Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC AWARD | |
| 2 | L2₹25.7 L+₹77,705 (3.12%)Rejected-Finance SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹28.2 L+₹3.3 L (13.2%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹23.4 L
EMD Value
₹46,800
Closing Date
24 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE DANAPUR CANTT PIN 801503
PROVN OF 10 X TOILET AND 04 X BATHROOM OF CONNECTING OR LINE WITH PATHWAY AT MUZAFFARPUR
2022_MES_565530_1
GE/DNR/T-62 OF 2022-23 / 8638/E8
Open Tender
Civil Works
Item Rate
180 days
MUZAFFARPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE DANAPUR
₹46,800
Yes
11 Jan 2023
26 Nov 2022
27 Dec 2022
26 Nov 2022
24 Dec 2022
12 Dec 2022
Amount
Surface excavation n. exc 30cm deep & averaging 15cm deep and getting out in soft/loose soil complete all as specified & directed.
Boring holes 5m deep and 300 mm dia of pile in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50 m complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 250 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for Hardcore of broken stone or boulder gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for plain cement concrete, 1:4:8 type D-2 Nominal Mix (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete or sub base of floors complete all as specified and directed.
M&L for providing reinforced cement concrete M-25 Design Mix using 20mm graded stone aggregate as in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal under reamed piles, mass concrete etc complete all as specified and directed
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M&L for providing reinforced cement concrete M-25 Design Mix using 20mm graded aggregate as in beams, cantilevers, bressmummers, lintels over 1.5 m span complete all as directed
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in Chajjas and like complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for providing reinforced cement concrete M-25 Design Mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item)
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No 14.00 but 6mm to 8mm dia complete all as specified and directed.
Ditto all as per item No 14.00 above but 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders complete all as specified and directed.
M & L for use and waste of formwork to sides of rough finished suraface of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges in rough finished flat surface of concrete complete all as specified and directed.
M&l for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as spd and as directed.
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished, square, rectangular or polygonal surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, opening in concrete wall, sides of RCC slab, RCC / PCC bends in walls or similar work thickness exc. 10 cm and not exc. 20 cm in rough finished surfaces of concrete complete all as specified and directed.
M & L for old size brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:4) in half bricks wall complete all as specified and directed
M & L for 10 mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces and finishing the surface even smooth without using extra cement complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed.
Extra over rendering or plastering for work in isolated width or in widths not forming part of general plastering such as in bands , sunk panels , cornices , skirtings ,drip moulds and similar works exe 15 cm but n. exc 30cm in width or girth including cutting to edges all miters and stopped ends etc.
M & L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and smooth without using extra cement complete all as specified and directed. Note:- Liquid WPC will be measured and paid separately.
Supply only water proofing compound (liquid), ISI marked.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L Preparing new plastered surfaces of wall and applying three coats of white wash etc complete all as specified and directed.
M & L Preparing new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L Cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) 100mm thick as in sub base finished even & fair etc complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate), as in sub base of floor finished even and fair Complete all as spesified and directed
M & L for water proofing treatment on non approachable / non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed :- (i) Properly cleaning and drying concrete surfaces. (ii) Applying a coat of oxidized bitumen based solvent primer @ 0.3 Kg / sqm. (iii) Applying evenly tack coat of industrial bitumen 85 / 25 grade @ 1.2 Kg / sqm. (iv) Laying unrolled over the bitumen coated surfaces polymeric water proofing membrane, hyperplas standard weight not less than 3 Kg / sqm with 100 mm over laps shall be sealed by flame as per manufacturer instruction. (v) Applying a coat of bituminous aluminium paint @ 100 gm / sqm over and including a coat of hot air blown grade bitumen of grade 85 / 25 @ 1.2 Kg / sqm duly sanded over polymeric membrane complete. Note:- The polymeric water proofing membrane shall be extended upto parapet walls and inserted in walls by cutting groove and making good with CM 1:3 complete all as specified and directed.
M & L Rendering 10 mm thick in cement mortar 1:4 on concrete surfaces mixed with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof slab complete all as specified and directed . NOTE: water proofing compound shall be measured and paid seperately
M&L for Antitermite treatment of soil under existing floors using emulsion @ one litre per hole ,300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand )to match the existing floors complete all as specified and directed.
M&L for two coat of pidifin 2k on surfaces all specified and directed.
M & L for joint free non skid ceramic colour tiles (square / rectangular) of 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exc. 0.38 sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed (1:6) etc complete all as specified and directed.
M & L for 450x300 x7 mm thick glazed ceramic tiles (Digital pattern) including highlighter colored as in dado/ skirting and vertical serfaces set&jointed in neat cement slurry and pointed in colored cement 0ver and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tiles complete all as specified and directed.
Solid PVC door frame of size 50mm x47mm made out of 5mm plain clour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S & F for Steel ventilator with top hung shutter including, hinges, peg stay, complete all as spesified and directed
S& F 3 mm thick figured glass pin headed and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed...
S&F 150 mm long extruded aluminum anodised barrel tower bolts of fabricated type complete all as specified and directed.
S&F for extruded Aluminium handles, fabricated type, anodized 150 mm size complete all as specified and directed.
S & F for Vitreous China wash basin white flat back size 450x300 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia,PVC flexible wastepipe of adequate length and dia and PVC connection 15mm size 450 mm length with brass CP nuts on both sides, complete all as specified and directed.
S&F for pillar tap 15 mm bore cast copper alloy fancy type chromium plated, cast copper alloy, screwed down, high pressure, with capstan head, with or without lettered "HOT" or "COLD" with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F for 15 mm bore concealed type stop cocks, cast copper alloy, screwed down, high pressure, with capstan head, fancy type, chromium plated, with long shank and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F for bib tap 15 mm bore cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe or for brass ferrule fixed to iron pipe etc. complete all as specified and directed.
S&F 15 mm dia PVC connection 450mm long with two PTMT nuts complete all as specified and directed.
S&F for brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I of 1000 Ltr capacitycomplete all as specified and directed.
S&F for PVC ball valves high pressure of brass with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed of 20 mmdia (min weight-210 gms) complete all as specified and directed
S & F for 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F MS Peg set of six powder coated as approved by GE
S&F for brass chromium plated shower rose 125 mm size fancy type with or without swelves joint fixed to iron pipe etc complete all as specified & directed.
S&F for 15mm bore angle cock, cast copper alloy CP, fancy type high presure with capstan head handle, screwed both ends for iron pipe of for unions all as specified
S&F in repair water closet white vitreous china ware Orissa pattern of size 580x440mm with integral foot rest ‘P’ or ‘S’ trap front or back inlet incl provision of PCC bedding type B1, 1:2:4 ( 20 mm graded aggregate) and connection pipes ( excluding flushing cistern but including flushing PVC pipe 32 mm dia ) complete all as specified and directed
S&F PVC valve less, syphonic action type flushing cistern of 10 ltr capacity, low level with inlet, ball valve, float and handle including brackets incl PVC connection 15mm dia 450mm long with CP brass nuts on both sides complete all as specified and directed
Supply and laying of 16 mm CPVC Pipes SDR 11 & Plain CPVC SDR 11 fitting on walls / ceiling or laying in floors inclding union, brass elbow, brass tee, MBTA, FBTA complete all as specified and directed.
Supply and laying of 20 mm CPVC Pipes SDR 11 & Plain CPVC SDR 11 fitting on walls / ceiling or laying in floors inclding union, brass elbow, brass tee, MBTA, FBTA complete all as specified and directed.
S & F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls with brackets etc complete all as specified and directed.
All as per item No 64.00 above but 75mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius provided with access door of 110 mm dia complete all as specified and directed.
S & F PVC (SWR) vent cowl of 100 mm dia complete all as specified and directed.
S & F 75 mm bore PVC (SWR) floor trap, plain with grating including jointing to waste pipe, all as specified and directed.
M&L Chequered cement concrete tiles (pre painted coloured, glossy, rubber moulded) 20 cm x 20 cm x 20-22 mm thick, set, jointed and pointed in neat cement slurry in floors ( with grey cement and pigments) over and including Screed bed or bedding of mortar (CM 1:4) 20 mm thick for laying floor finishes complete all as specified & directed.
M & L for Point wiring with PVC insulated and PVC unsheathed electric FRLS cable of 1100V single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including MS boxes / pressed steel zink coated 1.6 mm thick with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets, fan regulators etc for the following complete all as specified and directed:-
All as per item No 71.00 above but one light/fan point controlled by one switch complete all as specified & directed
All as per item No 71.00 above but one 5 Amps socket out let point on independent board controlled by one switch complete all as specified & directed.
All as per item No 71.00 above but wiring using 2.5 Sq mm single core copper conductor for one socket out let 15/16 amps point on the independent boardcomplete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and as directed.
Supply and fixing socket outlet flush type multipurpose 2 in 1, 3 pin 5 Amp, 230 volts complete all as specified and as directed.
S & F switch socket combination 2 in 1.3 pin 5 Amp flush type universal
S & F switch socket combination 2 in 1.3 pin 5 and 15 Amp flush type universal
S & F MCB single pole 6 to32 Amps 240 volts
S & F isolater SPN 63 Amps 240 volts
Supply and fixing double door SPN DB's eight way of powder coated DB's suitable for MCB's fitted with bus bar , neutral link , earth bar and Din ral as per existing finishing completeall as spd and directed.
M & L for ceiling rose surface bakelite, 65 x 50 mm surface type two to three terminals AC 240 volts complete
S & F fluorescent tube light fitting single tube 1x 36 W 230 volts surface mounted decorative mirror optic type with electric ballast bipin holder connector block including tube rod 36 wat etc complete with all accesssories internally pre wired and incl connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed.
Supply and fixing batten/angular fittings complete all as specified and directed.
Supply and fixing of 9 watt LED bulb complete all as specified and directed
S & F 1100 volt grade heavy duty cable 4sqmm twin core flat PVC insulated aluminium served with inner sheathed of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire
S & F Sub main wiring with two run single core multistandred copper conductor cable of size 4 sqmm drawn through in and incl rigid PVC conduit and conduit accessories dia not less than 20 mm with 1 sqmm PVC insulated unsheathed single core soild copper conductor 1100 volts as earth contunity complete all as specified & directed Note: two runs of cable, one run of earth wire and one run of PVC conductor shall be measured as one unit
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre below normal ground level) connected to galvanised earth lead strip of size 25 mm x 4mm of nuts. bolts check nuts , and washers of galvanized iron or steel including 40 mm dia. light grade GI tubing for protection of earth strip MS Sheet metal with wire mesh . watering GI pipe medium grade 20 mm dia , charcol or coke and common salt in alternative of 15 cm conpacted thickness all around the electrod with concrete earth pit of pcc 1:3:6 type C-1, .50 mm thick pre cast RCC (1:2:4) type B1, pit cover reinforced with 8 mm dia deformed bar and siitable handle made of 10 mm dia round bar and necessary excavation earth work in soft/loose oil and disposal or spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No 3 and all as specified and directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia complete all as specified and as directed.
Supply and fix gun metal gate valve screwed for 25 mm (1.0”) dia pipe complete all as specified and as directed.
RC GUPTA AND SONS
PAPPU ROY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .