Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.7 LAccepted-AOC | ₹50.7 L | L1 | Accepted-AOC aggrement done on 19.03.2020 as per attached letter |
| 2 | L2₹61.9 L+₹11.2 L (22.2%)Rejected-Finance HANUMAN MANDIR KE PAAS WARD NO 06 BUDHNI DISTRICT SEHORE MP | ₹61.9 L+₹11.2 L (22.2%) | L2 | Rejected-Finance BEING L2 |
| 3 | Rejected-Technical ITARSI NARMADAPURAM MADHYA PRADESH INDIA | - | - | Rejected-Technical as per attached letter |
Tender Value
₹64.8 L
EMD Value
₹1.3 L
Closing Date
11 Feb 2020, 5:30 pmClosed
Deputy Director, Hydrometeorology
Deputy Director, Hydrometeorology Division No.2, Tawa Colony Hoshangabad, Hoshangabad- 461001
Construction of Divisional Data Centre Building under National Hydrology Project at Hosengabad, MP
2019_WRD_66481_1
708/2019-2020/National Hydrology Project
Open Tender
Civil Works - Buildings
Percentage
365 days
Hoshangabad
yes as per tender document
14 documents required · 14 mandatory
₹10,000
Yes
as per tender document
₹1.3 L
Yes
bhopal
13 May 2020
31 Dec 2019
12 Feb 2020
31 Dec 2019
11 Feb 2020
4 Jan 2020
10 Jan 2020
Amount
Boring providing and installing cast situ single under reamed pile of specified dia meter and length below pile caps in M20 cement concrete to carry a safe working load not less than specified. Excluding the cost of steel reinforcement but including the cast of boring concrete and the length of the pile to be embedded in pile cap etc. all complete (length of pile for payment shall be measured up to the bottom of the pile cap) including all leads and lifts. etc. complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Pile P2 dia 250
Pile P3 dia 300
Pile P4 dia 300
2 nos Bulb provide P2 piles
2 nos Bulb provide P3 & P4
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No extra lift is payable if work is done by mechanical means) including all lead & lift complete in all respect and disposal of surplus material ncluding all leads and lifts. etc including all leads and lifts. etc. complete in all respect as per specifications, drawings and as directed by the Engineer in charge. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level With 40mm nominal size graded stone aggregate including all leads and lifts etc. complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate (M 10)
Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc. including all leads and lifts etc. complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Cement Mortar 1:6 (1 cement: 6 sand).
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding up to floor two level including cost of binding wire, all wastages and lappages/ overlaps ( overlaps shall be provided as per requirement of IS 13920, IS 456 & SP 34 ) etc. complete. (Note:- Spacer bars ( chairs ) shall be paid separately as shown in the drawings and as per direction of Engineer-in- Charge) Thermo-Mechanically Treated bars.(TMT) FE 500 D conforming to IS 1786
Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc. including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Cement Mortar 1:6 (1 cement : 6 sand)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand : 4 graded stone aggregate 12.5mm nominal size).including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square meter on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. Including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
15 mm cement plaster on the rough side of single or half brick wall of mix: including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 1:4 (1 cement : 4 sand)
Providing and laying vitrified floor tiles in different sizes with water absorption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Size of Tile 600x600x9-10 mm
Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours shades, Except burgundy, Bottle green, Black, laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement : 3 sand) jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc. Including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Kota stone slab 20mm thick is riser of step skirting dado & pillars laid in 12mm thick cement mortar 1:3 & jointed with gray cement slurry mixed pigment to match the shade of the slab including rubbing &polishing complete stair case GP including all leads and lifts. Etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level and up to floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in Charge. M 20 –Grade Concrete
Centering and shuttering including strutting, propping etc. and removal of form for: including all leads and lifts. Etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Foundations, footings, bases of columns, etc. for concrete up to plinth level.
Suspended floors, roofs, landings, balconies and access platform.
Shelves (Cast in situ)
Lintels, beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral- staircases.
Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like.
Weather shade, Chajjas, corbels etc., including edges.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Rate includes recess cutting in floor and making good the same wherever required. Including all leads and lifts. etc complete in all respect as per Specifications, drawings and as directed by the Engineer in charge.
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including all leads and lifts. Etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
15 mm dia. nominal bore
25 mm dia. nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 500 litre capacity tank including all leads and lifts. Etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: including all leads and lift. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing brass bib cock of approved quality: including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 15 mm nominal bore
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, uPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete including painting of fittings and cutting and making good the walls and floors etc. wherever required : including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. New work (two or more coats) over and including water thinnable priming coat with cement primer.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate (M -7.5)
Supplying and filling in plinth with hard muram/hard copra under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : With 20mm nominal size graded stone aggregate including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. M 15 – Grade concrete
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 1:4 (1 cement : 4 sand)
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Hot finished welded type tubes
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Using M.S. angels 40x40x6mm for diagonal braces
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in- charge) 0.50mm +/- 5% total coated thickness (TCT) thick Zinc coating 120 gm. as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied up to 12 meter or as desired by engineer-in-charge. The sheet shall be fixed using self-drilling/self-tapping screws of size (5.5x55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, metered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. (a) For fixed portion, Anodized aluminium (anodized transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15)
For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodized aluminium (anodized transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness
Providing and fixing ISI marked aluminium butt hinges anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 100x75x4 mm
Providing and fixing ISI marked aluminium butt hinges anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: including all leads and lifts etc including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 75x63x4 mm
Providing and fixing aluminium tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 150x10 mm
Providing and fixing aluminium tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 100x10 mm
Providing and fixing aluminium pull bolt lock anodized ISI marked (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers etc. including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
Providing and fixing aluminium handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. Including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. 100 mm
Providing and fixing aluminium handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. Including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge: 75 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Twin rubber stopper
Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge.
75 mm diameter (minimum wall thickness
Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Bend 87.50 including all leads and lifts. etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. (i) PVC. plain bend-
75 mm bend
110 mm bend
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: including all leads and lifts etc complete in all respect as per specifications, drawings and as directed by the Engineer in charge. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Point wiring (excluding metallic switch box & sheet but including switches,sockes,lamp,holders,ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
Light Point/Fan Points.
a) Short point
b) Medium point
c) Long point
3 Pin 6 Amp socket outlet on Separate Board
b) Medium point
c) Long point
Call Bell / Buzzer Points
c) Long point
Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board. all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
a) 2x2.5 Sq.mm.
b) 4x2.5 Sq.mm.
c) 6x2.5 Sq.mm.
d) 8x2.5 Sq.mm.
Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.CASING AND CAPPING ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket / S.S Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside capping as per specification for all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
On Separate Board
B. Medium Point
C. Long Point
D. Extra Long –I
E. Extra Long –II
F. Extra Long –III
Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch, socket etc. as required for all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
3 Module
6 Module
8 / 9 Module
12 Module
16 Module
Supplying and drawing single core PVC insulated cable FR with copper multi strand conductor ISI marked in existing rigid PVC Casing-N-Capping / conduit in surface or concealed as per specification. all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
1 X 1.5 sq mm (a) 1 X 1.5 sq mm
1 X 2.5 sq mm (a) 1 X 2.5 sq mm
Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
Current Rating -160 Amps & 80% -100% adjustable all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS: 8828 : 1996, IEC : 60898 :2002 but without enclosures :- all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
SINGLE POLE (SP)
6 Amp to 32 Amp Rating
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with KA value rating 10 kA of approved make confirming to IS:13947-Part III : 1993 & IEC :60947- 3:2001 (without enclosures ) :- all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
FOUR POLE
Supplying of approved make TPN MCB DB Metal Double Door IP 43 protection with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032( exclusive of MCB & isolator ): all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
Fixing of MCB /MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only)
MCB / Isolator SP/DP
MCB /MCCB Isolator TP /TPN/FP
Labour charges for fixing sheet steel enclosures, MCB DB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. .complete :- all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
For S.No. 27.7.1 to 27.7.7 ; 27.8.1 to 27.8.3 & 27.9.1 of BOQ in Tender Document
Supplying and fixing as per specification Call bell / buzzer of approved make with necessary materials complete. all lead and lifts etc complete in all respect as per Specifications drawing and as directed by engineer-in-charge.
Ding Dong bell
Supplying and fixing of approved make step type Modular electronic Fan regulator including connection etc. as required on existing board all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
100 Watt (2 module)
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS:374/1979 with up to date amendments. all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
Ceiling Fan (5 star & ISI)-1200 mm Sweep
Supplying, erection and testing of approved make Wall Mounting fan complete with Wall Bracket ,canopy, blades, speed Regulator etc .A.C 230-250 volts with connections and including raw bolt/Anchor hole fastener etc. complete finished of approved as required. all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge. 400 mm sweep
Supplying, erection and testing of approved make 'Fresh Air Fan' AC 230-250 volts with connection and including frame bolt/Anchor hole fasteners etc. complete finished of approved as required. all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in- charge. 300mm sweep
Supply and fixing Led tube rod comprising of LED tube with non-integral / integral driver, 6500K color temp having 4000k to 6500k burning hrs life with minimum @ L 80, system lumen output should be minimum with efficacy > 80 lm/W. LED driver PF 0.90 & THD < 30%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL Approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. 2 Yrs. Guarantee certificate from manufacturer. all lead and lifts etc complete in all respect as per specifications drawing and as directed by engineer-in-charge.
1 X 18/20/22W, Non Integral with driver
Supplying and fixing street light with high power LED of 1 to 3 W each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp 4000k to 6500K & 50000 burning hrs life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminaire comprises of driver, PF 0.95 & surge protection 3KV. Housing made of pressure die cast aluminium with heat resistant flat glass / Lens type, IP65 protection. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c 50mm.dia G.I. Pipe bracket up to 2 mtr. long in required angle/shape, connection lead, testing etc to complete the job. 2 Yrs. Guarantee certificate from manufacturer. 60W,
Providing and fixing wooden board of suitable size (maximum 12" X 18" ) for fixing of house service Meter with necessary materials and connection testing etc. complete as per specification : all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge. Three phase Meter
Providing and fixing earthing arrangement with 16mm dia 2.5 meter long galvanized iron or steel rod electrode including packing of charcoal powder and salt as per specification watering pipe 19mm dia G.I. Connection, cover plate having locking arrangement on the top etc. complete with refilling the pit as required, including excavation of earth pit in soil/ soft rock. all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
Supply of XLPE Insulated power cable (confirming IS-7098 Part-I ) 1100 Volt grade, 1 core /2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
4 CORE ARMOURED 10 Sq.mm.
Laying of one number armored / unarmored power cable 1.1 kV grade of size not exceeding 25 Sq.mm in the existing masonry open duct as required. all lead and lifts etc complete in all respect as per specifications drawing and as directed by Engineer-in-charge.
Provision for Rain water harvesting
Provision for fire protection work
Water purifier (UV+RO+UF) + air cooler for office
Officer chair
Furniture office table,
Low back office chair
provision for tube well bore and all accessories complete for supply of water
carrer 1.5 tone AC EESL Voltas
Total Amount of GST
RAJESH RAI
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .