Loading…
Loading…
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
17 Aug 2026, 10:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
57 conditions · 7 needing a document upload
The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value and Additional Performance Guarantee as per Clause 16(4)(h) of GCC-2022, in any of the following forms:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii)Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted. New Para 16(4) (h) of Part-II of GCC'22: If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below: (i) If Bid quoted in % of advertised cost is Below 0 - 5% (inclusive), Additional Performance Guarantee (%) will be 'Nil'. (ii) If Bid quoted in % of advertised cost is Below 5%, Additional Performance Guarantee (%) will be '5%.
Performance Guarantee : The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. However the clause may also applicable as amended time to time.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days.
The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value.
The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. The Security Deposit shall, however, be released only after expiry of the maintenance period and after passing the final bill based on No Claim Certificate from the contractor.
Whenever the contract is rescinded, the Security Deposit shall be forfeited and the Performance Guarantee shall be encashed. The balance work shall begot done independently without risk cost of the failed contractor. The failed contractor shall be debarred from participating in the tender for executing the balance work. If the failed contractor is a JV or a Partnership firm,then every member/partner of such a firm shall be debarred from participating in the tender for the balance work in his/her individual capacity or as a partner of any other JV/partnership firm.
In case of Bank Guarantee submitted as a Performance Guarantee then Bank confirms that it is on the SFMS (Structured Financial Messaging System) and shall invariably send the advice of this Bank Guarantee to the following bank details - IFSC CODE - SBIN000RAIL IFSC TYPE - BRANCH BANK NAME - STATE BANK OF INDIA BRANCH NAME - RAIL CITY NAME - NAVI MUMBAI ADDRESS - SECTOR-11, CBD BELAPUR, NAVI MUMBAI DISTRICT - NAVI MUMBAI STATE - MAHARASHTRA BG ENABLED - YES
"Bid Security: (1) (a) The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. The Bid Security shall be as under: Value of the Work and Bid Security : For all works, 2% of the estimated cost of the work. Note: (i) The Bid Security shall be rounded off to the nearest 100. This Bid Security shall be applicable for all modes of tendering. (ii) Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. (iii) Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above. (b) It shall be understood that the tender documents have been issued to the tenderer and the tenderer is permitted to tender in consideration of stipulation on his part, that after submitting his tender he will not resile from his offer or modify the terms and conditions thereof in a manner not acceptable to the Engineer. Should the tenderer fail to observe or comply with the said stipulation, the aforesaid amount shall be liable to be forfeited to the Railway. (c) If his tender is accepted, this Bid Security mentioned in sub para (a) above will be retained as part security for the due and faithful fulfillment of the contract in terms of Clause 16 of the Standard General Conditions of Contract. The Bid Security of other Tenderers shall, save as herein before provided, be returned to them, but the Railway shall not be responsible for any loss or depreciation that may happen thereto while in their possession, nor be liable to pay interest thereon.
The Bid Security shall be deposited either in cash through epayment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids (Le. excluding the last date of submission of bids) . iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
The Railway reserves the right of not to invite tenders for any of Railway work or works or to invite open or limited tenders and when tenders are called to accept a tender in whole or in part or reject any tender or all tenders without assigning reasons for any such action.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
@ 18% GST has been included in schedule rate, GST will be paid to the firm's at the time of billing, subjected to firm's production of sufficient documentary evidences in support of same. NOTE: % of GST as applicable during the period of execution.
Inspection charges of RITES / Third Party Inspection (TPI) Agencies are to be borne by the contractor where necessary as per extent rule (where the value of purchase order exceeds Rs. 5 lakhs)
The work shall be treated as on work contract basis and the rates tendered shall be for complete items of work (except the materials, if any, stipulated for supply by the department) inclusive of all taxes (including works contract tax,if any duties, and levies etc and all charges for items contingent to the work, such as packing, forwarding, insurance, freight and delivery at site for the materials to the supplied by the contractor, watch and ward of all materials (including those if any supplied by the department) for the work at site etc.)
Unless and otherwise mentioned in the tender documents, the following works shall be done by the contractor, and therefore their cost shall be deemed to be included in their tendered cost- i)Foundations for equipments and components where required, including foundation bolts. ii)Cutting and making good all damages caused during installation and restoring the same to their original finish. iii)Sealing of all floor openings provided by him for pipes and cables, from fire safety point of view, after laying of the same. iv)Painting at site of all exposed metal surfaces of the installation other than pre-painted items like fittings , fans, switchgear/distribution gear items, cubicle switch board etc. Damages to finished surfaces of these items while handling and erection, shall however be rectified to the satisfaction of the Engineer-in-charge. v)Testing and commissioning of complete installation
Unless and otherwise specified, power supply and water supply will be arranged by the contractor at the site for installation purpose. However, for testing purpose, electricity supply will be available free of cost to the contractor. Contractor will take due care to ensure safety of electrical installation during execution of work
The contractor shall co-ordinate with all other agencies involved in the building work is not hampered due to delay in his work. Recessed conduit and other works, which directly affect the progress of building work, should be given priority.
Tools for Handling and Erection All tools and tackles required for handling of equipments and materials at site of work as well as for their assembly and erection and also necessary test instruments shall be the responsibility of the contractor
Care of Buildings: Care shall be taken by the contractor to avoid damage to the building during execution of his part of the work. He shall be responsible for repairing all damages and restoring the same to their original finish at his cost. He shall also remove at his cost all unwanted and waste materials arising out of his work from the site.
Structural Alterations to Buildings: (i) No structural member in the building shall be damaged/altered, without prior approval from the competent authority through the Engineer-in-charge. (ii) Structural provisions like openings, cutouts, if any, provided by the department for the work, shall be used. Where these require modifications, or where fresh provisions are required to be made, such contingent works shall be carried out by the contractor at his cost. (iii) All such openings in floors provided by the Department shall be closed by the contractor after installing the cables/ conduits/ rising mains etc. as the case may be, by any suitable means as approved by the Engineer-in-charge without any extra payment. (iv) All chases required in connection with the electrical works shall be provided and filled by the contractor at his own cost to the original architectural finish of the buildings
Addition to an Installation: Any addition temporary or permanent to the existing electrical installation shall not be made without a properly worked out scheme/ design by a qualified Electrical Engineer to ensure that such addition does not lead to overloading, safety violation of the existing system.
Work in Occupied Buildings: (i) When work is executed in occupied buildings, there would be minimum of inconvenience to the occupants. The work shall be programmed in consultation with the Engineer-in-charge and the occupying department. If so required, the work may have to be done even before and after office hours. (ii) The contractor shall be responsible to abide by the regulations or restrictions set in regard to entry into, and movement within the premises. (iii) The contractor shall not tamper with any of the existing installations including their switching operations or connections thereto without specific approval from the Engineer-in-charge.
Conformity to IE Act, IE Rules, and Standards: All Electrical works shall be carried out in accordance with the provisions of Indian Electricity Act, 2003 and Indian Electricity Rules, 1956 amended up to date and As per RDSO specification
Quality of Materials: All materials and equipments supplied by the contractor shall be new. They shall be of such design, size and materials as to satisfactorily function under the rated conditions of operation and to withstand the environmental conditions at site
Inspection of Materials and Equipments: Materials and equipments to be used in the work shall be inspected by the Departmental officers. Such inspection will be of following categories: (i) Inspection of materials/ equipments to be witnessed at the manufacturer's premises in accordance with relevant BIS/ Agreement Inspection Procedure. (ii) To receive materials at site with Manufacturer's Test Certificate(s). (iii) To inspect materials at the Authorized Dealer's Godowns to ensure delivery of genuine materials at site. (iv) To receive materials after physical inspection at site. The Departmental officers will take adequate care to ensure that only tested and genuine materials of proper quality are used in work. Similarly, for fabricated equipments, the contractor will first submit dimensional detailed drawings for approval before fabrication is taken up in the factory. Suitable stage inspection at factory also will be made to ensure proper use of materials, workmanship and quality control. The tender specifications will stipulate the inspection requirements or their waiver for various materials/ equipments including norms of inspection in specific cases
Ratings of Components: All components in a wiring installation shall be of appropriate ratings of voltage, current, and frequency, as required at the respective sections of the electrical installation in which they are used. All conductors, switches and accessories shall be of such size as to be capable of carrying the maximum current, which will normally flow through them, without their respective ratings being exceeded
Conformity to Standards: All components shall conform to relevant Indian Standard Specifications, wherever existing. Materials with ISI certification mark shall be preferred. A broad list of relevant Indian Standards is given in Appendix D. These Indian Standards, including amendments or revisions thereof upto the date of tender acceptance, shall be applicable in the respective contracts
Only quality materials of reputed make as specified in the tender will be used in work.
Testing: All tests, to be done before, during and after installation, shall be carried out, and the test results shall be submitted to the Engineer-in-charge in prescribed Performa, forming part of the Completion Certificate
Commissioning on Completion: After the work is completed, it shall be ensured that the installation is tested and commissioned
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request. (d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
Please read the Explanatory note for detail description of work, their make etc and all other attached documents before submission of Tender.
Any other reputed make/ brand other than as mentioned in the explanatory note may be included during the execution of the works on an urgent basis/as per direction when needed with approval of competent authority.
Electrical work for Provision of DC Track Circuit for dual detection in various station yards of Kharagpur division.
Elect-Chg-26-27-DD-13
Elect-Chg-26-27-DD-13
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹19,400
17 Aug 2026
16 Jul 2026
3 Aug 2026
83 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,71,268.76 | ||
| — | 14.00 | — | — | ||
| Supply of 20W or higher wattage LED tube light with Batten ( integrated electronic driver).As per CEGE approved Specification for LED tube light-high power, 2100 Lumen output,220V, 50Hz AC with constant current driver with short circuit and overload protection etc. | — | — | — | 4,733.96 | |
| — | 4.00 | — | — | ||
| Supply of Inverter Based Back-up Emergency Batten with 22 W LED tube light LED Rating (in Watts. Inverter light should be as per RDSO guidelines.(Letter No: RDSO-EEMoLKO(GUID) /1/2020 DT 27-01-2026. | — | — | — | 7,457.64 | |
| — | 18.00 | — | — | ||
| Fixing and Commisioning of 20W or higher wattage LED tube light with Batten | — | — | — | 862.2 | |
| — | 4.00 | — | — | ||
| Supply of street light LED 45 watt or higher wattage street light as per Specification No. CEE/S/185/ LED/12/21/Rev-0, 2021 dated 22/12/2021 suitable for fixing in 42.4mm arm, including system lumen efficiency 110 lm/Watt (±5%), Power factor 0.90 at full load, normal voltage of luminary: 230V AC ±5%, 50HZ, Operating Voltage range: 140-270V AC, working temperature should be -10°C to 55°C, The complete unit cubicle together with its mounting arrangement shall be subjected to shock testing as per latest IEC 61373, LED life expectancy 50000 burning hrs., Colour temperature range 5500-6500K, Colour Rendering Index (CRI) 70 with driver featuring (Constant current driver with open & short circuit protection), THD<10%, efficiency 85%, SPD for External surge protection-of minimum 10KV to be separately installed with the each fixture (As per ANSI C 136'2- 2014), Lamp shall be Distortion free, clear, heat resistance toughened glass of thickness 4.00 mm, polycarbonate lens Fire retardant FR grade, Ingress Protection of IP-66 or better, The housing shall be single housing, side entry high pressure aluminium die cast/extruded aluminium, grey colour corrosion-resistant polyester powder coated with separate optical and control gear compartments, high conductivity (LM/6/ADC12/LM24) with integral heat sink and heat proof silicon rubber, silicon gasket between housing & cover, Impact Resistance of IK-07 or better. Cover to be fixed to the housing by mean of stainless steel screws and stainless steel fastener. 1) Unit shall with stand 300 volt AC for 1 minutes and cut off. It will automatically ON when voltage comes in oparating voltage range. Warranty for free replacement for 05 years. 2) Shall be oparated with reverse polarity for 3 minutes at maximum value of voltage range between supply terminal and body off the unit. 3) Shall be tested at 1500 volt AC for 1 minutes between supply terminals and body of the unit. | — | — | — | 7,960.24 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of LED 45 watt or higher wattage street light including wiring of light from loop box with proper termination by Pin Type Terminal End Lugs including fixing to the arm by mean of stainless steel screws and stainless steel fastener as per site requirenment, to complete the job. | — | — | — | 779.4 | |
| — | 4.00 | — | — | ||
| Supply of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, Minimum Air delivery-210 Cubic Meter/Min, total harmonic distortion- 8% [max], Rated Voltage: 230 V,50HZ Single phase AC, Blade thickness (Min): 1.1mm, Blade material : Aluminium, Bearing: Double ball bearings, Down rod size (without shackle) : 300mm, Shank & Shackle thickness(Min) : 2mm, canopy : 2 nos., colour standard: white, BEE rating : 5 star (as per Ministryof Power Notification Number: S.O. 2210 (E) and S.O. 2211 (E) dated. 12th May 2022 or latest), Rated power-28 watt [max], Warranty [Min] 30 Months. Conforming to- (i)IS:374/2019 with Amendment No. 1/2022 or latest (ii)IS:302 (Part 2/Sec 80) - For safetyrequirement (iii)IS:14700 (Part 3/Sec2) for THD. Speed control with electronic regulator (step type with minimum 5 running positions) and Regulators shall be provided with radioand television interference suppressing devices as per clause 10.7 of Amendment No. 1/2022 to IS 374/2019 or latest. Make: IS approved. | — | — | — | 11,694.92 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of Brushless DC (BLDC) Motor Ceiling Fan, ISI marked, Sweep size: 1400 mm, suitable for 230V, 50Hz, AC supply confirming to Class:I of IS: 374/latest. Fixing of the fan shall be done with suitable clamp, hook, nut/bolts etc. and connection with flexible twin twisted multistrand Copper wire and removing of the existing old fan (if any) and handing over of the same to Railway Store with clear acknowledgement, as per site requirement. | — | — | — | 464.88 | |
| — | 4.00 | — | — | ||
| Supply of Wall Mounted Fan with Brushless DC (BLDC) Motor, sweep size 400 mm with feature of Oscillaton & Vertcal Adjustable Tilt Mechanismn Minimum Air Delivery 65 cubic meter/min, Rated Voltage: 230 V, 50Hz, Single phase AC, Motor Winding Material: Copper, No. ofBlades-3, Provided with Pull cord or string based speed control mechanism with minimum 3 speed stepsn Colour: White, Minimum Service Value 1.43 as per BEE 5 star rating (BEE's Schedule- 32, Table & Wall-Mounted Fan), Conforming to IS 555:1979 (Reaffirmed Year: 2020) with all amendments. | — | — | — | 18,440.68 | |
| — | 4.00 | — | — | ||
| Fixing and Commissioning of Wall Mounted Fan WITH 5 STAR and above RATING 400 mm size , suitable for 230V, 50Hz, AC supply as per site requirement. | — | — | — | 514.88 | |
| — | 4.00 | — | — | ||
| "Supply of Heavy duty Exhaust Fans 300 mm , 1400 RPM suitable for 230V, 50Hz, AC supply, Conformity to Indian Standrad IS: 2312 (latest).accessories such as Frame, Legs Set,Rubber Clamps & Other Hardware - inclusive in the scope of supply. | — | — | — | 10,169.48 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of Heavy Duty Exhaust Fans as per consignee requirement. | — | — | — | 518.2 | |
| — | 4.00 | — | — | ||
| "Supply of TPN 4-way DB (Double Door) consisting with FP 63A, 10kA MCB with 4PP, Type B- 01 No. as incoming and DP 32A, 10kA MCB with 2PP, Type B- 03 Nos., DP 20A, 10kA MCB with 2PP, Type B- 03 Nos. as outgoing with .bus-bar, Neutral links, Spreader Link and Earth bar etc. as applicable. Thickness of DB material (in mm): 1.6 mm (CRCA Sheet Steel). Cost includes all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached. | — | — | — | 38,227.12 | |
| — | 4.00 | — | — | ||
| Fixing and Commisioning of TPN 4-way DB (Double Door) consisting with FP 63A, 10kA MCB with 4PP, Type B- 01 No. as incoming and DP 32A, 10kA MCB with 2PP, Type B- 03 Nos., DP 20A, 10kA MCB with 2PP, Type B- 03 Nos. as outgoing with bus-bar, Neutral links, Spreader Link and Earth bar etc. and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached with complete wiring to complete job. | — | — | — | 1,950.16 | |
| — | 60.00 | — | — | ||
| Concealed Wiring of light and fan point by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, FR-LSH, PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked,through PVC Conduit Pipe of Nominal Size 20mm/25mm(as per site requirement) and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark. including supply of all required materials like lamp holder,Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable moduler stainless steel JB box with moduler PVC cover , stainless steel switch Board with moduler PVC cover,PVC Spacers, PVC Saddles,PVC Bends, PVC Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board . The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.Covers or cover parts or parts of them, which are intended to ensure protection against electric shock, shall be held in place at two or more points by effective fixings..The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 44,743.2 | |
| — | 180.00 | — | — | ||
| "Concealed Sub circuit wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694- 2010(reaffirmed 2020), ISI marked. with 2.5Sq mm earthing wire of Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark with Supply & fixing of PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee." "Concealed Sub circuit wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. with 2.5Sq mm earthing wire of Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR- LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked. through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark with Supply & fixing of PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee. including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable as earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee." | — | — | — | 27,291.6 | |
| — | 60.00 | — | — | ||
| Concealed Sub circuit wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked with 4 Sq mm earthing wire of Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete the job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutal and 1mtr of 4 Sq.mm PVC Cu. cable as earthing. | — | — | — | 11,222.4 | |
| — | 8.00 | — | — | ||
| "Supply of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10-16A, 10kA, Type B- 01 No. with Stainless Steel 12M Box and all other accessories to complete job for concealed wiring. Specs: Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark and Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark. with modular SP MCB 10A, 10kA, Type B- 01 No. ISI marked, rated voltage: 240V AC, conforming to IS/IEC 60898-1:2015 (Reaffirmed Year:2024) or latest, with rated short circuit current capacity 10KA, fixed unadjustable time current characteristics suitable for use in protection of industrial, commercial and domestic electrical installations. along with 12M stainless steel Box, moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 11,519.92 | |
| — | 8.00 | — | — | ||
| Fixing and commissioning of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10-16A, 10kA, Type B- 01 No. with Stainless Steel 12M Box, moduler cover plate duly Concealed in wall surface including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Schedule item No. as per site requirement). | — | — | — | 235.84 | |
| — | 8.00 | — | — | ||
| "Supply of modular electrical switches and accessories with 6A/16 A, 6 Pin Socket, with Stainless Steel boxes and all other accessories to complete job for concealed wiring. Specs: Modular Electrical Switch, 16 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark, Modular type Socket outlet, 6 pin, 6A & 16A, 230V, 2 Module, Shuttered (Operation of Shutter should be independent of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark, with moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 8,922 | |
| — | 8.00 | — | — | ||
| Fixing and commissioning of modular electrical switches and accessories with 6A/16 A, 6 Pin Socket, with Stainless Steel boxes, moduler cover plate duly Concealed in wall surface including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Schedule item No. as per site requirement). | — | — | — | 235.84 | |
| — | 4.00 | — | — | ||
| Supply of Cable loop Box(Of fiber body) for 3 phase incoming & outgoing connection consists of 3 phase &neutral terminal &15 A K-fuse as per relevant ISS, with suitable bridge arrangement of size 240mm x 140 mmx 100mm, fitting shall be made with necessary arrangement as per site requirement, cables are to be terminated withproper socking arrangement to complete job. | — | — | — | 3,223.68 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of POLYCARBONATE make fire retardent Cable loop box ( of fibre body), IP 66 Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job. | — | — | — | 322.36 | |
| — | 8.00 | — | — | ||
| "Supply of Earthing arrangement with supply of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes supply of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. Make: Any IS standard Indian make." | — | — | — | 29,401.04 | |
| — | 8.00 | — | — | ||
| Erection of Earthing arrangement with erection of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metalic cover etc. as per site supervisor's instruction. Cost includes erection of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrod pipe to light pole /Rail pole etc. | — | — | — | 7,052.24 | |
| — | 250.00 | — | — | ||
| "Supply of 4 x 35 sq. mm, XLPE Insulated, 1100 Volts Grade, LT Cable with improved fire performance category C2-FRLS, Stranded Aluminum Conductor complying with Class 2 of IS 8130, Cores Laid up, Inner sheath of PVC applied by extrusion, Galvanised round steel wire or Galvanized steel formed wire (strip) Armoured, Cores' identification by Coloured strip applied on the cores or by Colouring of XLPE Insulation, Outer Sheath of PVC Compound applied by extrusion conforming to the requirement of type ST2 as per IS 5831 & also meet the requirement of C2 Category tests under clause 15.1.1 & 15.2.1, Conforming To IS: 7098 Part-1 with amendment no. 1,2,3,4,5 or latest & ISI Marked. (i) Type Test Certificate Conforming to IS:7098 Part-1 from NABL Accredited lab has to be submitted along with the offer and along with the supply of material for similar type of cable having conductor cross-sectional area not less than the mentioned size in description. (ii) Routine test Certificate has to be Submitted along with Supply of materials. (iii) Acceptance test as per IS:7098 Part-1 has to be conducted by Inspection Agency. | — | — | — | 1,10,170 | |
| — | 200.00 | — | — | ||
| Laying of cable/ cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. | — | — | — | 21,812 | |
| — | 50.00 | — | — | ||
| Laying of cable/ cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 12,482.5 | |
| — | 50.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing. Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 3,750 | |
| — | 4.00 | — | — | ||
| Supply of 1.5 TON INVERTER SPLIT AC, 5 STAR WITH ECO FRIENDLY REFRIGERANT , TYPE:-HIGH WALL SPLIT AC, MAKE - LLOYD, BLUE STAR, VOLTAS, DAIKIN, HITACHI, O GENERAL OR EQUIVALENT , Details specification-BEE StarRating - 5, Type of Air conditioner - High wall split AC, Technology of AC - Inverter (Variable Speed), Nominal cooling capacity in Ton/(kcal/hr)- 1.5 Ton/4500 kcal/hr, Coil Material- Copper, Eco-friendly refrigerant, Minimum length of copper pipe and suitable connecting electrical cable for Installation and commissioning 5 meter, warranty on Machine 1 year, Warranty on Compressor- 10 Or higher including supply . | — | — | — | 1,45,762.8 | |
| — | 4.00 | — | — | ||
| Installation And Commissioning of 1.5-2 Ton Split AC (including supply of additional Copper pipe as per IS 10773 : 1995 with latest amendment or specification issued from HQ/GRC if any time to time, connecting copper cable, PVC drain pipe, refrigerent, outdoor mounting stand , nut- bolt , Refrigerant Copper pipe of all size and all other accessories as per site and consignee requirement as per latest IS specification) no extra cost will be paid by Railway. | — | — | — | 3,728.8 | |
| — | 4.00 | — | — | ||
| "Supply of starter for split AC for 1.5ton or 2ton of 20-25A capacity or as per site requirement as per IEC 60947-4-1 or with latest amendment / any other specification if any. | — | — | — | 1,762.72 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of starter for split AC for 1.5ton or 2ton of 20-25A capacity or as per site requirement. with all others accessories and proper wiring to complete job. | — | — | — | 176.28 | |
| — | 20.00 | — | — | ||
| Supply,fixing and commissioning of High grade superior quality Refrigerant Copper pipe with insulation of size 1/4 inch, as per IS 10773 : 1995 or latest or specification issued from HQ/GRC if any time to time, thickness 0.030 inch. | — | — | — | 1,961.6 | |
| — | 20.00 | — | — | ||
| "Supply of High grade superior quality Refrigerant Copper pipe with insulation of size 5/8 inch.as per IS 10773 : 1995 or latest or specification issued from HQ/GRC if any time to time, thickness 0.030 inch or as per site requirement.. | — | — | — | 6,880 | |
| — | 20.00 | — | — | ||
| Supply,fixing and commissioning of PVC/UPVC pipe to be used for Air condition, Inner Diameter (ID)(mm) 32 or as per site requirement. Pipe As per Is 4985 | — | — | — | 1,949.2 | |
| — | 20.00 | — | — | ||
| Supply,fixing and commissioning of uPVC Trunking (Length 2 Meters) of Size (mm): 170MM X 57MM or as per site requirement Natural/White Casing and Capping Trunking (with cover) For AC's copper pipe Installation including coupler,cover,angle,cap,flat teeetc and other items to complete the job . Pipe As per Is 4985 | — | — | — | 26,186.4 | |
| — | 10.00 | — | — | ||
| Supply of PVC Adhesive Ac Pipe Wrapping Tape 25mm 25mtr length | — | — | — | 3,644.1 | |
| — | 20.00 | — | — | ||
| Supply,fixing and commissioning of PVC , Aircondition drain pipe, Inner Diameter (ID) (mm) 25 or as per site requirement. | — | — | — | 339 | |
| — | 2.00 | — | — | ||
| Supply of LT Panel consisting of Incoming: 1X 4 pole MCCB, 320A, 36 kA and Outgoing: i) 1 X 160A, 4 pole MCCB, 25kA, ii) 3 X 100A 4-pole MCCB, 25kA iii) 2 X 63A, 4 pole MCCB, 25kA iv) 4 way Cu. Bus-Bar 600A, Indicator Lamp, digital multifunction meter with all accessories. MCCB Make: L&T, C&S, Legrand, Schneider, Havells Is approved conforms to IS/IEC 60947-2 or latest and all other specifications as per Annexure A of HQ Description o.SER/ELEC/GS/DESCRIPTION / LT PANEL/1/REV-0/MAR 2024. | — | — | — | 2,23,390.32 | |
| — | 2.00 | — | — | ||
| "Erection, Installation of LT Panel consisting of Incoming: 1X 4 pole MCCB, 320A, 36 kA and Outgoing: i) 1 X 160A, 4 poleMCCB, 25kA, ii) 3 X 100A 4-pole MCCB, 25kA iii) 2 X 63A, 4 pole MCCB, 25kA iv) 4 way Cu. Bus-Bar 600A, Indicator Lamp, digital multifunction meter with all accessories. MCCB Make: L&T, C&S, Legrand, Schneider, Havells conforms to IS/IEC 60947-2 or latest and all other specifications as per Annexure A of HQ Description No.SER/ELEC/GS/DESCRIPTION / LT PANEL/1/REV-0/MAR 2024. | — | — | — | 11,169.52 | |
| — | — | — | 1,48,159.64 | ||
| — | @ 18% | on the sub-total of | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LEDSpecificationScan_compressed.pdf
ATTACHMENT
cablespec.pdf
ATTACHMENT
GeneralConditions.pdf
ATTACHMENT
GCC 2022
ATTACHMENT
MANDATEFORM.pdf
ATTACHMENT
CerInfregEmp.Par.ofRet.RailwayEmployees.pdf RAILWAY EMPLOYMENT CERTIFICATE
ATTACHMENT
JPOfordiggnigwork.pdf
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf GCC correction slip
ATTACHMENT
ExplanatoryNoteforDCTrackCircuit.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
CerInfregEmp.Par.ofRet.RailwayEmployees.pdf
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .