Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.9 LAccepted-AOC | L-1 | Accepted-AOC Lower Rate | |
| 2 | L-2₹21.2 L+₹27,429 (1.31%)Rejected-AOC 577 C BLOCK YASHODA NAGAR YASHODA NAGAR KANPUR NAGAR UTTAR PRADESH 208011 | KANPUR NAGAR | UTTAR PRADESH | 208011 | L-2 | Rejected-AOC Higher Rate | |
| 3 | L-3₹21.5 L+₹59,234.50 (2.83%)Rejected-AOC 117 805 M BLOCK RAWATPUR KAKADEO KANPUR NAGAR UTTAR PRADESH 208019 | KANPUR NAGAR | UTTAR PRADESH | 208019 | L-3 | Rejected-AOC Higher Rate |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
5 Sept 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Construction Circle, RPH, Kesco,Kanpur
Attending breakdowns, construction, re-arrangement, shifting, replacement/repairing of damaged poles etc. and all related works under E.U.D.C-II, Kesco., Kanpur.
2022_KESCO_717025_1
11/Const./2022-23
Open Tender
Construction Works
Item Wise
365 days
EUDC-II, Kesco, Kanpur
Please refer tender document
2 documents required · 2 mandatory
₹3,540
Kesco
₹24,000
15 Feb 2023
25 Jul 2022
5 Sept 2022
25 Jul 2022
5 Sept 2022
25 Jul 2022
180 days
Loading, Carriage and unloading of ST poles including old & used S.T. Pole from store to work site or vice-versa.
Erection of repaired/new S.T. Pole size 9.0 Mtr. to 13.00 Mtr. with the help of crane including digging of Pit back filling and ramming
Dismentalling of damaged S.T. Pole of very critical position with the help of crane after removing all the accessories from damaged pole and its all related work including digging of pit or by cutting with gas cutter.
Erection of Single/Stud Pole including fitting of all material.
Erection of Double pole structure as per standard specifications with the help of crane including digging of Pit back filling and ramming
Erection of Double pole structure from existing Single Pole including fitting of M.S. Channel and other accessories etc.
Grouting of pole with cement brick ballast and coarse sand as per standard specification.
Making of pole plinth of 400 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of materials.
Painting of Steel Tubular Pole with one coat of red oxide and two coats of first enamel Alm. Paint upto fuse set including cost of all materials.
Earthing of supports as per standard specifications.
Fixing of stay rod and its erection and grouting by fitting of stay clamp. Stay wire and its proper binding and tightening etc.
Opening of H.T. Jumpers from the existing 3 Phase 3 Wire H.T. O.H. line for erection work.
Opening of L.T. Jumpers from the existing 3 Phase 4 Wire L.T. O.H. line for erection work.
Loading, Carriage and unloading of ACSR/ Panther Conductor from store to work site or vice-versa.
Loading, Carriage and unloading of Earth wire/G.I. wire from store to work site or vice-versa.
Laying, stringing, tensioning & final sagging of Earth wire/G.I. wire
Cross lacing of guarding by G.I. wire (approximate 5 lacing of each span)
Dismentalling of 33/11 KV V-Type X-arm/M.S Channel/ Guarding Angle/LT Bracket etc. from damage pole.
Excavation of ST pole (Old & Used) from ground by digging the pit or by cutting with gas cutter and its proper stacking.
Dismentalling of binding wire from insulators and loosening of the ACSR mixed conductor on each pole then lowering down the ACSR mixed conductor & rolling into bundles.
Taking out 11 KV/0.4 KV cable from drum/complete drum of cable from store its loading carriage and safe unloading by truck/bullock cart at site of work or vice-versa.
Digging of Trench for laying of 11 KV/0.4 KV cable in normal soil in size of 30 cm. wide and 1 to 1.5 meter deep.
Digging of Trench for laying of 11 KV/0.4 KV cable in kharanja soil in size of 30 cm. wide and 1 to 1.5 meter deep.
Digging of Trench for laying of 11 KV/0.4 KV cable in metallic road in size of 30 cm. wide and 1 to 1.5 meter deep.
Digging of Trench for laying of 33 KV cable in normal soil in size of 30 cm. wide and 1 to 1.5 meter deep.
Digging of Trench for laying of 33 KV cable in kharanja soil in size of 30 cm. wide and 1 to 1.5 meter deep.
Digging of Trench for laying of 33 KV cable in metallic road in size of 30 cm. wide and 1 to 1.5 meter deep.
Laying of MS Pipe in digged trench.
Laying of 11 KV /0.4 KV XLPE cable in above digged trench covering with bricks and back filling and proper ramming.
Laying of 11 KV/0.4 KV XLPE Cable through M.S. pipe in digged trench.
Laying of 33 KV XLPE cable in above digged trench covering with bricks and back filling and proper ramming.
Laying of 33 KV XLPE Cable through M.S. pipe in digged trench.
Making indoor/outdoor joints of 11 KV/0.4 KV XLPE Cable where the cable is being laid.
Making indoor/outdoor joints of 33 KV XLPE Cable where the cable is being laid.
Making 11 kV/0.4 kV straight through joint including digging of pit upto 1.1 metre depth
Making 33 kV straight through joint including digging of pit upto 1.1 metre depth
Digging of pit using JCB for making straight through joint 1mx1mx1m
Loading, carriage and unloading of Aearial Bunched Cable from store to work site or vice-versa.
Laying of HT Aerial Bunched Cable including fixing suspension clamp with eye hook , Dead end clamp with Eye hook on erected Steel Tubular Pole etc.
Laying of LT Aerial Bunched Cable including fixing suspension clamp with eye hook , Dead end clamp with Eye hook on erected Steel Tubular Pole etc.
Mounting & Erection of single phase distribution box of AB Cable with Piercing Connector, L.T. Bare Neutral Connector, Alu. Lug 25 mm, L.T. Cable 1x25 mm etc.
Mounting & Erection of three phase distribution box of AB Cable with Piercing Connector, L.T. Bare Neutral Connector, Alu. Lug 25 mm, L.T. Cable 1x25 mm etc. No.
Opening and reconnection of consumer service connections after replacement of line/ poles etc.
Erection of Distribution T/F on plinth/D/pole structure.
Connection of H.T. Jumper from fuse set to H.T. Bushing of the transformer.
Fitting of L.T. D.B. by brackets & clamps on double pole structure & L.T. Cable Connection from T/F Cable to L.T.D.B.
Connection of L.T. cable from L.T.D.B to L.T.O.H.
Dismentalling of existing distribution T/F (Upto 630 KVA)
Dismentalling of existing distribution T/F Fencing and erection and grouting of T/F Fencing on shifted T/F plinth
Making of H.T. Section points by brackets, clamps & Insulator, tightening of Line, binding of conductor & proper connection.
Making of H.T. Jumpers with 3 Phase 3 Wire H.T. O.H. line after erection of work.
Making of L.T. Jumpers from 3 Phase 4 Wire L.T. O.H. line for erection work.
Making section in existing Upper Busbar with ACSR Dog/Panther Conductor for dual source supply including mounting of disc insulator string.
Loading Carraige, Fabrication & modifications of M.S. Items as per requirement of site conditions.
Chopping of tree branches lying in the route of HT/LT line touching the tree branches to the phase line conductor making fault to the feeder, for 75mm dia to 450mm dia or as per requirement of site.
Fitting of Cross bracing on double pole structure and related work.
Deep Bore GI Pipe Earthing including supply Size GI Pipe 40mm dia B-Class 40 feet long with socket cutter, earth wire 7/14 SWG, Nut & bolts with connection of pipe to distribution T/F Neutral or Body all material shall be provided by contractor with cost of all material.
Deep Bore GI Pipe Earthing including supply Size GI Pipe 40mm dia B-Class 80 feet long with socket cutter, earth wire 7/14 SWG, Nut & bolts with connection of pipe to distribution T/F Neutral or Body all material shall be provided by contractor with cost of all material.
Fabrication, erection & grouting of T/F fencing of frame size 3x2.4 mtr. including cost of M.S. Angle size 40x40x5 and M.S. Flat size 35x5, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil and dust.
Carriage of all concerning stock material except mentioned above from Kesco. Store to site or vice-versa.
Connecting of newly erected network with Kesco mains including testing, commissioning and energization of the same completely.
Loading, Carriage and unloading of 33 KV VCB/OCB (including old & used) from store to work site or vice versa
Loading, Carriage and unloading of 11 KV VCB/LT ACB from Kesco store work site or vice-versa.
Loading, Carriage and unloading of battery Set 2 Volt 60 AH (15 Cell) from store to work site.
Loading, Carriage and unloading of Battery Charger from store to work site.
Taking out 33 KV cable from drum/complete drum of cable from store its loading carriage and safe unloading by truck/bullock cart at site of work or vice-versa.
Dismentalling of 33 KV cable box from existing 33 KV Jarjar VCB/OCB.
Connecting of 33 KV Cable box on newly erected 33 KV VCB after erection work.
Dismentalling of 33 KV indoor type VCB/OCB at control room including all related work.
Shifting of 33 KV VCB from unloading point to control room.
Shifting of 11 KV VCB from unloading site to meter room/Control room.
Shifting of 33 KV old & used indoor type VCB/OCB from control room to loading point.
Shifting of 11 KV old & used indoor type VCB/OCB from control room to loading point.
Erection of 33 KV VCB in control room.
Erection and grouting of 11 KV VCB/Control Relay Panel in meter room/control room.
Wiring, Testing and commissioning of newly erected 33 KV VCB and all related work.
Wiring, Testing and commissioning of newly erected 11 KV VCB and all related work.
Construction of Control Cable Trench as per standard specifications
Laying of Control cable in trench
Making riser from existing earth mate of control room for making earthing support to newly erected 33 KV VCB in control room.
Carriage of 11/6.6 KV S/G Panels/ Control Panel New & (Old & used) from Store to Site of work as and when required or back to store from site.
Dismentalling of jumpering from cable box to line, cable support switchgear panels.
Dismentalling of earthing of 11/6.6 KV S/G Panels/ Control Panel.
Dismentalling of connected cable box with S/G Panel/ Control Panel.
Opening of internal connection to 11/6.6 KV S/G Panels.
Dismentalling of old/damaged existing 11/6.6 KV S/G Pannels.
Connection of earthing of 11/6.6 S/G Panels.
Mounting of cable box on S/G Panels with handing of concerning cable and its proper fixing.
Making jumpers from cable box to line, cable support switchgear panels, section poles of each phase.
Laying of 11 KV 3x70 mm2 Cable /0.4 KV Cable (All size) Over head (Pole to Pole) with Fixing of Holding Clamp on existing /newly erected ST Pole
Laying of 11/33 KV 3x185 mm2 Cable Over head (Pole to Pole) with Fixing of Holding Clamp on existing /newly erected ST Pole
Laying of 11 KV 3x300 mm2 Cable Over head (Pole to Pole) with Fixing of Holding Clamp on existing /newly erected ST Pole
Laying of 33 KV 3x300/3x400 mm2 Cable Over head (Pole to Pole) with Fixing of Holding Clamp on existing /newly erected ST Pole
Dismentalling of Aerial Bunched Cable from L.T. O/H (damage) line.
Re-sagging of conductor, on old line after erection of pole, binding of conductor etc.
Laying, stringing, tensioning and binding of Weasel conductor for H.T./L.T. O.H.
Laying, stringing, tensioning and binding of Panther conductor
Fixing of guarding angle/guarding channel for laying of guarding
Cross lacing of guarding by G.I. wire (approximate 5 lacing of each span)
Restoration of Metallic/RCC road after proper repairing with appropriate materials.
Mounting of all types of cable box on pole as well as on H.T.P.B./Outdoor Metering Cubical/H.T.M.C. the work includes proper clamping of cable box on both ends with pipe provided by KESCo
Mounting of all types of cable box on pole as well as on H.T.P.B./Outdoor Metering Cubical/H.T.M.C. the work includes proper clamping of cable box on both ends without pipe
Making Plinth for H.T.P.B/ACB by brick work in size of 1.2x1 .2x1.0 meter as well as plastering of 12 mm thick on all the exposed sides of the plinth.
Loading, Carriage and unloading of H.T.P.B./ACB from store to work site and then after erection on the relay constructed plinth.
Making Plinth for L.T. P.B. By brick work in size of 1.2x0.75x1.0 meter as well as plastering of 12mm thick on all the exposed sides of the plinth.
Loading, Carriage and unloading of L.T.P.B. from store to work site and then after erection on the relay constructed plinth.
Erection of LTPB
Erection of HTPB
Erection of ACB
Construction of plinth for H.T. pilfer proof metering cubical.
Loading, carriage and unloading of H.T.Metering Cubicle from store to site or vice-versa.
Erection of H.T. metering cubical on plinth as per standard norms.
Dismentalling of H.T. pilfer proof metering cubicle.
Erection of L.T. metering cubical as per standard norms and connection of L.T. Cable including crimping of Lugs etc.
Erection of Tri-Pole structure including all fittings and proper alignment.
Erection of four pole structure including all fittings as well as proper alignment of structure.
Painting of M.S. structures fitted on pole such as channel, angle, brackets
Erection of O/D type Metering unit on D/P Structure.
Loading, carriage & unloading of O/D type metering unit from store to site & vice-versa.
Making of L.T. Shackle point by brackets, clamps, G.I. Shackle strips and insulators, tightening of line, binding of conductors and proper connections.
Disconnection of H.T./L.T. Lines, Shifting of T/F from ground/plinth to a safe place for construction of T/F plinth.
Shifting of T/F from ground to plinth or vice versa and re-connection/disconnection of H.T. L.T. Lines as well as earthing for proper completion.
Stringing of Single Core L.T. Cable
Stringing of 3 ½ Core L.T. Cable
Providing of one jeep gang with T & P on duty on special accessories.
Providing one paidal gang with T & P on duty on special accessories.
Construction of T/F plinth, suitable for mounting of distribution transformer. Size of the plinth will be 1.2 x 1.2 x 1.2 meter solid with brick work. 75 mm thick C.C. in ratio 1:4:8 with cement, coarse sand and brick ballast laid on the base and 75 mm thick done on all the exposed sides to the plinth.
Making L.T. Section point in LT new or existing line.
Fabrication and Erection of X-bracing on Four pole structure with fixing of bracing clamp.
Fabrication of Isolator structure with M.S. Channel, M.S. Angle, M.S. Flat etc. in required size and length including cutting, drilling holes, welding and assembling as per drawing.
Erection and grouting of Isolator structures with 1:4:8 CC 25 mm brick ballast in required size in proper alignment and making plinth of all structure in 1:2:4 CC mix with 20 mm stone grit, 15 Cm ground level to smooth finish and its proper curing including cost of cement.
Erection of 33 KV Line Isolator equipment on erected structure in proper alignment.
Erection of 33 KV Bus Isolator equipment on erected structure in proper alignment.
Loading, Carriage and unloading of Isolator from Kesco. Store to site of work or work site to store including old & damage materials.
Earthing of Isolator Structure or other MS structure with M.S. Flat by welding and connecting to existing earth mate of yard.
Fabrication of Post Insulator/L.A./C.T/P.T Structure.
Fabrication of Cable Support Structure.
Fabrication of Earthing Electrodes 3 mtr. long with 40 mm dia M.S. Round Bar making one end pointed upto 15 Cm.
Fabrication of Busbar Gantry
Fabrication of Neutral Support Structure.
Erection of Post Insulator/L.A./C.T/P.T Structure.
Erection of Cable Support Structure.
Erection of Busbar Gantry with the help Crane.
Erection of Neutral Support Structure.
Erection of 33 KV L.A.
Erection of Post/Pin Insulator with E clamp in Post Insulator Structure/Cable Support Structure.
Erection of 33 KV C.T/P.T with the help of Crane.
Erection of CT/PT junction box
Dismentalling of Top Bracket from existing single pole.
Lowering of ACSR dog Conductor of 33 KV single line for adjusting of V cross arm of single Ckt. line for converting double Ckt. line.
Fixing of V-Type cross arm on erected/existing double/try/four pole.
Fixing of M.S. Channel on erected/existing double/try/four pole.
Fixing of M.S. Angle on erected/existing double/try/four pole.
Fixing of G.I. Pin and Pin Insulator on erected/existing double/tri/four pole.
Opening the binding for taking out the conductor and dismantling the concern X-arm/bracket from pole/rail.
Dismentalling of existing Jarjar Al. Conductor from existing damaged O.H. Line
Painting of Post Insulator/L.A./C.T/P.T Structure.
Painting of Isolator Structure.
Painting of Cable Support Structure.
Painting of Busbar Gantry
Painting of Neutral Support Structure.
Erection of Battery set 24 volt 60 Ah (set of 15 cell) with charger in control room and related all work.
Loading, Carriage and Unloading of 33 KV L.A. from store to site and vice versa
Loading, Carriage and Unloading of 33 KV C.T/P.T. from store to site and vice versa
Loading, Carriage and Unloading of 33 kV single CRP from store to site and vice versa
Loading, Carriage and Unloading of 33 kV double CRP from store to site and vice versa
Loading, Carriage and Unloading of Rail Pole for bus bar gantry from store to site and vice versa
Loading, Carriage and Unloading of CT/PT junction box from store to site and vice versa
Loading, carriage and unloading of LT Metering Cubicle from store to site or vice-versa.
Loading carriage & unloading of main tank of 3/5/6 MVA, 33/11 KV power T/F alongwith radiators & its all accessories & material of following T/F from store to site of work or worksite to store in between 20 Km. distance.
Shifting of Pilfer proof metering cubical from site to meter room.
Erection of C.T./P.T. O.D. unit on erected double pole.
Mounting of 33 KV Pin Insulator
Mounting of 11 KV Pin Insulator
Mounting of LT Pin Insulator
Mounting of 11 kV B&S type Disc Insulator
Digging of Pit 2x2x1 mtr. for laying of cable through HDD Method.
Laying of 33/11 KV 3x300/400/185/70 sq.mm XLPE with HDPE Pipe through HDD Method and also marking feeder name on pipe with Paint at the interval of each 100 mtr. Along with supply of pipe
Laying of 33/11 KV 3x300/400/185/70 sq.mm XLPE without HDPE Pipe through HDD Method and also marking feeder name on pipe with Paint at the interval of each 100 mtr.
Laying of LT XLPE Cable with HDPE Pipe through HDD Method and also marking feeder name on pipe with Paint at the interval of each 100 mtr. Along with supply of pipe
Laying of LT XLPE Cable without HDPE Pipe through HDD Method and also marking feeder name on pipe with Paint at the interval of each 100 mtr.
Repairing of 33 KV Old Isolator by replacing the jaws and blades or by oiling and greasing of moving parts or by adjustment of moving mechanism or by leveling the whichever is required for smooth operation of isolator and its all related work.
Erection of L.T. Distribution circuit 500V/500 Amp. after fitting L.T. brackets and all other accessories.
Dismantling of 33 KV outdoor CT/PT with the help of Crane.
Dismantling of 33 KV CT/PT Junction Box
Erection of Lower Bus bar with ACSR Panther/DOG conductor
Erection and Grouting of 33 KV VCB Structure on Plinth
Erection of 33 KV VCB on erected structure with the help of Crane.
Erection of 33 KV single control relay panel in control room
Erection of 33 KV double control relay panel in control room
Pegging of 3 mtr. long Earth Electrodes 40 mm dia in to ground by hammering keeping its head 0.5mtr. below the ground level.
Laying of earthing strip of 50x6/40x5/25x3 mm M.S. Flat after cutting, bending, shaping and welding with earth electrodes with welding of 'U' Clamps on each electrodes and making proper joints overlapping with 40 cm each other it includes welding of riser from making earth mate to structure of both side.
Laying of 40 mm2 M.S. rod after cutting bending, shaping and welding with earth electrodes with welding of U clamps on each electrode and making proper joint overlapping 15 Cm each electrode for main earthmate.
Erection of new Upper Busbar with ACSR Dog/Panther Conductor including mounting of disc insulator string.
Making of 33KV V.C.B. plinth in size of 1.5x2.4x1.0 meter with brick work cement, sand ratio 1:6 making proper pockets for anchor bolts grouting its plastering around with smooth finish including cost of civil material.
Making all control cable connection in C.T., VCB mechanism, C.T. Junction Box, Transformer Control relay panel D.C. Battery Charger, ACDB Transformer indication board 11KV switchgear including proper termination ferruling and dressing with related work whichever is required including T/F work.
Connecting of main earthing of control room & jointing with switch gear panel by welding of M.S. flat including all materials.
Filling of soil for leveling of S/S Switch yard as per site requirement.
Final leveling of yard and removal of wastage material and soil from switch yard.
Earthing of Power T/F at three points by extending the existing M.S. Flat with main earth mat by welding.
Connecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
Fitting of 3 mtr. Long 2 No. rail pole on power T/F plinth during erection of power transformer.
Filling of drum of T/F oil in Transformer
Dismantling of Rail Poles of existing bus bar gantry
Fixing of danger board on erected poles
Dismantling of LTPB
Dismantling of HTPB
Dismantling of ACB
Dismantling of Upper Bus Bar
Dismantling of lower bus bar
Erection of TPMO
Dismantling of TPMO
Dismantling of 33 kV Isolator
Fixing of 11/33 kV Dead End fitting
Unmounting of Pin/Disc Insulator
Making of 11/33 kV Fuse Point
Digging of trench and taking out of existing control cable buried in yard.
Laying of Ist class bricks after proper ramming of soil including cost of materials.
Filling of sand above laid bricks on edge including cost of materials.
Laying, stringing, tensioning and binding of ACSR Dog conductor for H.T. O.H. line.
Loading, carriage & unloading of distribution Transformers (Upto 630 KVA) from Store to site, site to site & vise-versa.
Unloading of following power T/F main tank filled with oil, along with its all accessories like radiators, conservator tank T/F oil vent pipe etc. from Truck by crane and proper stacking.
10/8/6 MVA, 33/11/6.6 KV T/F with 2 No crane
5/3/1.5 MVA, 33/11/6.6 KV T/F
Dismentalling of following power T/F including draining of T/F oil from radiators if necessary dismentalling of all accessories, as Radiators, vent pipe conservator Tank from main Tank of T/F (Either one or all) and its proper stacking.
10/8/6 MVA, 33/11/6.6 KV T/F
5/4/3 MVA, 33/11/6.6 KV T/F
10/8/6 MVA, 33/11/6.6 KV T/F with 2 No crane
5/4/3 MVA, 33/11/6.6 KV T/Fwith 2 No crane
Shifting of T/F Tank Empty/filled by dragging or by crane of following running/damaged T/F from unloading point to plinth of T/F or from T/F plinth to shifting/loading point distance upto 25 meters and its placing in proper alignment on plinth of Transformer.
8/6 MVA, 33/11/6.6 KV T/F
5/4 MVA, 33/11/6.6 KV T/F
10/8/6 MVA, 33/11/6.6 KV T/F with 2 No crane
5/4/3 MVA, 33/11/6.6 KV T/F with 2 No crane
3/1.5 MVA, 33/11/6.6 KV T/F
Loading carriage & unloading of main tank of T/F alongwith radiators &its all accessories & material of following T/F from store to site of work or worksite to store in between 20 Km. distance.
8/6 MVA, 33/11/6.6 KV T/F
5/4 MVA, 33/11/6.6 KV T/F
10/8/6 MVA, 33/11/6.6 KV T/F with 2 No crane &trolla
5/4/3 MVA, 33/11/6.6 KV T/F with 2 No crane &trolla
3/1.5 MVA, 33/11/6.6 KV T/F
Erection of radiators, conservator tank vent pipe and all other accessories on main tank of following T/F including oil filling and all related work.
10/8/6 MVA, 33/11/6.6 KV T/F
5/4/3 MVA, 33/11/6.6 KV T/F
10/8/6 MVA, 33/11/6.6 KV T/F with 2 No crane
5/4/3 MVA, 33/11/6.6 KV T/F with 2 No crane
Dismentalling of earthing of running/damaged transformer at two points with the help of gas cutter.
Dismentalling and taking out the cable support structure by cutting with gas cutter for shifting of T/F including cutting of earthing of cable support structure wherever is required including its all related work.
Dismentalling and taking out the neutral support structure by cutting with gas cutter alongwith removing of flexible copper bond and its proper stacking.
Erection and welding of cable support structure with the help of welding including earthing of support in proper alignment and all related work.
Erection & welding of neutral support structure with the help of welding including earthing in proper alignment and all related work and fixing of flexible copper bond.
Earthing of T/F at two points by extending the existing M.S. Flat with main earthmate by welding.
Fabrication of neutral support structure with M.S. Angle and M.S. Flat.
Erection and grouting of neutral support structure with 1 : 4 : 8 CC ratio in proper alignment and plinth 15 Cm. above ground level and smooth finish.
Disconnecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
Connecting of control cable connection of marshalling box and T/F indication board and connection of Buchholz and all related connection.
Fabrication of isolator structure as per standard design.
Erection and grouting of Isolator structure in proper alignment and making plinth 15 Cm. above ground level with smooth finish.
Construction of power T/F plinth suitable for 5/10 MVA 33 KV T/F in size of 3 x 3 x 1.5 Mtr. Digging of pit in size of 3.5 x 3.5 x 1.2 Mtr. Of CC work at bottom in size of 3.5 x 3.5 x .15 Mtr. With ratio of 1:4:8 its proper ramming and curing thereafter brick work in size of 3 x 3 x 0.8 Mtr. with 1 : 6 CC Sand ratio, thereafter CC work on top in size of 3 x 3 x .25 Mtr. thereafter plastering all around the open portion, grouting of rail and M.S. Angle in top CC work and its proper curing.
T/F Flexible copper bond 30mm vide 30 Cm long & connecting with neutral support to T/F neutral bushing & proper tightening.
Supply and Erectiion of HTPB
Repairing of damage of H.T./L.T. S.T. Pole comprising following works:-
Opening the binding for taking out the conductor and dismantling the concern X-arm/bracket from pole/rail.
Taking out the damaged pole from ground by digging the pit or by cutting with gas cutter and its proper stacking.
Repairing of damaged S.T. Pole by providing M.S. Angle 50x50x6mm, 3 Nos. each of 1 meter long by clamping at 2 points and its welding including its all related work.
Erection of repaired/new S.T. Pole size 9.0 Mtr. to 13.00 Mtr. including digging of Pit back filling and ramming.
Mounting of 33 KV, 11 KV & L.T. X-arm/bracket on the pole/rail.
Dismentalling /Replacement of 33KV or 11KV pin insulator with G.I. Pin from damaged pole/ X-arm opening of binding from Insulator.
Repairing of 33 KV or 11KV damaged X-arm and proper shaping including drilling of holes whatsoever is required with the help of gas healing and welding.
Centrifusing of T/F Oil of Power Transformer.
Digging of cable trench for taking out old/damaged XLPE/PILCA, 3x50 to 3x300sqmm 33/11KV cable & taking out the above Cable from digged trench and back filling of digged trench and relaying the same cable.
Making special pole plinth of double pole of size 2 mtr. x0.5 mtr.
Khan Traders and Electrical Works
Dixit Construction Company
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .