Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹91.7 L+₹2.8 L (3.20%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L2 | Rejected-Finance Being higher bidder | |
| 3 | Rejected-Technical 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | - | Rejected-Technical Due to two class below from eligible class |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
14 Oct 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Agra
HQ CWE(AF) Agra PIN-282008
PROVN OF MANUALLY OPERATED HANGER DOOR FOR S AND TTU HANGER AND ASSOCIATE WORK AT AF STN AGRA
2021_MES_474288_1
80021-14/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) Tech Area Agra
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE(AF) Tech Area Agra
₹1.9 L
Yes
25 Nov 2021
10 Sept 2021
18 Oct 2021
10 Sept 2021
14 Oct 2021
30 Sept 2021
60 days
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards any thickness and in any position including cover fillets complete all as specified and as directed.
S&F HPSC pre-prime non asbestos fiber cement building board 4mm thick , decorative finish fixed to aluminium or GI Powder coated snap grid frame work with screw in ceiling complete all as specified and directed.
S&F GI powder coated snap grid frame work of size (605mm x 605mm) with main runner (32x24x6.5) mm, cross tee (27x24x2.5)mm and moulding (19 x19)mm for false ceiling complete all as specified and directed”
S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to roof slabs mean of ceilling cleats made out of GI flat 40X3mm size 60 mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Taking down door chowkhats or frames with shutters of any description exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frame) complete all as specified & directed.
Taking down window chowkhats with shutters of any description not exc 1.5 sqm each (without taking off shutters from the frame) all as specified & directed.
S&F Aluminium door single leaf with anodized/powder coated aluminium frame of section 62.5x37x1.5mm thick, shutter with bottom & middle rail of section 112.50x 37x1.5mm thick and styles & top rail of section 83x37x1.5mm thick with centrally locking arrangement with lock, make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5mm thick glass including necessary fittings, fixtures & aluminium snap beads complete all as specified and directed.
S&F anodised aluminium powder coated window and ventilator shutters with frame side hung type without sash bars ,aluminium sections weighing 0.55 kg/m including necessary joining cleats,5 mm thick glass,glazing clips,rubber packing,anodised aluminium snap beading,screws,anodised aluminium fittings such as peg stays 150 mm long(1 No.).hinges type B-21 100 mm long (2 No.) suitable handle (1 No.) in each shutter complete all as specified and as directed.
Hacking out old broken glass (any thickness,size or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified & directed.
S & F for 3mm thick sheet glass ordinary quality and glazing with oil putty in square n-exc 0.5 sqm in each pane complete all as specified & directed.
S&F 5.5mm thick sheet glass in aluminium doors & windows with rubber packing ( any thickness, size from aluminium beading ) complete all as specified and as directed.
S&F aluminium partition wall of section as in frame size 63.5X38.1X1.0 mm thick with 12 mm thick prelaminated particle board (size of panel n.exc 1.5 sqm) and all necessary fittings with and including taking down old partition wall frame including all accessories complete all as specified and as directed.
S&F in repair door closer hydraulically , aluminium (die cast type) body, regulated designation No. 1, universal type, suitable for door shutter upto 700mm in width and weight not more than 35 Kg and fixed complete all as specified and directed.
Dismantling brick tiles or terracing tiles, single layer on roofs including bedding and membranes of any type and wire brushing and cleaning top surface of tiles,lime terracing or cement concrete,including flashings and junction of parapets etc and surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.7 kg per sqm, blinded with grit or pea size gravel @ 0.006 cu. m per sqm and lightly tampered (area of flashings etc shall be added to the roof area) complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 complete mixed with 2 % water proofing compound as per manufacturers instructions (note:Water proofing compound shall be measured and paid seprerately under respective item) over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gram/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gram/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm.
M&L for 20cm X 20cm X 20mm thick PCC tiles, machine pressed factory made as per IS-1237-1980 (ISI marked) laid over 20mm thick screed bedding in CM (1:4) mixed with water proofing compound (liquid type) @ 200ml per 50Kg of cement and tiles joints shall be filled with polymer based cement proof joint filler manufactured by approved company complete all as specified and directed.
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement being cut complete all as specified and directed.
Taking down existing rolling shutter complete any type width and height not exceeding 3 mtr in any position complete all as specified & as directed.
M & L for 1.25mm thick steel rolling shutter upto height 3m, without ball bearing as specified including guide channel, top covers anchoring rod, hasp and staple and other necessary, accessories required to function the shutter and applying two coats of synthetic enamel paints over one coat of primer erected-in passion as indicted complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level).complete all as specified & as directed.
M & L for 25 mm thick plain cement concrete (1:2:4), type B0 (using 12.5 mm graded stone aggregate) in base course of flooring without using extra cement complete all as specified & as directed.
M&L light shade colour vetrified ceramic tiles 10mm thick (square/rectangular ) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bed layers as in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match existing completed all as specified and directed.
M&L light shade colour vetrified ceramic tiles 10mm thick (square/rectangular ) polished, area of each tiles n.exc 0.36 sqm in skirting etc laid over and including 10 mm thick backing coat in CM (1:3) set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Dismantling floor,hearth or wall tiling including cement mortar bedding/backing,removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for Non skid, joint free (edgecut) coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) polished area of each tile exceeding 0.11 sqm but not exeeding 0.18 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
M&L for glazed, coloured, ceramic tiles of size not less than 350x450x7mm thick as in skirting/dado/ on other vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM (1:3) all as specified and directed.
Dismantling of Galvalume sheet in roof covering including ridge all as specified & directed.
S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self taping screws complete all as specified & directed.
S&F Prepainted galvalume aluminium zinc coating GI based steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in ridge of roof covering/cladding to wall,fixed with self taping screws complete all as specified & directed.
Taking down steel water tubing and connection 20mm dia bore incl cleaning for refixing or removal to store complete all as specified & directed.
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20mm all as specified and directed.
S&F in repair stop valve/Angle cock 15mm dia bore fancy type, CP with long shank and cup (concealed) complete all as specified and directed.
S& F in repair for Chromium plated fancy type 15 mm bore dia Bib tap complete all as specified and directed.
S & F in repair vitreous china wash down water closet ( pedestal pattern), white, including PVC seat cover white with hinging device, jet spray etc complete all as specified and directed.
S&F in repair for PVC valveless syphonic action flushing cistern, low level, (10 ltr capacity) white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F in repair vitreous china urinals, half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; with grating and union for discharge pipe, all as specified and as directed.
S&F in repair wash hand basin vitreous china wash basin white flat back size 550x400 including supplied and fixed angle iron brakets errecting stand, CP waste coupling, waste pipe complete all as specified and directed.
S&F in repair toTubular towel rail, 20mm dia, D type, 60cm long between flanges compete all as specified and as directed.
S&F in repair CI floor trap 100mm dia bore with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F in repair for PVC connection 15mm size with brass nuts of length 450mm complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1: 6) all as specified and as directed.
Taking down cement or cement lime plaster on brick or stone and concrete wall /Ceilling etc including raking out joints haking for key scrubbing down with water etc in any description all as directed.
M&L for rendering 15 mm thick on brick or concrete surface of walls in cement mortar (1:6) finished even & smooth without extra cement on internal wall surface complete all as specified and as directed.
M&L for rendering 15 mm thick on brick or concrete surface of walls in cement mortar (1:4) finished even & smooth without extra cement including mixing only water proofing compound as per manufacturer instruction on external wall complete. Note:- WPC will be measured & Paid separately
Supply only of integral water proofing compound confirming to IS-2465-1075 all complete and all as specified .
M&L for rendering 5 mm thick in cement mortar (1:3) on brick or concrete surfaces on ceiling finished even & smooth without extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces by complete removal of existing treatment of plastered or un-plastered surfaces of walls and applying two coat of distemper oil emulsion white or tinted over a coat of primer including peparation of surface complete all as specified and directed.
M&L for complete removal of existing treatment of old surface including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and cleaning with water on wall complete all as specified and directed.
M&L for applying 2 coat of weather proof exterior emulsion paint in camouflage pattern by diluting of water (as per manufacturer direction) a gap of 24 hours should be given between two coats, over a coat of primer on plastered/unplastered surface should be allowed to cure completely such as surfaces applying one coat of exterior wall primer by thinning a litre of primer with one Ltr of water allow the primer coat for four hours incl cleaning and ensure that the surface to be painted is free from any loose paint, and filling the surface imperfections such as holes, dirt, fine cracks are to be filled with wall putty or mixture of white cement and fine sand (in the ratio of 1:3) complete all as specified and directed.
Taking down carefully aluminium/copper & Flamp proof point wiring (Light/ Fan/Socket or power) complete incl fitting fixture such as switches, sockets, ceiling rose, brackets, holders, bulk head fitting etc and making good disturbed surface of wall/ceiling etc., all as specified and directed.
Taking down main switch/MCB DB/AC enclosure/Three phase enclosure by disconnecting the electric supply all as directed at site.
Taking down old U/S sub main wiring of any size aluminium/copper including batten/conduit and making good disturbed surface to match the existing surface.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLSH in and including PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories for the following:-
(a) One light/fan/exhaust fan point controlled by one way 5 Amp switch
(b) One 3 pin /5 pin socket out let 5 Amp on independent board
(c) One 3 pin/ 5 pin socket out let 5 Amp same board
All as per srl item no. 58 above but for 3/5 pin socket outlet for 15 Amps on independent board with 2.5 sqmm FRLS PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.50 sqmm PVC insulated unsheathed solid copper conductor cable as earth continuity conductor complete all as specified & directed.
M&L for point wiring for hanger light complete with stranded copper conductor 2.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLSH in and including steel conduit ISI marked not less than 20mm dia with including 2.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed: -
(a) One hanger light controlled by one MCB/20 amp SP
(b) Two hanger light controlled by one MCB /20 amp SP
M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLSH in and including PVC conduit ISI marked not less than 25mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 4 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories complete all as specified and directed.
S&F switch piano, flush type / 5 Amp single pole one way complete all as specified and directed.
S&F ceiling rose surface bakelite/ 65x20 mm ISI Marked three terminal complete all as specified and directed.
S&F stepped type Electronic fan regulator flush type complete all as specified and directed.
M&L for exhaust fan 300mm size 1440 RPM single phase 240volt ,50hz with louvers,complete all as spacified and directed.
S&F Wall Fans AC single phase 230/240V of size 450mm sweep, complete and all as specified and directed.
S&F in ceiling recessed mounting Endura slim pro Plus 2x2 LED panel square type, slim, compact, LED edge lit panel fitting with opal diffuser and electronic driver complete of size 36 watt LED840MODe. Make- Havells odering code ENDURASLIMPROPLUS2x2PLR28/36WLED840MODor CG/Bajaj
S&F surface/wall mounting LED batten,extruded aluminium housing provided for efficient heat dissipatin with poly carbonate diffuser & intergrated electronoc driver including 20 watt LED lamp complete and all as specified and directed.
S&F stout plus LED complete fitting including 1x10watt LED tube suitable formirror light Complete all as specified and directed. Make- Havells Cat No- STOUTPLUS600BS20WLED857SPCWH/CG/Bajaj
S&F socket out let, flush type 5 pin 5 Amp complete and all as specified and directed.
S&F switch piano, flush type 15 Amp complete and all as specified and directed.
S & F socket outlet multi purpose 3 pin 15 Amp and 3 pin 5 Amp, flush type complete and all as specified and directed.
Taking down & refxing of LED high way/Flood light fitting of any watt complete with light fitting etc. removing materials deposit to store for keeping in safe custody till refixing.
.S&F sheet metal enclosures with socket plug top and MCB TPN,3 pole and neutral enclosure with a three pin and earth plug and socket complete with one triple pole MCB of 63 Amp ,440 volts complete all as specified and as directed.
M&L for sub main wiring using 4x10 sqmm PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including PVC conduit of size not less than32 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2x10 Sqmm as earth continuity conductor all as specified and directed.
S&F MCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 200 Amps, double door type suitable for MCCB as a incomer and MCBs as out going complete and all as specified and directed.
M&L for MCB DB of sheet metal enclosure double door type, single pole and neutral 8 way with 200 Amp rated bus bar 240V complete and all as specified and directed.
M&L for MCB DB of sheet metal enclosure double door type, single pole and neutral 4way with 200 Amp rated bus bar 240V complete and all as specified and directed.
S & F MCCB DPX 160 thermal magnetic of 63 Amps 4 pole 16 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240V 'C' Series 10 KA complete and all as specified and directed.
S & F MCB DP 40 to 63 Amp 240 Volts 'C' series 10 KA complete and all as specified and directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FRLSH of size 6.0 Sqmm of 4 run voltage rating upto and including 1100 Volts drawn in and including PVC conduit of size not less than 25mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed.
Taking down old U/S panel including main switch/MCB/MCCB etc complete all as specified and directed.
Taking down of U/S cable of any size complete all as specified and directed.
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core.and laid in trenches/passing through pipe/ducts or on pole with Fixing arrangemant complete all as specified and directed.
All as per item No 85 above but 35 sqmm 3.5 core
All as per item No 85 above but 95 sqmm 3.5 core
All as per item No 85 above but 400 sqmm 3.5 core
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply, installation, commissioning and testing LT panel board cubical outdoor type floor mounted, factory made 3.15mm MS sheet, conforming to IP-54, with front and back hinges door with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof and painted powder coated including 500 Amp rated bus bar 3 phase 4 wire system and wiring with suitable size of copper cable comprising and suitable foundation & following accessories :- INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 25 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 400 Amps. (ii) Digital Multifuctional panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x 96 mm (Model 4440) (ii) Phase indicator lamp[ LED type RYB-01 Set OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle having breaking capacity 16 KA and thermal setting from 80% to 100% and of following ratings :- (ii) 63 Amps - 05 No (iii) 63 Amps -01 Nos (Spare) (iv) PCC foundation (1:2:4) grading (1.5x1.5x0.5) CUM (v) Supply and fix time switches 415 V three phase of Amps rating with contactor fitted inside steel enclosure No-2
Supply, installation, commissioning and testing LT panel board cubical outdoor type floor mounted, factory made 3.15mm MS sheet, conforming to IP-54, with front and back hinges door with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof and painted powder coated including 600 Amp rated bus bar 3 phase 4 wire system and wiring with suitable size of copper cable comprising and suitable foundation & following accessories :- INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 36 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 400 Amps. (ii) Digital Multifuctional panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x 96 mm (Model 4440) (ii) Phase indicator lamp[ LED type RYB-01 Set OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle having breaking capacity 25 KA and thermal setting from 80% to 100% and of following ratings :- (ii) 160 Amps - 02 No (iii) 63 Amps -01 Nos (Spare) (iv) PCC foundation (1:2:4) grading (1.5x1.5x0.5) CUM (v) Supply and fix time switches 415 V three phase of Amps rating with contactor fitted inside steel enclosure No-2
M&L for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x6.0 mm thich buried directly in ground vertically to depth not less then 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.25mtr below normal ground level connected to glavanised steel strip 32 mm x6 mm by means of bolts, nuts check nuts and washers of glavanized steel and connected to panel as directed and including provision of concrete pit in PCC (1:3:6) type C1.pre cast RCC (1:2:4) type B1 cover slab54 cm x54cm x5 cm (Reinforced with 8 mm dia TMT bars @ 75 mm, centre to both ways ) with one nandle for lifting made out of 8 mm dia, MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade ) for watering, chacoal pr coke and salt in attemates layers, 40 mm bore glavanised steel tubing light grade for proection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR (2009) complete as specified and directed.
Excavation in trenches in soft/loose of soil not exceeding 1.5 metre deep and not exceeding 2.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes/pole foundation etc. all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed.
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply & laying sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 CM (8cm under the cable & 15 cm over the cable) and gently punned down to 18 cm thickness complete all as specified and directed.” Note:- Only punned thickness shall be measured & paid.
Supply & lay brick well burnt bricks sub-class 'B' locally available old size laid flat across the lenght of trench for protection of cable completed all as specified and directed.
M&L for PCC(1:2:4:) type B-1 using 20mm graded stone aggregate as in base support of struts and other similar location etc with and including all necessary form work complete all as specified an directed.
Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided,etc complete all as specified and directed.
Dismantling and taking down unserviceable aluminium air termination rod and earthing strips etc all as directed
Dismantling and taking down unserviceable GI strips and aluminium strips
S & F air termination single pointed Aluminium rod, single pointed at top and properly threaded at bottom end 300 mm long, 12 mm dia complete all as specified and directed.
M & L lightening conductor aluminium strip 25x 3.15mm with sadles and fixing screws etc for roof conductors above ground complete all as specified.
M & L lightening conductor galvanised iron strip 32x 6mm drawn in Gl pipe and buried in ground complete all as specified.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw complete all as specified and directed.
Supply and install hi wall split units indoor / outdoor type AC complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating inverter type of capacity 1.5 TR including following items:- (a) Fixing only cooling unit with grouting nuts, bolts, cutting groove to wall for gas pipe and water drainage pipe complete all as specified and directed at site. (b) Fixing cutting, bent to shape copper pipe of appropriate size from out door unit to indoor unit by cutting hole to wall including brazing the copper pipe of appropriate size all as required at site. (c) Insulation of both the copper pipe with insulating material and covering the complete pipes with PVC casing and capping of size 75x75mm for mechanical protection of copper pipe complete. (d) S&F MS Bracket and fasterner suitable for out door unit of spilt type AC
Supply and install hi wall split units indoor/outdoor type AC complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating inverter type of capacity 2.0 TR including following items:- (a) Fixing only cooling unit with grouting nuts, bolts, cutting groove to wall for gas pipe and water drainage pipe complete all as specified and directed at site. (b) Fixing cutting, bent to shape copper pipe of appropriate size from out door unit to indoor unit by cutting hole to wall including brazing the copper pipe of appropriate size all as required at site. (c) Insulation of both the copper pipe with insulating material and covering the complete pipes with PVC casing and capping of size 75x75 mm for mechanical protection of copper pipe complete. (d) S&F MS Bracket and fasterner suitable for out door unit of spilt type AC
Supply and fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 130V to 300V with output voltage stabilized at 230 V with accuracy of +- 2.5 % and of capacity 3 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of +- 2.5 % and of capacity 5 KVA complete all as specified and directed.
M& L for earthing with galvanised steel pipe Electrode 40mm bore, medium grade,2.5 Mtr length buried directly and preferably vertically in ground with top edge note less than 1.25mm below normal ground level earthing lead of GI Strip 32x6mm galvanised iron/steel surrounded from all sides by mixure of charcoal and and comman salt and electrode connected to and including galvanized GI wire of dia 4 mm size by means of bolts, nuts check nuts washers, steel and earth wire procted by GI protection pipe medicum grade 40mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm bore for wartering funnel with wire mesh PCC chamber pit in PCC (1:3:6) type C-1, 40mm thick Precast RCC M-25(design mix) cover reinforceed with 8mm dia TMT bars, @10 Cm C/C on both sides and handle, excavation and earth work in any type of soil and removal up 50 m complete all specified and shown in electric plate No.2 connecting to earthing test point all as directed including testing on completion.
M&L for scrapping out loose mortar / concrete by chiseling / wire brushing complete and applying rust removing solution (rebaklene solution) to exposed corroded reinforcement and applying a coat of epoxy primer (Nitozink primer from M/s Fosrock or equivalent as approved by GE) as per manufacturer’s instructions and fixing of hard drawn steel wire fabric and tying with including mild steel wire (annealed) not less than 9 mm in dia and apply 25 mm average thickness in cement concrete type B0 ( 1:2:4) (using 12.5 mm graded stone aggregate) mixed with liquid integral water proofing compound etc. complete all as specified and directed. Note:- Hard drawn steel wire topic and liquid water proofing compound shall be measured and paid separtely.
Supply only hard drawn steel wire fabric n. Exc. 4 kg Sqm cut to lengths, bent to shape required completed all as specified and directed.”
Supply only liquid water proofing compound.
Supply only water proofing compound.
garg construction company
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .