Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.1 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹36.9 L+₹3.0 L (8.71%)Rejected-Finance HOUSE NO 03 RAGHAVPURAM MALL ROAD MORAR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹42.9 L+₹8.9 L (26.3%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | 4₹43.1 L+₹9.2 L (27.0%)Rejected-Finance | 4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | 5₹43.1 L+₹9.2 L (27.1%)Rejected-Finance | 5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIR/MAINT OF E/M INSTALLATION, PCATT AND CERTAIN BLDGS IN TECH AREA AT AF STN GWALIOR
2023_MES_590761_4
8900/1469/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
Gwalior
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹90,000
Yes
27 Jun 2024
28 Feb 2024
25 Mar 2024
28 Feb 2024
22 Mar 2024
8 Mar 2024
Amount
Demolition of cement concrete ( unreinforced) including floor tile ground floors and pavings n. exc 15 cm thick below or above G.L complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 Type D2 ( using 40mm graded Stone aggregate) as in subbase, floor and pavings hardstanding complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floors , hard standing kerbs, haunching, rounded or chamfered on edges, coping , floor finishes etc incl necessary form work.
M&L for 25 mm thick PCC (1:2:4) type B-0 (12.5 mm graded stone agg) as in sub base of flooring complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C2, using 20 mm graded stone aggregate as in Plinth protection and finishing the surface even & smooth with using extra cement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for non skid coloured ceramic tiles 7-8mm thick (Square/Rectangular), area of each tiles exc 0.06 Sqm but not exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. complete all as specified and directed.
M&L for glazed ceramic Coloured tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 complete all as specified and directed.
M&L for 300x300x10 mm thick footpath designer tiles any colour and shape with grey cement and pigment set, jointed and pointed on neat cement slurry as in floors including 15 mm thick screed bed with bedding layer in CM (1:6) complete all as specified and directed.
M&L for 8 to 10mm thick double charged vitrified ceramic coloured tiles (square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per above here-in-before but as in skirting/dado but 10mm thick cement plaster1:4 as backing coat complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, & Frame, ladders, framed balusters, walk ways, railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
S&F MS tubular pipes as in vertical post , rafter & purlins as in sheds/canopy cut to reqd shape, welding drilling and including bending as necessary, gusset plates, riveting, etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed. Make: ISI Marked as approved by GE.
M&L for preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and directed.
M&L for Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including Dismantling of existing Plain or corrugated steel sheeting, any gauge, thickness complete all as specified and directed.
M&L for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Ridge, valley/ gutter fixed with self tapping screws including Dismantling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
Demolition of wall and ceiling boards (fibre ,pulp, insulation etc ) or insulation boards /slabs/ blankets any thickness including wall panelling cover fillets or aluminium grid frame work complete all as specified and directed
S&F 12mm thick perforated Gypsum Board as in wall panelling fixed with screw and sealed the joints with necessary tape and putty including Gl frame work for seamless wall panelling comprising of Gl channel frame work 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm with and including having kurled web of 50 mm and flange of 26 mm each with lips of 10.50 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
S&F 4mm thick HPSC pre-prime non asbestos fibre cement building board (E-classic) decorative finish including E-grid suspended false ceiling grid system 600x600mm with main runner 33x24x0.6mm, cross tee 25x24x0.6mm and wall angle 19x22x0.4mm ceiling suspended with 4mm dia GI wire hanger fixed with steel dash fasteners to RCC Roof or from purlin with butterfly clips hold down clips etc from soffit at approx 1.20mtr centre to centre including dismantling old unserviceable false ceiling with grid any description complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) of any description n.exc 1.5 Sqm each complete all as specified & directed
Taking down chowkats with shutters (without taking off shutters from the frames) of any description exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified & directed
Taking down shutters of any description exc 1 Sqm and n exc 2 sqm each complete and refixing in its position incl necessary Resecuring & easing all as specified & directed.
S&F 30mm thick flush shuttter, solid core construction, with block board core and plywood face panels, commercial type on both side complete all as specified and directed.
M&L for preparing of new wood surface of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), With Wood free EPS with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
S&F 100mm butt hinges medium weight stainless steel (ISI Marked)and fixed complete all as specified and directed.
S&F 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed .
S&F 150mm long aluminium barrel tower bolts, of extruded section complete all as specified and directed .
S&F 250 mm long 16mm dia aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, fabricated type complete all as specified & directed
S&F in repairs 3mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors including preparation of floor by cleaning of old adhesive and filling the cracks/depressions with POP/white cement complete all as specified and directed.
S&F Powder coated aluminium frame for door, window, ventilators and partitions with extruded built up standard tubular sections with necessary jointing aluminium cleats using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium door shutters with extruded built up standard tubular sections using aluminium sec not less than 2.00 mm thick, (shutter with styles 85mmX44.45mm, top rails 83.5mm X 44.45mm , intermediate rail 83.5mmx44.45mm, bottom rail 114.3mmx44.5mm) jointed with jointing cleats, nut bolts and screws including rubber neoprene gasket and aluminium beading for fixing glass & ACP Sheet complete, all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium sliding windows shutters with extruded built up standard tubular sections (using aluminium sec not less than 1.5mm thick), fixing to frame includig rubber neoprene gasket and aluminium U channel, 02 Nos sliding rollers at bottom, locking arrangement to each shutter using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge.
S&F 5mm thick tinted glass, and glazing in square/rectangular aluminium shutters/frames complete all as specified and directed.
S&F 4mm thick tinted glass, and glazing in square/rectangular aluminium shutters/frames complete all as specified and directed.
S&F 4mm thick ACP (Aluminium composite pannel) coloured sheet with 0.25 mm thick of aluminium coil, sandwitch pannel as in aluminium doors/wall claddings with sealent and necessary hidden screws complete all as specified and directed
S&F in repairs 4mm thick ACP (Aluminium composite pannel) coloured sheet with 0.25 mm thick of aluminium coil, sandwitch pannel as in aluminium doors/wall claddings with sealant and necessary hidden screws complete all as specified and directed.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with glazing putty or galvanized wire staples including to wooden/steel window/vents with beading etc complete all as directed.
S&F in repair 10 litre capacity PVC valve less symphonic action type flushing cistern low level , white, with inlet, ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) all as specified and directed.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), P- Type/ S-Type any colour (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed.
S&F in repairs PVC Seat cover for water closet pan (pedestal pattern), matching colour including fixing bolts. Make: Hinware, parryware & Cera etc
S&F in repair Vitreous China urinals half stall flat back white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm Brass CP waste coupling with PVC waste pipe & Grating complete all as specfied and directed.
S & F in repair vitreous china wash basin, white, flat back size 550 X 450mm including 32mm Brass CP waste Coupling, PVC Waste pipe and Grating complete all as specified and directed.
S&F 15mm bore medium grade galvanized iron tubing with all fittings e.g. socket, union, nipple etc. including cutting of pipe in required size , making threads etc. including taking down old unserviceable pipe, complete all as specified and directed
S&F 20mm bore medium grade galvanized iron tubing with all fittings e.g. socket, union, nipple etc. including cutting of pipe in required size , making threads etc. including taking down old unserviceable pipe, complete all as specified and directed
S&F in repairs 20mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
M&L for Cutting chases for concealed water tubing or concealed conduit wiring, etc. making good to facings where required and pointing in cement mortar 1:3 not exc 10 cm girth complete all as specified and directed.
S&F in repair for 110 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specified and directed.
S&F in repair for 75 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specified and directed.
S&F in repair 110mm PVC(SWR) bends complete all as specified and directed.
S&F in repair 110mm PVC(SWR) junction single, (Single T) equal or unequal complete all specified and directed.
S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair chromium plated fency type bib taps long body cast copper alloy with capston head handle screwed down screwed for iron pipe or for brass ferrule & fixed in 15 mm bore pipe complete all as specified and directed.
S&F in repair 15mm bore pillar taps, fancy type, chromium plated screwed down high pressure with or without lettered with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs Brass CP, fancy type 15mm bore Angle Cock with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs Brass CP, fancy type 15mm bore Concealed stop cock with crutch or butterfly handle, screwed both ends for iron pipecomplete all as specified and directed.
S&F in repair for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repairs Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) and Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and directed.
S&F in repairs 3mm thick sheet glass, ordinary quality and glazing with oil putty in squre n exc 0.50 Sqm in each pane at any height complete
Demolition of stone slabs and interlocking tiles of any description or thickness in floors, aprons etc laid in any type of mortor complete all as specified and directed.
M&L for 15-18 mm thick Granite (of any type) work (table rubbed and polished) in floors, steps pillar, platform or oval shape wash hand basin including cutting to fit the WHB, partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 60mm thick machine pressed precast coloured concrete interlocking paver block, Glossy finish any shape and size and colour confirming to IS 15658-2006, M-35 Grade with grey cement and pigment and complete all as specified and directed. Make: ISI Marked as Approved by GE.
All as per item No 66 above but 80mm M-40 Grade thick paver blocks complete all as specified and directed
M&L for sand/stone dust filling under floor watering and levelling to receive pavor blocks complete all as specified and directed.
Supply and fix in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed(minimum weight 25mm-455gms) suitable for 20mm dia pipe complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) incl demolition of brick work of any description and in any position built in cement mortar including disposal of rubbish complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick in CM 1:4 incl finished even and smooth without using extra cement finished complete all as specified and directed.
M&L for 15mm thick rendering other than fare face of brick/concrete surfaces in CM 1:6 finished including taking down old cement plaster on brick surface incl raking out joints hacking for key, scrubbing down with water etc and prepared to the plaster complete all as specified and directed.
M&L for Preparation of newly plaster surface of wall and applying two coat of oil bound distemper over a coat putty & primer white or tinted as approved all as specified and directed.
M&L for Preparation of newly plaster surface of wall and applying two coat of exterior emulsion paint (weather coat) over a coat of primer white or tinted as approved all as specified and directed.
Dismantling of old PVC water tanks with float valve and S&F 500 litre capacity rotational moulded ploythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gm s) complete all as specified and directed.
Dismantling of old PVC water tanks with float valve and S&F 1000 liret capacity rotational moulded ploythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gm s) complete all as specified and directed.
Demolition of cement concrete in roofs, chajjas and similar suspended work including existing roof treatment (screed plaster & tarfelt of any description) n.exc 0.15mm thick and removing the demolished material out of MoD land complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in levelling course, benching, kerbs and levelling course etc over roof surface complete all as specified and as directed
Supply only liquid water proofing compound complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid separately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane on prepared surface. (c) Applying hot blown grade bitumen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber and sealed using butane torch by torch application with 10cm side laps and 15cm end lap by authorized applicators. (e) Applying a coat of Aluminium Paint over APP Membrane. Make- IWL India Ltd, Torchtar, STP
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or PCC 1:2:4 complete all as specified and directed.
Disconnecting/Dismantling existing PVC water tanks, setting aside (or lowering if required) and reconnecting and re-fixing in position including Cleaning repairing, etc) any size with plumbing work complete all as specified and directed.
M&L for repairing of damaged RCC Chajja, fascia, fins, roof projection, ceiling and balcony railing etc at any height by rendering 15 to 25mm thick in one or two layers as per site requirement in CM 1:3 incl hacking out old broken/damaged concrete portion, cleaning of old reinforcement etc and applying neat cement slurry @ 3 Kg/Sqm complete all as specified and directed. (Note : Rate for all scaffolding required for repairing work shall be deemed included in this rate)
S&F 1.40mm dia GI netting (20 mm mesh size) over/around exposed reinforcement of chajja, facia, ceiling & wall etc and securing with screws , washers/ nails complete all as specified and directed by Eng-in charge.
Demolition of reinforced cement concrete ( reinforced) of any description and in any position not otherwise specifically provided and dispose off the demolished material out of defence land complete all as specified and directed.
M&L for RCC nominal mix 1:2:4 type B-1 (using 20 mm crushed stone aggt) as in shelves, slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Formwork to soffits of suspended shelves, slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for 10mm thick rendering fare face of concrete surface as in ceiling in CM 1:4 finished even and smooth without using extra cement finished complete all as specified and directed.
M&L for preparation of newly plastered ceiling surface and applying two coats of white wash all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Along the internal/ external wall and floor junctions below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes with coloured CM 1:2 to match with the existing floor complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM 1:2 to match the existing floors complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and plugging holes with CM 1:2 to match the existing surface complete all as specified and directed.
M&L for Preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash complete all as specified and directed.
All as per item No 94 above but on ceiling surfaces.
M&L for Preparation of old decorated surface of wall include brooming down with steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling the cracks and depressions and applying one coat of distemper oil emulsion with roller white or tinted as approved complete all as specified and directed.
M&L for prepration of old decorated external surfaces of wall applying one coats weather coat exterior emulsion with roller, as approved including filling the cracks and depressions with putty/ POP to make the surface even and smooth matching to the adjacent wall surfaces complete all as specified and directed.
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans and air circulating fans etc , of any description, any sweep and from any position / locations (i.e.Technical Area's OTM Accn / hangers),sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in position after , dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades,connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’
M&L rewinding of same with super enamelled copper wire of suitable existing size/gauge including insulating material and varnishing including testing to the satisfaction and all as directed by Engineer-in-Charge for the following type of fans :- (a) Ceiling fan 1200 / 1400 mm sweep any make.
(b) Exhaust fan 300 mm / 225 mm sweep any make.
(c) Exhaust fan 375 / 450 mm sweep any make.
(d) Wall/Cabin fan 450 mm sweep any make.
(e) Pedestal fan 400 mm sweep any make.
(f) Air circulating fan of 610 mm sweep any make.
(g) Flame proof Exhaust fan 300/400 mm sweep any make.
Supply only the following spare for replacement in fan complete all as specified and directed. (a) Bush for the ceiling fan of any make and sweep.
(b) Ball bearing for ceiling fan/wall fan/pedestal fan/exhaust fan & Cabin fan make : NBC/SKF
(c) Rubber reel.
(d) Split pin
(e) Condenser 2.5 MFD Make : Siemens/EPCOS/Usha
(f) -do- but 3.15 MFD
(g) -do- but 4 MFD
(h) Canopy for ceiling fan (set of 02) as per sample. Make : Khaitan/Crompton/Bajaj/Usha
(m) Regulator resistor type suitable for wall fan Make : Khaitan/Crompton/Usha.
(n) -do- but for pedestal fan
(o) MS clips (set of two) as per sample of ceiling fan
M&L for servicing of in position /of taking down i.e.required ceiling fan/exhaust fan/cabin fan (any make any size) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber real complete and re-fixing in the same position after repair to the entire satisfaction and as directed by Engineer -in- Charge.
M&L for painting of ceiling fan including fan blade of any make of any size with one coat of synthetic enamelled paint after scraping old paint and preparing surface for painting including one coat of red oxide primer and rewriting existing MES number with black paint complete to the entire satisfaction and as directed by Engineer -in- Charge.
-Ditto- all as per item No 102 above but exhaust fan/Air circulator fan.
Supply and fixing down rod for ceiling fan made of GI pipe 15mm dia medium grade of length 0.3 to 01 meter or as required including threading, cutting slotting drilling including nut, bolt clip washer and rubber real.
S&F wall /pedestal fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
S&F Exhaust fan blade of any sweep/any size as per sample all as directed by Engineer-in-charge.
S&F Exhaust fan clamp (leg) as per sample (set of 3/4) including rubber packing and clamp for bolt all as directed by Engineer-in-Charge.
Taking down UNSV Geysers of any size and make from wall by disconnecting and sealing water line and electrical connection for annual painting/ maintenance/servicing/overhauling/ dismantling of various parts for repair/replacement/painting including carryout brazing to inner tank etc, re-assembling after repair and replacement of worn parts
S & F GM non-return valve, 15 mm bore. ISI mark all as directed by Engineer-in-Charg.
S & F lead cum brass alloy pipe for inlet & outlet connection 15 mm bore 450 long including check/end nuts and washer to prevent water leakage all as specified and directed.
S & F PVC pipe steel thread armoured for inlet and outlet connection, 15 mm bore 450 long all as specified and directed.
S & F vent pipe connection of 15 mm bore, light grade, GI Pipe of required length including necessary fittings complete all as specified and directed.
S & F heating element of any type, ISI marked (2.0 KW) for 50 ltrs capacity geyser all as specified and directed.
S & F heating element of any type, ISI marked (1.5 KW) for 25 Ltrs capacity Geyser all as specified and directed.
S & F thermostat for 50/35/25 ltrs capacity Geyser of any type and make as per sample ISI marked all as specified and directed.
S & F pressure release valve 15 mm dia suitable for 50/35/25 ltrs Geysers of any make. ISI marked all as specified and directed.
S & F syphone assembly complete with packing ring and nuts and bolts suitable for 50 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
S & F syphone assembly complete with packing ring and nuts and bolts suitable for 25 ltrs capacity of Geysers of any make including testing against leakage all as specified and directed.
S & F PVC insulated copper conductor cable multi stranded 3 core 4 Sqmm flexible all as specified and directed.
S & F fusible plug made of brass having lead alloy fuse suitable for 50/35/25 ltrs capacity Geyser of any make all as specified and directed.
S & F Inner copper tank for having 50 ltrs capacity Geyser of any make all as specified and directed.
S & F Inner copper tank for having 25 ltrs capacity Geyser of any make all as specified and directed.
S & F outer tank for having 50 ltrs capacity Geyser of any make all as specified and directed.
S & F outer tank for having 25 ltrs capacity Geyser of any make all as specified and directed.
S&F in replacement 8 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary concrete work complete all as specified and directed.
Supply & fixing in repair Integral LED Post Top Lantern 20 watt LED and accessories fixing to electric source complete and fixing GI pipe of suitable length grouting in PCC complete all as specified and directed at sit
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per item No 127 here-in-before but cable of size 6 Sqmm FRLS with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. (Note : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.)
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.)
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.)
Supply, fixing, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 63 Amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) 125 Amp complete with one TPN 125 Amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) complete with one TPN 40/63 Amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.
All as per item 138 here-in-before but distribution board single pole and neutral, 12 way .
All as per item 138 here-in-before but distribution board single pole and neutral, 8 way .
All as per item 138 here-in-before but distribution board single pole and neutral, 4 way .
Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed.
All as per item 142 here-in-before but distribution board VTP & N 8 ways (TPN MCB DB) for TP-MCCB upto 160 Amps
All as per item 142 here-in-before but distribution board TP & N 12 ways (TPN MCCB DB) for TP-MCCB upto 160 Amps.
All as per item 142 here-in-before but distribution board TP & N 8 ways (TPN MCCB DB) for TP-MCCB upto 160 Amps .
S&F MCCB, 3 pole, 250 Amps current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
All as per item 146 here-in-before but MCCB, 3 pole, 160 Amps current rating and ultimate breaking capacity Icu = 16 KA.
All as per item 146 here-in-before but MCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity Icu = 16 KA t
All as per item 146 here-in-before but MCCB FP, 100 Amps having current rating 16 KA .
All as per item 146 here-in-before but MCB TPN, 63 Amps (`C’ series) having current rating 10 KA .
All as per item 146 here-in-before but MCB TP, 40 Amps (`C’ series) having current rating 10 KA .
S&F MCCB, 4 pole, 125 Amps,415 volt current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
Supply and fix MCB SPN, 40 Amps Amps, 230 volt (`C’ series) having current rating 10 KA. with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
All as per item 153 here-in-before but MCB SPN, 32 Amps (`C’ series) having current rating 10 KA.
All as per item 153here-in-before but MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA.
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed surfaces of walls floors etc all as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, terminal boxes closed recessed type. PVC Plastic board all as required as specified and directed for the following :- (a) One light/ Fan point controlled by one way switch.
(b ) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-157 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F in repairs switch piano flush type single pole one way 5 Amps 230 V.
S&F in repairs switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose,
All as per item No-162 above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) .
S&F in repairs socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type.
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
S&F in repairs lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge
Supply& Fixing in repairs LED Batten fittings 20 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engr-in-charge
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-charge.
M/s. Ravi and brothers
m/s vikash Engineers
M/s NILAY ENGINEERS
M/s R.D. Company
M/s Anjali Construction
M/s Bijender Singh
M/S YOGANSH CONSTRUCTION CO.
M/s Gulshan and Brothers
M/s Sagar Construction
SHRI RAM CONSTRUCTION
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .