| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹11.5 L+₹15,245.60 (1.35%)Accepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Accepted-Finance Accepted |
Tender Value
₹9.7 L
EMD Value
₹8,700
Closing Date
29 Nov 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
33/11KV S/s RDC, Gzb
Re-ccoducting of panther of 33 KV s/s sec-82 Noida and Bisnoli
2023_PVVNL_853845_1
65/ECWD/Gzb/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Ghaziabad
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
EE, EUCD (D), PVVNL, Gzb
₹8,700
5 Dec 2023
19 Oct 2023
29 Nov 2023
19 Oct 2023
29 Nov 2023
19 Oct 2023
(i) Re-Conductoring of Panther Conductor of 33/11KV Substation Sec-82, Noida Supply of following Material G.I. Channel 100x50x6 mm, 2400 mm long (9.56kg/mt) with G.I.Clamp of 65x8mm for dropper channel of 33KV line double pole/four pole
33KV Line Isolator 800 Amp.
Heat Shrinkable outdoor type end termination cable jointing kit suitable for 33KV XLPE 3x300 Sq. mm.cable
33KV Tension fitting for Panther
33KV suspension insulator fitting for Panther
V-Type Cross Arm 100x50x6 mm G.I channel for 33KV line with G.I.Clamp 75x10mm size
33KV Cross arm holding clamp with Nut & Bolt.
P.G.Clamp with Nut & bolt for Panther to Panther
Carriage of following material from PVVNL store A.C.S.R.Panther Conductor (From Transmission store as per availability)
Cable H.T.XLPE 33KV 3x300SQ.M.M
Steel Tubler Pole SP-55 11.00Mtr
33KV composite Polymeric Pin insulator.
33KV Polymer Disc insulator
Erection of Following Material & Miscellaneous Electrical Works. Installation of 33 KV Isolators: Assembling and installation of line/Bus Isolator on the isolator structure. Adjusting of operating mechanism in proper alignment so as to ensure smooth operation of the same. In case of Line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support structure, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) 11M Long STP, SP-55 Round Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. Single Pole (a) 11M Long STP, SP-55 Round Pole
Providing & Earthing of supports with M.S.Earth Rod of (20x2500)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting belowl the earth electrodes with the help of G.I.wire No.6SWG, G.I.Nut bolt & washer and earthing lugs.
Laying, spreading, lifting and final sagging of 3 phases ACSR Panther conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel.
Making Jumpers on Sectional Pole, by providing & fixing of P.G.Clamps of proper sizes, suitable for Panther Conductor/ 33KV, 3x300Sq.mm XLPE cable.
Providing & fixing of SMC Danger board at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I.Clamp & nut & bolt for 33KV
Providing & fixing of SMC Number Plate at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I.Clamp & nut & bolt.
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.
Making H.T.Connection of the proposed line from 33KV Line. The work consists of fixing & fabrication of Dropper Channels, & fixing of Disc Insulators, Pin Insulators, jumpering with P.G.Clamps, clamping and binding etc,as per site conditions.
Providing & Wrapping of barbed wire (2.0Kg per Pole) on 33KV ST Poles SP-55/SP-72 as anti-climbing device for a length of 0.9Mtr. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing and fixing of lower end & upper end clamps made of G.I.Flat 40x5mm complete with nuts&bolts.
Supply of Al. Paint & Red oxide Paint as per IS mark & PVVNL specification & Painting of following supports/structures of 33KVLine, with two coats of synthetic enamel aluminium paint after one coat of ready mix primer, including cost of all material, as well as rubbing/cleaning of surface as required for proper completion of work:- 11Mtr SP-55 Poles including all channels/x-arms/clamps etc. (i) Single Supports
Digging of Trench by excavation of earth of 1050x750mm size for 33KV line
Safe laying of 33KV, 3x300Sq.mm. XLPE Cable in Cable Trench to respective Double Pole.
Providing & Laying of Ist Class Bricks, along the length on both side of 33KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab (Smooth surface both side) of size 400x600x40mm on top of the Cable, Providing 150mm thickness River sand for cushion beneath and 150mm above the cable as per specification.
Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Laying of 33KV, 3x300Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing cable trench, Pucca trench, nala x-ing & G.I.Pipe and making connection with 33KV over head line at both ends. Including fixing of dropper channel on double pole.
Making of 33KV Outdoor type cable end termination by heat shrinkable XLPE Cable Jointing Kits and crimping with proper size aluminium lugs. Work includes providing Aluminum lugs, insulating tapes etc as per specifications.
Fixing of extra Dropper Channels on existing double Pole/Four Pole with G.I.Clamp with G.I.Nut bolt & washer.
Removal & Diamantling charges of damaged ACSR Panther Conductor from 33KV line & Making the bundles of removed conductors.
Safe carriage of old received back material from site to PVVNL store including loading & unloading at both end.
(ii) Re-Conductoring of Panther Conductor for 33/11KV Substation Chithera from 220KV Transmission Substation Supply of following Material P.G.Clamp with Nut & bolt for Panther to Panther
Carriage of following material from PVVNL store A.C.S.R.Panther Conductor (From Transmission store as per availability)
Erection of Following Material & Miscellaneous Electrical Works. Laying, spreading, lifting and final sagging of 3 phases ACSR Panther conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel work will also include Making Jumpers on Sectional Pole by fixing of P.G.Clamps of proper sizes, suitable for Panther Conductor
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.
Making H.T.Connection of the proposed line from 33KV Line. The work consists of fixing & fabrication of Dropper Channels, & fixing of Disc Insulators, Pin Insulators, jumpering with P.G.Clamps, clamping and binding etc,as per site conditions.
Removal & Diamantling charges of damaged ACSR Panther Conductor from 33KV line & Making the bundles of removed conductors.
Safe carriage of old received back material from site to PVVNL store including loading & unloading at both end.
(iii) Re-Conductoring of Panther Conductor for 33/11KV Substation Bishnoli from 220KV Transmission Substation. Supply of following Material 33KV Tension fitting for Panther
P.G.Clamp with Nut & bolt for Panther to Panther
Carriage of following material from PVVNL store A.C.S.R.Panther Conductor (From Transmission store as per availability)
33KV Polymer Disc insulator
Erection of Following Material & Miscellaneous Electrical Works. Laying, spreading, lifting and final sagging of 3 phases ACSR Panther conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel work will also include Making Jumpers on Sectional Pole by fixing of P.G.Clamps of proper sizes, suitable for Panther Conductor
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.
Making H.T.Connection of the proposed line from 33KV Line. The work consists of fixing & fabrication of Dropper Channels, & fixing of Disc Insulators, Pin Insulators, jumpering with P.G.Clamps, clamping and binding etc,as per site conditions.
Fixing of extra Dropper Channels on existing double Pole/Four Pole with G.I.Clamp with G.I.Nut bolt & washer.
Removal & Diamantling charges of damaged ACSR Panther Conductor from 33KV line & Making the bundles of removed conductors.
Removal & Diamantling charges of damaged Tension fitting.
Safe carriage of old received back material from site to PVVNL store including loading & unloading at both end.
P&H Engineering
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .