Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 May 2023, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
REPAIR/ MAINT OF EXTERNAL ELECT SUPPLY NETWORKS (OH AND UG) INCLUDING LT PANELS OF MH MD AREA UNDER GE GOLCONDA
2023_MES_592581_1
8702/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
HYDERABAD
As Per Tender
9 documents required · 9 mandatory
₹500
GE GOLCONDA
₹60,000
Yes
30 May 2023
1 May 2023
29 May 2023
1 May 2023
27 May 2023
15 May 2023
Amount
M & L Prestressed concrete pole, 9.0metres long 152mm x 152mm at top and 152mm x 260mm at bottom,class 9 including excavation and PCC work for foundation including taking down carefully the exisitng unserviceable Prestressed concrete Pole, serviceable street light fitting and ACSR conductor and connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed. Note: (i) Rate quoted by the contractor shall deemed to includes excavation and earth work, 150mm thick PCC (1:4:8) type D2 (osing 40mm graded stone aggregate) below ploe and filled in trench up to 20cm above ground.
M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 2 Core 6 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed.
All as per item No.03 above but of size 2 core 10 Sqmm
All as per item No.03 above but of size 4 core 10 Sqmm
All as per item No.03 above but of size 4 Core 16 Sqmm
All as per item No.03 above but of size 3.5 Core 25 Sqmm
All as per item No.03 above but of size 3.5 Core 35 Sqmm
All as per item No.03 above but of size 3.5 Core 50 Sqmm
All as per item No.03 above but of size 3.5 Core 70 Sqmm
All as per item No.03 above but of size 3.5 Core 95 Sqmm
All as per item No.03 above but of size 3.5 Core 150 Sqmm
Supply & Laying 80 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
Supply & Laying 50 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 35 sqmm to 70 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed.
S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 95 sqmm to 150 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed.
S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 185 sqmm to 240 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed.
S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 35 to 70 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed.
S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 95 to 150 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed.
S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 180 to 240 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed.
Supply, Fixing and stringing ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator on overhead line including taking down of existing conductor complete all as specified and directed.
M&L Mild steel Cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclusive of one coat of red oxide zinc chrome primer and two coats of aluminium paint and removing the existing cross arms etc complete all as specified and directed.
Stringing only ACSR Conductor of type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed .
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulator complete all as specifeid and directed.
M&L Shakle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing insulator complete all as specified and directed.
S&F Stay assembly complete with accessories as shown in electric plate No.1, stay rod 16mm dia, loop type insulator, stay clamps including excavation and earth work, PCC foundation etc., and taking out old unserviceable stay assembly complete all as specified and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 40 mtrs each and removing the same cleaning the site all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying of poles, cables in trenches and getting out in soft/loose soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed.
M & L for road crossing /drain crossing by adopting trenchless tunneling work through specified pipe jacking method by erecting the equipment true to the alignment and gradient by hydraulic pipe jacking technique including tunneling in any type of strata including hard rock, MS cassing pipe heavy duty of size 100mm dia 6mm thick in any length including jointing materials to carry LT UG cables of size upto 240 Sqmm and necesssary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and directed.
M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
S&F PVC separators suitable for LT over head line of 4 conductors all as specified and directed
M&L MCCB 415 Volts, 4 pole, Fixed type, 63A/100 Amps, with breaking capacity 16 KA with all connected accessories including taking out old un-serviceable MCCB all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 160 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 200 Amps, with breaking capacity 25 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 250 Amps, with breaking capacity 25 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 350/400 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed.
M&L for cleaning thoroughly LT distribution steel poles of any height and any description (Maximum 9 Mtr long) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed .
S&F in reapir Push buttons & Elements complete all as specified and directed.
Removing Existing unserviceable Analog voltmeter with electrical connections and supply, install and testing new analog voltmeter 0-500V complete all as specified and directed.
Removing Existing unserviceable Analog ammeter with electrical connections and supply, install and testing new analog ammeter 0-250A/100A with necessary wires & CTs complete all as specified and directed.
Removing Existing unserviceable Digital ammeter with electrical connections and supply, install and testing new digital voltmeter 0-500V complete all as specified and directed.
Removing Existing unserviceable Digital voltmeter with electrical connections and supply, install testing new digital voltmeter 0-500V complete all as specified and directed.
M&L for repair of existing LT panel outddor/indoor type by properly fixing loose/dislocated MS doors with provision of hinges or welding as necessary, provision of tower bolt as per as existing size including painting of internal and external surfaces with one coat of synthetic enamel paint of approved colour after preparation of old painted surfaces as required for smooth operation of panel and as directed by the Engr-in-charge (Size of Panel board n.exc 2.25x1.2x0.6 m) NOTE: Cost of MS sheet,Tower bolt, sliiding bolt as required is deemed to be included in the unit rate quoted.
M & L for Indoor cubicle type MCCB enclosure of suitable size made out of 2 mm thick CRCA sheet single door, front open type, and painting with one coat of red oxide primer and two coats of powder coated paint for MCCB of capacity 100 to 160 Amps with provision for entry /exit of suitable 3.5 core LT Cable and connecting incoming & outgoing LT cables complete all as specified and directed. Note : The scope of work includes removing of existing enclosure including MCCB and fixing new sheet metal enclouser on the wall with necessary screws, lugs etc. and refixing dismantled MCCB in it complete.
Supply and Fix in repairs On-load change over switch 4 Pole, 415V, 63A in sheet metal enclosure including taking down old unserviceable change over switch complete all as specified and directed.
Supply and Fix in repairs On-load change over switch 4 Pole,415V,100A in sheet metal enclosure including taking down old unserviceable change over switch complete all as specified and directed.
Supply, fix, connect, commission and test 3-Phase Heavy duty power capacitors MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirming to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable Multi core multistranded with necessary lugs for inter connection of capacitor bank upto 4 KVAR complete all as specified including disconnecting and removing existing unserviceable power capacitor bank all as specified and as directed.
Supply, fix, connect, commission and test 3-Phase Heavy duty power capacitors MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirming to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable Multi core multistranded with necessary lugs for inter connection of capacitor bank of 5 KVAR complete all as specified including disconnecting and removing existing unserviceable power capacitor bank all as specified and as directed.
Supply, fix, connect, commission and test 3-Phase Heavy duty power capacitors MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirming to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable Multi core multistranded with necessary lugs for inter connection of capacitor bank of 10 KVAR complete all as specified including disconnecting and removing existing unserviceable power capacitor bank all as specified and as directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 25x4mm by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia light grade all as specified and directed.
Mavee Syndicate
MOHAMMED MUMTAZ ENGINEERING WORKS
SAI ENGINEERING WORKS
M/S SRIDEVI ENTERPRISES
NAVANAND ENTERPRISES
Sri Lakshmi Enterprises
GVR ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .