Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC Found 1st Lowest | |
| 2 | L2₹3.2 L+₹41,993.80 (15.0%)Rejected-AOC | L2 | Rejected-AOC Found 2nd Higher |
Tender Value
₹2.5 L
EMD Value
₹5,000
Closing Date
3 Aug 2022, 1:00 pmClosed
SUPERINTENDING ENGINEER, EDC, BANDA
CHILLA ROAD, INDIRA NAGAR, BANDA
ERECTION AND SHIFTING WORK OF 11 KV/LT LINES, INSTALLATION OF DIST. TRANSFORMERS AND OTHERS UNDER FULL DEPOSIT SCHEME UNDER EUDD, BANDA
2022_DVVNL_715763_1
EDCBNDA-20/2022-23
Open Tender
Electrical Works
Item Rate
180 days
BANDA
AS PER ANNEXURED
2 documents required · 2 mandatory
₹1,180
DVVNL
₹5,000
O/O SE, EDC, BANDA
11 Aug 2023
18 Jul 2022
3 Aug 2022
18 Jul 2022
3 Aug 2022
18 Jul 2022
1 Aug 2022
Amount
The work of RE-ERECTION OF 11 KV MAIN LINE DUE TO SHIFTING FED FROM NAWAB TANK FEEDER NEAR ABHISHEK SHUKLA HOUSE, R/O DHEERAJ NAGAR, BANDA, EXTENSION OF LT LINES AT VARIOUS PLACES AS NEAR SARASWATI BAKILA VIDYA MANDIR INTER COLLAGE, KYOTARA CROSSING, BANDA, JHEEL KA PURWA BETWEEN LALLAN RAJPOOT HOUSE TO BRIJLAL MALI HOUSE, BANDA, JHEEL KA PURWA BETWEEN ROHIT DWIVEDI HOUSE TO AWADHESH SAVITA HOUSE, BANDA, JHEEL KA PURWA BETWEEN BHAGWANDEEN VERMA HOUSE TO KK DIXIT HOUSE, BANDA, ERECTION/INSTALLATION OF 10 KVA CAPACITY SUB-STATION AT NEAR BABERU ROAD, BANDA & ERECTION/EXTENSION OF HT/LT LINES WITH 10/25 KVA CAPACITY SUB-STATIONS FOR ELECTRIFICATION OF VARIOUS PLACES AS DHEERAJ NAGAR, JAGDEV ARAKH KA PURWA (BAKSHA KURAULI), HEERA PURWA (DUREDI) (BADOKHARKHURD) etc. on 8.5/11 Mtr. PCC/STP Poles with ACSR Weasel/ABC/XLPE/PVC Conductors under FULL DEPOSIT SCHEME Year 2022-23 for under EUDD, BANDA, including the work of cartage of new line material from store to work site and also cartage of old/scraped line material & other from work site to store, details of the work as given below :-
Safe cartage of 8.5 Mtr. long PCC poles from ESC, Banda to respective site of work, including loading, unloading and dragging as per direction of supervision engineer.
Safe cartage of 11 Mtr. long ST poles from ESC, Banda to respective site of work, including loading, unloading and dragging as per direction of supervision engineer.
Safe cartage of line material Viz. weasel conductor, GI Wire, Cross Arm, Earthing, insulators, x-arm, earthing rod, ABC Cable, XLPE/PVC Cable, stay complete etc. from ESC, Banda to respective site of work, including loading, unloading and dragging as per direction of supervision engineer.
Erection & grouting of newly erected 8.5 Mtr. long PCC poles as single support structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge.
Erection & grouting of newly erected 8.5 Mtr. long PCC poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge.
Erection of newly erected 11 Mtr. long ST poles as single support structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge.
Laying, sagging, stringing, binding and jumpering of new ACSR Weasel Conductor on the erected poles in 33 KV/11 KV HT/LT lines as per site requirement.
Laying, sagging, stringing, binding and termination etc. of ABC Cable of various size on the erected poles as per direction of supervising engineer/RESSPO manual.
Laying, sagging, stringing, binding and termination etc. of XLPE Cable of 3x300 Sq.mm. on the erected poles as per direction of supervising engineer/RESSPO manual.
Laying, sagging, stringing, binding and termination etc. of 10 Sq.mm. PVC Cable Single Core on the erected poles as per direction of supervising engineer/RESSPO manual.
Fixing & Filling of jointing kit indoor/outdoor type for 11 KV as per norms.
Fixing of LT Distribution Box with all fittings as per norms.
Fixing of T-Off Channel with all fittings as per norms.
Erection and grouting of stay set including the work of nozelling etc. as per RESSPO manual and also including the cost of all grouting material.
Fixing of earthing rod as per direction of supervising engineer/RESSPO manual. including the cost of labour, T&P etc. required for proper completion of work.
Erection/Installation of 10 KVA Capacity Transformers on the newly erected single pole structure in proper alignment and as per direction of supervising engineer/RESSPO manual, along with carriage, loading & unloading from ESC, Banda to respective site of work.
Erection/Installation of 25 KVA Capacity Transformers on the newly erected double pole structure in proper alignment and as per direction of supervising engineer/RESSPO manual, along with carriage, loading & unloading from ESC, Banda to respective site of work.
Dismentling of old/damaged PCC/STP/Joist/Rail Poles released damaged broken material as per required work with cartage of poles/material.
M/s. SHIV SHAKTI INTERPRISES
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .