Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.2 Cr+₹4.3 L (3.61%)Rejected-Finance | ₹1.2 Cr+₹4.3 L (3.61%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.3 Cr+₹13.3 L (11.1%)Rejected-Finance | ₹1.3 Cr+₹13.3 L (11.1%) | L3 | Rejected-Finance Other than L1 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
10 Nov 2022, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per Tender Documents
2022_MES_553223_2
CWE/MTR/BPR/ OF 2022-23
Open Tender
Civil Works
Item Rate
365 days
GE Bharatpur
As per NIT
7 documents required · 7 mandatory
₹1,000
GE Bharatpur
₹2.0 L
Yes
20 Dec 2022
27 Oct 2022
12 Nov 2022
27 Oct 2022
10 Nov 2022
27 Oct 2022
Amount
M&L for surface dressing n. exc.15 cm deep in soft/loose soil complete all as specified and directed.
M&L for excavating over areas n.exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over area exc 1.5m but n.exc 3.0m deep and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches exc 1.5 mtr wide & not exc 1.5mtr in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, taking out/laying of pipe line etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches exc 1.5 mtr wide & not exc 3.0mtr in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc not exc 15 sqm on plan and not exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed.
M&L PCC 1:4:8 type-D2 (40mm graded aggregate) as in foundations, filling and mass concrete.sub base as in floors complete all as specified and directed.
Returning Filling in,including spreading, levelling, watering and well ramming in layers, not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material exc 50m& n.exc 250m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed.
M&L RCC Design Mix( M- 25 ) using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L RCC Design Mix( M- 30 ) using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and directed.
S&F CRS steel bars Fe 500D with T-guard Anti corrosive paint along with T- Guard WBP Primer 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto all as per item No 12 here in before but 6 to 8 mm dia.
Ditto all as per item No 12 here in before but 5 mm dia and over upto and including 10mm dia as in stirrups, spacers & binders.
M&L for RCC design mix M-25 grade using 20 mm graded stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L for RCC design mix M-30 grade using 20 mm graded stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter for rough finished flat surface complete all as specified and directed.
M&L RCC Design Mix( M- 25 ) using 20mm graded stone aggregate for column pillers, piers, post and struts complete all as specified and as directed.
M&L RCC Design Mix( M- 30 ) using 20mm graded stone aggregate for column pillers, piers, post and struts complete all as specified and as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions square,rectangular or polygonal rough finished flat surfaces of concrete complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L RCC Design Mix( M- 25) using 20mm graded stone aggregate in Beams, cantilevers, bressummers, lintel beam etc complete all as specified and as directed.
M&L RCC Design Mix( M- 30) using 20mm graded stone aggregate in Beams, cantilevers, bressummers, lintel beam etc complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams , beam haunchings, girders, bressummers, lintels, cantilevers,shelves including supports, overhangs, etc also splays between floors and beams, etc for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete Design Mix( M- 25 ) using 20mm graded stone aggregate as in chajja complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas troughs and similar items including edges rough finished flat surfaces of concrete complete all as specified and directed.
M&L RCC Design Mix (M- 25) using 20mm graded stone aggregate as in slab supported on walls, beams and columns in floors , roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC Design Mix (M- 30) using 20mm graded stone aggregate as in slab supported on walls, beams and columns in floors , roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs,landings and similar works : not exceeding 200mm thick (horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces by using m-crushed sand/ river sand finished surface even and fair complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surface of slab, beam & ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:3 on top surface of slab, beam surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in two coats 5mm thick rendering in cement mortar 1:4 with mixing WPC @3% by wt of cement over a 10mm thick layer in cement mortar 1:6 on rough faces of brick work or concrete surfaces as in external surfaces of wall finished fair even and smooth complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
S&F, Steel rolling shutters of 1.25mm thick lath , without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; errected in position as indicated, complete; push pull or manual type complete all as specified and directed.
S&F ball bearing for rolling shutters complete all as specified and directed.
S&F factory made steel window / ventilator, ISI Marked with side hung shutter including projecting type hinges with steel handle and tower bolt and steel peg stay with glazing bar, dovetailed or welded with one shop coat of red oxide/ zinc chromate primer complete all as specified and directed.
All as per item No 39 above but without glazing bars. Note : Mild steel wire cloth shall be measured and paid separately under respective items.
S&F factory made steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel with one shop coat of red oxide/ zinc chromate primer complete all as specified and directed.
S&F 35mm thick factory made IInd class hard wood panelled door shutters (any numbers of panel) with panels of 12 mm thick BWR plywood having seven ply with commercial veneers on both face of BWP grade and boded with phenol formaldehyde synthetic resin adhesive ISI mark. The size of rail & stile as per IS :1003 (Part-I) kilnseasoned and chemically pressure treated complete all as specified and directed.
M&L 35 mm thick factory made glazed and skeleton shutters of 2nd class HW open rebated and prepared to receive glass/gauze (without sash bar) etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR pt-1 section 8.24 (a) complete all as specified and directed.
S&F MS framed work such as grills, cooler stand, grating, etc with ends of bars, shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work or water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
M&L for mild steel work as in bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required: hooks(stay), heavy, for large gates; hook and pintle hinges; large hasp and staples; chains; hand made sliding bolts; clamps; hold fasts wall ties; hooks for hanging fan; plain angle cleats for securing purloins to wood trusses or rafter; knee piece insert; two way and three way strap; plate washers and similar small articles conforming to Fe-290 Gde-E-165. Complete all as specified and directed.
S&F butt hinges 100mm medium weight cold rolled mild steel including necessary welding if required complete all as specified and directed.
S&F 150 mm long mild steel barrel tower bolts stove enameled black with bright bolt (ISI marked) complete all as specified and directed.
S&F Mild steel presses steel bow handle oval type stove enameled black of size 150 mm (ISI marked) complete all as specified and directed.
S&F MS sliding door bolt, plate type, 300mm long, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts & nuts, 4 on bolt plate and 2 on staple plate and fixed complete all as specified and directed.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of apreture 1.18 complete all as specified and directed.
M&L 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory made soild panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, all as per specification and drawing complete all as specified and directed.
S&F Aluminium anodized handles 150mm long fabricated type complete all as specified and directed.
S&F aluminium anodized barrel tower bolt of extruded section of size 150 mm long complete all as specified and directed.
S&F 75mm butt hinges medium weight cold rolled mild steel, ISI Marked, fixed to angle iron chowkats including necessary welding if required complete all as specified and directed.
M&L Prepration of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for Prepration of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for Two coats of Apex Weather Proof Exterior emulsion (Water Based 100% Acrylic) or approved equivalent grade paint using hand roller over one coat exterior grade wall primer on cement plaster, concrete ,including surface to be painted shall made free from any loose paint, dust, grease, fungus, algae, moss, shall not be removed .Color & Pattern /Color Combination of the paint shall got approved by GE. Complete all as specified and directed.
M&L for Hardcore of brocken stone gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick machine pressed set jointed with grey cement and pointed in neat cement slurry in floors laid over 15mm thick screed bed in CM (1:4) complete all as specified and directed.
M&L for screed bed or bedding layer of 20 mm thick cement mortar 1:4, for floor finished complete all as specified & directed.
M&L 20-25mm thick Kota stone slabs over and including 20mm thick screed layer in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & polishing complete all as specified and directed. Note :- Kota stone on treads of stair case shall be in one piece.
S&F coloured Non Skid ceramic tiles 7 to 8 mm thick, (Square / rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed.
M&L for Kota stone slab 18- 20mm thick (in full length one piece) in riser of steps, skirting, dado and pillar laid over and including 10mm thick plaster in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Note :- (i) The size of kota stone in flooring shall be 550 x 550mm (minimum). (ii) Kota stone on treads of stair case shall be in one piece.
M&L for Glazed ceramic glossy tiles (approved by GE)in vertical surface 450X 300X 7mm thick colored as in dado/ skirting and vertical surfaces set & jointed in neat cement slurry over and incl 10 mm thick cement mortar 1:4 and pointed in coloured cement to match the Shade, pattern, laying etc of tiles as directed at site complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 (Using 20mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed.
M&L APP based polymeric membrane not less than 3 mm thick, weighing not less then 3.50 Kg/Sqm, reinforced with polyster non-woven fabric (weighing) not less than 150gm/Sqm and upper side of membrane thermally insulated with while mineral gravel finish, uniformly embedded during manufacturing process thermally insulated shall be used. It shall be laid by torch application. Side overlaps shall be 75 mm and the ends shall be 100 mm and all overlaps and joints shall also be sealed by torch application. For parapets, membrane shall be taken to a height of minimum 300mm and then inserted inside the parapet in a grooves. The same shall be finished by a membrane flashing over a coat of cold applied bituminous primer confirming to IS : [email protected] per Sqm and applied a hot blown bitumin coat spread over primer @ 2.0 Kg/Sqm complete all as specified and directed.
M&L for screed bed or bedding layer of 10 mm thick in cement mortar 1:4, over roof surface and finished even & smooth without using extra cement complete all as specified & directed. Note : WPC will be measured and paid separately.
S&F vitreous china wash down water closet pan of European type of size 580 mm x 440mm white with integral foot rests and provn of lime concrete / lean cement concrete bedding, including plastic seat cover white with flat bottom and mild steel chromium plated or aluminium hinging device including 10 ltr capacity PVC valveless syphonic action type low level flushing cistern and 32mm dia PVC flush pipe including jointing to socket of flushing rim complete all as specified and directed.
S&F toilet paper holder brass chromium plated including fixing to wall complete all as specified and directed.
S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, bowl urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and Union for discharge pipe. (Inclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F Vitreous china wash basin white flat back size 630 x 450mm size, incl cutting for and pinning in ends of brackets or erecting stand but inclusive of fixing of supply and waste pipe complete all as specified and directed.
S&F chromium plated fancy type pillar taps cast copper alloy with capstan head screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F bib taps 15mm bore chromium plated fancy type cast copper alloy with crutch of butterfly handle screwed down for iron pipe complete all as specified and directed.
S&F brass chromium plated tubular towel rail 20mm dia 'D' type, 60cm long between flanges complete all as specified and directed.
S&F Grating square 150 mm size of PTMT (Minimum weight 100gms) complete all as specified and directed.
S&F 100mm PVC (SWR) pipes single socketed, including fittings in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 100mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets/ clamps etc of complete all as specified and directed.
S &F Rotational moulded polyethylene water storage tanks 500 Ltr (cylinderical vertical with closed top)with ball brass valves,high pressure , with polythene float and flynut complete, hoisted and fixed in position all as specified in SSR part - I complete all as specified and directed.
Supply, jointing & testing steel water tubing, medium grade galvanised with and including necessary pipe fittings/accessories like sockets, unions tees, elbows etc and fixed to or concealed in walls and ceiling or laid in floors, complete all as specified and directed of following sizes:-
25mm bore
15mm bore
M&L Preparaton of New or previously untreated steel surfaces of any description, over 10cm in width or girth not otherwise described and applying Two coat of synthetic enamal paint over a coat of red oxide/zink coat primer. Complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
M&L for Formwork to edges of concrete flats, treads breaks in floors, window cill concrete railling, opening in concrete walls floor and roof n.exc 20 cm wide and sides RCC / PCC band in walls horizontal and sloping and similar work with fair finished surface exc 10cm but not exc 20cm wide complete all as specified and directed.
M&L Rendering 22mm thick (First coat 12mm & second coat 10mm thick) in CM (1:3) finished even and smooth without using extra on fair faces of brick work or concrete surfaces (Bottom Slab & bottom of top Slab) complete all as specified and directed.
M&L Rendering 22mm thick (First coat 12mm & second coat 10mm thick) in CM (1:3) finished even and smooth without using extra on fair faces of brick work or concrete surfaces (internal wall) complete all as specified and directed.
M&L for chemically treating internally plastered surfaces of the sump with water proofing chemical such as FOSROC NITOBOND firmy mixed (base and hardener) applied at rate of 4.00 sqm/ litre, cleaning and preparing surfaces for applicationcomplete all as specified and directed.
S&F anodised aluminium frame for doors, windows, ventilators and partition wall with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L applying PVC waterbar as in joint of RCC concrete surface, complete all as specified and directed.
M&L cast iron pipes following size with spigot and socket ends centrifugally cast, Class LA in any length with run lead joint, laid in trenches complete all as specified and directed.
100 mm dia
150mm dia
M&L Mild steel TMT bars,10 mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L MMild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for providing TM bond ACB SBR styrene butadiene rubber based polymer bonding agent having specific gravity of 1.02) of the Thermax or equivalent of webac chemicals/chemco system in ratio as per recommendation of manufacturer total chemical not less than 5% by weight of cement for bonding old & new cementations surface for both horizontal & vertical surface of concrete complete all as specified and directed
M&L for providing and applying T-Guard ANTC of make Thermax or equivalent of wabac chemicals /chemco system as approved by the GE having high performance water based aliphatic protective coating (shade as approved by GE ) to exposed concrete or masonry surfaces after proper surface preparation cleaning of dust dirt etc system should be application of T-Guard of Thermax make of equivalent of webac chemicals /chemco system-water coverage @ 8-10 sqm/liter/coat on prepared surface and application of 2 coats of T-Guard AC of Thermax make or equivalent of webac chemicals/ chemco system at 260-280 microns DFT coverage @ 5 Sqm/liter/coat@ 200 microns WFT using suitable brush or roller complete all as specified and directed
Demolition of brick work or stone/bolder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm but n exc 4 sqm each complete all as specified and directed.
Dismantling asbestos cement corrugated or semi corrugated sheets as in roof covering complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc 15cm thick (below or above ground level) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
Taking up or down steel water tubing and connection including cleaning for refixing of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connection including cleaning for refixing of 20mm bore complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in roof slab of bldg etc complete all as specified and directed.
M&L for precast cement concrete 1:2:4, type B-1 (20mm graded aggregate) as in landing, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed.
M&L for concrete bed in cement concrete 1:4:8 type D-2 using 40mm graded aggregate crushed stone aggregate to drain pipe 150mm bore incl packing under & haunching against the sides after they are laid and tested complete all as specified and directed.
M&L for 150mm bore Reinforced concrete pipes class NP3 with one collar per length joint with CM 1:1 with spun yarn and tested in trenches complete all as specified and directed.
M& L for septic tank of 10 user, with and including excavation in ordinary soil, foundation in PCC 1:2:4, Brick work in 1:4, RCC slab covers incl RCC precast manhole covers having 6mm plate embeded all around reinforced cover with angle iron frame vent shafts and sludge chambers complete all as specified and directed and all as shown in TD No. CEJZ/2002/TD/S-2 sheet No 1/1.
Construction of soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 2.4M dia X 3.00.0M deep complete all as specified and directed and all as shown in TD No. CEJZ/2004/TD/S-35 sheet No 1/1
Dismantling the existing centrifugal pump set of capacity 50 HP with base plate including taking out Starter/LT panel and shifting the same to the new pump house building including installation complete all as specified and directed. Note : (i) Cost of foundation for pump set and Starter panel as per manufacturer shall be included in quoted rate. (ii) Testing will be done after installation as specified by Engineer-in-Charge. (ii) Suction and delivery pipe with accessories will be measured and paid separately. (iv) Earthing will be measured and paid separately.
Supply and fixing , testing and commissioning of centrifugal pump set, 1450RPM, 30HP squirrel cage induction motor (Copper wound) coupled with pump set electric driven, 415V, TP suitable for average head max 60mtr and discharge min 500LPM with cast iron impeller and gland packing sealing or above including complete all as specified and directed. Make : Kirloskar model No. DSM 65/32B or equivalent in CG/KSB as per particular specifications. Note : (i) Cost of foundation for pump set as per manufacturer shall be included in quoted rate. (ii) Testing will be done after installation as specified by Engineer-in-Charge. (iii) Suction and delivery pipe with accessories will be measured and paid separately. (iv) Earthing will be measured and paid separately. (v) Starters will be measured and paid separately. (vi) All control valves will be measured and paid separately.
Supply and laying and testing 150mm bore ductile iron pipe S/S with tyton joints Class K-7 confirming to IS-8329/2000 Centrally cast spun ductile iron pressure with spigot ends in any length including jointing and testing complete all as specified and directed. Note : DI fittings and joints shall be measured and paid for separately under respective item of BOQ.
S&F and testing CI foot ball valves of size 150mm dia heavy duty complete all as specified & directed.
S&F and testing sluice valve of class PN 1.6 of size 150mm dia CI body with forged brass spindle and cast iron wheel head, both ends flanged IS-14846 marked complete with neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and directed.
S&F and testing non return sluice valve of class PN 1.6 of size 150mm dia CI body with forged brass spindle and cast iron wheel head, both ends flanged IS-14846 marked complete with neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc complete all as specified and directed.
M&L for MS connecting pieces both end flanged and other end reducers/bell mouth pieces, bends, blanking plate, tapers any type and radius and angle, tee pieces, single branch, 'Y' junction, double branch, both end flanged including gas welding machine and electric welding to required length including required size of bends, tees, flanges, nuts, bolts and washers, rubber gasket etc for provision of water pressure head including lathe work finishing and painting with approved paint, all ends socket, all ends flanged of size upto 400 mm made out of MS plate suitable thick conforming to Fe 410-0 or Fe- 310-0 complete all as specified and directed.
M&L CI fittings such as Bends tapers any type,(Straight, bends, increasing, decreasing or double socket etc.),Tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc upto 600 bore(for header purpose) complete all as specified and directed.
Supply and fixing testing and commissioning of Chemical dosing system alongwith injector pressure 7 kg/cm² and output (flow rate 0-5 liter/hr of the following specification with complete accessories like lead tubing connecting ferrules check valves etc along with following complete all as specified and directed Note: (a) Preparation tank of net capacity 100 liter of FRP dosing tank 650mm x net height 375mm + conical 300mm gross height with stand 100mm consisting of (i) Water inlet line, (ii) Outlet with Y strainer, (iii) Drain, (iv) Over flow, (v) Control bottom for sludge deposition, (vi) Pot hole with cover, (vii) Level gauge, (viii) Agitator 120 w, 900 RPM, 1 phase flange mounted motor with plastic shaft and impeller (b) Service tank net capacity 100 liter of FRP dosing top dia 540mm x bottom dia 480 mm x height 575mm consisting of (i) Water inlet line, (ii) Outlet with Y strainer, (iii) Drain, (iv) Over flow, (v) Control bottom for sludge deposition, (vi) Pot hole with cover, (vii) Level gauge, (viii) Agitator 120 w, 900 RPM, 1 phase flange mounted motor with plastic shaft and impeller (provision of mounting arrangement on lid/wall
Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) including PP-R fittings in trenches/walls/cellings or laying in floors complete of size outer dia 25 mm including all fittings complete all as specified and directed.
S&F PPR Gate Valves (Brass Insert) of 25 mm bore complete all as specified and directed
Supply installation testing and commissioning indoor type , outdoor type, Self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 60KVAR (5 KVAr-1Nos, 10 KVAr-03 No, 25KVAr-01 Nos, with 7% detuned harmonics filter reactor ) with thirstier control module and MCCB 4 Pole of 36 KA of 1.5 time of rating current of capacitor suitable for each control and MCCB 4 ploe 160 Amp 36 KA as incomer including control CT & control wiring complete having following accessories including control wiring with HR FRLS copper wire complete all as specified and directed. (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TP 160 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar of suitable rating. (iv) 60KVAR (5 KVAr-1Nos, 10 KVAr-03 No, 25KVAr-01 Nos with thirstier control module and MCCB TP of 36 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned haRMonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 8 stage with Auto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No). (vii) Capacitor duty thirstier control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors. (viii) Induced air system provided with axial flow fan/ centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front.
Dismantling of 02 Nos existing pump sets along with starter box complete and deposited to MES store yard complete all as specified and directed.
M&L for pump set terminal to starter panel wiring complete with 3X16 sqmm (nominal core) PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core in HDPE pipe complete all as specified and directed. (03 run of 16 sqmm measured as 1 run) Make: Finolex /Polycab/Havells Note : (i) HDPE pipe will be measured and paid separately
Supply and laying of High density poly- ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 for column pipe to bore well of size 40 mm dia including necessary arrangements for coupling arrangement on top and bottom of HDPE pipe with pump and delivery pipe complete all as specified and directed.
Supply and laying of High density poly- ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 for column pipe to bore well of size 50 mm dia including necessary arrangements for coupling arrangement on top and bottom of HDPE pipe with pump and delivery pipe complete all as specified and directed.
Supply & spread locally available unwashed dry river sand for cushioning and covering the under ground cable in trenches complete all as specified and directed. Note :- Punning thickness shall be measured
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and directed.
Supply, install, testing & commissioning open well submersible mono block pump set 03 phase, 415V 50 Hz copper wound of capacity 3 HP with cast iron impeller and stainless steel shaft complete all as specified and directed.
S&F of DOL submersible starter for 3HP capacity 415 volts, 50 Hz in sheet metal enclosure complete fixed in outdoor type MS panel of 3.15mm thick with power coated finish of size 30CM X45 CM X30 CM mounting on wall in pump house complete all as specified and directed.
S&F of PVC insulated submersible cable water proof flat type 3 core with standard copper conductor cable, 04 Sqmm, 1100 volts grade including cable lugs/joints, connection to submersible motor and starter Box complete all as specifed and directed.
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to galvanised earth strip 32x6 mm by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil, removal of surplus soil and providing charcol dust & salt layers all around the earth plate complete all as specified and directed. Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5mm will be measured and paid separately under respective item.
M&L galvanised iron strips 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified and directed.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated unsheathed FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) drawn into and including rigid non metallic PVC conduit medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including anodised / Pressed steel terminal boxes 60mm deep and not less than 1.6mm thick for mounting switches, sockets, fan regulators etc duly painted on inside & out side two coats of black bituminous paint over a coat of red oxide primer with 3mm thick hylam sheet top cover complete for the following :-
One light/fan point controlled by one way switch.
One 3 pin 6 Amp socket point outlet on the same board with other switch.
One 3 pin 6 Amp socket point outlet on the independent board.
All as per item No 135 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 Pin 6 Amp multi purpose flush type 230 Volt complete all as specified and directed.
S&F switch Socket combinatin 2 in 1, 3 Pin 6 and 16 Amp multi purpose flush type 230 Volt complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amp 230 Volt grade complete all as specified and directed.
S&F 5 step type electronic fan regulator 2 module, 120/280 volt 450 watt capacity, socket flush type including connecting complete all as specified and directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board complete all as specified and directed.
Supply and fixing LED 20 watt LED tubelight fitting retro fit type with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed.Cat No LCTLN-20-CDL make: Cromption or equivelent iitem of other specified make listed as per Appx 'B' particular specification.
S&F ceiling fan (white) of 1200 mm sweep, 5 star rating copper wound with super energy efficient BLDC motor including remot,connecting wire PVC insulated twisted flexible 0.5 sqmm copper conductor canopy set, down rod, shackle kit, including all standard accessories complete all as specified and as directed by Engineer -in-Charge . Model No- Efficiencia Neo Make:-Havells or equivalent in make listed as per Appx 'B' to particular specification.
S&F exhaust fan of 380 mm sweep 900 rpm with suitable size of MS louvers duly painted , connecting wire PVC insulated twisted flexible 0.5 sqmm copper conductor including all standard accessories complete all as specified and as directed. Make: Havells Model: Turbo Force SP, or equivalent in make listed as per Appx 'B' to particular specification.
S&F exhaust fan of 450 mm sweep 900 rpm with suitable size of MS louvers duly painted , connecting wire PVC insulated twisted flexible 0.5 sqmm copper conductor including all standard accessories complete all as specified and as directed. Make: Havells Model: Turbo Force SP, or equivalent in make listed as per Appx 'B' to particular specification.
Supply & fix 35 watts LED street light fitings new generation energy saving ,environmental friendly ,long life,versatile pressure die cast aluminium IP66 with 10KV surge protection road way,luminaire with high power LED as light source and suitable drivers etc and connecting with 2 x 1 sq mm multistranded PVC insulated copper conductor from fittings to the ceiling rose and fixing to complete all as specified and directed. Cat No-LSTS-25-CDL/NL-M Make:-Cromption or equivelentitem of other specified make listed as per Appx 'B' particular specification.
Supplying, laying, jointing, testing and commissioning of LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of following sizes complete all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles / walls and in ducts etc. excavation, earthwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely.
16 Sqmm 4 Core
10 Sqmm 2 Core
120 Sqmm 3.5 Core
Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 415/240 volt of the following:-
4 way TPN with 200 amps rated busbar 415 volts (double door type).
4 way SPN with 200 amps rated busbar 240 volts (double door type).
S&F MCB with GI hardware fixed in DB's of the under mentioned type and rating of he following :-
MCB SPN 40 Amps, 240 volt,Category- C curve, 10kA rupturing capacity (ISI marked IS-8828)
MCB SP 6-32 Amps, 240 volts,Category- C curve, 10kA rupturing capacity (ISI marked IS-8828)
MCB SPN 6-32 Amps, 240 volt,Category- C curve, 10kA rupturing capacity (ISI marked IS-8828)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15mm dia pipe and GI Pipe 20mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of SSR 2009 (Part-I) including taking out old existing earthing complete all as specified & directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
M/S MAMTA CONSTRUCTIONS
M/S YATENDRA SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .