Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC Acceptance | |
| 2 | L2₹12.4 L+₹1.4 L (12.8%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
1 Oct 2021, 6:00 pmClosed
Garrison Engineer (I) (CG)Ratnagiri
Military Engineer Services Garrison Engineer (I) (CG)Ratnagiri SLUY Shed Plot, W19-23, MIDC Mirjole, Ratnagiri - 415 639
PROVN OF BATHROOM CUM TOILET COMPLEX FOR IN LIVING SAILORS ACCOMMODATION AT ICGS RATNAGIRI
2021_MES_447972_1
8139/E8
Open Tender
Civil Works
Item Rate
180 days
RATNAGIRI
As per the tender document
8 documents required · 8 mandatory
₹500
GE (I) (CG) RATNAGIRI
₹29,000
Yes
12 Nov 2021
3 Sept 2021
2 Oct 2021
3 Sept 2021
1 Oct 2021
17 Sept 2021
Amount
Surface excavation not exceeding 30cm deep & averaging 15 cm deep and getting out in soft/disintegrated rock all as specified and directed.
Excavation in trenches in soft/disintegrated rocks not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/disintegrated rocks in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site Hard rocks shall be broken in small pieces before refilling) all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers not exceeding 25cm, watering, & removing surplus soil to a distance not exceeding 50m & making good surface in soft/disintegrated rock all as specified and directed.
M&L 50 mm thick Sand filling under floors or in foundations including watering and consolidation all as specified and directed.
Removing excavated surplus soft/disintegrated rock obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Removing execavated rock to a distance exceeding 250mtr but not exceeding 500 mtr and depositing where directed.
M&L hard core of gauge n.exc 63mm , degorited spread and levelled in layers not exceeding 15mm thick watered and rammed to a tree surface with broken stone or boulders all as specified and directed.
M&L PCC 1:3:6 type C2 (40 mm graded aggregate) as in foundation , filling and mass concrete all as specified and directed.
M&L PCC 1:2:4 type B1 (20mm aggregate ) as in coping, benching/forming channel in manholes all as specified and directed.
Material and labour for precast reinforced cement concrete type B1, 1:2:4 using 20 mm graded crushed trap stone aggregate set in CM 1:6 as in MH cover slab cmplete all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
M&L for Reinforced Cement concrete (Nominal Mix) 1:1.5:3 type A1 using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like all as specified and directed.
M&L for Reinforced Cement concrete (Nominal Mix) 1:1.5:3 type A1 using 12.5 mm graded aggregate as in Chajja all as specified and directed.
M&L for Reinforced Cement concrete (Nominal Mix) 1:1.5:3 Type A1 using 12.5 mm graded aggregateas in cills lintel band etc. all as specified and directed.
Supply only Integral Water Proofing Compound and used as per manufacturer instruction all as specified and directed.
M&L damp proof course to horizontal or vertical surfaces including necessary form works in cement concrete 1:2:4 type B0 ( using 12.5mm graded stone agg) 40mm thick including water proofing compound and applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq.m all as specified and as directed. Note : Water proofing compound shall be measured and paid seperately.
M&L for Machine cut Laterite stone masonry as block-in-course masonry well bonded exc. 10 cm in width and setting in cement mortar 1:4 all as specified and as directed.
Granite of 20mm thick (any type )of work (table rubbed and polished) in steps , jambs , pillars , window cills cooking platforms and like in cement mortar 1:4 including pointing in white cement (1 :2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exceeding 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat all as specified and directed.
Formwork to chullah hoods, chajjas, troughs & similar items including edges Rough finished surfaces of concrete flat all as specified and directed.
Formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top and bottom rails. MS frames shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement supplying & fixing in the frame at site as per specification & drawing.
S&F solid PVC door frame of size 50mmx47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tune, supplying & fixing in opening as per specification and drawing.
S/F 200mm Aluminium, anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
S&F butt hinges of size 100 mm cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 all as specified & as directed.
S/F 125 mm Aluminium handles, cast type, anodised all as specified and directed.
S&F 20mm dia brass CP tabular towel rail 'D'Type 60 cm long between flanges all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified and directed.
M&L in TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than o.9mm dia or securing with clips CTD bars all as specified and directed.
M&L in TMT bar 6mm to 8mm dia cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips CTD bars all as specified and directed.
S&F Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) GDE Fe 410-0 W (Gde E-250) quality A all as specified and directed.
S&F Rolled mild steel Plates (plain or chequered) channels. Square cut or notched (ordinary & counter sunk) forming holes, without any attachment GDE Fe410-0 or Fe 310-O all as specified and directed.
S&F for MS Pipe of Square/rounde shape Steel work in tubular trusses including special shaped washer, cleats etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 all as specified ans as directed.
M&L Anodised Aluminium powder coated frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.(Minimum powder coating 50 Micron)
M&L Anodised Aluminium powder coated window and ventilator shutters, sliding/fixed type without sash bars, aluminium sections washing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing as per SSR complete shall as specified.(Minimum powder coating 50 Micron) Jindal Section
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / L or J type hook all as specified.
M&L 100mm thick PCC type B-2, (1:2:4) using 40mm graded stone aggregate,finishing cement concrete even and smooth using with out using extra cement all as specified and as directed.
M&L 100mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate all as specified and directed.
M&L cement concrete type B1 1:2:4 (20mm graded aggregate) as in sub base of floor 25mm thick all as specified and directed.
M&L glazed ceramic tiles rectified 600x 600 x 7 to 8 mm thick in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M&L glazed ceramic tiles rectified 600x 600 x 7 to 8 mm thick in skirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M&L Machine pressed precast concrete Pre polished interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade all as specified and directed.
M&L rendering 10mm thick in CM 1:4 as backing coat of tiles all as specified and directed.
M/L for rendering 15mm thick in cm 1:4 on concrete roof and chajja surface to get a uniform level surface for laying of membrane treatment on fair faces of brickwork or concrete surface all as specified and directed.
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling all as specified and directed.
M&L rendering 15mm thick in CM 1:6 on surfaces other than fair face of brick work finished even and smooth using sagol finish all as specified and directed.
M&L rendering(10mm+5 mm) thick on fair faces of brick work or concrete surfaces in CM 1:4 in two layers, 10 mm thick backing coat in CM 1:4 and 5mm thick finishing coat in CM 1:4 using integral water proofing compound all as specified and as directed. Note : WPC will be measured and paid seprately under relevant item of Sch 'A'.
M&L Screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6 all as specified and directed.
Applying two coats of white wash on Ceiling surface including preparation of new surfaces all as specified and directed.
M&L Preparing new plaster surface of wall of any description and apply two coats of oil bound distember over a coat of 3mm thick wall care putty all as specified and as directed.
M&L Preparing new plaster surface of wall of any description and apply two coats of exterior acrylic emulsion paint over a coat of primer in camoflauge pattern all as specified and as directed.
M&L Sheet glass, ordinary quality and glazing,4mm thick plain glass, n exc 0.5 sq.m in each pane all as specified and directed.
Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxid/zinc chrome all as specified and directed.
M&L for cutting of Extg CI/DI/GI Pipe line of size 50 mm bore with 25 mm brass ferrule for taking branch connection including all necessary fittings complete all as specified.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm dia laid in trenches all as specified and directed.
S&F tubes, medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor 15mm bore, all as specified and directed.
S&F tubes, medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor 20 mm bore, all as specified and directed.
S&F 50mm dia high density polyetchylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls/ or laid in floor all as specified and directed.
S&F 1000 Ltrs capacity rotational molded polythene water storage tank as loft tank(Rectangular) with closed top hoisted and fixed in position all as specified and directed.
S&F bib tap cast copper alloy chromium plated fancy type screwed for iron pipes or for brass ferrule of 15mm bore with capstan head all as specified and directed.
S&F 15mm bore fancy type pillar tap cast copper alloy chromium plated capstain head screwed down high pressure with long screwed shank and fly nuts for iron pipe (hot or cold) all as specified and directed.
S&F stop valve cast copper alloy chromium plated high pressure, screwed on both ends with iron pipe or unions, 15 mm bore fancy type all as specified and directed.
S&F 20mm dia gun metal ,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified and directed.
Supply and fix gun metal globe or gate Valves, size 25 mmdia with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed .
Supply and fix gun metal globe or gate Valves, size 50 mmdia with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F of Ball brass valves, high pressure, with polythene float and fly- nut com-plete, screwed for iron pipe or brass ferrule and fixed of 20mm dia all as specified and directed.
S/F waste fittings brass C.P for W.H.B 32mm dia, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed all as specified and directed.
S&F PVC connection of 15mm size with PTMT nuts of length 600mm all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints complete laid in trenches or in floors of 110 mm dia all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints complete fixed to walls of 110 mm dia all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints completelaid in trenches or in floors of 75 mm dia all as specified and directed.
S&F PVC (SWR) bends any radius of 110mm dia with access door all as specified and directed.
S&F PVC (SWR) bends any radius of 75mm dia with access door all as specified and directed.
S & F PVC (SWR) junction single, (Single T) equal or unequal of 110mm all as specified and directed.
S & F PVC vent cowl of of 110mm (SWR) all as specified and directed.
S&F cast iron nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) of 100mm dia. all as specified and directed.
M&L conccrete bed to drain pipes including packing under and haunching against the side of pipes after they are laid and tested 150mm bore of pipe, in cement concrete 1;3:6 type C2 (40mm graded aggregate) all as specified and directed.
M & L 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and directed.
Supply and fix galavanised steel tubes, light grade as cable protection laid on trench/floor fixed on pole/wall etc of 40 mm as specified and directed.
S&F vitrous china wash down water closet (pedastal pattern ) white, excluding flushing cistern, flush pipe & fixing bolts all as specified and directed.
S&F Vitreous China urinals, bowl type ( flat backl type), of size 465x355x265 mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement; fixing flushing cistern with brackets, flush pipe grating and union for discharge pipe all as specified and directed.
S&F wash basin vitreous china white (flat back) 550 mmx400mm size including cutting for and pinning in ends of brackets or erecting stand and inclusive of fixing of supply and 32mm dia waste pipe excluding taps, waste, chain and plug and porcelain stopper all as specified and directed.
S/F 125mm brass Chromium plated shower rose with or without swivel joints, including fixing to steel pipe or union all as specified and directed.
PVC valveless ,syphonic action type flushing cistern 10 Ltrs capacity low level ,with inlet , ball valve , float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern all as specified and directed.
S &F Plastic seat cover for EWC closed pattern, flat bottom with MS chromium plated or aluminised hinging device all as specified and directed.
M&L for water proofing treatment to RCC roof slab as specified below and as directed by Engineer-in-Charge:- (a) The roof surface shall be thorougly wire brushed cleaned to eliminate all sharp projection, washed dried up and cleanded of all foreign material and dust to receive primer. (b) on the dried plastered surface one coat of approved bituminious primer @0.25 Kg/Sqm shall be applied. (c) on this primered surface APP modified bituminious menbrane with non woven polyster mat reingocement weighing not less than 3.50 Kg/ Sqm with plain finish shall be laid by torch application method (d) Apply a coat of bituminious aluminium paint @ 0.15 Kg/Sqm (e) The overlap while torching shall be 75 mm on length side and 75 mm on width sideof manufacturer instructions. (f) The treatment shall be carried as per manufacturer's instructions.
S&F stainless steel soap dish any type fixed to plug with CP brass screwed all as specified and directed.
Supplying and laying un-reinforced pre cast concrete cable cover of class LV type 1 flat size 250 mm x 150 mm x 40 mm fixed in replacement of any type bricks or PCC covers all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core all as specified and directed.
M&L for point wiring complete with proper colour code, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694:1990, Part II with ISI marked and including PVC conduit medium grade not less then 25 mm dia, ISI marked with all accessories on surface conduit in wall/ celling/ floor/ roof etc, incl PVC rectangular box of suitable size with PVC top sheet, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
One light point controlled by one switch.
One ceiling fan / Exhaust point controlled by one switch.
One three pin switch socket 5 amps outlet on independent board.
One 3pin 5amps socket out let point controlled by one switch on same board with other switches.
M&L point wiring using proper colour coding complete all as specified with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed cable confirming to IS-694:1990, Part-II, ISI marked with multistranded copper conductor in and including PVC conduit medium grade not less then 25 mm dia, ISI marked with all accessories on surface conduit in wall/ celling/ floor/ roof etc, incl PVC rectangular box of suitable size with PVC top sheet, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth doly for 15 Amps, 3 Pin, socket outlet independent all as specified and directed.
S&F switch socket combination 2 in 1 , 5 pin 5 Amps 240 Volt flush type all as specified and directed.
S&F switch socket combination multipurpose 6 pin 16 amps flush type all as specified and directed.
Supply and fix 4 pole MCCB 25 Amp 50 Hz 415 Volt with rupturing capacity 25 KA all as specified and directed.
S&F MCB SP 6 to 20 Amps all as specified and directed.
S&F MCB TPN 32/40 Amps all as specified and directed.
S&F Singl pole and neutral enclosure with a two pin and earth plug and socket comolete with one single pole MCB 20 Amp all as specified and directed.
S&F MCB DB TPN 8 way, having degree of protection as IP 43- with metal door (double door), 415 V, complete with 100 amps rated copper bus bar and neutral link with provision for MCCB 4 pole as incomer and SP MCBs as outgoing all as specified and directed.
S&F LED tube light fitting 1x18 watts tube including 18 W LED tube all as per Shakti Model No.: SZSLBMX018 for batten and including 18 w LED tube including necessary connection etc complete all as specified and directed.
M&L for earthing using GI earthing wire of 4 mm dia complete with galvanised steel wire earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI wire of size 4mm dia to the extend 7.5mtr as earth lead by means of GI bolts, nuts etc with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI pipe 20mm dia (medium grade) earth lead protection pipe 15mm dia medium grade with bends , elbow etc from earth plate to test point, excavation and earth work in any type of soil returning , filling , ramming and removing of soil to distance not exc 50 mtr , making good to match with existing surface making PCC pit (earth chamber)having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm with RCC reinforced cover 50 mm thick and testing on completion including making test point on wall as per SSR specification all as specified and directed.
Supply and fix exhaust fan, AC single Phase230V , 300 mm sweep with louvers metal body and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.
M&L for Geyser point wiring with 2 runs of single core PVC insulated FRLS unsheathed suitable for 1100 volts, multistranded copper conductor conforming to IS:694:1990 with ISI marked cable of size 6.0 Sqmm and one run of 1100 Volts grade PVC insulated FRLS unsheathed 6.0 Sqmm multistranded copper conductor cable 1100 volts green colour as continuous earth conductor drawn in and including PVC conduit medium grade of size 25 mm dia , ISI marked for sub-main wiring on surface in wall/roof etc. with required accessories complete all as specified and directed.
M&L, clean, dry, unwashed sand filled in trenches / ducts for cushioning to cable including punning complete all as specified. Note : The depth of sand cushion after punning shall be measured.
M&L for construction of stone masonry valve pit as per of size 60 x 60 x60 cm (internal dimension complete with 50 x 50 x6 mm MS angle iron frame, 6 mm thick MS Top cover with locking arrangement including two coat of black bitumionous paint over a coat of red oxide primer on steel surface all as specified and directed.
SHRIKALP ENGINEERS AND CONTRACTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .