| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 5 A KALPANA NAGAR 7TH CROSSING MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.3 L+₹2.8 L (24.8%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical 123 B CENTRAL AVENUE SAINIK FARMS NEW DELHI 110062 | NEW DELHI | NEW DELHI | DELHI | 110062 | - | Rejected-Technical Declared unenlisted by HQ CECC |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
REPAIR AND MAINTENANCE OF 33/11 KV MRS AND CONNECTED WORKS AT MORAR CANTT UNDER GE GWALIOR
2021_MES_496954_1
CWE/JHA/GWL/TOKEN/90 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE GWALIOR
₹40,000
Yes
19 Mar 2022
23 Dec 2021
24 Jan 2022
23 Dec 2021
19 Jan 2022
7 Jan 2022
60 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed.
Returning, filling in ,including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning with layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches after the cable has been tested complete all as specified and directed.
M&L for laying precast concrete cable cover, class HV, Type 1 of size 300mmx180mmx40mm complete all as specified and directed.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 100mm dia for cable protection complete all as specified and directed.
Supply and fixing disc type insulator porcelain, vitreous, brown with ball socket and tensioning clamps 2U type for 33 KV complete all as specified and directed.
S&F in repair Bymatelic connector suitable for 33/11 KV CT/PT all as specified and directed.
Supplying, laying, jointing & testing 95 sqmm 3 core XLPE insulated & PVC sheathed armoured earthed HT cable, 11000 volts grade heavy duty with aluminium conductor laid in trenches/pipe/fixed on the wall etc complete all as specified and directed.
S & F in repair heat shrink end termination outdoor type Cable jointing kit for 11KV HT XLPE cable of size 95 to 120 Sqmm 3 core complete with jointing material and accessories complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size, for HT of size 25x20cm size complete complete all as specified and as directed.
Disconnecting 33 KV incoming and outgoing connections of VCB of any description and any make of rating 33 KV, 1250Amps dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing and commissioning complete all as specified and directed. (Note: - The new spare parts any type will be measured and paid separately.)
Disconnecting 33 KV incoming and outgoing connections of SF6 BREAKER of any description and any make of rating 33 KV,1250Amps complete all as specified and directed by Engineer-in-Charge. dismantling / opening of the SF6 for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the SF6 after overhauling / servicing and its testing and commissioning complete all as specified and directed. (Note: - The new spare parts any type will be measured and paid separately.)
Taking down the existing relays (two Nos over current and one no earth fault relays) fixed in 33/11KV HT Panels for primary and secondary injection and calibration of all the relays and setting the relay tripping timings in advance to the feeding sub-station to ensure pockets wise installation of various relays in position with complete control and test and trial complete all as specified and directed. Note :- (i) The primary injection kit shall be arranged by the contractor. (ii) The DC supply for relay testing shall be arranged by the contractors.
Disconnecting & taking out indoor VCB of any description and any make of rating 11 KV, 400 Amps/630/800/ 1200 Amps dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable /detective parts including cleaning and servicing greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing and commissioning complete all as specified and directed. (Note: - The new spare parts any type will be measured and paid separately.)
Disconnecting & taking out VCB outdoor of any description and any make of rating 11 KV, 400 amps/800 Amps, dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable/detective parts including cleaning and servicing greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing and commissioning complete all as specified and directed. (Note: - The new spare parts any type will be measured and paid separately.)
Testing of leakage of gas of SF6 breaker 33 KV rectifying leakage testing with filling Nitrogen gas making the breaker leak proof filling gas in breaker and testing complete all as specified and directed.
M&L for Cleaning/scraping/decarbonising of VCB indoor panel from inside, bus bar chamber, cable entry box removal of dust carbon particals and painting with super enemaled synthetic paint without efecting wiring busbar and other items complete all as specified and directed.
Supply and fixing in replacement over current earth fault relay 30V DC for 33/11 KV pannal . MAKE CG/EASUN/ABB complete all as specified and directed.
M&L for fxing testing and commissioning of the following items on completion for 11 KV VCB 400/800 Amps capacity of conforming to the respective cat part given as under complete all as specified and directed. Make:- Crompton Greaves cat part No mentioned against each item or equivalent model as approved by GE. (Note (i) fixing and testing element of following item is deemed to be included under sch 'A' item No - above (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Vacuum interrupter type 190241725/SP VI (3" Dia) Type 34599 M3+ for 11 KV VCB complete all as specified and directed.
Epoxy bushing for 11 with metal parts complete all as specified and directed.
Isolating contact assembly 400/630 Amp. Cat part No 503 complete all as specified and directed. Make - CG
Spout bushing. Cat part No 580 complete all as specified and directed. Make - CG
Phase barrier with spacer. Cat part No 528 complete all as specified and directed. Make - CG
Motor and gear assembly for 230 volt AC/DC for 11 KV VCB, Cat part No 537 complete all as specified and directed. Make - CG
Spring charging handle for hand operating 558SP complete all as specified and directed. Make- CG/ALSTHOM
Support insulator. Cat Part No 591 complete all as specified and directed. Make - CG
Big gear assembly. Cat part No 543 complete all as specified and directed. Make - CG
Small gear assembly. Cat part No 573 complete all as specified and directed. Make - CG
Auxiliary switch (7 No + 7 NC). Cat part No 563 complete all as specified and directed. Make - CG
Closing coil assembly 30 volts DC. Cat part No 594 complete all as specified and directed. Make - CG
Tripping coil assembly 30 volts DC. Cat part No 599 complete all as specified and directed. Make - CG
Trip catches assembly. Cat part No 626 complete all as specified and directed. Make - CG
Spout insulator assembly (Back) complete 11 KV 400 AMP complete all as specified and directed.
Plug andd socket assembly 560 SP complete all as specified and directed. Make - CG
Trip shaft assembly. Cat part No 574 SP complete all as specified and directed.
Close shaft assembly Cat part No 575 SP complete all as specified and directed.
Big and small gear assembly for out door VCB 11 KV 543 SP1 CG complete all as specified and directed.
Upper and lower insulator assembly for 11 KV 350 MVA out door breaker with flanges assembly..11P002 complete all as specified and directed.
M&L for fxing testing and commissioning of the following items on completion for 33 KV VCB/SF6 breaker 1200 Amps capacity of conforming to the respective cat part given as under complete all as specified and directed. Make:- Crompton Greaves cat part No mentioned against each item or equivalent model as approved by GE. Note (i) fixing and testing element of following item is deemed to be included under sch 'A' item No - above (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Closing coil assembly 30 volts DC for 33 KV VCB/SF6 Breaker.33P019 complete all as specified and directed.
Tripping coil assembly 30 volts DC for 33 KV VCB/SF6 Breaker. 33P018 complete all as specified and directed.
Remote control switch(TNC) for 11/33 kv SF6/VCB panel 618SP complete all as specified and directed.
Motor and gear assembly for 230 volt AC/DC (as per sample) for 33 KV VCB/SF 6. 33P007 complete all as specified and directed. Make - CG
Driver rod with slide shaft 33P003 CG complete all as specified and directed.
Trip shaft with spring 33P014 complete all as specified and directed.
Closing shaft with spring 33P015 complete all as specified and directed.
Trip cath with linkage 33P023 complete all as specified and directed.
Big cam with main shaft 33P022 complete all as specified and directed.
Auxiliary switch (7 No + 7 NC). Cat part No 33P024 complete all as specified and directed. Make - CG
Vacuum interrupter type VL 35416-13 for 33 KV VCB complete all as specified and directed.
Ratchet Wheel for 33 KV SF6 BREAKER complete all as specified and directed.
Powel set for 33 KV SF6 BREAKER complete all as specified and directed.
Set of `O' ring for pole for 33 KV SF6 BREAKER complete all as specified and directed.
NATV Roller 15 for 33 KV SF6 BREAKER complete all as specified and directed.
NATV Roller 20 for 33 KV SF6 BREAKER complete all as specified and directed.
Indicator LED lamps of different colour 30 V DC complete all as specified and directed.
Indicator LED lamps of different colour 230 V DC complete all as specified and directed.
Digital multi funcitinal meter for VCB indoor panel Rish master 3440 complete all as specified and directed. Make : Rishab/Conserve/Alpha
Digital Amp meter for VCB indoor panel 96 sq mm complete all as specified and directed. Make : Rishab/Conserve/Alpha
Digital Volt meter for VCB indoor panel 96 sq mm complete all as specified and directed. Make : Rishab/Conserve/Alpha
Supply and fixing in replacement master trip relay 30V DC complete all as specified and directed. Make : CG/EASUN/ABB
Supply and fixing PT (Voltage Transformer) for 11 KV indoor VCB, draw out type, 11 KV, 11000/110 V, VA-5 CLASS 1 RATED FRIQUENCY 50 HZ complete all as specified and directed. Make - CG/alsthom/laxmi
Supply and fixing CT (Current Transformer) for 11 KV indoor VCB, epoxy dry type, 11 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 100-50/5+5 complete all as specified and directed. Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing CT (Current Transformer) for 11 KV indoor VCB, epoxy dry type, 11 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 200-100/5+5 complete all as specified and directed. Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing CT (Current Transformer) for 11 KV Out door, oil immersed type, 11 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 200-100/5+5 complete all as specified and directed. Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing PT (Voltage Transformer) for 11 KV out door VCB,oil immersed, 11 KV, 11000/110 V, VA-5 CLASS 1 RATED FRIQUENCY 50 HZ complete all as specified and directed. Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing CT (Current Transformer) for 33 KV Out door, oil immersed type, 33 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 200-100/5+5 complete all as specified and directed. Make - CG/kappa/Alsthom/Laxmi/Pragti
Reparing servicing overhauling of 33 kv CT/PT replacement of wisher packing set, bushing with brass metal parts, making leak proof and replacement of insulating oil and painting complete all as specified and directed.
Reparing servicing overhauling of 11 kv CT/PT replacement of wisher packing set, bushing with brass metal parts, making leak proof and replacement of insulating oil and painting complete all as specified and directed.
Reparing/servicing/overhauling to 11 KV air break switch, cleaning greasing and making smooth functining from ground level (spares required will be paid seperately) complete all as specified and directed.
S&F in repair Bymatelic connector suitable for 33/11 KV CT/PT complete all as specified and directed.
AMEC GLOBAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .