at least a second one higher than 0.25xIn or equivalant specification (Make-ABB/Equivalent) | 1 | Each | -145 | - |
| 2.3 | Related Hardware for rectification (cable tie, socket, fork, R/YB Tapes, metal sheets, nuts, bolts, board for fixing items etc ) of differet centrifugal feedrs of with complete new wiring to both the control and power circuit to complete the job as per direction of EIC | 1 | LS | -144 | - |
| 3 | Installation of the above switch gear items and making complete connection of all the control and power circuit of all thesubmersible and chlorine feeders by cutting and welding for fixing the different switch gear items by proper prudent electrician and workman and testing commissoining up to a certain period of operation upto the satisfaction of EIC, as per direction of EIC . | 1 | LS | -143 | - |
| 4 | Supply and delivery at site of Single row deep groove ball bearing 6314-2Z/C3 or equivalent with steel seal on both sides (for non drive end of the pump set ) for Wilo Mather and platt make (Make-SKF) | 8 | each | -142 | - |
| 5 | Supply and delivery fitting fixing at site of at site of eccentric design gear operated, double flanged Ductile Iron butterfly valves generally conforming to IS-13095, having body, disc and end cover in graded Ductile Iron to ls:1865 Gr 500/7, Nitrile rubber face ring secured on disc by a SS AIsl 304 retaining ring with stainless steel screws, the rubber ring seating on a corresponding SS AIsl 304 seat in body, stub shaft of SS AIsl 410 riding in teflon bearings. Flanges drilled to ls 1538 Table 4 & 6. Valves suitable for a working pressure of 16kg/cm2 (seat test) & bedy tested to 24 kg/cm2 valves are suitable for operated with Rotork Syncropak /AUMA Epack electrical actuator having inbuilt reversal starter with position indicator . 300 mm dia , PN-2.5 rating (Only supply of valve is needed) (Make : IVI / IVC / Kirloskar/Jupiter)
(All routine test including high pressure test to be performed in presence of EIC and teat certificate to be produceed before delivery. ) | 1 | Each | -141 | - |
| 9 | Add: 18% GST | 1 | Item | 9 | ₹9 |
| 10 | Add: 1% Cess | 1 | Item | 10 | ₹10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 28.02 MB
Tendernotice_2.pdf
PDF • 1.11 MB
BOQ_5162112.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .