Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹29.5 L+₹1.6 L (5.77%)Rejected-AOC PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-AOC Not Being Lowest | |
| 3 | L3₹29.6 L+₹1.7 L (6.17%)Rejected-AOC | L3 | Rejected-AOC Not Being Lowest | |
| 4 | L4₹30.4 L+₹2.5 L (9.10%)Rejected-AOC | L4 | Rejected-AOC Not Being Lowest | |
| 5 | L5₹33.7 L+₹5.8 L (21.0%)Rejected-AOC | L5 | Rejected-AOC Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Jul 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
EXTERNAL PERIODICAL SERVICES AND REPAIR/ REPLACEMENT OF DRAIN REPAIR, INTERLOCKING PAVOR BLOCK, CHEQUERED TILES, PARKING SHED AND FENCING ALONGWITH REPAIR/ REPLACEMENT OF INTERNAL WIRING, DB, MCB AND MISC E/M WORKS AT DK-I, 1 WEC AND ADJOINING AREA U
2024_MES_658850_1
GE/C-22/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
10 Sept 2024
10 Jun 2024
10 Jul 2024
10 Jun 2024
8 Jul 2024
24 Jun 2024
10 Jun 2024 - 24 Jun 2024
Amount
Demolition of brick work or stone masonry built in cement mortar in any position including segregating serviceable/unserviceable bricks/stones Complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
All as per Ser No 2 above but except bricks.
M&L for rendering 15 mm thick in CM 1:4 on any faces of concrete or brick surfaces finished even and fair without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over primer complete all as specifed as direted by Engr-in-charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc Complete all as specified and directed by Engineer-in-Charge.
Dismantling of PCC unreinfroced below or above ground level n.exc 15cm thickness.
M&L for providing 40 mm thick cement concrete 1:2:4 type B1 (20 mm graded aggregate) as in hard standing laid in alternate bays Complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block 60mm thick M-35 grade any shape and size with grey cement and pigment Complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floor or in foundations including watering and consolidation Complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick screed bed or bedding layer for laying floor finishes of tiles CM 1:6 Complete all as specified and directed by Engineer-in-Charge.
S&F Chequered cement concrete PU coated colourtiles 300cm X 300cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments Complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type C-1 1:3:6 (20mm graded aggregate) as in copings Complete all as specified and directed by Engineer-in-Charge.
Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground Complete all as specified and directed by Engineer-in-Charge.
Dismantling fencing wiremesh, any type Complete all as specified and directed by Engineer-in-Charge.
Excavation in post holes (or similar holes) n exc 0.5 cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm and covering and removal of surplus soil n exc 50m and making good surface Complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) in foundations, filling and mass concrete Complete all as specified and directed by Engineer-in-Charge.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc including embeding in concrete and similar work conforming to Fe-290 Gde-E-165 Complete all as specified and directed by Engineer-in-Charge.
S&F high quality zinc coated GI Chain link fencing of required width in mesh size 50x50 mm made of GI wire dia not less than 3mm and fix with column with nut or bolts and strengtheing with 10mm TMT bars, conforing to standard grade steel complete all as specified and directed. NOTE:- (i) Payment of TMT bar shall be made in seperate items in this Schedule. (ii) The Engr-in-Charge along with rep of contractor shall verify the weight mesh and submit the copy along with photographic eveidence along with RAR and Purchase Voucher. (iii) The quoted rate shall be inclusive of Nut bolt required.
S&F 10mm dia MS bars to be fixed in chain link fencing all as directed by Engr-in-Charge.
S&F in repair galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straning and fixing to fencing post with staple or steel pins etc Complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description Complete all as specified and directed by Engineer-in-Charge.
S & F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and framework for tank stagging and simillar items also fastening and fixing complete all as specified and directed by enginer-in -charge.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of syanthetic anamel paint over one coat of red oxide Complete all as specified and directed by Engineer-in-Charge.
Dismentling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering Complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished even and smooth without using extra cement in multistorey building,complete all as directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajja in multy storey building etc complete all as specified.
Material and labour for preparation of new plastered surfaces as of walls and applying Two coats of weather proofing exterior acrylic emulsion paint over one coat of primer from the same manufacturer white lime wash complete all as specified and directed.
M&L for new plaster surface two coat of oil bound destemper over 2-3mm thick of birla white putty including preparation of newly plastered surface etc all as specified.
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying one coats of cement base paint by spray gun/ spray machine up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+2 bldg including scaffolding
M&L for preparation of old decoreated external wall / internal wall/Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+2 bldg including scaffolding
M& L for preparing the entire surface with applying 2-3 mm thick wall care putty on walls and ceiling surface finished even and smooth complete all as specified and directed.
M& L for preparing the entire surface with applying priming surface with alklai resistance priming paint on walls and ceiling surface finished even and smooth complete all as specified and directed.
M&L for external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 3 storey bldg complete all as specified and all as directed by Engr- in-charge. Notes for item No 30, 35 & 36: (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted successful L1 bidder after opening of Financial Bid within a fixed time frame of 7 days otherwise tender will be cancelled. (d) A guarantee amount of 5% of contract of work done for item No 30, 35 & 36 of BOQ will be retained for 5 years of the completion of work.
M&L for Preparation of old painted surfaces of wood surfaces of any description over 10 Cm width or girth by applying sand paper etc for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 40 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover/Modular cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/Exh fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 42 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
Supply and fix white cover plate in replacement with frame 2 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate in replacement with frame 3 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate in replacement with frame 4 Module omplete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge.
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix in replacement surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and Fixing in replacement LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
Supply and fix in replacement MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB DP 63 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement Ventilating Fan 250 mm sweep, 1200 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing in replacement Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix in replacement wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA, 4 pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25mm dia non metalic rigid PVC conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn throughand including 25mm dia non metalic rigid PVC conduit in walls all as specified and as directed.
S&F in replacement plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F in replacement socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F in replacement PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F in replacement PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F in replacement Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll each roll should not be less than 90 mtr as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
Supply only in replacement SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only in replacement heating element of 2 KW for any type with nut bolt washer complete all as directed.
Supply only in replacement heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only in replacement replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
S&F in replacement 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Schedule of Credit
M/S Parmod Johar
M/s SAAR ENGINEERS
POONAM ENTERPRISES
ANSH VANSH CONSTRUCTION COMPANY
a.k constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .