FAULT FINDING IN HT/LT CABLES INCLUDING REPAIR/ RENEWAL, REROUTING AND SHIFTING OF FAULTY / DAMAGED 11 KV TO 0.220 KV HT/LT CABLES WITH STRAIGHT THROUGH / END JOINTS, REPAIRS / renewal OF STREET LIGHTS, TIMERS, CONTACTORS, FILTRATION/ DEHYDRATION OF
2026_MES_799482_1
CWE(U)/D-32/2026-27
Open Tender
Civil Works
Works
180 days
HQ CWE (U) Delhi Cantt-110010
As per Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (U) Elect Supply
₹90,000
Yes
19 Nov 2026
19 Nov 2026
15 Dec 2026
19 Nov 2026
8 Dec 2026
3 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Testing the cables with high voltage DC testing machine and locating of underground 11 KV HT cable fault by using suitable fault locating equipment including detecting the fault, tracing the cable route, identifying and pinpointing the exact location of fault, complete all as specified and directed.
Note:
(a) 11 KV, HT cable & joints shall be measured and paid separately under respective items of schedule.
(b) Fault to the contractor will be intimated vide phone/e-mail /whatsapp. The Contractor has to rectify the fault within 12 Hrs, failure of the contractor to attend the fault beyond 12 Hrs, a penalty of Rs. 1000/Hrs will be recovered, fault will be rectified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done. | 15 | Each Job | - | - |
| 2 | Testing the cables with low voltage DC testing machine and locating of underground 1100 Volt LT cable fault by using suitable fault locating equipment including detecting the fault, tracing the cable route, identifying and pinpointing the exact location of fault, complete all as specified and directed.
Note:
(a) 1100 V, LT cable & joints shall be measured and paid separately under respective items of schedule.
(b) Fault to the contractor will be intimated vide phone/e-mail /whatsapp. The Contractor has to rectify the fault within 12 Hrs, failure of the contractor to attend the fault beyond 12 Hrs, a penalty of Rs. 1000/Hrs will be recovered, fault will be rectified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done. | 15 | Each Job | - | - |
| 3 | Supplying, laying, jointing, testing and connecting of 11 KV, 3 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multi stranded aluminium conductors, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in DWC pipe including jointing & testing of size 3 core, 300 Sq mm.
Note:
(i) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work.
(ii) The cost quoted is deemed to be included for repairs / rectification for damages done to the existing electrical / communication / water supply system / Sewage System during execution of work. | 90 | RM | - | - |
| 4 | -Ditto- all as per item No. 3.00 here-in-before but 3 core, 185 Sq mm | 100 | RM | - | - |
| 5 | -Ditto- all as per item No. 3.00 here-in-before but 3 core, 120 Sq mm | 100 | RM | - | - |
| 6 | -Ditto- all as per item No. 3.00 here-in-before but 3 core, 95 Sq mm | 100 | RM | - | - |
| 7 | Supplying, laying, jointing, testing and connecting of 1.1 KV, 1/3.5/4 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multi stranded aluminium conductors, IS 7098 marked, suitable for LT 1.1 KV(E) system, laid in trenches / ducts / encased in DWC pipe including jointing & testing of size 4 core, 16 sqmm.
Note:
(i) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work.
(ii) The cost quoted is deemed to be included for repairs / rectification for damages done to the existing electrical / communication / water supply system / Sewage System during execution of work | 100 | RM | - | - |
| 8 | -Ditto- all as per item No. 7.00 here-in-before but 4 core, 25 sqmm | 100 | RM | - | - |
| 9 | -Ditto- all as per item No. 7.00 here-in-before but 3.5 core, 50 sq mm | 120 | RM | - | - |
| 10 | -Ditto- all as per item No. 7.00 here-in-before but 3.5 core, 120 Sq mm | 120 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
BOQ_896988.xls
BOQ • 0.64 MB
D32TP.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .